• 제목/요약/키워드: Nitrogen Loading Rate

검색결과 166건 처리시간 0.02초

준혐기-호기 생물막 공정을 이용한 돈사폐수 처리 (Treatment of Piggery Wastewater by Anoxic-Oxic Biofilm Process)

  • 임재명;한동준
    • 환경위생공학
    • /
    • 제12권2호
    • /
    • pp.1-12
    • /
    • 1997
  • This research aims to develop biofilm process for the nutrient removal of piggery wastewater. The developed process is the four stage anoxic-oxic biofilm process with recirculation of the final effluent. In summery, the results are as follows: 1. Nitrification in the piggery wastewater built up nitrite because of the high strength ammonia nitrogen. The nitrification of nitrobacter by free ammonia was inhibited in the total ammonia nitrogen loading rate with more than 0.2 kgNH$_{3}$-N/m$^{3}$·d. 2. The maximal total ammonia nitrogen removal rate was obtained at 22$\circ $C and without being affected by the loading rate. But total oxidized nitrogen production rate was largely affected by loading rate. 3. Autooxidation by the organic limit was a cause of the phosphorus release in the aerobic biofilm process. But the phosphorus removal rate was 90 percent less than the influent phosphorus volumetric loading rate of above 0.1 kgP/m$^{3}$·d. Therefore, the phosphorus removal necessarily accompanied the influent loading rate. 4. On the anoxic-oxic BF process, the total average COD mass balance was approximately 67.6 percent. Under this condition, the COD mass removal showed that the cell synthesis and metabolism in aerobic reactor was 42.8 percent and that the denitrification in anoxic reactor was 10.7 percent, respectively.

  • PDF

암모니아 산화균 및 아나목스균의 배양을 통한 파일롯 규모 단일 아나목스 반응기의 성공적인 시운전 (Successful start-up of pilot-scale single-stage ANAMMOX reactor through cultivation of ammonia oxidizing and ANAMMOX bacteria)

  • 최대희;진양오;이철우;정진영
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.371-379
    • /
    • 2018
  • The lack of seed sludges for Ammonium Oxidizing Bacteria (AOB) and slow-growing ANaerobic AMMonium OXidation (ANAMMOX) bacteria is one of the major problem for large-scale application. In this study, $24m^3$ of single-stage SBR (Sequencing Batch Reactor) was operated to remove nitrogen from reject water using AOB and ANAMMOX bacteria cultivated from activated sludge in the field. The ANAMMOX activity was found after 44 days of cultivation in the ANAMMOX cultivation reactor, and then $0.66kg\;N/m^3/d$ of the nitrogen removal rate was achieved at $0.78kg\;N/m^3/d$ of the nitrogen loading rate at 153 days of cultivation. The AOB cultivation reactor showed $0.2kg\;N/m^3/d$ of nitrite production rate at $0.4kg\;N/m^3/d$ of nitrogen loading rate after 36 days of operation. The cultivated ANAMMOX bacteria and AOB was mixed into the single-stage SBR. The feed distribution was applied to remove total nitrogen stably in the single-stage SBR. The nitrogen removal rate in the single-stage SBR was gradually enhanced with an increase of specific activities of both AOB and ANAMMOX bacteria by showing $0.49kg\;N/m^3/d$ of the nitrogen removal rate at $0.56kg\;N/m^3/d$ of the nitrogen loading rate at 54 days of operation.

Study on the optimization of partial nitritation using air-lift granulation reactor for two stage partial nitritation/Anammox process

  • Jung, Minki;Oh, Taeseok;Jung, Kyungbong;Kim, Jaemin;Kim, Sungpyo
    • Membrane and Water Treatment
    • /
    • 제10권4호
    • /
    • pp.265-275
    • /
    • 2019
  • This study aimed to develop a compact partial nitritation step by forming granules with high Ammonia-Oxidizing Bacteria (AOB) fraction using the Air-lift Granulation Reactor (AGR) and to evaluate the feasibility of treating reject water with high ammonium content by combination with the Anammox process. The partial nitritation using AGR was achieved at high nitrogen loading rate ($2.25{\pm}0.05kg\;N\;m-3\;d^{-1}$). The important factors for successful partial nitritation at high nitrogen loading rate were relatively high pH (7.5~8), resulting in high free ammonia concentration ($1{\sim}10mg\;FA\;L^{-1}$) and highly enriched AOB granules accounting for 25% of the total bacteria population in the reactor. After the establishment of stable partial nitritation, an effluent $NO_2{^-}-N/NH_4{^+}-N$ ratio of $1.2{\pm}0.05$ was achieved, which was then fed into the Anammox reactor. A high nitrogen removal rate of $2.0k\; N\;m^{-3}\;d^{-1}$ was successfully achieved in the Anammox reactor. By controlling the nitrogen loading rate at the partial nitritation using AGR, the influent concentration ratio ($NO_2{^-}-N/NH_4{^+}-N=1.2{\pm}0.05$) required for the Anammox was controlled, thereby minimizing the inhibition effect of residual nitrite.

