• Title/Summary/Keyword: Nickel (Ni)

Search Result 1,524, Processing Time 0.033 seconds

A prospective clinical trial to compare the performance of four initial orthodontic archwires (교정치료 초기에 사용되는 4가지 호선의 초기 치료효과를 비교하기 위한 전향적 임상 실험 연구)

  • Quintao, Catia C. A.;Jones, Malcoim L.;Menezes, Luciane M.;Koo, Daniel;Elias, Carlos N.
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.381-387
    • /
    • 2005
  • The aim of this study was to compare the clinical performance of 4 types of orthodontic wires, indicated for initial tooth alignment: stainless steel, multistranded steel, superelastic and thermoactivated nickel-titanium. A prospective randomized clinical trial was conducted on a sample of 45 patients, at the Dental School of the State University of Rio do Janeiro, Brazil. Fixed appliances were fitted and study casts were obtained from each patient. Randomly, the wires were allocated as follows: 26 dental arches for superelastic NiTi wires, 22 for stainless steel, 22 for multistranded and 20 for thermoactivated archwires. After 8 weeks, the archwires were removed and impressions for study casts were taken again. Using a 3D digitization technique of defined anatomical points on the study cast crowns, a Dental Irregularity Index (DII) was created for each study cast. The difference between DII before and after the archwire insertion expressed the aligning effect of the wires. ANOVA tests were employed to evaluate the anatomical point approximation (positive DII) and separation (negative DII), for each area of the dental arches: upper and lower whole arch and anterior arch. Results showed no significant difference between the different archwires.

THE EFFECT OF NITI ROTARY INSTRUMENTATION ON THE CONFIGURATION OF APICAL ROOT CANAL (NiTi Rotary Instruments에 의한 근관형성이 치근단부 근관형태에 미치는 영향)

  • Oh, Hyun-Jung;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.244-253
    • /
    • 1997
  • During preparation of narrow curved canals, procedural accidents such as, ledge, zipping, and transportation are frequently encountered and may lead to failure of endodontic therapy. To reduce these procedural errors and efficiently manage curved canals, various modifications in instrumentation technique and the design and flexibility of instruments have been advocated. This study compared the maintenance of the original canal curvature, cross sectional canal shape, and preparation time during instrumentation with stainless steel hand (K-Flexo) file, and nickel-titanium rotary files (Profile and Lightspeed). Thirty resin blocks with simulated curved canals of 20~25 degrees were used and divided into three groups of 10 each. In group 1, canals were instrumented using a quarter turn/pull technique with K-Flexofiles. Group 2 canals were prepared with rotary NiTi Profiles. Group 3 was prepared with rotary NiTi Lightspeed instrument. Before and after instrumentation, all canals were scanned using stereo microcope, FlexCam camera, and Photoshop 3.0 computer program. The results were as follows : 1. All groups showed some loss of canal curvature after instrumentation. Average loss of canal curvature was 8.6 degrees for K-Flexofile, 7.7 degrees for Profile, and 5.8 degrees for Lightspeed. Lightspeed exhibited significantly less curvature loss than K-Flexofile (p<0.05). 2. At the apical 1-mm level, Profile produced significantly rounder canals than Lightspeed (p<0.05). At the 3-mm level, Profile and Lightspeed exhibited significantly rounder canals than K-Flexofile (p<0.05). 3. Preparation with Lightspeed was significantly faster than Profile and K-Flexofile, and Profile was faster than K-Flexofile (p<0.05). 4. There was no significant difference in incidence of zipping between the hand K-Flexofile and rotary NiTi (Profile and Lightspeed) instruments. Most of apical canals were slightly widened near the apical foramen. As a results of this study, rotary NiTi instruments are superior to the K-Flexofile in regard to the maintenance of original canal curvature, cross-sectional shape and preparation time. But more investigations and studies should be needed to evaluate the ideal canal instrumentation.

