• Title/Summary/Keyword: Nitrogen oxides (NOx)

Search Result 184, Processing Time 0.025 seconds

Numerical Investigation of Low-pollution Combustion with applying Flue Gas Recirculation in Counterflow Flames: Part II. Analysis of NOx formation mechanism (대향류 화염에서 FGR이 적용된 저공해 연소의 수치적 해석: Part II. NOx 생성기구 분석)

  • Cho, Seo-Hee;Kim, Gyeong-Mo;Lee, Kee-Man
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.39-47
    • /
    • 2020
  • Flue gas recirculation(FGR) is an effective combustion technique for reducing nitrogen oxides(NOx) and is applied in various fields of low-pollution combustion. Continuing the previous study, a numerical analysis was conducted to identify changes of flame characteristics and NOx formation mechanism with applying FGR technique in CH4/air premixed counterflow flames. NOx emitted was divided into four main reaction paths(thermal NO, prompt NO, N2H and N2O), showing relatively the production rate of NO with the recirculation ratio. As a result, thermal NO contributed greatly to the overall NO whereas the effect of N2H was minimal. In addition, emission index of NO was compared as the recirculation ratio increased by modifying the UC San Diego mechanism to examine the contribution of thermal NO.

NOx Formation Characteristics with Oxygen Enrichment in Nonpremixed Counterflow Flames (비예혼합 대향류화염에서 산소부화에 따른 NOx 생성특성)

  • Lee, Chang-Eon;Hwang, Cheol-Hong;Yoo, Byung-Hun;Han, Ji-Woong
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.17-22
    • /
    • 2007
  • The NOx emission characteristics with oxygen enrichment in non-premixed counterflow flames were investigated numerically. To consider systematically the situation of inevitable $N_2$ contamination by air infiltration in the process of pure-oxygen combustion, the volume ratio of $O_2$ in an oxidizer was changed from 21% to 100%. As a result the NO emission index $(EI_{NO})$ has the highest value under condition of 75% oxygen enrichment. This result can be explained by the change of $N_2$ destruction rate with oxygen enrichment rather than flame temperature, flame thickness and residence time. In particular, it was found that the reaction of N+NO=$N_2+O$ has the largest contribution on NOx production in oxygen-enrichment flames.

  • PDF

The Effect of EGR on Exhaust Emissions in a Direct Injection Diesel Engine (직분식 소형 과급 디젤엔진에서 EGR이 배기배출물에 미치는 영향)

  • Jang, Se-Ho;Koh, Dae-Kwon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.188-194
    • /
    • 2005
  • The direct injection diesel engine is one of the most efficient thermal engines. For this reason DI diesel engines are widely used for heavy-duty applications. But the world is faced with very serious problems related to the air pollution due to the exhaust emissions of diesel engine. So, that is air pollution related to exhaust gas resulted from explosive combustion should be improved. Exhaust Gas Recirculation(EGR) is a proven method to reduce NOx emissions. In this study, the experiments were performed at various engine loads while the EGR rates were set from $0\%$ to $30\%.$ The emissions trade-off and combustion of diesel engine are investigated. The brake specific fuel consumption rate is very slightly fluctuated with EGR in the range of experimental conditions. The ignition delay increased with increasing EGR rate. The maximum value of premixed combustion for the rate of heat release is increased with increasing EGR rate. NOx emissions are decreased with increasing EGR rate at high load and high speed. It was found that the exhaust emissions with the EGR system resulted in a very large reduction in oxides of nitrogen at the expense of higher smoke emissions.

