• 제목/요약/키워드: Noise Amplification

검색결과 156건 처리시간 0.021초

Convergence Analysis of Noise Robust Modified AP(affine projection) Algorithm

  • Kim, Hyun-Tae;Park, Jang-Sik
    • Journal of information and communication convergence engineering
    • /
    • 제8권1호
    • /
    • pp.23-28
    • /
    • 2010
  • According to increasing projection order, the AP algorithm bas noise amplification problem in large background noise. This phenomenon degrades the performances of the AP algorithm. In this paper, we analyze convergence characteristic of the AP algorithm and then suggest a noise robust modified AP algorithm for reducing this problem. The proposed algorithm normalizes the update equation to reduce noise amplification of AP algorithm, by adding the multiplication of error power and projection order to auto-covariance matrix of input signal. By computer simulation, we show the improved performance than conventional AP algorithm.

통신정보용 광대역 저잡음 증폭단 설계 및 구현 (Design and Fabrication of wideband low-noise amplification stage for COMINT)

  • 고민호
    • 한국전자통신학회논문지
    • /
    • 제7권2호
    • /
    • pp.221-226
    • /
    • 2012
  • 본 논문에서는 광대역 (400 MHz~2000 MHz) 2단 증폭단을 설계, 제작 및 측정하였다. 제안한 증폭단은 새로운 구조의 이득제어 방식을 적용하여 고이득, 저잡음지수 및 높은 선형성 특성을 구현하였다. 증폭단은 공통 에미터 구조의 초단 증폭기 및 캐스코드 구조의 가변이득 증폭기. 입력신호의 크기를 감지하는 전력감지회로로 구성하였다. 제안한 증폭단은 설계 대역에서 전체이득 29 dB~37 dB, 잡음지수 1.5 dB을 나타내었고, 강전계 입력 조건에서 전력감지회로에서 발생되는 제어전압 2.0V인 조건에서 3차 상호변조 왜곡 신호의 크기는 측정 장비의 잡음레벨 보다 낮은 특성을 나타내어 높은 선형성 특성을 나타내었다.

A Phase Unwrapping Algorithm in Three-Wavelength Digital Holographic Microscopy

  • Shin, Sanghoon;Yu, Younghun
    • 새물리
    • /
    • 제68권12호
    • /
    • pp.1378-1383
    • /
    • 2018
  • Multi-wavelength holography has a better axial range than single-wavelength holography, thus allowing unambiguous phase imaging. Noise amplification is the limiting factor in multi-wavelength holography as noise is amplified by a factor equivalent to the magnification of the wavelengths. Here, we propose a new algorithm to remove noise amplification in multi-wavelength holography. The proposed method does not use phase unwrapping and removes $2{\pi}$ ambiguities. Experiments and numerical simulations indicated that the proposed method is fast, has low noise, and is useful for measuring samples with arbitrary step heights.

Low-Noise MEMS Microphone Readout Integrated Circuit Using Positive Feedback Signal Amplification

  • Kim, Yi-Gyeong;Cho, Min-Hyung;Lee, Jaewoo;Jeon, Young-Deuk;Roh, Tae Moon;Lyuh, Chun-Gi;Yang, Woo Seok;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • 제38권2호
    • /
    • pp.235-243
    • /
    • 2016
  • A low-noise readout integrated circuit (ROIC) for a microelectromechanical systems (MEMS) microphone is presented in this paper. A positive feedback signal amplification technique is applied at the front-end of the ROIC to minimize the effect of the output buffer noise. A feedback scheme in the source follower prevents degradation of the noise performance caused by both the noise of the input reference current and the noise of the power supply. A voltage booster adopts noise filters to cut out the noise of the sensor bias voltage. The prototype ROIC achieves an input referred noise (A-weighted) of -114.2 dBV over an audio bandwidth of 20 Hz to 20 kHz with a $136{\mu}A$ current consumption. The chip is occupied with an active area of $0.35mm^2$ and a chip area of $0.54mm^2$.

완충재의 동특성에 따른 중량충격음 증폭에 관한 해석적 연구 (The Effect of Dynamic Property of Absorbing Sheet on the Amplification of Heavy Weight Floor Impact Noise)

  • 황재승;문대호;박홍근;홍성걸;홍건호
    • 한국소음진동공학회논문집
    • /
    • 제20권7호
    • /
    • pp.651-657
    • /
    • 2010
  • Previous experimental results performed by many researchers for a couple of decades in South Korea have shown that an absorbing sheet inserted in a conventional floating slab system for thermal insulation or vibration absorption may amplify the vibration of the slab system at specific frequency ranges depending on the material properties of the sheet. The amplified vibration, consequently, results in the heavy weight floor impact noise exceeding the sound level limit for an apartment house, 50 dB. In this study, the amplification mechanism is examined through numerical analysis and a new slab system is proposed to reduce the amplification and control the noise. The new slab system consists of studs connecting the base slab and upper concrete finishing yielding the dramatically increased stiffness of the slab. The numerical simulation is performed to investigate the effect of the slab system with studs on the vibration and noise control. The results show that the performance of the slab is sensitive to the number and location of studs, and the heavy weight floor impact noise can be reduced up to 6~7 dB compared to the conventional slab system at the optimal stud location.

