• Title/Summary/Keyword: Nitrate ion

검색결과 337건 처리시간 0.022초

Performance evaluation of nitrate removal in high TDS wet scrubber wastewater by ion exchange resin with dissolved air flotation (DAF) process

  • Kim, Bongchul;Yeo, Inseol;Park, Chan-gyu
    • Membrane and Water Treatment
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2022
  • The regulations of the International Maritime Organization (IMO) have been steadily strengthened in ship emissions. Accordingly, there is a growing need for development of related technologies for the removal of contaminants that may occur during the treatment of SOx and NOx using a wet scrubber. However, this system also leads to wastewater production when the exhaust gas is scrubbed. In this research, we evaluated the performance of an ion selective resin process in accordance with scrubber wastewater discharge regulations, specifically nitrate discharge, by the IMO. Accelerated real and synthetic wastewater of wet scrubbers, contained high amounts of TDS with high nitrate, is used as feed water in lab scale systems. Furthermore, a pilot scale dissolved air flotation (DAF) using microbubble generator with ion exchange resin process was combined and developed in order to apply for the treatment of wet scrubber wastewater. The results of the present study revealed that operating conditions, such as resin property, bed volume (BV), and inlet wastewater flow rate, significantly affect the removal performance. Finally, through a pilot test, DAF with ion exchange resin process showed a noticeable improvement of the nitrate removal rate compared to the single DAF process.

이온교환법에 의한 탈질소 공정개발의 기초연구(II) (Basic Study for Development of Denitrogenation Process by ion Exchange(II))

  • 이민규;주창식
    • 한국환경과학회지
    • /
    • 제7권1호
    • /
    • pp.89-95
    • /
    • 1998
  • Ion exchange performance to remove nitrate in water was studied using commercially available strong base anion exchange resin of Cl- type in the batch and continuous column reactors. The performance was tested using the effluent concentration histories for continuous column or equilibrium conquilibrium between resin and solution. Anion exchange resin used in this study was more effective than activated carbon or zeolite for nitrate removal. With large resin amount or low initial concentration, nitrate removal characteristics for a typical gel-type resin was Increased. On considering the relation between the breakthrough capacity and nitrate concentration of the influent, the use of anion exchange resin were suitable for the hi선or order water treatment. The nitrate removal of above 90% could be possible until the effluent of above 650 BV was passed to the column. Thus, the commercially available strong base anion exchange resin of $Cl^-$ type used in thins study could be effectively used as economic material for treatment of the groundwater. The breakthrough curves showed the sequence of resin selectivity as $SO_4^{2-}$ > $NO_3$ > $NO^{2-}$ > $HCO_3^-$. The results of this study could be scaled up and used as a design tool for the water purification system of the real groundwater and surface water treatment processes.

  • PDF

축전식 탈염에서 정전압과 정전류 운전에 따른 질산 이온의 선택적 제거율 비교 (Comparison of Selective Removal of Nitrate Ion in Constant Voltage and Constant Current Operation in Capacitive Deionization)

  • 최재환;김현기
    • Korean Chemical Engineering Research
    • /
    • 제53권3호
    • /
    • pp.269-275
    • /
    • 2015
  • 질산이온 선택성 탄소전극(NSCE, nitrate-selective carbon electrode)에서 전원공급 방식에 따른 이온들의 흡착특성을 분석하였다. 질산이온에 선택성이 높은 음이온수지 분말을 탄소전극에 코팅하여 NSCE를 제조하였다. 질산과 염소이온의 혼합용액에 대해 정전압(CV, constant voltage)과 정전류(CC, constant current) 모드에서 축전식 탈염(CDI, capacitive deionization)을 실시하였다. 이온들의 총 흡착량은 CV 모드로 운전한 경우 CC 모드에 비해 약 15% 증가하였다. 혼합용액에서 질산이온의 비율은 26%로 낮았지만 흡착된 질산이온의 몰비율은 최대 58%로 나타나 NSCE가 질산이온을 선택적으로 제거하는데 효과적임을 확인하였다. CC 모드에서 운전한 경우 흡착된 질산이온의 몰비율은 흡착기간 동안 55~58%로 일정하였다. 반면 CV 모드에서는 30~58%로 큰 차이를 보였다. 이를 통해 셀에 공급되는 전류가 질산이온의 선택적 제거율을 결정하는데 중요한 인자임을 알 수 있었다.

