• Title/Summary/Keyword: Nickel (Ni)

Search Result 1,524, Processing Time 0.029 seconds

Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal (모형 레진근관에서 니켈-티타늄 전동 파일의 경사도가 screw-in effect에 미치는 영향)

  • Sung, Hye-Jin;Ha, Jung-Hong;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.380-386
    • /
    • 2010
  • Objectives: The introduction of nickel-titanium alloy endodontic instruments has greatly simplified shaping the root canal systems. However, these new instruments have several unexpected disadvantages. One of these is tendency to screw into the canal. In this study, the influence of taper on the screw-in effect of the Ni-Ti rotary instrument were evaluated. Materials and Methods: A total of 20 simulated root canals with an S-shaped curvature in clear resin blocks were divided into two groups. ProFile .02, .04, .06 (Dentsply-Maillefer) and GT rotary files .08, .10, .12 (Dentsply) were used in Profile group, and K3 .04, .06, .08, .10, and .12 (SybronEndo, Glendora) were used in K3 group. Files were used with a single pecking motion at a constant speed of 300 rpm. A special device was made to measure the force of screw-in effect. A dynamometer of the device recorded the screwin force during simulated canal preparation and the recorded data was stored in computer with designed software. The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. p value of less than 0.05 was regarded significant. Results: The more tapered instruments generated more screw-in forces in Profile group (p < 0.05). In K3 group, 0.08, 0.10. and 0.12 tapered instruments showed more screw-in force than 0.04 tapered one, and 0.08 and 0.12 tapered instruments showed more screw-in force than 0.06 tapered one (p < 0.05). Conclusions: The more tapered instruments seems to produce more screw-in force. To avoid this screw-in force during instrumentation, more attention may be needed when using more tapered instruments.

Long-term monitoring of heavy metal contents in paddy soils (논토양 중금속 함량의 장기변동 모니터링)

  • Kim, W.I.;Kim, M.S.;Roh, K.A.;Lee, J.S.;Yun, S.G.;Park, B.J.;Jung, G.B.;Kang, C.S.;Cho, K.R.;Ahn, M.S.;Choi, S.C.;Kim, H.J.;Kim, Y.S.;Nam, Y.K.;Choi, M.T.;Moon, Y.H.;Ahn, B.K.;Kim, H.K.;Kim, H.W.;Seo, Y.J.;Kim, J.S.;Choi, Y.J.;Lee, Y.H.;Lee, S.C.;Hwang, J.J.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.3
    • /
    • pp.190-198
    • /
    • 2008
  • There is an increasing concern over heavy metal contamination of paddy soils and the subsequent translocation of heavy metals to rice. Objective is to monitor the status and long-term trend of heavy metal contamination in paddy soils, periodically. In 2007 survey, the average concentrations of As(arsenic), Cd(cadmium), Cu(copper), Ni(nickel), Pb(lead), and Zn(zinc) in 2,010 paddy soils nationwide were 0.87, 0.08, 3.33, 1.19, 4.95 and $4.67mg\;kg^{-1}$, respectively. Few sites, which were contaminated by As in 2003 and 2007 survey and by Ni in 1999 and 2007 survey, were over the threshold level for soil contamination designated by the Soil Environmental Conservation Act in Korea. Long-term change was shown that As, Ni, and Zn were gradually increased whereas Cd and Cu were decreased. In the distribution of extractable heavy metal contents, the modes of each heavy metal content were similar with the average contents of each heavy metals. Mean value of heavy metals except copper in paddy soils was higher than median value. It means that the downward distribution of heavy metal content in paddy rice was shown against normal distribution.

Pollution of Heavy Metals and Sedimentation Rate in the Sediments of Suyeong Bay, Pusan (수영만 퇴적물의 퇴적속도와 중금속 오염)

