• Title/Summary/Keyword: Nitrogen Generator

Search Result 55, Processing Time 0.026 seconds

The Localization Development for Korean Utility Helicopter's On-Board Inert Gas Generation System (한국형 기동헬기 불활성가스발생장치 국산화 개발)

  • Ahn, Jong-Moo;Lee, Hee-Rang;Kang, Tae-Woo;Choi, Jae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.662-669
    • /
    • 2017
  • Military rotary aircraft are heavily exposed to projectile environments due to their mission characteristics, and fires caused by fuel leaks after shooting are linked directly to the loss of human life. To improve the survivability of pilots and crews, the fuel tank in rotary aircraft must have gunfire resistance and anti-explosion characteristics. Gunfire resistance can be satisfied by applying a self-sealing cell to a fuel tank. Anti-explosion can be satisfied by reducing the oxygen concentration in an explosive area and suppressing the generation of combustible fuel vapor by minimizing the evaporation rate of the fuel by heat. A Korean utility helicopter applies anon-board inert gas generation system to meet the anti-explosion requirements for ballistic impact. The generator fills the fuel tank with an inert gas and reduces the oxygen concentration. This paper describes the overall development process of the OBIGGS developed in accordance with the localization process of weapon components. OBIGGS was developed/manufactured through domestic technology, and the performance was found to be equal to or better than that of the existing products through single performance tests and aircraft mounting tests.

Operating Conditions Proposal of Bandgap Circuit at Cryogenic Temperature for Signal Processing of Infrared Detector and a Performance Analysis of a Manufactured Chip (적외선 탐색기 신호처리를 위한 극저온 밴드갭 회로 동작 조건 제안 및 제작된 칩의 성능 분석)

  • Kim Yon Kyu;Kang Sang-Gu;Lee Hee-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.12
    • /
    • pp.59-65
    • /
    • 2004
  • A stable reference voltage generator is necessary to the infrared image signal readout circuit(ROIC) to improve noise characteristics of signal originated from infrared devices, that is, to gain good images. In this paper, bandgap circuit operating at cryogenic temperature of 77K for Infrared image ROIC(readout integrated circuit) was first made. It demonstrates practical use possibility through taking measurements and estimations. Bandgap circuit is a representative voltage reference circuit. Most of bandgap reference circuits which are presented so far operate at room temperature, and their characteristic are not suitable for infrared image ROIC operating at liquid nitrogen temperature, 77K. To design bandgap circuit operating at cryogenic temperature, suitable circuit is selected and the parameter characteristics of used devices as temperature change are seen by a theoretical study and fitted at liquid temperature with considering such characteristics. This circuit has been fabricated in the Hynix 0.6um standard CMOS process, and the output voltage measured shows that the stability is 1.042±0.0015V over the temperature range of 60K to 110K and is better than bandgap circuits operated at room temperature.

Comparative Study on the Efficiency Test Using Remodeled Bubble Generating Pump for Aquarium Fish and Established Air Sampling Pump (관상어용 기포발생기를 개조한 시료채취 장치와 기존의 시료채취기와의 성능 비교)

  • Jang, Bong-Ki;Chun, Jae-Young;Son, Bu-Soon;Lee, Jong-Wha;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.183-191
    • /
    • 2005
  • This study is designed to compare the performance of established samplers (personal air sampler and MiniVOL portable air sampler) commonly used in the air environment or work environment with that of the sampler made by remodeling the air bubble generator for aquarium fishes. Sampling method used in this study is the filter collection method for PM10 and total suspended particles (TSP), the liquid collection method for sulfur dioxide ($SO_2$) and nitrogen dioxide ($NO_2$), and the solid collection method for toluene, respectively. There is not a significant difference in the average concentration of TSP between the Gilian personal air sampler (1st, $0.316{\pm}0.095$; 2nd $0.191{\pm}0.090$; 3rd, $0.185{\pm}0.073mg/m^3$) and the remodeled sampler (1st, $0.317{\pm}0.106$, 2nd $0.201{\pm}0.050$; 3rd $0.189{\pm}0.081mg/m^3$). There are also not significant differences in the average concentration of PM10 among the Gilian personal air sampler ($0.058{\pm}0.006mg/m^3$), the remodeled sampler ($0.052{\pm}0.008mg/m^3$) and the MiniVOL portable air sampler ($0.054{\pm}0.007mg/m^3$). The average concentration of the SO2 by the established sampler and the remodeled one is $3.79{\pm}0.21ppb$ and $3.45{\pm}0.15ppb$, respectively. In addition, there are not sigmficant differences in the average concentration of the NO2 between the Gilian personal air sampler (1st, $0.325{\pm}0.068$; 2nd $0.341{\pm}0.206$; 3rd, $2.971{\pm}0.078{\mu}g/m^3$) and the remodeled sampler (1st, $0.300{\pm}0.062$; 2nd $0.332{\pm}0.144$, 3rd, $2.968{\pm}0.085{\mu}g/m^3$). There are not significant differences in the average concentration of toluene between the Gilian personal air sampler (1st, $0.499{\pm}0.072$; 2nd $0.598{\pm}0.112$; 3rd $2.284{\pm}0.077{\mu}g/m^3$) and the remodeled sampler (1st, $0.463{\pm}0.133$; 2nd $0.603{\pm}0.082$; 3rd $2.353{\pm}0.115{\mu}g/m^3$). From these results, we can conclude that the performance of the remodeled sampler is not different from that of established samplers. There is possibility that the remodeled sampler can be used as a alternative device for Gilian personal air sampler in area and personal air sampling.