  • PDF

A Study of pH, Duty Cycle, Agitation on the Property of Co-deposited TiO2 and Thermal Stability in the Electrodeposited Ni-TiO2 Composite (pH, duty cycle, 교반, 첨가제가 Ni-TiO2 전기도금 복합체의 TiO2 공석특성과 열적안정성에 미치는 영향 연구)

  • Kim, Myong-Jin;Kim, Joung-Soo;Kim, Dong-Jin;Kim, Hong-Pyo;Hwang, Seong-Sik
    • Journal of Surface Science and Engineering
    • /
    • v.45 no.3
    • /
    • pp.97-105
    • /
    • 2012
  • The effects of pH, types of applied current, agitation method and time, additive on the amount of co-deposited $TiO_2$ particles in the matrix were investigated. The deposition rates increased with increasing pH values, while the volume fraction of $TiO_2$ particles and the size of agglomerated $TiO_2$ particles in the composite decreased. The volume fraction of $TiO_2$ particles in the composite decreased when pulsed current of 50% duty cycle was used. And the size of agglomerated $TiO_2$ particles in the nickel matrix of pulsed current was smaller than that of DC current specimen. The volume fraction of $TiO_2$ particles in the matrix decreased with longer time by air agitation, but in case of using magnetic bar, volume fraction in the same range of time was relatively constant. The volume fraction of the electrodeposited Ni-$TiO_2$ composite in the solution containing 0.01 M Dimethylamine borane (DMAB) increased slightly with increasing agitation time regardless of agitation methods. Thermal stability of the electrodeposited Ni-$TiO_2$ composite increased with lower pH at the temperature range of $200{\sim}800^{\circ}C$, and the results showed that the amount of co-deposited $TiO_2$ relies more on the deposition rate than zetapotential of $TiO_2$ particles.

Preparation of Matte with Pyrite and Chalcopyrite as sulfur source and Leaching behaviour (황(黃) 원료(原料)로서 pyrite와 chalcopyrite를 사용(使用)한 matte 상(相)의 제조(製造) 및 침출특성(浸出特性))

  • Park, Kyung-Ho;Nam, Chul-Woo;Chang, Jong-Sin;Ahan, Sung-Chen;Kim, Hong-In
    • Resources Recycling
    • /
    • v.17 no.1
    • /
    • pp.51-58
    • /
    • 2008
  • Artificial mattes were prepared with adding pyrite or chalcopyrite as sulfur sources with Cu-Ni-Co-Fe alloy. The major phases identified by X-ray diffraction pattern were $(FeSi)_9S_8$, $CuFeS_2$, FeS, $Co_4S_3$, $Ni_3S_2$ and $Cu_2S$ for both mattes, and the matte prepared by adding chalcopyrite showed the higher peak of $Cu_2S$ due to high content of copper. Under optimum conditions, more than 95% copper, 90% nickel and 90% cobalt were extracted into leaching solution and sulfur concentration in the mattes did not much affect the leaching efficiency of the metals. The increase of the amount of pyrite or chalcopyrite added decreased pH in leaching solution and increased the concentration of iron ion dissolved in the leaching solution and the amount of residue.

Fabrication and Electrical Property Analysis of [(Ni0.3Mn0.7)1-xCux]3O4 Thin Films for Microbolometer Applications (마이크로볼로미터용 [(Ni0.3Mn0.7)1-xCux]3O4 박막의 제작 및 전기적 특성 분석)

  • Choi, Yong Ho;Jeong, Young Hun;Yun, Ji Sun;Paik, Jong Hoo;Hong, Youn Woo;Cho, Jeong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.41-46
    • /
    • 2019
  • In order to develop novel thermal imaging materials for microbolometer applications, $[(Ni_{0.3}Mn_{0.7})_{1-x}Cu_x]_3O_4$ ($0.18{\leq}x{\leq}0.26$) thin films were fabricated using metal-organic decomposition. Effects of Cu content on the electrical properties of the annealed films were investigated. Spinel thin films with a thickness of approximately 100 nm were obtained from the $[(Ni_{0.3}Mn_{0.7})_{1-x}Cu_x]_3O_4$ films annealed at $380^{\circ}C$ for five hours. The resistivity (${\rho}$) of the annealed films was analyzed with respect to the small polaron hopping model. Based on the $Mn^{3+}/Mn^{4+}$ ratio values obtained through x-ray photoelectron spectroscopy analysis, the hopping mechanism between $Mn^{3+}$ and $Mn^{4+}$ cations discussed in the proposed study. The effects of $Cu^+$ and $Cu^{2+}$ cations on the hopping mechanism is also discussed. Obtained results indicate that $[(Ni_{0.3}Mn_{0.7})_{1-x}Cu_x]_3O_4$ thin films with low temperature annealing and superior electrical properties (${\rho}{\leq}54.83{\Omega}{\cdot}cm$, temperature coefficient of resistance > -2.62%/K) can be effectively employed in applications involving complementary metal-oxide semiconductor (CMOS) integrated microbolometer devices.