  • YANG Han-Soeb;KIM Seong-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.5
    • /
    • pp.643-658
    • /
    • 1994
  • The sedimentary records of anthropogenic metal loads in the Suyeong Bay, Pusan were determined by combining the Pb-210 dating technique with the measurements of heavy metals in the sediment cores. The sedimentation rates of sediment particles ranged from $0.12\;to\;0.20\;g/m^2/yr\;or\;2.4{\sim}4.0\;mm/yr$ in accumulation rates. The lowest sedimentation rate was observed at station S3 which was characterized by a bottom with relatively low organic matter contents(e.g. TIL and TOC). Heavy metals showed generally higher concentrations at station S1 and S2 near the mouth of the Suyeong River than at station S3 and the outmost station S4. The contents of copper, lead and zinc in the sediment cores especially from station S1 and S2 began to increase around 1930, and were at their highest levels in the $1960{\sim}1970$ period as a result of increasing industrial activities. Concentrations of these heavy metals have slightly decreased since 1970, probably due to regulation of pollution discharge. The natural background levels of copper, lead and zinc in the sediments of this bay ranged $18{\pm}4ppm,\;28{\pm}6ppm\;and\;74{\pm}9ppm$, respectively, by averaging the contents in the sediment depths corresponding to periods between about 1900 and 1920 at the four stations. The total amounts of anthropogenic loads deposited in the sediments since about 1930 were estimated to be $9{\sim}291{mu}g/cm^2$ for lead, $165{\sim}1122{mu}g/cm^2$ for zinc and $20{\sim}208{mu}g/cm^2$ for copper. These values were remarkably high at stations S1 and S2 relative to the other two stations. At stations S1 and S2, the anthropogenic loads of lead, copper and zinc constituted $29{\sim}30\%,\;32{\sim}42\%\;and\;28{\sim}35\%$ of the total sedimentary inventories at the present day, respectively. These metal contents have a good correlation(r>0.7) with each other and cadmium measurements also show a positive linear relation with nickel or total organic nitrogen.

  • PDF

Comparison of shaping ability using various Nickel-Titanium rotary files and hybrid technique (다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효율 비교)

  • Kim, Jung-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.530-541
    • /
    • 2007
  • Currently, various Nickel-Titanium rotary files are used in endodontic treatment, but there is no one perfect system that can be applied to any clinical situation. Therefore, the combined uses of various file systems which can emphasize the advantages of each system are introduced as hybrid instrumentation. The ProTaper system is efficient in body shaping and apical pre-enlargement but is reported to have more possibility of transportation and produce more aberrations and deformation in more or less severe curved canals. Recently, new ProTaper system(ProTaper Universal) with different configuration and cross-sectional design to overcome the week points of ProTaper have been marketed. The purpose of this study was to compare and evaluate the shaping abilities of ProTaper, ProTaper Universal system, and two hybrid methods using S-series of ProTaper Universal and Hero Shaper or ProFile. The time lapses for instrumentation were measured and the used files were inspected for distortion. The pre- and post-instrumented root canals were scanned and superimposed to evaluate the aberrations and reduction of root canal curvature and change of radius of canal curvature. The increased canal width and apical centering ratio were calculated at 1, 2, 3, 4 and 5 mm levels from apical foramen. Under the conditions of this study, the ProTaper Universal seems to have better shaping ability than ProTaper in terms of instrumented width and instrumentation time. It may be suggested that the ProTaper Universal system is efficient as much as hybrid instrumentation using ProTaper and other constant-tapered NiTi file systems in highly experienced operators.

The Significance of the Distribution Patterns of Certain Elements in the Stream Sediments' of the St. Austell Granite Mass, Cornwall (영국(英國)콘웰주(州)의 성(聖)오우스텔 화강암괴(花崗岩塊)에 대(對)한 지구화학적(地球化學的) 연구(硏究))

  • Lee, Jae Yeong;Olinze, Simon Kaine
    • Economic and Environmental Geology
    • /
    • v.2 no.4
    • /
    • pp.23-71
    • /
    • 1969
  • Sediment samples were taken at about half-mile intervals from all the inajor rivers draining the St. Austell granite mass. The minus 80 mesh(B.S.S.) fraction of each sample was analysed, using semiquantitative methods, for sodium, potassium, lithium, phosphorus, nickel, chromium, tin, tungsten, arsenic copper, zinc and lead. The work was carried out with the view to gaining further information as to the geographical distribution of such different granite facies as might axist, and to investigate the geochemical dispersion of these elements with relation to mineralisation in this area. The sesults confirm Exley's suggestion that the mass consists of two major granite intrusions, the earlier undifferentiated one is joined on the west by a later differentiated intrutive. During the work grid deviation maps proved particularly useful in obtaining data concerning the nature of the granite but frequency diagrams were not particularly helpful. All the known lode areas were associated with stream sediments containing anomalously high concentrations of lode metals and it is concluded that these high concentrations are due premarily to lode material transferred to the streams in the form of tailings lost during milling operations.