Evaluation of Catalyst Assisted EGR Cooler System for EGR Cooler Fouling Reduction (EGR Cooler Fouling 저감을 위한 촉매 장착 EGR Cooler System 평가)

  • Hong, Kwang-Seok;Park, Jung-Soo;Lee, Kyo-Seung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.5
    • /
    • pp.76-81
    • /
    • 2011
  • Exhaust gas recirculation is the well-known and widely used NOx reduction technology for diesel engines. More effective EGR cooler has been developed and applied to diesel engines to meet the reinforced emission regulation. However, the contaminated EGR cooler by diesel exhaust gas reduces the performance of the engine and NOx reduction rate. The buildup of deposits in EGR coolers cause significant degradation in heat transfer performance, often on the order of 20~30%. Deposits also increase pressure drop across coolers and thus may degrade engine efficiency under some operation conditions. In this study, as a solution for this problem, DOC assisted EGR cooler is designed and then investigated to reduce fouling and its impact on cooler performance. A single channel EGR cooler fouling test apparatus and soot particle generator were developed to represent the real EGR cooler and exhaust gas of diesel engine. EGR cooler effectiveness of the case with catalyst of pt 30g/ft3 decreased just up to 5%. This value was 45% less compared to the case without catalyst which decreased up to 9% after 10hours experiments.

Measurement Study at Korean, Cheju Island during March-April, 1994: (II) Characteristics of Gaseous Air Pollutants (고산에서의 1994년 3월 - 4월 측정연구: (II) 기체상 대기오염물질의 특성)

  • 김용표;김진영;박세옥;김성주;심상규;문길주;박경윤;허철구
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.91-99
    • /
    • 1996
  • Ozone, sulfur dioxide, and nitrogen oxides were measured at Kosan, Cheju Island, Korea during the period of March 11 .sim. April 19, 1994. During the measurement period, the average SO$_{2}$ and NOx concentrations were about 0.97 ppb and 3.5 ppb, respectively. Average NO concentration was below the detection limit and thus the effect of NO during the period was negligible. The concentrations of SO$_{2}$ and Nox were lower than those at other urban area in Korea but higher than other remote areas in the world. Average $O_{3}$ concentration for the period was about 55 ppb, slightly higher than or comparable to those at remote marine areas in the world. Detailed analyses of trend of gaseous species concentrations show that the effects of local NO emission sources for NOx concentration were significant during the period, while those of local SO$_{2}$ emission sources were not high. Backward trajectory analysis results show that when SO$_{2}$ or $O_{3}$ concentration was higher than the average concentrations, the air parcels were transported from China.

  • PDF

Simulation Study of NOx Dispersion from Power Plant Stack Gas (화력발전소 배출가스 중 질소산화물의 확산에 관한 연구)

  • Park, Mi-Jeong;Jo, Young-Min;Sung, Doo-Yong;Kim, Mi-Jeong;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.540-550
    • /
    • 2013
  • Various efforts have been explored to save the cost in many industrial fields. In order to recover the residual thermal energy from the flue gas, an extreme high efficiency heat exchanger is planning to install at a power plant. The gas temperature will be reduced to $40^{\circ}C$ from $115^{\circ}C$. Thus gas buoyancy decreases, and dispersion of nitrogen oxides is expected to deteriorate as increasing relative humidity. In this study, the conversion of nitrogen monoxide to nitrogen dioxide and dispersion regime are investigated through computational modeling. Nitrogen dioxide which indicates 0.1 ppm at 85 m from the ground could be propagated to 620 m at $115^{\circ}C$ of the flue gas, whilst when cooled down to $40^{\circ}C$, it expands up to 750 m. The ground level influence area showed more expansion of dispersion, approximately to 930 m.

Improvement in Reduction Performance of LNT-Catalyst System with Micro-Reformer in Diesel Engine (연료 개질장치의 적용에 따른 디젤 LNT 환원성능 개선 특성)

