• Title/Summary/Keyword: Noise Cut-off

Search Result 113, Processing Time 0.029 seconds

A Study on the Noise Property and its Reduction of the FCEV Blower (FCEV 블로워의 소음특성과 개선방향에 관한 연구)

  • Oh, Ki-Seok;Lee, Sang-Kwon;Seo, Sang-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1419-1424
    • /
    • 2007
  • Centrifugal turbo blower is requested highly efficiency and low noise in FCEV, but the noise generated by this machine causes of the most serious problems in the NVH performance. In general, centrifugal turbo blower is dominated by mechanical noise and aerodynamic noise. Mechanical noise is generated by rotation of the bearing, misalignment and unbalance. And aerodynamic noise is generated by the strong intersection between the flow discharged from the impeller and the cut-off in the casing. The first object of this study is to comprehend a noise property of the blower through the noise test. And, second object is to bring up the method that can reduce blower noise.

  • PDF

A Study on the Noise Property and Its Reduction of the FCEV Blower (FCEV 블로워의 소음특성과 개선방향에 관한 연구)

  • Oh, Ki-Seok;Lee, Sang-Kwon;Seo, Sang-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.5
    • /
    • pp.516-523
    • /
    • 2008
  • Centrifugal turbo blower is requested highly efficiency and low noise in FCEV, but the noise generated by this machine causes of the most serious problems in the NVH performance. In general, centrifugal turbo blower is dominated by mechanical noise and aerodynamic noise. Mechanical noise is generated by rotation of the bearing, misalignment and unbalance. And aerodynamic noise is generated by the strong intersection between the flow discharged from the impeller and the cut-off in the casing. The first object of this study is to comprehend a noise property of the blower through the noise test. And, second object is to bring up the method that can reduce blower noise.

Acoustic Wave Propagation Characteristics Corresponding to the Cut-off Frequency in Gas Pipeline (가스 배관의 차단 주파수에 따른 음파전달특성 연구)

  • Kim, Min-Soo;Lee, Sang-Kwon;Jang, Sang-Yup;Koh, Jae-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.693-700
    • /
    • 2008
  • High-Pressure gas Pipeline which is buried in underground has the Possibility that will be exposed to unexpected dangerous impact of construction equipment. To protect from this kind of danger, the real-time health monitoring system of the high-pressure gas pipeline is necessary. First of all, to make the real-time health monitoring system clearly, the acoustic wave propagation characteristics which are made from various construction equipment impacts must be identified. In link of technical development that prevents the damage of high-pressure gas pipeline, this paper gives FEM(finite element method) and BEM(boundary element method) solutions to identify the acoustic wave propagation characteristic of the various impact input signals which consist of Direc delta function and convolution signal of 45 Hz square signal and random signal.

A New Design of Power Folding Controller for Deterioration Detection (열화방지형 파워폴딩 제어기 설계에 관한 연구)

  • Kim, Ji-Hyeon;Lee, Dong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.51-58
    • /
    • 2008
  • This paper is a study of a prevention of power folding controller's thermal degradation. Power folding technology has been applied for many fields such as side rear vision mirror of vehicles, windshield wiper, antenna, power window. These controllers have been comprised with traditional DC moors, Switching electronic devices, and relays. But this methods have a limitation to overcome such problems of product reliability, endurance, noise margins. Therefore on this paper, to detect the movement of motor, sensing motor brush noise on a load sensing part has been used and controlling a precise RC timing control minimizes the thermal deterioration of motor. And using MOS FETs as a electronic switching device increases life-time and liability of control circuit. After testing such circuit and control method, repetition of operating time, cut-off time, wide operation voltage, power noise margin ware increased over eleven-fold.

Grain Size Determination of Copper Film by Electron Backscatter Diffraction (EBSD를 이용한 구리박막의 결정립 크기 결정)

  • Kim, Su-Hyeon;Kang, Joo-Hee;Han, Seung Zeon
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.9
    • /
    • pp.847-855
    • /
    • 2010
  • The grain size of a cross-section of $8{\mu}m$-thick copper film was determined by electron backscatter diffraction analysis. Grain size distribution histogram showed the presence of a large fraction of small-sized grains, and the mean grain size was significantly affected by handling of them. A cut-off grain size, below which all grains are ignored as noise and eliminated for the calculation of the mean value, should be three or four times as large as the step size. Due to the presence of small grains, the linear intercept method derived larger mean grain size, which depends less sensitively on the cut-off grain size than the equivalent circle diameter method.