완충재의 동특성에 따른 중량충격음 증폭에 관한 해석적 연구 (The effect of dynamic property of absorbing sheet on the amplification of heavy weight floor impact noise)

  • 황재승;문대호;박홍근;홍성걸;홍건호;임주혁;김용남
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.527-528
    • /
    • 2010
  • Previous experimental results performed by many researchers for a couple of decades in South Korea have shown that an absorbing sheet inserted in a conventional floating slab system for thermal insulation or vibration absorption may amplify the vibration of the slab system at specific frequency ranges depending on the material properties of the sheet. The amplified vibration, consequently, results in the heavy weight floor impact noise exceeding the sound level limit for an apartment house, 50dB. In this study, the amplification mechanism is examined through numerical analysis and a new slab system is proposed to reduce the amplification and control the noise. The new slab system consists of studs connecting the base slab and upper concrete finishing yielding the dramatically increased stiffness of the slab. The numerical simulation is performed to investigate the effect of the slab system with studs on the vibration and noise control. The results show that the performance of the slab is sensitive to the number and location of studs, and the heavy weight floor impact noise can be reduced up to 6-7dB compared to the conventional slab system at the optimal stud location.

  • PDF

4개 변전소시설 부지 인근관측소의 지반증폭 특성 및 파형에너지 수준 비교 연구 (A Comparison Study of the Site Amplification Characteristics and Seismic Wave Energy Levels at the Sites near Four Electric Substations)

  • 유성화;김준경;위성훈
    • 한국지구과학회지
    • /
    • 제37권1호
    • /
    • pp.40-51
    • /
    • 2016
  • 실제 국내에서 관측된 가속도를 이용한 스펙트럼 값이 내진설계기준보다 상대적으로 크게 나타나는 경향을 보이며, 특히 고진동수 구간에서 국내 내진설계 기준이 국내 고유의 지반증폭 특성을 제대로 반영하지 못하고 있어 문제점이 많다고 지적되어 왔다. 지반증폭 특성을 분석할 때 여러 가지 방법이 제시되어 왔으며 본 연구는 현장에서 자주 적용되고 있는 지반진동의 수평/수직 스펙트럼 비율을 이용하는 방법을 적용하였다. 이 방법은 S파 및 레일리파를 이용하는 것으로부터 출발하였으나, 최근 Coda파 및 배경잡음 등에 확대 적용되어 지반의 동적인 증폭특성 연구에 많이 이용되고 있다. 제한된 연구 기간 동안 4개 변전소시설 관측소 각각 2개 지점(노두 및 시추공)에서 운영되었고 본 연구는 4개 관측소의 노두에서 동시에 관측된 3개 중규모 지진의 가속도 지반진동(S파, Coda파 및 배경잡음)을 이용하여 지반증폭을 분석하였다. 분석결과는 4개 관측소 각각에 대해 기존 연구결과인 시추공 지반증폭 특성과 상호 비교하였다. 또한 각각 관측소 및 지점에서 지반의 우월진동수를 이용하여 각각 지반에 대한 등급분류도 시도하였다. 각각의 지진관측소마다 저진동수 및 고진동수 특성, 관측소 고유의 우월진동수가 서로 상이하여 관측소 고유의 증폭특성을 보여주었다. 대다수 관측소는 S파, Coda파 및 배경잡음 에너지를 분석한 결과와 많은 부분이 유사함을 보여 주었다. 물론 본 연구로부터 도출된 결과를 다른 방법에 적용하여 얻어진 결과와 비교한다면 지반의 동적 특성 및 지반분류 연구에 많은 정보를 제시할 수 있다고 판단된다.

