• Title/Summary/Keyword: Ni-Zn alloy

Search Result 57, Processing Time 0.021 seconds

Local Structure Study of Ni in Ni-Zn Alloy Coating on Steel by X-ray Absorption Spectroscopy (X선 흡수 분광법을 이용한 Ni-Zn 도금 강판에서의 Ni의 국부 구조에 관한 연구)

  • Lee, Do-Hyung
    • Analytical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.202-205
    • /
    • 1998
  • X-ray absorption fine structure spectroscopic studies at the Ni K-edge have been performed for the Ni-Zn alloy coating layer on steel. The Ni-Zn interatomic distances and Debye-Waller factors were determined by fitting the experimental data with the theoretical spectra in the temperature range of 80 to 300K. The average Ni-Zn interatomic distance was found to be $2.557{\AA}$ and the variation of the Ni-Zn interatomic distance with temperature in this range was insignificant. From the comparison of the Ni-Zn interatomic distance with the nearest neighbor distance of pure Zn lattice it has been suggested that there is an apparent contraction around Ni atom.

  • PDF

Frictional characteristics of electro Zn-Ni alloy coated steel sheets (Zn-Ni계 합금도금강판의 마찰특성에 관한 연구)

  • 김영석;박기철;조재억
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.1807-1818
    • /
    • 1991
  • The frictional characteristic of Zn-Ni electrogalvanized steel sheet was investigated by experimental procedures. To clarify the effect of surface property on the frictional characteristic of Zn-Ni coated steel sheet, Micro-hardness test, SEM analysis and X-ray diffraction analysis were carried out. Coefficients of friction for various stamping lubricant and Ni content in coated layer were measured by a draw bead friction test. The results show that frictional characteristic is very sensitive to Ni content of coated layer and depends on stamping lubricant. For Ni content less than about 11%, selection of proper lubricant is necessary to obtain low coefficient of friction in Zn-Ni coated steel sheet such as in case of cold rolled steel sheet.

Effect of current density, temperature and electrolyte concentration on Composition of Zn-Ni Electrodeposits (Zn-Ni도금의 합금화에 미치는 전류밀도, 온도와 전해액농도의 영향)

  • Kang, Soo Young
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.307-312
    • /
    • 2017
  • In the industry, galvanizing using the principle of sacrificial anode is used Zn-Ni alloy plating was developed as one of the measures to increase the corrosion resistance rather than pure zinc plating. The alloy plating layer has a corrosion resistance of 4-5 times that of the pure zinc plating layer, so that it is applied to automotive parts requiring high corrosion resistance even though the plating cost is high. The amount of Zn-Ni alloy plating solution is a sulfuric acid bath, a chlorinated bath, an alkali bath, and an ammonia bath. Here, the influence of the electrolytic conditions on the composition of the alloy plating in the chloride bath was investigated. The results are explained by the cathode overvoltage and the diffusion coefficient. In general, as the overvoltage of the cathode increases, the concentration polarization becomes more important than the activation polarization. The concentration polarization is determined by element diffusion in the diffusion layer. That is, as the overvoltage of the cathode increases, the Zn content having a large diffusion coefficient increases.

A Study on Corrosion according to Distance between Amalgam and Dissimilar Metals (아말감과 이종(異種)금속의 거리에 따른 부식에 대한 고찰)

  • Kim, Ju-won;Jeong, Eun-gyeong
    • Journal of dental hygiene science
    • /
    • v.4 no.3
    • /
    • pp.103-109
    • /
    • 2004
  • The present study prepared 72 test samples - 24 made of amalgam alloy, 24 of Verabond (Ni-Cr alloy) for crown and 24 of Talladium $^{TM}alloy$ for denture - according to the manufacturers' manuals and general method in consideration of the width of the mesial-distal dental crown of the lower $1^{st}$ molar and MOD cavity in clinics, put them in a 200 ml beaker containing 80 ml of artificial saliva, and measured their galvanic corrosion at distances of 0 mm, 7 mm and 40 mm after 7 days. Isolated metals in the electrolyte such as Cu, Ag, Ni, Cr, Sn, Zn and Hg were quantitatively analyzed with Inductively Coupled Plasma - Atomic Emission Spectrometer (ICP-AES, JY-50P, VG Elemental Co. France), and from the results were drawn conclusions as follows. First, Cu, Sn, Ag, Hg and Zn were highly advantageous when amalgam contacted gold alloy compared to Ni-Cr alloy for crown and Talladium alloy for denture. In addition, although gold alloy was finest in terms of oral tissue and biocompatibility, it was most disadvantageous when it was with amalgam. Second, when amalgam contacted gold alloy, heavy metals such as Ni and Cr were not isolated at all because gold alloy did not contain such elements but Sn was isolated as much as $227.1{\pm}18.0035{\mu}g/cm^2$ although it was not included in the composition either. Hg was also isolated. These elements are assumed to have been isolated from amalgam itself. Third, when amalgam alloy was apart from gold alloy 0 mm, 7 mm and 40 mm, Cu and Ag showed significance but Hg did not. This suggests that gold alloy must not be used together with amalgam, and must not be used between dissimilar prostheses regardless of distance. Fourth, when amalgam alloy contacted Ni-Cr alloy for crown, Ag was not isolated from the amalgam, but Zn, Ni, Sn, Hg and Cu were isolated in order of quantity. Significance was observed according to distance - 0 mm, 7 mm and 40 mm. Hg was not isolated but heavy metals Ni and Cr were isolated. If amalgam alloy was in the opposite arch or it was apart from Ni-Cr alloy for crown, the isolation Hg was less than that when amalgam alloy contacted Ni-Cr alloy for crown. Fifth, when amalgam alloy contacted Talladium alloy for denture, significance was observed at distances of 0mm, 7 mm and 40 mm. Hg was not isolated but heavy metals Ni and Cr were isolated. If amalgam alloy was in the opposite arch or it was apart from Talladium alloy for denture, the isolation Hg was less than that when amalgam alloy contacted Talladium alloy for denture. Sixth, according to the result of ICPES test on Cu, Sn, Ag, Hg, Zn, Ni and Cr of amalgam alloy, gold ally, Verabond and Talladium alloy when these alloys contacted artificial saliva, significance was observed in Cu and Hg. Seventh, when amalgam alloy contracted two non-precious metals Ni-Cr alloy for crown and Talladium alloy for denture in artificial saliva, significance was observed in the isolated by-products of Hg, Ni and Cr according to distance.