무산소-RBC 공정을 이용한 질소제거 특성 및 동력학적 인자 도출 (Characteristics and Biological Kinetics of Nitrogen Removal in Wastewater using Anoxic-RBC Process)

  • 최명섭;손인식
    • 한국환경과학회지
    • /
    • 제12권10호
    • /
    • pp.1085-1093
    • /
    • 2003
  • This study was conducted to investigate anoxic-RBC (rotating biological contactor) and its application in advanced municipal wastewater treatment process to remove biologically organics and ammonia nitrogen. Effluent COD and nitrogen concentration increased as the increase of volumetric loading rate. But, the concentration changes of NO$_2$$\^$-/ -N and NO$_3$$\^$-/ -N were little, as compared to COD and NH$_4$$\^$+/ -N. When the volumetric loading rate increased, COD removal efficiency and nitrification appeared very high as 96.7∼98.8% and 92.5∼98.8%, respectively. However, denitrification rate decreased to 76.2∼88.0%. These results showed that the change of volumetric loading rate affected to the denitrification rate more than COD removal efficiency or nitrification rate. The surface loading rates applied to RBC were 0.13~6.0lg COD/㎡-day and 0.312∼1.677g NH$_4$$\^$+/-N㎡-day and they were increased as the increase of volumetric loading rate. However, the nitrification rate showed higher than 90%. The thickness of the biofilm in RBC was 0.130 ∼0.141mm and the density of biofilm was 79.62∼83.78mg/㎤. They were increased as surface loading rate increased. From batch kinetic tests, the k$\_$maxH/ and k$\_$maxN/ were obtained as 1.586 g C/g VSS-day, and 0.276 g N/g VSS-day, respectively. Kinetic constants of denitrifer in anoxic reactor, Y, k$\_$e/, K$\_$s/, and k were 0.678 mg VSS/mg N, 0.0032 day$\^$-1/, 29.0 mg N/l , and 0.108 day$\^$-l/, respectively. P and K$\_$s/, values of nitrification and organics removal in RBC were 0.556 g N/㎡-day and 18.71 g COD/㎡-day, respectively.

영산호의 부영양화 평가를 위한 인부하모델의 검토 (A Study on Phosphorus Loading model for Eutrophication Response in the Yongsan Lake)

  • 류일광;이치영
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.97-104
    • /
    • 2000
  • The purpose of this is made an examination of phosphorus loading model for eutrophication response in the Yongsan lake. For the model, we measured the total amount of nutrients derived from the Yongsan river watershed, inflow rate to the Yongsan lake, water quality, and water budget from January to December in 1999. The total amount of precipitation in the Yongsan river watershed was 4,951.7$\times$10$^{6}$ ㎥/y and inflow amount was 2,569.7$\times$10$^{6}$ ㎥/y, therefore the outflow rate of the Yongsan river watershed was 51.9%. The develop loading of total nitrogen was 86,928.1kg/d and that of total phosphorus was 22,007.6kg/d at the Yongsan river watershed, But, as the inflow loading of total nitrogen was 33,962kg/d and the inflow loading of total phosphorus was 2,218kg/d to the Yongsan lake. so each infolw rate was 39.0% and 10.1%. The hydraulic residence time was 34days, total phosphorus loading [L(P)] on the surface area was 23.398g/㎥/y, the hydraulic load( $Q_{s}$) of inflow water was 74.269m/y, the reserve rate of phosphorus in the lake was 0.359, and the settinh velocity of phosphorus was 0.114m/d at the Yongsan lake. Mathematical model of phosphorus loading to estimate the responses of eutrophication at the Yongsan lake is [ $P_{j}$] = 0.838 [L(P)/Q.(1+√ $T_{w}$)$^{-1}$ ] . ] . .