배경잡음, S파 및 Coda파 에너지를 이용한 예당저수지 인근부지의 지반증폭 특성에 관한 비교 연구 (A Comparison Study of the Amplification Characteristics of the Seismic Station near Yedang Reservoir using Background Noise, S-wave and Coda wave Energy)

  • 위성훈;김준경;유성화;경재복
    • 한국지구과학회지
    • /
    • 제36권7호
    • /
    • pp.632-642
    • /
    • 2015
  • 지반진동은 지진원, 지각감쇠 및 지반의 증폭특성 등 3가지 주요 인자로 구성되어 있다. 이 중 지반 증폭특성은 지진원 및 지각감쇠를 신뢰성 있게 평가하기 위해 반드시 고려하여야 한다. 본 연구의 목적은 수평/수직(H/V) 스펙트럼비를 이용하여 각 관측소의 지반증폭 특성을 평가하는 것이다. 주파수 영역에서 H/V 스펙트럼 비를 구하는 방법은 Nakamura(1989)에 의해 처음으로 제시되었으며, 초기에는 상시미동의 표면파 특성을 이해하기 위해 사용되어 왔다. 최근에 와서 강진동의 전단파 에너지 등으로 확장되면서 지반 증폭특성 연구에 많이 이용되고 있다. 본 연구는 예당저수지 인근에 4개의 관측소에서 관측된 6개의 가속도 지반진동을 이용하여 H/V 스펙트럼 비를 분석하였고 각 지반진동의 S파, Coda파 및 배경잡음 각각으로부터 분석된 지반증폭 특성을 상호 비교하였다. 분석결과, 4개 관측소는 각각의 우월 주파수 대역(YDS: ~11 Hz, YDU: ~4 Hz, YDD: ~7 Hz)에서 관측소 고유의 증폭특성을 보여준다. 본 연구의 도출 결과와 다른 방법을 통해 구한 결과의 비교 평가는 국내 지반의 동적특성 및 지반분류 연구에 유익한 정보가 될 것으로 판단된다.

Ka-band 위성방송수신용 저잡음 블록 변환기 구현 (Implementation of Ka-band Low Noise Block Converter For Satellite TVRO)

  • 임진원;김태진;박주남;이영철
    • 한국전자통신학회논문지
    • /
    • 제3권2호
    • /
    • pp.93-100
    • /
    • 2008
  • 본 논문에서는 상업용 MMIC를 이용하여 Ka-대역 위성 텔레비전 방송 수신 전용(TVRO) 저 잡음 하향변환 증폭단을 설계하였다. 저 잡음 블록은 입력단에서 저 잡음 정합시킨 증폭기를 포함한 3단 증폭기, 이미지 제거용 대역통과필터, 주파수 혼합기, 주파수 체배기 및 IF단으로 구성하였다. 저 잡음블럭을 구성하는 모듈에 대한 감쇄와 전력이득에 대한 분석을 통하여 Ka-band LNB의 특성을 만족시키는 소자를 선정하였다. 설계된 저 잡음 블록에 대한 실험 결과 변환이득은 $58{\pm}1dB$, 잡음지수 1.5dB 이하, 위상잡음은 -94.6dBc@10KHz를 나타내었다.

  • PDF

기준관측소 방법을 이용한 댐체 기반암의 동적 지반증폭특성 (The Dynamic Basement Amplification Characteristics of a Dam Site using a Reference Site Method)

  • 위성훈;김준경;유성화
    • 한국지구과학회지
    • /
    • 제38권2호
    • /
    • pp.161-171
    • /
    • 2017
  • 관측된 지반진동은 지진원, 지각감쇠 및 지반의 증폭특성 등 3가지 주요 인자로 구성되어 있고 특히 지반증폭 특성은 지진원 및 감쇠특성을 평가할 때 필요하다. 또한 지진재해도를 분석하기 위해 지반의 증폭 특성에 정보가 내진공학 뿐만 아니라 암반공학적 특성 분석에서 필수적이다. 지반의 증폭특성 분석을 위해 분석대상 관측소와 기준 관측소 지반진동의 수평/수직 비를 이용하는 방법을 적용하였다. 기존의 기준관측소의 수직성분 방법에 더하여 새로이 기준관측소의 수평성분 방법을 새로이 시도하였다. 본 연구는 예당저수지 인근에 설치한 4개의 관측소에서 관측된 6개의 가속도 지반진동을 이용하여 각 지반진동의 S파, Coda파 및 배경잡음 각각을 분석한 지반증폭 특성을 상호 비교하였다. 4개 관측소 공통적으로 S파와 Coda파를 이용한 결과는 상호 유사한 지반증폭 특성을 보였다. 다만 배경잡음은 다른 2개 지진 에너지와 비교할 때 전혀 다른 지반증폭 특성을 보였고 이는 배경잡음의 발생 원인이 관측소 마다 서로 다르기 때문으로 입증되었다. 4개 각각의 지진 관측소마다 저주파수 및 고주파수 증폭특성과 관측소 고유의 우월주파수가 서로 상이하여 관측소 고유의 증폭특성을 보여주었다. 또한 본 연구의 결과와 다른 방법의 결과와 비교하면 지반의 동적특성 및 지반분류 연구에 많은 정보를 제시할 수 있다.