• Title/Summary/Keyword: Nickel (Ni)

Search Result 1,524, Processing Time 0.03 seconds

A Study on Metal Hydride Electrode of Ni/MH Battery(I) (니켈/금속수소 축전지의 금속수소 전극에 관한 연구(I))

  • Kim, Jeong-Seon;Cho, Won-Il;Cho, Byung-Won;Yun, Kyung-Suk;Kim, Sang-Ju;Shin, Chee-Burm
    • Applied Chemistry for Engineering
    • /
    • v.5 no.1
    • /
    • pp.81-89
    • /
    • 1994
  • A study on Mm type electrode which is relatively high in electrode capacity and low in material cost was performed to develope high performance nickel-metal hydride battery. The electrode characteristics were investigated by P-C-T, charge-discharge and microencapsulation treatment experiments. The plateau pressure and hydrogen absorption capacity obtained from the P-C-T experiment were 0.4 atm and 310 mAh/g, respectively. The electrode capacity and stability of microencapsulated electrode were improved than those of conductor mixed electrode and the microencapsulation was possible without pretreatment. The electrode capacity of microencapsulated Mm type alloy was 240~250 mAh/g(0.2 C).

  • PDF

Assessment of Selected Heavy Metal Concentrations in Agricultural Soils around Industrial Complexes in Southwestern Areas of Korea

  • Kim, Dong-Jin;Park, Jung-Hwon;Lee, Jin-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.5
    • /
    • pp.524-530
    • /
    • 2016
  • Agricultural soils near or around industrial complexes can contain a certain amount of heavy metals that readily enter the food chain and negatively affect human health. Therefore, we conducted the study to investigate the distribution of selected heavy metals, including arsenic (As), cadmium (Cd), chromium (Cr), nickel (Ni), lead (Pb), mercury (Hg), and zinc (Zn), in farm-land soils around fifteen industrial complexes in the southwestern provinces, Korea. The concentrations of heavy metals in the soil samples were determined by the pseudo-total aqua regia (3 HCl : $1HNO_3$) digestion procedure. The heavy metal concentrations in most soils examined did not exceed the levels of Soil Contamination Warning Standard (SCWS) for agricultural lands (Region 1) presented in Soil Environment Conservation Law (SECL) established by Ministry of Environment (MOE), Korea. However, only one sampling site showed higher As amount ($27.1mg\;kg^{-1}$) than the SCWS level of As ($25mg\;kg^{-1}$). Pollution index (PI) for heavy metals did not exceed 1.0. The PI values were significantly positively correlated (p < 0.01) with the heavy metal concentrations. In particular, the values of correlation coefficient between the Cd and Pb concentrations and the PI values were higher than those estimated from other combinations, and thus the amounts of Cd and Pb in the agricultural soils highly affected the PI values for the heavy metals.

First-principles Study of Graphene/Hexagonal Boron Nitride Stacked Layer with Intercalated Atoms

  • Sung, Dongchul;Kim, Gunn;Hong, Suklyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.185.2-185.2
    • /
    • 2014
  • We have studied the atomic and electronic structure of graphene nanoribbons (GNRs) on a hexagonal boron nitride (h-BN) sheet with intercalated atoms using first-principles calculations. The h-BN sheet is an insulator with the band gap about 6 eV and then it may a good candidate as a supporting dielectric substrate for graphene-based nanodevices. Especially, the h-BN sheet has the similar bond structure as graphene with a slightly longer lattice constant. For the computation, we use the Vienna ab initio simulation package (VASP). The generalized gradient approximation (GGA) in the form of the PBE-type parameterization is employed. The ions are described via the projector augmented wave potentials, and the cutoff energy for the plane-wave basis is set to 400 eV. To include weak van der Waals (vdW) interactions, we adopt the Grimme's DFT-D2 vdW correction based on a semi-empirical GGA-type theory. Our calculations reveal that the localized states appear at the zigzag edge of the GNR on the h-BN sheet due to the flat band of the zigzag edge at the Fermi level and the localized states rapidly decay into the bulk. The open-edged graphene with a large corrugation allows some space between graphene and h-BN sheet. Therefore, atoms or molecules can be intercalated between them. We have considered various types of atoms for intercalation. The atoms are initially placed at the edge of the GNR or inserted in between GNR and h-BN sheet to find the effect of intercalated atoms on the atomic and electronic structure of graphene. We find that the impurity atoms at the edge of GNR are more stable than in between GNR and h-BN sheet for all cases considered. The nickel atom has the lowest energy difference of ~0.2 eV, which means that it is relatively easy to intercalate the Ni atom in this structure. Finally, the magnetic properties of intercalated atoms between GNR and h-BN sheet are investigated.

