• Title/Summary/Keyword: Noise Monitoring Station

Search Result 25, Processing Time 0.027 seconds

Method of Measuring the Occupied Bandwidth of IS-95 Base Station at Remote Site

  • Lim, Jong-Soo;Kim, Sang-Tae
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.1
    • /
    • pp.7-11
    • /
    • 2003
  • CDMA(code division multiple access) has very large peak to average power ratio(PAR) and behave as noise-like wide band digital signals with 1.2288 Mbps transmission rate. For signals with high PAR like CDMA, it is reasonable to prescribe occupied bandwidth(OBW) as average occupied bandwidth. Bandwidth measurements of CDMA signals at remote site are affected by co-channel and adjacent channel interference from adjacent CDMA base station, distortion of signal by fading effect, spurious emission and environment noises. In this study, we have compared OBW measurements in an on-air environment with those measured in a base station using adjacent channel leakage ratio(ACLR) as a reference measurement factor. As results of analysis, the OBW at ACLR$\geq$35 ㏈ shows nearly same statistical characteristics regardless of the measurement locations and environments.

Simultaneous monitoring of motion ECG of two subjects using Bluetooth Piconet and baseline drift

  • Dave, Tejal;Pandya, Utpal
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.365-371
    • /
    • 2018
  • Uninterrupted monitoring of multiple subjects is required for mass causality events, in hospital environment or for sports by medical technicians or physicians. Movement of subjects under monitoring requires such system to be wireless, sometimes demands multiple transmitters and a receiver as a base station and monitored parameter must not be corrupted by any noise before further diagnosis. A Bluetooth Piconet network is visualized, where each subject carries a Bluetooth transmitter module that acquires vital sign continuously and relays to Bluetooth enabled device where, further signal processing is done. In this paper, a wireless network is realized to capture ECG of two subjects performing different activities like cycling, jogging, staircase climbing at 100 Hz frequency using prototyped Bluetooth module. The paper demonstrates removal of baseline drift using Fast Fourier Transform and Inverse Fast Fourier Transform and removal of high frequency noise using moving average and S-Golay algorithm. Experimental results highlight the efficacy of the proposed work to monitor any vital sign parameters of multiple subjects simultaneously. The importance of removing baseline drift before high frequency noise removal is shown using experimental results. It is possible to use Bluetooth Piconet frame work to capture ECG simultaneously for more than two subjects. For the applications where there will be larger body movement, baseline drift removal is a major concern and hence along with wireless transmission issues, baseline drift removal before high frequency noise removal is necessary for further feature extraction.

A Research for Removing ECG Noise and Transmitting 1-channel of 3-axis Accelerometer Signal in Wearable Sensor Node Based on WSN (무선센서네트워크 기반의 웨어러블 센서노드에서 3축 가속도 신호의 단채널 전송과 심전도 노이즈 제거에 대한 연구)

  • Lee, Seung-Chul;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.137-144
    • /
    • 2011
  • Wireless sensor network(WSN) has the potential to greatly effect many aspects of u-healthcare. By outfitting the potential with WSN, wearable sensor node can collects real-time data on physiological status and transmits through base station to server PC. However, there is a significant gap between WSN and healthcare. WSN has the limited resource about computing capability and data transmission according to bio-sensor sampling rates and channels to apply healthcare system. If a wearable node transmits ECG and accelerometer data of 4 channel sampled at 100 Hz, these data may occur high loss packets for transmitting human activity and ECG to server PC. Therefore current wearable sensor nodes have to solve above mentioned problems to be suited for u-healthcare system. Most WSN based activity and ECG monitoring system have been implemented some algorithms which are applied for signal vector magnitude(SVM) algorithm and ECG noise algorithm in server PC. In this paper, A wearable sensor node using integrated ECG and 3-axial accelerometer based on wireless sensor network is designed and developed. It can form multi-hop network with relay nodes to extend network range in WSN. Our wearable nodes can transmit 1-channel activity data processed activity classification data vector using SVM algorithm to 3-channel accelerometer data. ECG signals are contaminated with high frequency noise such as power line interference and muscle artifact. Our wearable sensor nodes can remove high frequency noise to clear original ECG signal for healthcare monitoring.

A Comparative Study on Forecasting Groundwater Level Fluctuations of National Groundwater Monitoring Networks using TFNM, ANN, and ANFIS (TFNM, ANN, ANFIS를 이용한 국가지하수관측망 지하수위 변동 예측 비교 연구)

  • Yoon, Pilsun;Yoon, Heesung;Kim, Yongcheol;Kim, Gyoo-Bum
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.123-133
    • /
    • 2014
  • It is important to predict the groundwater level fluctuation for effective management of groundwater monitoring system and groundwater resources. In the present study, three different time series models for the prediction of groundwater level in response to rainfall were built, those are transfer function noise model (TFNM), artificial neural network (ANN), and adaptive neuro fuzzy interference system (ANFIS). The models were applied to time series data of Boen, Cheolsan, and Hongcheon stations in National Groundwater Monitoring Network. The result shows that the model performance of ANN and ANFIS was higher than that of TFNM for the present case study. As lead time increased, prediction accuracy decreased with underestimation of peak values. The performance of the three models at Boen station was worst especially for TFNM, where the correlation between rainfall and groundwater data was lowest and the groundwater extraction is expected on account of agricultural activities. The sensitivity analysis for the input structure showed that ANFIS was most sensitive to input data combinations. It is expected that the time series model approach and results of the present study are meaningful and useful for the effective management of monitoring stations and groundwater resources.