Electrochemical nitrate reduction using a cell divided by ion-exchange membrane

  • Lee, Jongkeun;Cha, Ho Young;Min, Kyung Jin;Cho, Jinwoo;Park, Ki Young
    • Membrane and Water Treatment
    • /
    • 제9권3호
    • /
    • pp.189-194
    • /
    • 2018
  • Electrochemical reduction of nitrate was studied using Zn, Cu and (Ir+Ru)-Ti cathodes and Pt/Ti anode in a cell divided by an ion exchange membrane. During electrolysis, effects of the different cathode types on operating parameters (i.e., voltage, temperature and pH), nitrate removal efficiency and by-products (i.e., nitrite and ammonia) formation were investigated. Ammonia oxidation rate in the presence of NaCl was also determined using the different ratios of hypochlorous acid to ammonia. The operating parameter values were similar for all types of cathode materials and were maintained relatively constant. Nitrate was well reduced and converted mostly to ammonia using Zn and Cu cathodes. Ammonia, produced as a by-product of nitrate reduction, was oxidized in the presence of NaCl in the electrochemical process and the oxidation performance was enhanced upon increasing the hypochlorous acid-to-ammonia ratio to 1.09:1. Zn and Cu cathodes promoted the nitrate reduction to ammonia and the produced ammonia was finally removed from solution by reacting with hypochlorite ions. Using Zn or Cu cathodes, instead of noble metal cathodes, in the electrochemical process can be an alternative technology for nitrate-containing wastewater treatment.

Bakelite A-Ni(II) 착물의 질산이온 선택성 막전극 (Nitrate Ion-Selective Membrane Electrode Based on Complex of Ammonia Modified Bakelite A-Ni(II) Nitrate)

  • 김환기;신두순
    • 대한화학회지
    • /
    • 제31권3호
    • /
    • pp.271-279
    • /
    • 1987
  • Amine기를 가진 Bakelite A와 Ni(II) 사이의 착물을 이용한 ${NO_3}^-$이온 선택성 막전극을 만들었다. 이 막전극은 $H^+$ 이온 및 2가 3가 음이온에는 감응하지 않으며, 특히 이 막전극의 재현성, 감응시간 및 이온선택성등 전기화학적 성질을 조사하여 다른 실용화된 막전극과 비교 고찰하였으며 분석화학에의 응용을 고찰하였다.

  • PDF

Enhanced ion-exchange properties of clinoptilolite to reduce the leaching of nitrate in soil

  • Kabuba, John
    • 분석과학
    • /
    • 제35권2호
    • /
    • pp.41-52
    • /
    • 2022
  • The leaching of nitrate from soil increases the concentration of elements, such as nitrogen, phosphorus, and potassium, in water, causing eutrophication. In this study, the feasibility of using clinoptilolite as an ion-exchange material to reduce nitrate leaching in soil was investigated. Soil samples were collected from three soil depths (0 - 30, 30 - 90, and 90 - 120 cm), and their sorption capacity was determined using batch experiments. The effects of contact time, initial concentration, adsorbent dosage, pH, and temperature on the removal of NO3- were investigated. The results showed that an initial concentration of 25 mg L-1, a contact time of 120 min, an adsorbent dosage of 5.0 g/100 mL, a pH of 3, and a temperature of 30 ℃ are favorable conditions. The kinetic results corresponded well with a pseudo-second-order rate equation. Intra-particle diffusion also played a significant role in the initial stage of the adsorption process. Thermodynamic studies revealed that the adsorption process is spontaneous, random, and endothermic. The results suggest that a modification of clinoptilolite effectively reduces the leaching of nitrate in soil.

RO 농축폐액의 처리를 위한 이온교환수지의 생물재생 (Bio-regeneration of Ion-exchange Resin for Treating Reverse Osmosis Concentrate)

