• Title/Summary/Keyword: Nickel-titanium file

Search Result 74, Processing Time 0.032 seconds

Effect of repetitive pecking at working length for glide path preparation using G-file

  • Ha, Jung-Hong;Jeon, Hyo-Jin;Abed, Rashid El;Chang, Seok-Woo;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.123-127
    • /
    • 2015
  • Objectives: Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi) rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. Materials and Methods: The G-file system (Micro-Mega) composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10). Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0) and 1 mm level (D1) under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05). Results: The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05). Conclusions: Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO) size 20, without apical transportation at D0 level.

Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals

  • Ha, Jung-Hong;Park, Sang-Shin
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.4
    • /
    • pp.215-219
    • /
    • 2012
  • Objectives: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer) were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results: Group 4 showed lowest screw-in effect ($2.796{\pm}0.134$) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.

Screw-in forces during instrumentation by various file systems

  • Ha, Jung-Hong;Kwak, Sang Won;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.4
    • /
    • pp.304-309
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Materials and Methods: Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS-k, DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Results: Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest (p < 0.05). Conclusions: Geometrical differences rather than shaping motion and alloys may affect the screw-in force during canal instrumentation. To reduce screw-in forces, the use of NiTi files with smaller cross-sectional area for higher flexibility is recommended.

ABILITY OF NICKEL-TITANIUM FILES IN MAINTAINING THE ORIGINAL CURVATURE OF A CURVED ROOT CANAL AND ITS ANALYSIS BY FINITE ELEMENT METHODS (만곡 근관 형성시 니켈-티타늄 파일의 만곡 유지 능력과 그에 대한 유한요소법적 분석)

  • Park, Han-Soo;Lim, Sung-Sam;Bae, Kwang-Shik;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.220-227
    • /
    • 1997
  • The purpose of our study is to evaluate the ability of nickel-titanium(NiTi) files in maintaining the original curvature of a curved root canal during canal preparation. Curved canals on translucent resin blocks were prepared with NiTi and stainless steel files, and they were placed at the platform which can reproduce the same position. The unprepared and prepared canal forms were accurately compared by double exposure technique of photography. By finite element methods we also analyzed stress distributions of NiTi and stainless steel files in a curved canal. The results were as follows : 1. NiTi files were excellent in maintaining the original curvature of a curved canal than stainless steel files after canal preparation. 2. The results of canal preparation with these files were well verified by the analysis of stress distributions using finite element methods.

  • PDF

Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments

  • Ozyurek, Taha;Tek, Vildan;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.332-341
    • /
    • 2017
  • Objectives: To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. Materials and Methods: The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with ${\chi}^2$ tests using SPSS 21.0 software. Results: New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. Conclusions: This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

Comparison of mechanical properties of nickel-titanium rotary files: Aurum Blue vs. Aurum Pro (니켈티타늄 전동 파일의 기계적 특성 비교: Aurum Blue vs. Aurum Pro)

  • Kwak, Sang Won;Ha, Jung-Hong;Ahn, Sang Mi;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.57 no.11
    • /
    • pp.672-678
    • /
    • 2019
  • AIM: The purpose of this study was to evaluate and compare the torsional fracture resistances, cyclic fatigue resistance, and bending stiffness of two nickel-titanium (NiTi) rotary instruments made of different heat-treated alloy: Aurum Blue (heat-treated) and Aurum Pro (conventional). Methods: Forty-five Aurum Blue and Aurum Pro NiTi files were selected for the three mechanical tests (n=15). For the torsional resistance test, 3 mm file tip was fixed and the shaft was driven clockwise at 2 rpm until fracture occurred by using a customized device. Cyclic fatigue resistance was evaluated by rotating instruments in artificial canal with dynamic mode. Bending stiffness was tested by observation of the bending moment on attaining a 45° bend. The results were analyzed by student-t tests at a significance level of 95%. The fractured surface of each groups were examined under a scanning electron microscope (SEM). Results: Aurum Blue showed significantly higher toughness, ultimate strength, distortion angle, and number of cycles to failure than those of Aurum Pro (p < 0.05). However, Aurum Blue and Aurum Pro did not differ significantly in terms of bending stiffness. SEM showed typical topographic appearances of the cyclic fatigue and torsional fracture. Conclusions: Under the limitations of this study, heat-treated instruments showed higher flexibility and fracture resistances than conventional NiTi instruments.