The Development of the Data Error Inspection Algorithm for the Remote Sensing by Wireless Communication (원격계측을 위한 무선 통신 에러 검사 알고리즘 개발)

  • 김희식;김영일;설대연;남철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.993-997
    • /
    • 2004
  • A data error inspection algorithm for wireless digital data communication was developed. Original data converted By wireless digital data error inspection algorithm. Wireless digital data is high possibility to get distortion and lose by noise and barrier on wireless. If the data check damaged and lost at receiver, can't make it clear and can't judge whether this data is right or not. Therefore, by wireless transmission data need the data error inspection algorithm in order to decrease the data distortion and lose and to monitoring the transmission data as real time. This study consists of RF station for wireless transmission, Water Level Meter station for water level measurement and Error inspection algorithm for error check of transmission data. This study is also that investigation and search for error inspection algorithm in order to wireless digital data transmission in condition of the least data's damage and lose. Designed transmitter and receiver with one - chip micro process to protect to swell the volume of circuit. Had designed RF transmitter - receiver station simply by means of ATMEL one - chip micro processing the systems. Used 10mW of the best RF power and 448MHz-449MHz on frequency band which is open to public touse free within the limited power.

  • PDF

Spatial-temporal Assessment and Mapping of the Air Quality and Noise Pollution in a Sub-area Local Environment inside the Center of a Latin American Megacity: Universidad Nacional de Colombia - Bogotá Campus

  • Fredy Alejandro, Guevara Luna;Marco Andres, Guevara Luna;Nestor Yezid, Rojas Roa
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.232-243
    • /
    • 2018
  • The construction, development and maintenance of an economically, environmentally and socially sustainable campus involves the integration of measuring tools and technical information that invites and encourages the community to know the actual state to generate positive actions for reducing the negative impacts over the local environment. At the Universidad Nacional de Colombia - Campus $Bogot{\acute{a}}$, a public area with daily traffic of more than 25000 people, the Environmental Management Bureau has committed with the monitoring of the noise pollution and air quality, as support to the campaigns aiming to reduce the pollutant emissions associated to the student's activities and campus operation. The target of this study is based in the implementation of mobile air quality and sonometry monitoring equipment, the mapping of the actual air quality and noise pollution inside the university campus as a novel methodology for a sub-area inside a megacity. This results and mapping are proposed as planning tool for the institution administrative sections. A mobile Kunak$^{(R)}$ Air & OPC air monitoring station with the capability to measure particulate matter $PM_{10}$, $PM_{2.5}$, Ozone ($O_3$), Sulfur Oxide ($SO_2$), Carbon Monoxide (CO) and Nitrogen Oxide ($NO_2$) as well as Temperature, Relative Humidity and Latitude and Longitude coordinates for the data georeferenciation; and a sonometer Cirrus$^{(R)}$ 162B Class 2 were used to perform the measurements. The measurements took place in conditions of academic activity and without it, with the aim of identify the impacts generated by the campus operation. Using the free code geographical information software QGIS$^{(R)}$ 2.18, the maps of each variable measured were developed, and the impacts generated by the operation of the campus were identified qualitative and quantitively. For the measured variables, an increase of around 21% for the $L_{Aeq}$ noise level and around 80% to 90% for air pollution were detected during the operation period.

Application of Differential GPS for the Displacement Measurement of Self-anchored Suspension Bridge under the Static and Dynamic Loading Cases (DGPS 기법을 이용한 자정식 현수교의 정동적 변위응답 측정 및 분석)

  • Kim, Hyung-Tae;Seo, Ju-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.11
    • /
    • pp.1126-1132
    • /
    • 2009
  • Bridge structures are designed to support ordinary loadings such as vehicles, wind, temperature and current as well as unexpected loadings like earthquakes and storm. Especially, the displacement of Flexible bridges like an suspension bridge under ordinary loading conditions is necessary to be monitored. In case of long span bridges, there are some difficulties in monitoring the displacement of center of the main span using traditional laser displacement sensors. In this study, the static and dynamic displacement responses due to vehicle loadings were measured by DGPS(differential global positioning system) technique. The displacement response data were compared with data obtained from traditional laser displacement sensors so that the static and dynamic behavior of the bridge under vehicle loadings was examined and the applicability of the displacement response measurement using DGPS technique was verified. The static and dynamic loading test for an self-anchored suspension bridge, So-rok Bridge, was performed using vehicles. The displacement response from DGPS technique and that from laser displacement sensors of the bridge monitoring system were compared. The amplitude of white noise from DGPS based measurement was about 7 mm and that of laser displacement sensor based measurement was about 3 mm. On the other hand, dynamic behavior of the center of main span from DGPS based measurement showed better agreement with influence line of the bridge than that from laser displacement sensors. In addition, there were some irregular and discontinuous variation of data due to the instability of GPS receivers or frequent appearance of GPS satellites. Post-processing via the reference station close to an observation post provided by NGII(National Geographic Information Institute) will be a counter-plan for these defects.