  • PDF

살수식 여과조의 질산화작용에 대한 수리학적 부하량과 C/N 비의 영향 (Impacts of the Hydraulic Loading Rate and C/N Ratio on Nitrification in a Trickling Filter with Styrofoam Bead Media in Seawater)

  • 최태건;김병기;박정환
    • 한국수산과학회지
    • /
    • 제52권3호
    • /
    • pp.256-267
    • /
    • 2019
  • Styrofoam beads, which are relatively inexpensive and can provide a large specific surface area, were tested as filter media. Styrofoam beads with a diameter of $3{\pm}0.5mm$ were used; the specific surface area of the beads was $1,034m^2{\cdot}m^{-3}$. Five independent recirculating culture systems were used in the experiment. Each system consisted of one culture tank and three trickling bio-filters. Using the systems, nitrification efficiency was evaluated with respect to hydraulic loading rate (HLR) and carbon/nitrogen (C/N) ratio. The lowest ammonia and nitrogen concentrations were $0.84mg{\cdot}L^{-1}$ and $1.30mg{\cdot}L^{-1}$, respectively, observed at an HLR of $50.9m^3{\cdot}m^{-2}{\cdot}h^{-1}$. Nitrification efficiency in the culture tank was highest at a C/N ratio of 0, with ammonia and nitrite nitrogen concentrations of $0.32mg{\cdot}L^{-1}$ and $0.90mg{\cdot}L^{-1}$, respectively. Ammonia and nitrite nitrogen concentrations in the culture tank abruptly changed at C/N ratios ${\geq}3$.

유입부하가 DEPHANOX 및 Modified-DEPHANOX 공정에 미치는 영향 (Effect of Loading Rate in the Operation of DEPHANOX and Modified-DEPHANOX Processes)

  • 류홍덕;민경국;이상일
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.24-31
    • /
    • 2004
  • This study was initiated to evaluate the efficiencies of DEPHANOX and Modified-DEPHANOX, which were devoloped to enhance nitrogen removal efficiency in municipal wastewater treatment. In the results, removal efficiency of organic matters was not affected much by increased loading rate of organic matters which is contained in influent. The nitrogen removal efficiencies according to the loading rate of influent TN was decreased drastically in conditions of over $0.2kg/m^3{\cdot}day$, which is T-N loading rate, and the DEPHANOX process was affected more sensitively than the M-DEPHANOX was. When the temperature was altered from $25^{\circ}C$ to $16^{\circ}C$ at HRT 6hrs, the removal efficiency of ammonia nitrogen was still over 90% and it was concluded that both DEPHANOX and M-DEPHANOX were strong enough to endure temperature variation. Moreover, both processes showed over 90% in ammonia removal efficiencies in over HRT 5hrs, so it was concluded that they were strong in HRT variation. M-DEPHANOX process showed a higher value than DEPHANOX did in T-N removal efficiency to the extent of 4~21 %, which resulted from differency of denitrification rates and the biosorption efficiency of organic matter in both processes. In the condition of HRT less than 4hrs, concentrations of ammonia nitrogen contained in effluents and nitrification reactors, might be sensitively affected by biosorption efficiency of organic matters in first separation tank. In the effect of effluent nitrate concentration in phosphorus removal, the more effluent nitrate concentration was decreased, the more phosphorus removal efficiency was increased. This result is related to the decrease of concentration of effluent nitrate which resulted from nitrification inhibition by decreased HRT.

Entrapped Mixed Microbial Cell (EMMC) 공정을 이용한 수산물 가공 폐수처리에서 유기물 및 질소 동시제거 (Simultaneous Removal of Organic and Nitrogen in the Treatment of Fish Processing Wastewater using Entrapped Mixed Microbial Cell (EMMC) Process)

  • 정병철;박권삼;정병곤
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.492-497
    • /
    • 2006
  • Feasibility of simultaneous removal of organic materials and nitrogen in the wastewater from fisheries processing plant was evaluated using entrapped mixed microbial cell (EMMC) process. The experiment was performed using activated sludge from municipal sewage treatment plant which was immobilized with gel matrix by cellulose triacetate. It was found the stable operation at the treatment system which is composed of anoxic and oxic tank, was possible when the organic and nitrogen loading rates were increased stepwise. The organic and nitrogen loading rates were conducted from 0.65 to $1.72kgCOD/m^3/d$ and from 0.119 to $0.317kg\;T-N/m^3/d$ with four steps, respectively. The maximum nitrogen loading rate which could satisfy the regulated effluent standard of nitrogen concentration, was $0.3kg\;T-N/m^3/d$. The removal efficiency of total nitrogen was decreased apparently as increasing nitrogen loading rates, whereas the removal efficiency of ammonium nitrogen was effective at the all tested nitrogen loading rates. Therefore, it was concluded that nitrification was efficient at the system. Nitrate was removed efficiently at the anoxic tank. whereas the nitrification efficiency at the oxic tank ranged 94.0% to 96.9% at the tested loading rates. The removal efficiencies of chemical oxygen demand (COD) and those of total nitrogen at the entire system ranged from 94.2% to 96.6% and 73.4% to 83.4%, respectively.