  • PDF

Microstructure of Zn-Ni Alloy Electrodeposir (아연-니켈합금전착층의 조직특성)

  • 예길촌;최성렬;신현준;안덕수
    • Journal of the Korean institute of surface engineering
    • /
    • v.21 no.1
    • /
    • pp.10-18
    • /
    • 1988
  • The variation of Composition and the microstructure of Zn-Ni alloy electrodespposits were investigated to the electrolysis conditions chloride bath. The codeposition mechanism is of the equilibrium type in the electrolysis condition of the high temperature(6$0^{\circ}C$)and high flow rate (1.2-3.0m/sec). The(411, 330) perferred orienation was mainly developed in the Zn-Ni electrodeposir with ${\gamma}$-phase structure, while the(422.600) orientation was closely related to the commposition and the structure of the alloy electrodeposit.

  • PDF

Corrosion Analysis of Ni alloy according to the type of molten metal (용융아연도금욕에 적용되는 용탕에 따른 Ni합금의 부식성 분석)

  • Baek, Min-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.459-463
    • /
    • 2017
  • Hot dip galvanizing in the steel plant is one of the most widely used methods for preventing the corrosion of steel materials including structures, steel sheets, and materials for industrial facilities. While hot dip galvanizing has the advantage of stability and economic feasibility, it has difficulty in repairing equipment and maintaining the facilities due to high-temperature oxidation caused by Zn Fume where molten zinc used in the open spaces. Currently, SM45C (carbon steel plate for mechanical structure, KS standard) is used for the equipment. If a part of the equipment is resistant to high temperature and Zn fume, it is expected to improve equipment life and performance. In this study, the manufactured Ni alloy was tested for its corrosion resistance against Zn fume when it was used in the hot dip galvanizing equipment in the steel plant. Two kinds of materials currently used in the equipment, new Ni alloy and Inconel(typical corrosion-resistant Ni alloy), were selected as the reference groups. Two kinds of molten metal were used to confirm the corrosion of each alloy according to the molten metal. Zn fume was generated by bubbling Ar gas from molten Zn in a furnace($500{\sim}700^{\circ}C$) and the samples were analyzed after 30 days. After 30 days, the specimens were taken out, the oxide layer on the surface was confirmed with an optical microscope and SEM, and the corrosion was confirmed using a potentiodynamic polarization test. Corrosion depends on the type of molten metal.

MICROSTRUCTURE AND ELECTROCHEMICAL CHARACTERISTICS OF ELECTRODEPOSITED Zn-Ni ALLOY COATINGS

  • Short, N.R.;Hui, Wen-Hua;Dennis, J.K.
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.281-288
    • /
    • 1999
  • Electrodeposited Zn-Ni alloy coatings are of particular interest for improving the corrosion resistance of steel in a number of enviornments. Of particular interest is the relationship between composition, structure and corrosion rate. This paper firstly reviews the literature regarding composition-structure relationships of Zn-Ni electrodeposits and compares them with the equilibrium phase diagram. Secondly, research was carried out on a wide range of coatings which were produced in the laboratory and their structure and corrosion rates determined. It was found that unambiguous identification of phases from XRD data can be difficult. Maximum corrosion resistance of deposits is obtained at 12-13% Ni, with a $\gamma$ phase structure and predomination of (600) and (411) reflections. Compatibility is important with regard to chromate conversion coatings.

  • PDF

Corrosion Resistance of the Roll Formed Steel Bolts with the Various Types of Coating Methods (2) (다양한 코팅 방법에 따른 전조한 강 볼트의 내부식성 (2))

  • Mamatov, S.;Hamrakulov, B.;Son, Y.H.;Kim, I.
    • Transactions of Materials Processing
    • /
    • v.28 no.2
    • /
    • pp.77-82
    • /
    • 2019
  • Corrosion occurs well on surface of roll formed and Zn alloy subsequently electro-deposited on steel bolt under wet condition. In this study, variations in corrosion resistance were investigated through the measurement of polarization curves on steel bolts which were roll formed and subsequently coated with various types of coating methods. According to the measured polarization curve, Ni-P electroless deposits on roll formed steel increased the resistance to corrosion. The corrosion resistance of Zn alloy powder coated steel bolt was found to be better than that of Zn-Ni electro-deposited sample.