A Study on the Design and Chracteristic Analysis for Noise Cut Transformer (NCT 설계 및 특성 분석에 관한 연구)

  • 이재복;허창수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.146-154
    • /
    • 1998
  • Broadband noise with frequency components in the range from several kHz up the tens of MHz is a major obstacle factor in normal operation of the AC line to supply the power to electrical and electronic control equipments. Because this kind of noise could damage the device or could be a source of malfunction, many devices such as filter and surge suppressor are used to cut off the noise. But those devices could not disconnected from the power line, so they result in poor common-mode of NCT as well as insulation characteristics as a isolation transformer in addition faraday shielding and proposed analysis model of NCT having tow functions of surge and noise reduction. The simulated and experimental results for the surge suppression characteristics are compared and evaluated for designed protype 1[kVA] NCT.

  • PDF

A Study on the Development of High Performance Interlayer Soundproofing Material Considering Long Term Deflection (장기처짐을 고려한 고성능 층간차음재 개발에 관한 연구)

  • Yang, Jin-Kook;Hong, Seong-Wook;Kang, Hyun-woo;Park, Young-Duk;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.107-108
    • /
    • 2019
  • The interlayer noise of the apartment house is a typical problem that reduces the quality of the residential environment. Therefore, many researchers have developed soundproofing materials that blocks noise between floors. However, most development technologies do not have the noise cut-off effect felt by residents, and may also have a defect in long-term deflection. In this respect, this study developed high-performance interlayer soundproofing material that can overcome existing problems. The developed technology has the noise reduction effect experienced by the residents and it has high durability without long-term deflection. Therefore, high-performance interlayer soundproofing material is expected to contribute to reducing disputes over noise between floors of apartment residents.

  • PDF

A Study on the Fan and Scroll for Ventilation (배기용 Fan Scroll에 대한 연구)

  • Song, S.B.;Park, S.I.;Lee, J.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.402-406
    • /
    • 2000
  • In the Over-The-Range, the outlet size is limited by the industrial standards. Therefor to enlarge the volume of cavity, the installation height of ventilation fan is become small, the system resistance is higher than before. For that reason, the important design variables such as the diameter of a fan, the scroll expansion angle, etc. which play the significant role on flow rate and noise, are confined. In this study, we made an experiment of the diameter of fans relation to scroll expansion angle and investigated flow rate of the length of fans in enlarged cavity volume of OTR, and then we designed the new scroll to improve the flow rate and noise level. As a result, flow rate increased to 110% compared to current scroll and the blade passing frequency of a fan is disappeared by inclined cut-off shapes.

  • PDF

A super low noise characteristics of AlGaAs/InGaAs/GaAs pseudomorphic HEMTs fabricated by the improved T-Gate (개선된 T-gate기술로 제작한 초저잡음 AlGaAs/InGaAs/GaAs pseudomorphic HEMT 소자의 특성)

  • 이진희;윤형섭;최상수;박철순;박형무
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.3
    • /
    • pp.118-123
    • /
    • 1995
  • We have successfully fabricated a super low noise pseudomorphic HEMT(PHEMT) device with AlGaAs/InGaAs/GaAs sturcture by using improved T-Gate which have increased a large gaet cross-sectional area about two times in comparision with those of conventional T-gate processes. The PHEMSTs with 0.15$\mu$m-long and 140$\mu$m-wide gates have eshibited a super low noise characteristics, the noise figure of 0.45dB with associated gain of 10.87dB at 12GHz. The cut-off rewuqncy of the device is 94gHz with a transconductance of 418mS/mm.

  • PDF

An Experimental Investigation on Noise Reduction Performance of the Absorption and the Resonance Type Duct Silencers (흡음형과 공명형 덕트 소음기의 소음저감 성능에 관한 실험적 고찰)

  • Lee, Young-Sup;Chung, Kwang-Seop;Lee, Dong-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.897-901
    • /
    • 2010
  • A silencer has been widely used for the purpose of suppressing the noises propagated from duct of air conditioning system. The absorption type silencer is usually applied to reduce the noise with high frequency bandwidth. On the order hand, the resonance type silencer is applied to reduce the noise with low-middle frequency bandwidth. The insertion loss of silencer is measured in the reverberation room. The cut-off frequency of reverberation room is 100 Hz. The insertion loss of absorption type silencer is more larger than that for resonance type silencer regardless of changing the flow velocity.