• Title/Summary/Keyword: NmF2

Search Result 991, Processing Time 0.028 seconds

Effects of Deposition Variables on Plasma-Assisted CVD of TiN Films (TiN박막의 증착특성에 미치는 플라즈마 화학증착변수들의 영향)

  • 이정래;김광호;신동원;박찬경
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.10
    • /
    • pp.1188-1196
    • /
    • 1994
  • TiN films were deposited onto high speed steel(SKH9) and silicon wafer by plasma-assisted chemical vapor deposition(PACVD) using a TiCl4/N2/H2/Ar gas mixture. The effects of deposition temperature, R.F. power, and H2 concentration on the deposition of TiN were studied. The residual chlorine content and the microhardness of TiN films were also investigated. It was found that TiN films grew with a columnar structure of a strong (200) preferred orientation regardless of the substrate type and the deposition variables. The TiN films consisted of columnar-grains of about 50 to 100 nm in diameter. The columnar grains themselves contained much finer fibrous grains. As deposition temperature increased, the residual chlorine content decreased sharply. R. F. powder enhanced the deposition rate largely. Increasing of H2 concentration had little effect on the residual chlorine.

  • PDF

TOP-EMISSION CHARACTERISTICS OF ORGANIC LIGHT-EMITTING DIODES (유기발광소자의 전면 발광 특성)

  • Shin, Eun-Chul;Park, Il-Heung;Lee, Ho-Shik;Cho, Sung-Ho;Min, Hang-Gi;Kim, Tae-Wan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.58-59
    • /
    • 2007
  • We have fabricated top-emission. organic ligth-emitting diodes in a structure of Glass/Al/2-TNATA/TPD/$Alq_3$/LiF/Al/Ag. By varying a film thickness of 2-TNATA and TPD, current efficiency, luminance efficiency, and viewing angle dependence of the device were measured. The top device using $Alq_3$ showed electroluminescent peak wavelengths of 522nm and 505nm at $0^{\circ}$ and $60^{\circ}$ viewing angles, respectively. It is thought that a microcavity effect affects on peak wavelength position for different viewing angles.

  • PDF

Electrochemical and Spectrofluorometric Behaviors of Eu(III) Complexes in Aqueous Solution

  • Chae Won-Seok;Kim Kang-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.12
    • /
    • pp.1050-1054
    • /
    • 1994
  • Eu(Ⅲ) exhibits one electron-transfer reduction at E$_{1/2}$ =-0.617 V vs. Ag/AgCl and the hypersensitive peak at 618 nm corresponding to $^5D_0$ ${\leftrightarro}$ $^7F_2$ transition in 0.10 M LiClO$_4$ aqueous solutions. Upon the addition of carboxylate or sulfonate anions to the Eu(Ⅲ) aqueous solutions, the reduction potential shifts negatively and the reduction current decreases because of the complex formation between Eu(Ⅲ) ions and the anions. However, for the case of carboxylate anion (acetate or propionate) the shift of reduction peak potential and the emission intensity at 618 nm are greater. The results are interpreted in terms of the differences in the formation constants and the hypersensitivity.

Magnetite Nanoparticles Containing Nanoporous Carbon for the Adsorption of Ibuprofen (마그네타이트 나노입자를 포함한 탄소나노세공체 합성과 아이부프로펜 흡착거동)

  • Park, Sung Soo;Ha, Chang-Sik
    • Journal of Adhesion and Interface
    • /
    • v.14 no.2
    • /
    • pp.82-87
    • /
    • 2013
  • Preliminary studies on the synthesis of magnetic nanoparticles including nanoporous carbon materials have been done via a direct carbonization process from resol, ferric nitrate and triblock copolymer F127. The results show that the nanoporous magnetite/carbon ($Fe_3O_4$/carbon) with a low $Fe_3O_4$ content (1 wt%) possesses an ordered 2-D hexagonal (p6mm) structure, uniform nanopores (3.6 nm), high surface areas (up to 635 $m^2/g$) and pore volumes (up to 0.48 $cm^3/g$). Magnetite nanoparticles with a small particle size (10.2 nm) were confined in the matrix of amorphous carbon frameworks with superparamagnetic property (7.7 emu/g). The nanoporous magnetite/carbon showed maximum adsorption amount (995 mg/g) of ibuprofen after 24 h at room temperature. The nanoporous magnetite/carbon was separated from solution easily by using a magnet. The nanoporous magnetite/carbon material is a good adsorbent for hydrophobic organic drug molecules, i.e. ibuprofen.