  • PDF

Rcovery of Nitric acid, Copper and Nickel from Plating Waste of Automobile (자동차 휠 도금박리 폐액으로부터 용매추출법을 이용한 질산과 구리추출 및 니켈회수)

  • An, Jong-Gwan;Son, Seong-Ho;Lee, Won-Sik;Gang, Yun-Ji
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.216-218
    • /
    • 2014
  • 자동차용 고광택 크롬 도금 박리액에는 질산과 유가금속인 구리 및 니켈이 다량 함유되어 있는 것으로 알려져 있다. 질산($HNO_3$) 및 유가금속은 고가이며 유독하므로 경제적 및 친환경적으로 반드시 회수하여 재활용하여야 한다. 본 연구에서는 도금박리액으로부터 질산과 구리, 니켈을 용매 추출법을 이용하여 분리하였다. 수상에 존재하는 질산의 농도는 0.01 ~ 1N NaOH를 이용하여 적정하여 분석하고, 금속의 농도는 ICP-MS 및 ICP-AES 등을 이용하여 분석하였다. 도금 박리액을 분석한 결과 Cu(76850mg/L), Ni(51990 mg/L)이 함유되어 있음을 알 수 있었다. 용액 내 질산의 양을 NaOH 용액을 이용하여 적정법으로 측정하였을 때, 질산의 양은 대략 1.02 M 임을 알 수 있었다. 50 % Tributylphosphate (TBP)를 이용하여 3단 추출한 유기층의 용액을 증류수를 이용하여 3회의 역추출을 하였을 때, 원액으로부터 48.1 %의 질산을 회수할 수 있음을 알 수 있었으며, 순도는 99.5% 이상이었다. 질산 회수 후 용액 내에 남은 구리와 니켈은 ISE-106로 구리를 추출하여 니켈을 분리한 후 황산을 이용해 역추출 하였다. 회수된 구리는 NaOH를 이용하여 pH를 조절하고 수산화구리 형태로 침전시킨 후 $N_2H_4$를 이용하여 환원시켰고, 온도와 pH 및 환원제를 이용하여 다양한 조건 하에 구리 분말을 제조하였다. 구리를 추출하여 라피네이트 용액으로 분리된 니켈은 $NaBH_4$를 이용하여 환원시켰고, 다양한 조건 하에서 니켈 분말을 제조하였다. 환원 된 분말은 분석결과 99%의 순수한 분말임을 알 수 있었다.

  • PDF

Surface Acoustic Wave Characteristics of Piezoelectric Materials and Protein Immobilization (압전 재료의 탄성표면파 특성과 단백질의 고정화)

  • Chong, Woo-Suk;Hong, Chul-Un;Kim, Gi-Beum
    • Korean Chemical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.166-171
    • /
    • 2006
  • In this study, in using a piezoelectric material of $Pb(Mg_{1/3}Nb_{2/3})O_3-PbTiO_3$ (PMN-PT), which has a high electromechanical coupling coefficient, we have tried to study about this material can be practically available as a new biosensor to detect protein by using surface acoustic wave (SAW). As the results, the filtering of the center frequency of the PMN-PT substrate is a superior result to that of the $LiTaO_3$ (LT) substrate, but the result was not completely satisfactory. Also this study attempts to develop a sensing method to detect mismatched DNA in order to diagnose cancer. We could directly immobilize the MutS to the NTA using the EDC solution. But, we immobilized MutS using nickel and it is judged that is more effective method to detect mismatched DNA.

Design and control of a proof-of-concept active jet engine intake using shape memory alloy actuators

  • Song, Gangbing;Ma, Ning;Li, Luyu;Penney, Nick;Barr, Todd;Lee, Ho-Jun;Arnold, Steve
    • Smart Structures and Systems
    • /
    • v.7 no.1
    • /
    • pp.1-13
    • /
    • 2011
  • It has been shown in the literature that active adjustment of the intake area of a jet engine has potential to improve its fuel efficiency. This paper presents the design and control of a novel proof-of-concept active jet engine intake using Nickel-Titanium (Ni-Ti or Nitinol) shape memory alloy (SMA) wire actuators. The Nitinol SMA material is used in this research due to its advantages of high power-to-weight ratio and electrical resistive actuation. The Nitinol SMA material can be fabricated into a variety of shapes, such as strips, foils, rods and wires. In this paper, SMA wires are used due to its ability to generate a large strain: up to 6% for repeated operations. The proposed proof-of-concept engine intake employs overlapping leaves in a concentric configuration. Each leaf is mounted on a supporting bar than can rotate. The supporting bars are actuated by an SMA wire actuator in a ring configuration. Electrical resistive heating is used to actuate the SMA wire actuator and rotate the supporting bars. To enable feedback control, a laser range sensor is used to detect the movement of a leaf and therefore the radius of the intake area. Due to the hysteresis, an inherent nonlinear phenomenon associated with SMAs, a nonlinear robust controller is used to control the SMA actuators. The control design uses the sliding-mode approach and can compensate the nonlinearities associated with the SMA actuator. A proof-of-concept model is fabricated and its feedback control experiments show that the intake area can be precisely controlled using the SMA wire actuator and has the ability to reduce the area up to 25%. The experiments demonstrate the feasibility of engine intake area control using an SMA wire actuator under the proposed design.