Surface treatment of polysaccharide by flexible active species generator (플렉서블 활성종 발생기를 이용한 다당류 표면처리)

  • Lee, Yu-Ri;Lee, Seung-Hun;Kim, Do-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.39-39
    • /
    • 2018
  • 최근 플라즈마 의학이 발달하면서 제트, 펜, 니들, 토치 등의 다양한 형태의 플라즈마 발생기가 개발되었으며 내부의 가스라인으로 가스의 종류, 유속, 조성 등을 조절하여 생물학적 효과를 극대화 할 수 있고 안정적으로 플라즈마 방전상태를 유지할 수 있으나 처리 면적이 좁아 실제 생물학적 시스템 (세포, 조직, 그리고 박테리아) 적용에 있어 한계점이 존재한다. 이러한 한계점을 극복하기 위해서 유전체격벽방전 (Dielectric barrier discharge, DBD) 방식을 이용한 플렉서블 활성종 발생기를 제작하고 생물학적 시스템에 적용하기 위한 방전 특성 평가를 진행하였으며, 간단한 in vitro 모델인 한천 젤을 이용하여 플라즈마 처리에 따른 전달물질의 침투거리를 확인하였다. 플라즈마 방전 시 생성되는 수산화기 [OH], 과산화수소 [$H_2O_2$], 초산소음이온 [$O_2{^-}$], 오존 [$O_3$], 그리고 산화질소 [$NO_x$]와 같은 산소 및 질소 활성종 (Reactive oxygen and nitrogen species, RONS)은 세포벽 또는 세포막의 주요 구성성분인 다당류와 인지질의 과산화 반응을 통해 구조를 변화시키고 생물학적 시스템의 표면의 pH를 낮춘다. 이러한 RONS의 작용은 살균, 소독 뿐만 아니라 약물의 침투를 돕는다. 일반적으로 한천 겔은 농도에 따라 생체 내 뇌 조직과 물리적 특성이 유사하고, 미생물학 기질, 방사선학 연구를 위한 조직모델로 사용되기 때문에 본 연구에서는 3%와 5% 농도의 한천 젤을 사용하여 침투거리를 확인하였다. 한천 젤은 $2.5{\times}2.5{\times}2.5cm^3$의 크기로 준비되었고 대조군으로 염료가 포함된 에멀젼을 0.01 g 도포하고, 실온에서 30분간 보존 후 단면을 잘라 현미경으로 침투거리를 확인하였으며, 실험군으로 플라즈마 전처리 후 에멀젼을 도포한 시표와 에멀젼 도포 후 플라즈마 처리한 시료에 대해 에멀젼 침투거리의 변화를 확인하였다. 본 연구의 플렉서블 활성종 발생기는 인체에 부착하여 사용되기 때문에 화상, 홍반을 유발을 방지하기위해 $40^{\circ}C$의 온도에서 실험을 진행하였고 이때에 플라즈마 방전조건은 $0.065W/cm^2$ 수준의 전력을 소모하는 1.7 kV의 전압, 16 kHz의 주파수로 10분간 처리하였다. 그 결과 3%의 한천 젤의 경우 침투거리 0.779 mm에서 0.826 mm, 0.942 mm까지 침투거리가 증가하였고 5%의 한천 젤의 경우 0.859 mm, 0.949 mm로 증가하였다. 이러한 침투거리 증가는 젤 표면의 다당류를 구성하고 있는 단량체가 플라즈마 처리시 화확적 구조가 끊어져 결론적으로 약물 침투가 증가된 것으로 판단된다.

  • PDF

Modeling and analysis of selected organization for economic cooperation and development PKL-3 station blackout experiments using TRACE

  • Mukin, Roman;Clifford, Ivor;Zerkak, Omar;Ferroukhi, Hakim
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.356-367
    • /
    • 2018
  • A series of tests dedicated to station blackout (SBO) accident scenarios have been recently performed at the $Prim{\ddot{a}}rkreislauf-Versuchsanlage$ (primary coolant loop test facility; PKL) facility in the framework of the OECD/NEA PKL-3 project. These investigations address current safety issues related to beyond design basis accident transients with significant core heat up. This work presents a detailed analysis using the best estimate thermal-hydraulic code TRACE (v5.0 Patch4) of different SBO scenarios conducted at the PKL facility; failures of high- and low-pressure safety injection systems together with steam generator (SG) feedwater supply are considered, thus calling for adequate accident management actions and timely implementation of alternative emergency cooling procedures to prevent core meltdown. The presented analysis evaluates the capability of the applied TRACE model of the PKL facility to correctly capture the sequences of events in the different SBO scenarios, namely the SBO tests H2.1, H2.2 run 1 and H2.2 run 2, including symmetric or asymmetric secondary side depressurization, primary side depressurization, accumulator (ACC) injection in the cold legs and secondary side feeding with mobile pump and/or primary side emergency core coolant injection from the fuel pool cooling pump. This study is focused specifically on the prediction of the core exit temperature, which drives the execution of the most relevant accident management actions. This work presents, in particular, the key improvements made to the TRACE model that helped to improve the code predictions, including the modeling of dynamical heat losses, the nodalization of SGs' heat exchanger tubes and the ACCs. Another relevant aspect of this work is to evaluate how well the model simulations of the three different scenarios qualitatively and quantitatively capture the trends and results exhibited by the actual experiments. For instance, how the number of SGs considered for secondary side depressurization affects the heat transfer from primary side; how the discharge capacity of the pressurizer relief valve affects the dynamics of the transient; how ACC initial pressure and nitrogen release affect the grace time between ACC injection and subsequent core heat up; and how well the alternative feeding modes of the secondary and/or primary side with mobile injection pumps affect core quenching and ensure stable long-term core cooling under controlled boiling conditions.