Development and Validation of 18F-FDG PET/CT-Based Multivariable Clinical Prediction Models for the Identification of Malignancy-Associated Hemophagocytic Lymphohistiocytosis

  • Xu Yang;Xia Lu;Jun Liu;Ying Kan;Wei Wang;Shuxin Zhang;Lei Liu;Jixia Li;Jigang Yang
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.466-478
    • /
    • 2022
  • Objective: 18F-fluorodeoxyglucose (FDG) PET/CT is often used for detecting malignancy in patients with newly diagnosed hemophagocytic lymphohistiocytosis (HLH), with acceptable sensitivity but relatively low specificity. The aim of this study was to improve the diagnostic ability of 18F-FDG PET/CT in identifying malignancy in patients with HLH by combining 18F-FDG PET/CT and clinical parameters. Materials and Methods: Ninety-seven patients (age ≥ 14 years) with secondary HLH were retrospectively reviewed and divided into the derivation (n = 71) and validation (n = 26) cohorts according to admission time. In the derivation cohort, 22 patients had malignancy-associated HLH (M-HLH) and 49 patients had non-malignancy-associated HLH (NM-HLH). Data on pretreatment 18F-FDG PET/CT and laboratory results were collected. The variables were analyzed using the Mann-Whitney U test or Pearson's chi-square test, and a nomogram for predicting M-HLH was constructed using multivariable binary logistic regression. The predictors were also ranked using decision-tree analysis. The nomogram and decision tree were validated in the validation cohort (10 patients with M-HLH and 16 patients with NM-HLH). Results: The ratio of the maximal standardized uptake value (SUVmax) of the lymph nodes to that of the mediastinum, the ratio of the SUVmax of bone lesions or bone marrow to that of the mediastinum, and age were selected for constructing the model. The nomogram showed good performance in predicting M-HLH in the validation cohort, with an area under the receiver operating characteristic curve of 0.875 (95% confidence interval, 0.686-0.971). At an appropriate cutoff value, the sensitivity and specificity for identifying M-HLH were 90% (9/10) and 68.8% (11/16), respectively. The decision tree integrating the same variables showed 70% (7/10) sensitivity and 93.8% (15/16) specificity for identifying M-HLH. In comparison, visual analysis of 18F-FDG PET/CT images demonstrated 100% (10/10) sensitivity and 12.5% (2/16) specificity. Conclusion: 18F-FDG PET/CT may be a practical technique for identifying M-HLH. The model constructed using 18F-FDG PET/CT features and age was able to detect malignancy with better accuracy than visual analysis of 18F-FDG PET/CT images.

Preparation of Nb2O5-Graphene Nanocomposites and Their Application in Photocatalytic Degradation of Organic Dyes (Nb2O5-Graphene나노복합체의 제조 및 유기염료 광촉매 분해반응의 응용성에 관한 연구)

  • Park, Hae Soo;Ko, Weon Bae
    • Elastomers and Composites
    • /
    • v.49 no.4
    • /
    • pp.330-335
    • /
    • 2014
  • Niobium pentoxide ($Nb_2O_5$) nanoparticles were synthesized using niobium (V) chloride and pluronic F108NF as the precursor and templating agent, respectively. The $Nb_2O_5$-graphene nanocomposites were placed in an electric furnace at $700^{\circ}C$ and calcined under Ar atmosphere for 2 h. The morphology, crystallinity, and photocatalytic degradation activity of the samples were characterized by X-ray diffraction, transmission electron microscopy, scanning electron microscopy, and UV-vis spectroscopy. The $Nb_2O_5$-graphene nanocomposites acted as a photocatalyst in the photocatalytic degradation of organic dyes under 254 nm UV light; the organic dyes used were methylene blue (MB), methyl orange (MO), rhodamine B (RhB), and brilliant green (BG). The photocatalytic degradation kinetics for the aforesaid dyes were determined in the presence of the $Nb_2O_5$-graphene nanocomposites.