Dental materials in patients with oral mucosal disease based on the results of patch test study (구강점막질환환자에서 치과재료를 이용한 첩포시험 결과에 대한 고찰)

  • Jeong, Sung-Hee;Kim, Ji-Su;Kim, Kyung-Hee;Ok, Soo-Min;Heo, Jun-Young;Ahn, Yong-Woo
    • The Journal of the Korean dental association
    • /
    • v.52 no.2
    • /
    • pp.96-104
    • /
    • 2014
  • The aim of this study was to investigate the frequency of positive patch test reaction to dental materials in patients with oral mucosal diseases. Epicutaneous patch test was performed in 110 patients with oral mucosal diseases; 41 patients with oral lichen planus(OLP), 44 patients with burning mouth syndrome(BMS), 25 patients with other oral mucosal diseases including recurrent aphthous ulcer and mucous membrane pemphigoid. The obtained results were as follows: Oral gold restorations were most common in patents with oral mucosal diseases and porcelain fused metal crown, implant appeared in the order. 33 of 110 patients did not appear skin reactions (negative, 30%) and 77 patients (positive, 70%) had skin reactions including redness, rash, blisters. Dental materials causing positive reaction to patch test were mainly as gold-sodium-thiosulfate (26.7%), nickel sulfate(Ni) (22.7%), cobalt chloride(Co) (14.7%), palladium chloride(Pd) (11.9%), potassium dichromate (10.7%) in order, respectively. In conclusion, old metal restorations could be the cause of oral mucosal diseases and epicutaneous patch test could be used as a tool to improve the oral conditions.

Localization Technology Development of 16oz Popper Kettle through Existing Kettle Analysis and Heating System Study (기존 케틀 분석 및 가열 시스템 연구를 통한 16oz 팝퍼 케틀 국산화 기술 개발)

  • Lee, Jung-Hun;Kim, Kyoung-Chul;Oh, Young-Sub;Ryuh, Beom-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7773-7780
    • /
    • 2015
  • Analysis of existing kettle and its heating system has been the topic for localization technology development. Test pieces are made, polished and etched for existing kettle analysis. Surface of test pieces is observed using SEM, the kettle is verified to be made by deep drawing process from Ferrite-Perlite material. The kettle is also identified to be plated $16{\sim}49{\mu}m$ of thickness with Nickel(16%). Also heat transfer characteristics based on hot wire arrangement is investigated and optimal hot wire system is developed. Developed control system detects overheating and stops the whole system on the long operating time. Developed kettle takes the performance evaluation test for volume expansion and satisfied for standard 'KS G3602'.

A Study of the Effect on Fertilization Condition on the Several Essential Elements in 2 Lettuce Cultivas (상치의 시비조건에 따른 상치내 몇 가지 미량원소의 함량에 관한 연구)

  • Kwon, O-Dal;Chung, Keun-Hi;Lee, Jin-Hi
    • Korean Journal of Organic Agriculture
    • /
    • v.7 no.1
    • /
    • pp.147-159
    • /
    • 1998
  • In order to study the effects of chemical fertilizer and organic fertilizer on the toxic mineral content in the absence or presence of the wood extraction, the lettuce an experiment of fatal 20 treatments was conducted far a peried of 10 weeks. The results obtained from the experiment are summarized as follows; 1. The mineral contents of the lettuce in the wood extraction-treated group and the wood extraction non-treated group showed no conspicious differenves. 2. These are no prominent differences in the mineal contents(Chromium, Nickel, Lead, and Aluminium) in the lettuce between the organic fertifized group and the lettuce raised in the chemical fertilized group. 3. Mercury was not detected in all samples of lettuces raised in all treatments.4. Cadmium contents in the lettuce samples were increased as the amount of organic fertilizer was increased from 25% to 100%.

  • PDF

Buckling resistance, bending stiffness, and torsional resistance of various instruments for canal exploration and glide path preparation

  • Kwak, Sang-Won;Ha, Jung-Hong;Lee, WooCheol;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.270-275
    • /
    • 2014
  • Objectives: This study compared the mechanical properties of various instruments for canal exploration and glide-path preparations. Materials and Methods: The buckling resistance, bending stiffness, ultimate torsional strength, and fracture angle under torsional load were compared for C+ file (CP, Dentsply Maillefer), M access K-file (MA, Dentsply Maillefer), Mani K-file (MN, Mani), and NiTiFlex K-file (NT, Dentsply Maillefer). The files of ISO size #15 and a shaft length of 25 mm were selected. For measuring buckling resistance (n = 10), the files were loaded in the axial direction of the shaft, and the maximum load was measured during the files' deflection. The files (n = 10) were fixed at 3 mm from the tip and then bent $45^{\circ}$ with respect to their long axis, while the bending force was recorded by a load cell. For measuring the torsional properties, the files (n = 10) were also fixed at 3 mm, and clockwise rotations (2 rpm) were applied to the files in a straight state. The torsional load and the distortion angle were recorded until the files succumbed to the torque. Results: The CP was shown to require the highest load to buckle and bend the files, and the NT showed the least. While MA and MN showed similar buckling resistances, MN showed higher bending stiffness than MA. The NT had the lowest bending stiffness and ultimate torsional strength (p < 0.05). Conclusions: The tested instruments showed different mechanical properties depending on the evaluated parameters. CP and NT files were revealed to be the stiffest and the most flexible instruments, respectively.