  • Park, Cheol-Woong;Kim, Chang-Gi;Kim, Kwan-Tae;Lee, Dae-Hoon;Song, Young-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.7
    • /
    • pp.689-696
    • /
    • 2010
  • The Because of its high thermal efficiency, the direct injection (DI) diesel engine has emerged as a promising potential candidate in the field of transportation. However, the amount of nitrogen oxides ($NO_x$) increases in the local high-temperature regions and that of particulate matter (PM) increases in the diffusion flame region during diesel combustion. In the de-$NO_x$ system the Lean $NO_x$ Trap (LNT) catalyst is used, which absorbs $NO_x$ under lean exhaust gas conditions and releases it in rich conditions. This technology can provide a high $NO_x$-conversion efficiency, but the right amount of reducing agent should be supplied to the catalytic converter at the right time. In this research, the emission characteristics of a diesel engine equipped with a micro-reformer that acts as a reductants-supplying equipment were investigated using an LNT system, and the effects of the exhaust-gas temperature were also studied.

Nitrogen Oxides Removal Characteristics of SNCR-SCR Hybrid System (SNCR-SCR 하이브리드 시스템의 질소산화물 제거 특성)

  • Cha, Jin Sun;Park, Sung Hoon;Jeon, Jong-Ki;Park, Young-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.22 no.6
    • /
    • pp.658-663
    • /
    • 2011
  • The SNCR-SCR (selective non-catalytic reduction-selective catalytic reduction) hybrid system is an economical NOx removal system. In this study, the effect of the operating parameters of the SNCR-SCR hybrid system on NOx removal efficiency was investigated. When the SNCR reactor was operated at a temperature lower than the optimum temperature ($900{\sim}950^{\circ}C$), an additional NO removal is obtained basesd on the utilization of $NH_3$ slip. On the other hand, the SNCR reactor operated above the temperature resulted in no additional NO removal of SCR due to decomposition of $NH_3$. Therefore, the SNCR process should be operated at optimum temperature to obtain high NO removal efficiency and low $NH_3$ slip. Thus, it is important to adjust NSR (normalized stoichiometric ratio) so that $SR_{RES}$ can be maintained at an appropriate level.

Experiment on Reduction of Pollutants in Titanium Dioxide Photocatalytic Ventilation System (이산화티탄 광촉매 환기장치의 오염물질 저감 실험)

  • Song, Yong Woo
    • Land and Housing Review
    • /
    • v.13 no.2
    • /
    • pp.117-123
    • /
    • 2022
  • In this study, titanium dioxide photocatalyst was applied to the ventilation system to reduce particulate matter and nitrogen oxides (NOx), which are representative indoor harmful substances. A reaction device capable of installing an ultraviolet lamp was designed and manufactured so that the pollutant decomposition effect of the titanium dioxide photocatalyst identified through previous studies could be applied indoors. The reaction device was used on the indoor ventilation system and applied to the Mock-Up test. As a result of the Mock-up test, the NOx reduction performance according to the change in air volume once per hour and five times per hour was confirmed. As a result, it was confirmed that as the number of ventilation increases, the NOx reduction time decreases proportionally, and the reduction performance increases.

Durability of Photocatalytic Cementitious Materials Exposed to Nitrogen Dioxide (광촉매 시멘트의 이산화질소 분해에 따른 내구성에 관한 연구)

  • Lee, Bo Yeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.248-249
    • /
    • 2014
  • Photocatalytic cement is receiving attention due to its high oxidation power that oxidizes nitrogen oxides (NOx), thus contributing to clean atmospheric environment. However, there has not been a thorough investigation on durability of a parent material, cementitious material, as a result of photocatalytic reactions. In this study, durability of photocatalytic cementitious materials exposed to nitrogen dioxide (NO2) gas was examined. Titanium dioxide (TiO2) nanoparticles containing cement paste samples were exposed to cycles of NO2 with UV light, followed by wetting and drying to simulate environmental condition. The surface of samples was characterized mechanically, chemically, and visually during the cycling. The results indicate that the photocatalytic efficiency decreased with continued NO2 oxidation due to calcium carbonate formation. The pits found from SEM demonstrate that chemical deterioration have occurred, such as acid attack or leaching. In conclusion, the photocatalytic reactions and its product could alter cementitious materials chemically and mechanically which could further affect long-term durability.

  • PDF