A Submerged Membrane Bioreactor with Anoxic-oxic Recycle for the Treatment of High-strength Nitrogen Wastewater

  • Shim, Jin-Kie;Yoo, Ik-Keun;Lee, Young-Moo
    • Korean Membrane Journal
    • /
    • 제3권1호
    • /
    • pp.32-38
    • /
    • 2001
  • Using the hollow fiber membrane module in a lab-scale membrane bioreactor, the anoxic- oxic (AO) process for nitrogen removal was operated for about one year. For the influent wastewater containing 1,200-1,400 mg $1^{-1}$ of CODcr and 200-310 mg $1^{-1}$ of nitrogen, this process achieved a high quality effluent of less than 30 mgCOD $liter^{-1}$ and 50 mgN $liter^{-1}$. The removal rate of organics was above 98% at a loading rate larger than 2.5 kgCOD $m^{-3}$$d^{-1}$. When the internal recycle from the oxic to the anoxic reactor changed room 2n to 600% rout the influent flow rate, the nitrogen removal rate increased from about 70 to 90% at a loading rate of 0.4 kgT-N m-s d-1. The initial increase of transmembrane pressure (TMP) was observed after a 4-month operation while maintaining the flux and MLSS concentration at 7-9 1 $m^2$ $h^{-1}$ and 6,000-14,000 mg $1^{-1}$, respectively. The TMP could be maintained below 15 cmHg for an 8-month operation. The chemical cleaning with an acid followed by an immersion in an alkali solution gave better cleaning result with the membrane operated for 10 month rather than that only by an alkali immersion.

  • PDF

회전원판공정과 화학침전공정 조합을 이용한 유기물과 질소*인의 동시제거 (Integrated System of RBC-lime Precipiatation for Simultaneous Removal of Organics and Nutrients)

  • 박종안;허준무;손부순
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.132-140
    • /
    • 1998
  • 회전원판공정(rotating biological contactorRBC)과 화학적 처리공정을 결합한 처리시스템을 이용하여 도시하수내 포함된 유기물과 영양염류를 제거할 경우에 수리학적 부하 (hydraulic loading)와 처리수 반송율 (recirculation rate)의 시스템 처리효율에 미치는 영향을 알아보고자 하였다. 각각의 수리학적 부하 0.031, 0.0535 및 0.076 $m^3/m^2/d에서 반송율을 100%, 200%, 300%로 변화시켰고, 질산화에 필요한 알카리도의 보충 및 화학적 처리를 위하여 lime(CaCO$_3$)을 가하여 유입수의 pH를 10.4-11.0으로 유지시켰다. 실험결과 수리학적 부하 0.0535 $m^3/m^2/d에서 BOD, COD의 제거효율이 가장 높게 나타났으며, 질산화 효율 및 질소 제거효율에서는 수리학작 부하 0.035 $m^3/m^2/d, 반송율 300%에서 가장 높았으며, 반송율별에서는 수리학적 부하를 고려할 때 300% 반송하는 것이 가장 높은 유기물 제거효율을 보였다. 반송율과 수리학적 부하를 증가시킬 경우에 발생되는 슬러지내 유기물 함량은 점점 증가하였고, 수리학적 부하 0.076 $m^3/m^2/d, 반송율 300%일 경우에는 유기물 함량이 47%로 매우 높았다. 이는 부하증가에 따른 미생물 성장의 증가와 더불어 수리학적 부하 증가에 따른 전단력의 증가가 영향을 미쳤기 때문이다. 인을 제거하기 위하여 pH를 10.4-11.0으로 유지시킨 경우에 인을 90%이상 제거할 수 있었으며, 유출수내 평균 SS농도는 40 mg/l를 상회하였다.

  • PDF