  • PDF

A survey of experience-based preference of Nickel-Titanium rotary files and incidence of fracture among general dentists

  • Lee, WooCheol;Song, Minju;Kim, Euiseong;Lee, Hyojin;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • Objectives: The purpose was to investigate the preference and usage technique of NiTi rotary instruments and to retrieve data on the frequency of re-use and the estimated incidence of file separation in the clinical practice among general dentists. Materials and Methods: A survey was disseminated via e-mail and on-site to 673 general dentists. The correlation between the operator's experience or preferred technique and frequency of re-use or incidence of file fracture was assessed. Results: A total of 348 dentists (51.7%) responded. The most frequently used NiTi instruments was ProFile (39.8%) followed by ProTaper. The most preferred preparation technique was crown-down (44.6%). 54.3% of the respondents re-used NiTi files more than 10 times. There was a significant correlation between experience with NiTi files and the number of re-uses (p = 0.0025). 54.6% of the respondents estimated experiencing file separation less than 5 times per year. The frequency of separation was significantly correlated with the instrumentation technique (p = 0.0003). Conclusions: A large number of general dentists in Korea prefer to re-use NiTi rotary files. As their experience with NiTi files increased, the number of re-uses increased, while the frequency of breakage decreased. Operators who adopt the hybrid technique showed less tendency of separation even with the increased number of re-use.

Effect of adaptive motion on cyclic fatigue resistance of a nickel titanium instrument designed for retreatment

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.34-38
    • /
    • 2017
  • Objectives: The aim of this study was to evaluate the cyclic fatigue resistance of the ProTaper Universal D1 file (Dentsply Maillefer) under continuous and adaptive motion. Materials and Methods: Forty ProTaper Universal D1 files were included in this study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which had an artificial stainless steel canal with a $60^{\circ}$ angle of curvature and a 5 mm radius of curvature. The files were randomly divided into two groups (Group 1, Rotary motion; Group 2, Adaptive motion). The time to failure of the files were recorded in seconds. The number of cycles to failure (NCF) was calculated for each group. The data were statistically analyzed using Student's t-test. The statistical significant level was set at p < 0.05. Results: The cyclic fatigue resistance of the adaptive motion group was significantly higher than the rotary motion group (p < 0.05). Conclusion: Within the limitations of the present study, the 'Adaptive motion' significantly increased the resistance of the ProTaper Universal D1 file to cyclic facture.

A comparison of shaping ability of four nickel-titanium rotary instruments in simulated root canals

  • Yun, Hyung-Hwa;Park, Jung-Won;Kim, Sung-Kyo
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.588.1-588
    • /
    • 2001
  • The purpose of this study was to compare the root canal shaping ability of four nickel-titanium rotary instruments. Forty eight simulated curved root canals were instrumented in plastic with the Crown-down technique using the $ProTaper^{TM}$ , the ProFile, the $GT^{TM}$, and the Quantec. Canals were instrumented until apical canal were up to size 30 by one operator. Each instrument was used only once and instrumentation time was measured.(omitted)

  • PDF

The effect of gutta-percha removal using nickel-titanium rotary instruments

  • Jeon, Jeong-Hun;Hwang, Ho-Keel
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.552-552
    • /
    • 2003
  • The purpose of this study was to quantify the amount of remaining gutta-percha/sealer on the walls of root canals when three types of nickel-titanium rotary instruments and a hand instrument were used to remove these materials. Forty extracted mandibular premolars were prepared by step-back method and obturated with gutta-percha and sealer. Gutta-percha removal for group 1 was done using hand file with chloroform, group 2 using Profile and group 4 using K3. The following factors were evaluated : Time taken to reach working length, total time for gutta-percha removal and number of fractured instruments.(중략)

  • PDF