  • 배병욱;남윤우
    • 한국물환경학회지
    • /
    • 제30권5호
    • /
    • pp.517-523
    • /
    • 2014
  • In order to remove both nitrate and sulfate present in the concentrate of RO(reverse osmosis) process, a combined bio-regeneration and ion-exchange(IX) system was studied. For this purpose, both denitrifying bacteria(DNB) and sulfate reducing bacteria(SRB) were simultaneously cultivated in a bio-reactor under anaerobic conditions. When the IX column containing a nitrate-selective A520E resin was fully exhausted by nitrate and sulfate, the IX column was bio-regenerated by pumping the supernatant of the bio-reactor, which contains MLSS concentration of $125{\pm}25mg/L$, at the flowrate of 360 BV/hr. Even though the nitrate-selective A520E resin was used, the breakthrough curves of ionic species showed that sulfate was exhausted earlier than nitrate. The reason for this result is due to the fact that the concentration of sulfate in RO concentrate was 36 to 48 times higher than nitrate. The bio-reactor was successfully operated at a volumetric loading rate of 0.6 g $COD/l{\cdot}d$, nitrate-N loading rate of 0.13 g $NO_3{^-}-N/l{\cdot}d$, and sulfate loading rate of 0.08 g $SO_4{^{2-}}/l{\cdot}d$. The removal rate of SCOD, nitrate-N, sulfate was 90, 100, and 85%, respectively. When the virgin resin was fully exhausted and consecutively bio-regenerated for 2 days, 81% of nitrate and 93% of sulfate were reduced. When the virgin resin was repeatedly used up to 4 cycles of service and bio-regeneration, the ion-exchange capacity of bio-regenerated resin decreased to 95, 91, 88, and 81% of virgin resin.

Characteristics of Mediated Enzymatic Nitrate Reduction by Gallocyanine-Bound Nanoporous Electrode

  • Kim Seung-Hwan;Song Seung-Hoon;Yoo Young-Je
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권4호
    • /
    • pp.505-510
    • /
    • 2006
  • A gallocyanine-bound nanoporous titanium dioxide electrode system was investigated to carry out a mediated enzyme reaction. Gallocyanine was bound either directly or through an aminopropylsilane linker to the film of nanoporous titanium dioxide and used as a mediator for nitrate reductase in the mediated enzymatic nitrate reduction. The electrode with the aminopropylsilane linker showed 20% higher efficiency of electron transfer at the same potential than that directly linked. The prepared electrodes showed $0.26{\mu}mol/h$ nitrate reduction at a $100mm^2$ surface of the electrode, and linear current response on nitrate ion concentration up to 1.0 mM, which is very useful as a biosensor of nitrate ion in water.

Determination of Nitrate in Chromium Plating Solution with Nitrate-Selective Electrodes

  • 강유라;이원;허황;차근식;남학현
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권3호
    • /
    • pp.221-226
    • /
    • 1995
  • A method for determining nitrate in post treatment chromium plating solutions with PVC-based nitrate-selective electrodes is described. PVC-based nitrate-selective membranes which contain TDMANO3 ion-exchanger in PVC/NPOE, PVC/DOA or PVC/DBP matrices, and a commercially available Corning electrode (No. 476134) have been compared in respect of their detection limits, response slopes, selectivities at various pHs, and dynamic response to the hydrochromate ion in basic condition. The PVC/DBP/TDMANO3 membrane electrode was chosen as the ISE detector for the determination of nitrate in the presence of hydrochromate interference. The amount of nitrate in real post treatment chromium plating solution could be determined successfully with this electrode in both static and flow-injection measurements when the sample was properly diluted with an alkaline buffer.

이온교환수지 분말이 코팅된 탄소전극을 이용한 음이온 혼합용액에서 Nitrate 이온의 선택적 제거율 향상 (Enhancement of Selective Removal of Nitrate Ions from a Mixture of Anions Using a Carbon Electrode Coated with Ion-exchange Resin Powder)

  • 여진희;최재환
    • 공업화학
    • /
    • 제24권1호
    • /
    • pp.49-54
    • /
    • 2013
  • 혼합용액에서 nitrate 이온을 선택적으로 제거하기 위해 복합탄소전극을 제조하였다. 질산이온 선택성 수지(BHP55, Bonlite Co.) 분말을 탄소전극 표면에 코팅하여 전극을 제조하였다. 제조한 전극으로 BHP55 셀을 제작하여 chloride, nitrate, sulfate 이온이 혼합된 용액에 대해 축전식 탈염 실험을 수행하였다. 그리고 BHP55 셀에서의 질산 이온 제거량을 이온교환막을 결합한 MCDI 셀의 결과와 비교하였다. BHP55 셀에서 이온의 총 흡착량은 MCDI 셀에서 보다 31% 증가한 $38.3meq/m^2$를 나타냈다. 또한 BHP55 셀에서 질산 이온의 흡착량은 $15.9meq/m^2$ (전체 흡착량의 42%)이었고, 이는 MCDI 셀에서 보다 2.1배 큰 것으로 나타났다. 실험결과 제조한 복합탄소전극은 음이온 혼합용액에서 질산 이온을 선택적으로 제거하는데 매우 효과적임을 알 수 있었다.