Structural analysis of Precipitates in a Nickel based Cast Single Crystal of CMSX 6 (니켈계 초합금 CMSX 6 단결정 주조조직의 석출물구조 분석)

  • An, Seong-Uk;Larionov, V.;Grafas, I.;Kim, Su-Cheol;Im, Ok-Dong;Kim, Seung-Ho;Jin, Yeong-Hun;Choe, Jong-Su;Lee, Jae-Hun;Lee, Sang-Jun;Seo, Dong-Lee;Lee, Tae-Hun;Heo, Mu-Yeong
    • Korean Journal of Materials Research
    • /
    • v.8 no.12
    • /
    • pp.1165-1169
    • /
    • 1998
  • A single crystal cast blade was manufactured by CMSX 6, one of the first generarion nickel based single crystal superalloys by the selector method in a vacuum furnace. The single crystal has been grown with cooling rate of 2.5 mm/min, after pouring the molten alloy of 163$0^{\circ}C$ to the mold heated to 150$0^{\circ}C$. The cast structure could be classified into matrix (dendrite) and eutectic regions in ${\gamma}$'shape and size. The eutectic region showed higher Ti content. As the additional results of ${\gamma}$'precipitates by EPMA and CBED analysis the ${\gamma}$'size was less than 0.5~0.7$\mu\textrm{m}$, showing the chemical composition close to Ni$_3$Al of Ll$_2$ lattice structure. But ${\gamma}$'size has increased to bigger than 1.0$\mu\textrm{m}$, being near to eutectic region, changing its shape to bar or huge block types. These showed the chemical structure near to Ni$_3$Ti of D $O_{24}$ lattice structure. Therefore, ${\gamma}$'morphology of dendrite and eutectic regions depends absolutely on its chemical composition and lattice structure.

  • PDF

Establishment and application of standard-RSF for trace inorganic matter mass analysis using GD-MS (GD-MS 분석 장비를 활용한 극미량 무기물 질량 분석을 위한 표준RSF 구축 및 응용)

  • Jang, MinKyung;Yang, JaeYeol;Lee, JongHyeon;Yoon, JaeSik
    • Analytical Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.240-246
    • /
    • 2018
  • The present study analyzed standard samples of three types of aluminum matrix certified reference materials (CRM) using GD-MS. Calibration curves were constructed for 13 elements (Mg, Si, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Sn, and Pb), with the slope representing the relative sensitivity factor (RSF). The x- and y-axes of the calibration curve represented ion beam ratio (IBR) and the authenticated value of the standard sample, respectively. In order to evaluate precision and linearity of the calibration curve, RSD and the coefficient of determination were calculated. Curve RSD for every element reflected high precision (within 10 %). For most elements, the coefficient of determination was ${\geq}0.99$, indicating excellent linearity. However, vanadium, nickel, and gallium curves exhibited relatively low linearity (0.90~0.95), likely due to their narrow concentration ranges. Standard RSF was calculated using the slope of the curve generated for three types of CRM. Despite vanadium, nickel, and gallium exhibiting low coefficients of determination, their standard RSF resembled that of the three types of CRM. Therefore, the RSF method may be used for element quantitation. Standard iron matrix samples were analyzed to verify the applicability of the aluminum matrix standard RSF, as well as to calculate the RSD-estimated error of the measured value relative to the actual standard value. Six elements (Al, Si, V, Cr, Mn, and Ni) exhibited an RSD of approximately 30 %, while the RSD of Cu was 77 %. In general, Cu isotopes are subject to interference: $^{63}Cu$ to $^{54}Fe^{2+}-^{36}Ar$ and $^{65}Cu$ to $^{56}Fe-Al^{3+}$ interference. Thus, the influence of these impurities may have contributed to the high RSD value observed for Cu. To reliably identify copper, the resolution should be set at ${\geq}8000$. However, high resolutions are inappropriate for analyzing trace elements, as it lowers ion permeability. In conclusion, quantitation of even relatively low amounts of six elements (Al, Si, V, Cr, Mn, and Ni) is possible using this method.