  • PDF

Histologic and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants (Self drilling과 Self-tapping microscrew implants의 조직학적 및 생역학적인 비교)

  • Park, Hyo-Sang;Yen, Shue;Jeoung, Seong-Hwa
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.295-307
    • /
    • 2006
  • Objective: The purpose of this study was to compare the histological and biomechanical characteristics of self-tapping and self-drilling microscrew implants. Methods: 112 microscrew implants (56 self-drilling and 56 self-tapping) were placed into the tibia of 28 rabbits. The implants were loaded immediately with no force, light (100 gm), or heavy force (200 gm) with nickel-titanium coil springs. The animals were sacrificed at 3- and 5-weeks after placement and histologic and histomorphometric analysis were performed under a microscope. Results: All microscrew implants stayed firm throughout the experiment. There was no significant difference between self-drilling and self-tapping microscrew implants both in peak insertion and removal torques. Histologic examinations showed there were more defects in the self-tapping than the self-drilling microscrew implants, and newly formed immature bone was increased at the interface in the self-tapping 5-week group. There was proliferation of bone towards the outer surface of the implant and/or toward the marrow space in the self-drilling group. Histologically, self-drilling microscrew implants provided more bone contact initially but the two methods became similar at 5 weeks. Conclusion: These results indicate the two methods can be used for microscrew implant placement, but when using self-tapping microscrew implants, it seems better to use light force in the early stages.

Materials Compatibility and Structure Optimization of Test Department Probe for Quality Test of Fingerprint Sensor (지문인식센서 품질평가를 위한 검사부 프로브의 소재 적합성과 구조 최적화 연구)

  • Son, Eun-Won;Youn, Ji Won;Kim, Dae Up;Lim, Jae-Won;Kim, Kwang-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.73-77
    • /
    • 2017
  • Recently, fingerprint sensors have widely used for personal information security, and require quality evaluation to reduce an error of their recognition rate. Quality of fingerprint sensors is evaluated by variation of their electrical resistance introducing by contacts between a probe tip and a sensor electrode, Investigation on the materials compatability and structure optimization of probe is required to reduce deformation of sensor electrode for repeatability of quality testing. Nickel, steel(SK4), beryllium copper, and phosphor bronze were considered as probe materials, and beryllium copper was the most appropriate for materials of probe tips, considering indentation and contact resistance while being contacted probe tips on electrodes. Probes of an inspection part were manufactured with the single-unit structure for physical damage prevention and parallel processing capability. Inspection repeatability was evaluated by voltage variation of fingerprint sensors when the specific current was applied. A single-unit inspection part with beryllium copper probe tips showed excellent repeatability within ${\pm}0.003V$ of its voltage variation.

Activation of Urease Apoprotein of Helicobacter pylori

  • Cho, Myung-Je;Lee, Woo-Kon;Song, Jae-Young;An, Young-Sook;Choi, Sang-Haeng;Choi, Yeo-Jeong;Park, Seong-Gyu;Choi, Mi-Young;Baik, Seung-Chul;Lee, Byung-Sang;Rhee, Kwang-Ho
    • The Journal of the Korean Society for Microbiology
    • /
    • v.34 no.6
    • /
    • pp.533-542
    • /
    • 1999
  • H. pylori produces urease abundantly amounting to 6% of total protein of bacterial mass. Urease genes are composed of a cluster of 9 genes of ureC, ureD, ureA, ureB, ureI, ureE, ureF, ureG, ureH. Production of H. pylori urease in E. coli was studied with genetic cotransformation. Structural genes ureA and ureB produce urease apoprotein in E. coli but the apoprotein has no enzymatic activity. ureC and ureD do not affect urease production nor enzyme activity ureF, ureG, and ureH are essential to produce the catalytically active H. pylori urease of structural genes (ureA and ureB) in E.coli. The kinetics of activation of H. pylori urease apoprotein were examined to understand the production of active H. pylori urease. Activation of H. pylori urease apoprotein, pH dependency, reversibility of $CO_2$ binding, irreversibility of $CO_2$ and $Ni^{2+}$ incorporation, and $CO_2$ dependency of initial rate of urease activity have been observed in vitro. The intrinsic reactivity (ko) for carbamylation of urease apoprotein co expressed with accessory genes was 17-fold greater than that of urease apoprotein expressed without accessory genes. It is concluded that accessory genes function in maximizing the carbamylating deprotonated ${\varepsilon}$-amino group of Lys 219 of urease B subunit and metallocenter of urease apoprotein is supposed to be assembled by reaction of a deprotonated protein side chain with an activating $CO_2$ molecule to generate ligands that facilitate productive nickel binding.