Photoluminescence Characteristic of Gallate-Based Red Emitting Phosphors with High Color Purity (색순도가 우수한 갈륨 산화물계 적색 형광체의 광발광 특성)

  • Kim, Kyoung-Un;Choi, Sung-Ho;Jung, Ha-Kyun;Nahm, Sahn
    • Korean Journal of Materials Research
    • /
    • v.18 no.3
    • /
    • pp.159-162
    • /
    • 2008
  • $Eu^{3+}$-activated $R_3GaO_6$ (R = Y, Gd) phosphors were prepared in a conventional solid-state reaction and their optical properties were investigated. These compounds exhibit strong red emission under light excitation at 254 nm. The emission spectra are dominated by peaks appearing around 610-630 nm that are induced by the electric dipole transition of $^5D_0\;{\rightarrow}\;^7F_2$ of $Eu^{3+}$. In addition, the appropriate CIE (Commission Internationale de l'clairage) chromaticity coordinates, (x = 0.656, y = 0.336) for $Y_3GaO_6$ and (x = 0.655, y = 0.334) for $Gd_3GaO_6$, become closer to the NTSC (National Television System Committee) standard values. With the optimized activator concentrations, the maximum emission brightness is approximately 80% of $Y_2O_3$:$Eu^{3+}$ typical red-emitting phosphor with improved color purity under an excitation condition of 254 nm.

Fabrication of Wafer-Scale Anodized Aluminum oxide(AAO)-Based capacitive biosensor

  • Kim, Bongjun;Oh, Jeseung;Yoo, Kyunghwa
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.372.2-372.2
    • /
    • 2016
  • Various nanobiosensors have been developed and extensively investigated. For their practical applications, however, the reproducibility and uniformity should be good enough and the mass-production should be possible. To fabricate anodized aluminium oxide (AAO)-based nanobiosesnor on wafer scale, we have designed and constructed a wafer-scale anodizing system. $1{\mu}m$-thick-aluminum is deposited on 4 inch SiO2/Si substrate and then anodized, resulting in uniform nanopores with an average pore diameter of about 65 nm. Furthermore, most AAO sensors constructed on this wafer provide capacitance values of 30 nF ~ 60 nF in PBS, demonstrating their uniformity.

  • PDF

Light Scattering from Microscopic Structure and Its Role on Enhanced Haze Factor

  • Kang, Junyoung;Park, Hyeongsik;Yi, Junsin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.340-340
    • /
    • 2016
  • We have prepared alumina (Al2O3) doped zinc oxide (AZO) films by DC magnetron sputtering (MS) technique and obtained higher self surface texturing at a high target angle (f). We have characterized the films and applied it as a front electrode of a single junction amorphous silicon solar cell. At a lower f the deposited films show higher values of optical gap (Eg), charge carriers mobility & concentration, crystallite grain size and wider wavelength range of transmission. At higher target angle the sheet resistance, surface roughness, haze factor etc for the films increase. For f=72.5o the haze factor for diffused transmission becomes 6.46% at 540 nm wavelength. At f=72.5o the material shows a reduction in crystallinity and evolution of a hemispherical-type sub-micron surface textures. A Monte Carlo method (MCM) of simulation of the AZO film deposition shows that such an enhanced self-surface texturing of the films at higher f is possible.

  • PDF

Parametric study of inductively coupled plasma etching of GaN epitaxy layer (GaN epitaxy 층의 식각특성에 미치는 공정변수의 영향)

  • Choi, Byoung Su;Park, Hae Li;Cho, Hyun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.4
    • /
    • pp.145-149
    • /
    • 2016
  • The effect of process parameters such as plasma composition, ICP (Inductively Coupled Plasma) source power and rf chuck power on the etch characteristics of GaN epitaxy layer was studied. $Cl_2/Ar$ ICP discharges showed higher etch rates than $SF_6/Ar$ discharges because of the higher volatility of $GaCl_x$ etch products than $GaF_x$ compounds. As the Ar ratio increases in the $Cl_2/Ar$ ICP discharges, the etch anisotropy was enhanced due to the improved physical component of the etching. For both plasma chemistries, the GaN etch rate increased continuously as both the ICP source power and rf chuck power increased, and a maximum etch rate of 251.9 nm/min was obtained at $13Cl_2/2Ar$, 750W ICP power, 400W rf chuck power and 10 mTorr condition.