Estimation of Mechanical Properties for Particle Dispersed Composites (입자 분산 복합재료의 기계적 성질 추정)

  • Tak Jin Moon;Dae Soon Im
    • Journal of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.414-420
    • /
    • 1982
  • The mechanical properties of nickel particle polyethylene composites were estimated by using a finite element method. Two steps were carried out in this analysis; the first step was to consider an unit model composed of spherical cell in the center of the matrix and the second step was to consider a total model composed of unit model. Two phase and three phase models were used, since another third phase were observed between matrix and nickel particle. Finite element method permits the calculation of the stress and displacement, assuming the arbitrary loads. Elastic modulus, Poisson's ratio and stress distribution of composites were obtained from this output. Comparison of the calculation by finite element method and the experimental results for Ni-filled polyethylene showed good agreement in tensile properties.

  • PDF

En-masse retraction with a preformed nickel-titanium and stainless steel archwire assembly and temporary skeletal anchorage devices without posterior bonding

  • Jee, Jeong-Hyun;Ahn, Hyo-Won;Seo, Kyung-Won;Kim, Seong-Hun;Kook, Yoon-Ah;Chung, Kyu-Rhim;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.44 no.5
    • /
    • pp.236-245
    • /
    • 2014
  • Objective: To evaluate the therapeutic effects of a preformed assembly of nickel-titanium (NiTi) and stainless steel (SS) archwires (preformed C-wire) combined with temporary skeletal anchorage devices (TSADs) as the sole source of anchorage and to compare these effects with those of a SS version of C-wire (conventional C-wire) for en-masse retraction. Methods: Thirty-one adult female patients with skeletal Class I or II dentoalveolar protrusion, mild-to-moderate anterior crowding (3.0-6.0 mm), and stable Class I posterior occlusion were divided into conventional (n = 15) and preformed (n = 16) C-wire groups. All subjects underwent first premolar extractions and en-masse retraction with preadjusted edgewise anterior brackets, the assigned C-wire, and maxillary C-tubes or C-implants; bonded mesh-tube appliances were used in the mandibular dentition. Differences in pretreatment and post-retraction measurements of skeletal, dental, and soft-tissue cephalometric variables were statistically analyzed. Results: Both groups showed full retraction of the maxillary anterior teeth by controlled tipping and space closure without altered posterior occlusion. However, the preformed C-wire group had a shorter retraction period (by 3.2 months). Furthermore, the maxillary molars in this group showed no significant mesialization, mesial tipping, or extrusion; some mesialization and mesial tipping occurred in the conventional C-wire group. Conclusions: Preformed C-wires combined with maxillary TSADs enable simultaneous leveling and space closure from the beginning of the treatment without maxillary posterior bonding. This allows for faster treatment of dentoalveolar protrusion without unwanted side effects, when compared with conventional C-wire, evidencing its clinical expediency.

Analyses of Creep Properties of Ni-base Superalloy Powders as Cooling Rate after Solid Solution Heat Treatment (니켈기 초내열합금 분말의 고용화 열처리 후 냉각속도에 따른 크리프특성 분석)

  • Jun, Chan;Lee, Youngseon;Bae, Byeong Beom;Kim, Hong-Kyu;Hong, Seong Suk;Kim, Donghoon;Yun, Jondo;Yoon, Eun Yoo
    • Journal of Powder Materials
    • /
    • v.23 no.3
    • /
    • pp.247-253
    • /
    • 2016
  • In this study, solid solution heat treatment of consolidated nickel-based superalloy powders is carried out by hot isotactic pressing. The effects of the cooling rate of salt quenching, and air cooling on the microstructures and the mechanical properties of the specimens are analyzed. The specimen that is air cooled shows the formation of serrated grain boundaries due to their obstruction by the carbide particles. Moreover, the specimen that is salt quenched shows higher strength than the one that is air cooled due to the presence of fine and close-packed tertiary gamma prime phase. The tensile elongation at high temperatures improves due to the presence of grain boundary serrations in the specimen that is air cooled. On the contrary, the specimen that is salt quenched and consists of unserrated grain boundaries shows better creep properties than the air cooled specimen with the serrated grain boundaries, due to the negative creep phenomenon.