  • PDF

Study on the Contamination Characteristics of Pollutants at Various type of Abandoned Metal Mines (폐금속 광산의 유형별 오염특성에 관한 연구)

  • Lee, Jong-Deuk;Kim, Tae Dong;Kim, Sun Gu;Kim, Hee-Joung
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.3
    • /
    • pp.93-108
    • /
    • 2013
  • This study is aimed to prepare the effective detail survey methods(Phase II) of abandoned metal mines through the contamination assessment for mine types and facilities in the abandoned metal mine areas. The study sites of 12 abandoned mines are located in Gyeonggi-do and Gangwon-do and those were chosen among 310 sites that the Phase II survey was conducted from 2007 to 2009 after considering the results of Phase I for abandoned mines scattered all over the country. 12 study sites were classified into four types; Type I sites only have pit mouth. Type II sites have pit mouth and mine-waste field. Type III sites have pit mouth and tailing sorting field. Type IV sites have pit mouth, tailing sorting field and concentrator(s). In forest land, paddy soil and farm land of Type I, As and Cd were showed average concentration, and Cu and Pb were high on the pit mouth area in one mines where the pit mouth was developed within 500 m. In the mines of Type II, Cu and Pb were showed average concentration too, but As and Cd were slightly high in pit mouth and mine-waste field. The mines of Type III which had grinding particle process through physical separation milling or hitting showed similar tendency with Type II. However, mines of Type IV pit mouth, mine-waste field and showed various results depending on defining the contamination sources. For example, if contamination source was pit mouth, the mixed results of Type I, II, II were showed. In tailing sorting field which was regarded as the most important source and having high mobility, however, if there were no facilities or it was difficult to access directly, field sampling was missed occasionally during phase I and phase II survey. For that reason, the assessment for tailing sorting field is missed and it leads to completely different results. In the areas of Type I mines, the concentration of heavy metals exceeded precautionary standards of soil contamination or not within 1,000 meters of pit mouth. Nickel(Ni) was the largest factor of the heavy metal contamination in this type. The heavy metals except Arsenic(As) were shown high levels of concentration in Type II areas, where pit mouth and mine-waste field were operated for making powder in upriver region; therefore, to the areas in the vicinity of midstream and downstream, the high content of heavy metals were shown. The tendency of high level of heavy metals and toxic materials contained in flotation agent used during sorting process were found in soil around sorting and tailing field. In the abandoned-pit-mouth area, drygrinding area and tailing sorting field area, the content of Cupper(Cu) and Zinc(Zn) were higher than other areas. Also, the contaminated area were larger than mine reclamation area(2,000 m) and the location of tailing sorting field was one of the important factors to estimate contaminated area.

A Study on the Size of Ultrafine Particles and Heavy Metal Concentrations in the Atmosphere (일반대기 중 극미세입자와 중금속 농도에 관한 연구)

  • Cho, Tea-Jin;Jeon, Hye-Li;Youn, Hyung-Sun;Lee, Mi-Young;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.6
    • /
    • pp.480-495
    • /
    • 2010
  • This study evaluated the distribution of the concentrations of nano-particles and heavy metals (08-Pb, Cr, Zn, As, Fe, 09-Pb, Cr, Zn, Cu, Ni, Mn) in Seoul, Chungnam A and Gwangyang from August to December, in 2008 5 times each in the Seoul area, 5 times in and Chungnam A area and from August to November, in 2009 14 times in the Chungnam A area, 8 times in the Gwangyang area. The examined results showed high concentration level from $PM_1$ through $PM_{0.1}$ in all three areas. These results were obtained the concentration of particles by diameter and statistically significant in Stage5 (1.0-0.56 ${\mu}m$) from the result of conducting Kruskal-Wallis H test (p < 0.05). In the case of the heavy metal concentration included in 0.10-0.056 ${\mu}m$, 0.056 ${\mu}m$, the lead concentration of Chungnam Asan area was 6.49 ng/$m^3$ and 9.93 ng/$m^3$, which was higher than 3.05 ng/$m^3$ and 4.22 ng/$m^3$ of Seoul, respectively. The concentration of iron in Seoul was 9.28 ng/$m^3$ and 13.24 ng/$m^3$, that appeared higher than 2.38 ng/$m^3$ and 3.23 ng/$m^3$ of Chungnam A area, respectively. The concentration level was similar to other metals except lead and iron in Chungnam A area and Seoul. From the concentration of heavy metal included in 0.10-0.056 ${\mu}m$, 0.056 ${\mu}m$, the lead concentration of Chungnam A area was 0.31 ng/$m^3$ and 0.12 ng/$m^3$ while Gwangyang was 0.28 ng/$m^3$, 0.06 ng/$m^3$. Thus Chungnam A area showed higher lead concentration than Gwangyang. The manganese concentration of Chungnam A area was 0.12 ng/$m^3$ and 0.03 ng/$m^3$ while Gwangyang was 0.21 ng/$m^3$ and 0.08 ng/$m^3$. Therefore, the concentration of Gwangyang appeared higher than that of Chunnam A area. These two metals showed statistically significant in 0.056 ${\mu}m$ (p < 0.05, p < 0.01). Among the concentration of heavy metal in all regions, the result demonstrated that the order of higher concentration is arsenic > iron > zinc > chrome > lead > nickel > copper > manganese.