Comparision Between Noise Levels of Hospital Wards and the Nurses Efforts for Noise Management in Selected General Hospital (종합병원 병동별 간호사실의 소음정도와 간호사실들의 소음인지도 및 소음관리노력 비교)

  • Jung, Hyun-Wook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.174-182
    • /
    • 2001
  • This study was performed to find out the differences between noise levels of hospital wards and the nurses efforts for noise management in some general hospitals. The hospital wards selected were the intensive care unit(ICU), the emergency room(ER), the nursery room(NR), the internal medicine(IM), the general surgery(GS) among the 5 general hospitals located in Seoul. The data were collected from August 3 to September 13, 1999 through questionnaire survey and noise measurement in each nursing station of hospital wards. Data analysis was done by SPSS 8.0 package among the 305 questionnaires and 24 hours monitored noise levels. Frequency, Chi-square and ANOVA test were used. The study results were as belows: 1. The noise level measured by 24 hours monitoring survey were exceeded on the standard limit in all the hospital wards. Data also showed that noise levels were significantly different in each ward among the three shifts working duties. 2. The subjects were all female nurses. They were mostly working in the ICU ward(28.9%). They were 26~30 years old (43.9%), junior college graduates(57.0%), working for 1~5 years(55.1%) as staff-nurse(85.6%). There were no significant differences between hospital wards and general characteristics of nurses. 3. The noise levels perceived by nurses were regarded as 'Highly noisy'(56.4%), especially during the 11:30 and 15:30 (30.2%) o'clock. Data also showed that noise education was not ever given to nurses(89.9%). Nurses also responded that they hardly put an effort to reduce noise level(54.8%). However, there were significant differences between wards and noisy working time, experience of noise education and level of effort for noise reduction. 4. Nurses also perceived the ventilator alarm and EKG-alarm as the most disturbing sounds in the ICU, human voice and telephone ringing in the ER, human voice and EKG-alarming in the NR, human voices and telephone ringing in IM and GS both wards respectively in order. There were significant differences between hospital wards and noise making factors. 5. Nurses were shown that they regarded highly 'Sound reduction of the human voice', 'Careful handling on medical instruments', and 'Immediate appliances on alarming materials' as the practical method for noise management. There were significant differences between hospital wards and behavioral practical efforts for noise management. According to that results, the statistical differences were shown in the 24 hour monitored noise levels in each ward. Also, nurses perceived the noise severity differently and they approached variously on the practical efforts for noise reduction in each ward. Thus, author thinks that concrete and systematic endeavor will be necessary for noise reduction and management in hospitals for better working and healing environment for both of patients and staffs.

  • PDF

Modeling of the T.C.M.S. using Power Line Carrier in Railway

  • Song, Y.S.;Lee, S.G.;Shin, S.K.;Han, S.H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2147-2150
    • /
    • 2003
  • Recently, many technologies of the P.L.C (Power Line Carrier) are introduced for an efficient communication. P.L.C communication sends information in the carrier signals by conduction over the power wire. An arc detector is proposed in this paper for the effective transmission. The Power Line Carrier has an advantage in low cost because it uses existent power line. It can be easily applied anywhere that a power line socket is available. But the P.L.C. is very noisy, because many electronic devices in generate electronic noise in modulated signals. This problem should be considered carefully in the design of the arc detector system using P.L.C in railway. The proposed system can be applied for monitoring the arc detector system and the arc locator system in railway. Hence the system will be able to exchange the arc information to be T.C.M.S. (Train Control Management System), bogies and even between a station and trains in railway and use to suspicion fire in train.

  • PDF

Design of a Prototype Fibre Optic Based Monitoring and Control System for Future KEPCO's 765kV Substation (765kV 변전소 감시제어용 시범시스템)

  • Jiang, Moon-Myung;Chung, Sang-Jin;Choi, Jong-Hyoub;Park, Jong-Myung
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.883-886
    • /
    • 1996
  • Instead of point-to-point hard wiring between substation yard equipments and SCADA RTU(Remote Terminal Unit), fibre optic cable will be used in the portion between Local Units and Central Unit in the future KEPCO 765kV substation. The connections between substation yard equipments and nearby Local Unit remain the same hard wiring. The new fibre optic system will provide security especially during ground faults and is immune to electrical noise. A prototype system will be manufactured and installed in the existing 154kV Yeosan Substation by the end of July this year and operated for one year. By incorporating the operation experiences acquired in the system, an improved system will be commercially applied to 765kV Shin-An-Seong Substation where 345kV GIS will be installed initially and act as the switching station in the year 1998. The system is composed of one Central Unit and several Local Units. The Central Unit is composed of two workstation level computers, one is in operation and the other backup, and a Communication Control Unit. The Local Unit uses the existing SCADA RTU technology and takes the form of a distributed one. Between the Communication Control Unit and Local Units, the fibre optic system with star-coupler is used.

  • PDF