• 제목/요약/키워드: Newly house

검색결과 145건 처리시간 0.023초

신축 아파트의 TVOC 농도 및 거주자의 새집증후군 반응 (TVOC Concentrations and Residents' Responses on Sick House Syndrome of Newly-Built Apartments)

  • 최윤정;안혜정;강미라;이혜민
    • 한국실내디자인학회논문집
    • /
    • 제15권4호
    • /
    • pp.129-137
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations and personal factors to reduce the Sick House Syndrome for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air Quality Management for multi-use facilities. The Questionnaire surveys of residents' subjective responses on the Sick House Syndrome were carried out in 2nd measurement of each house. Respondents consisted of 20 residents living in the measured houses. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among all measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. There turned out to be no apparent relations between the TVOC concentrations and the residents' individual responses of Sick House Syndrome. The responses were serious in those who stayed in their new houses for a long period or had disease like allergy. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

신축 아파트 거주자의 새집증후군 반응 및 의식 조사 - 청주시를 중심으로 - (Residents' Responses and Consciousness on Sick House Syndrome of Newly Built Apartments - Focusing on Cheongju -)

  • 최윤정
    • 대한가정학회지
    • /
    • 제44권3호
    • /
    • pp.103-113
    • /
    • 2006
  • The purpose of this study was to determine the present condition of sick house syndrome of newly built apartments a mid-sized city. The questionnaire survey was carried out from $19^{th}\;to\;22^{nd}$ of May 2004, with respondents consisting of 160 households living in two apartment complexes of Cheongju. Their residency periods after moving in were within $six{\sim}ten$ months. From the survey results of the respondents, sick house syndrome items revealed high percentages with the highest value of 49.3%. The respondents answered that they knew relatively well about sick house syndrome but they had no knowledge about 'bake-out'. The response percentages of sick house syndrome items in E complex, consisting of $106m^2$ (32 pyeong) size units, were significantly higher than those in A complex, consisting of $76m^2$ (23 pyeong) size units. This result suggests that the pollution levels emitted from interior materials in larger sized apartment units are higher than those in small sized units. The response percentages of sick house syndrome items in houses with fulfilled ventilation which had been ventilated before or after moving in were lower than in houses not ventilated.

현장실험을 통한 공동주택의 실내공기환경 평가 (A Evaluation Study on Indoor Air Quality of the Apartment House through Field Measurement)

  • 박용승;배상환;유복희;홍천화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.83-87
    • /
    • 2003
  • In recent days, IAQ(Indoor Air Quality) is regarded as one of the most important environmental factors as well as thermal and acoustic comfort. Various architectural materials are applied and air-tightness of the building is more strengthening to save energy consumption. This is why the air quality of the newly built houses became worse. In this study, contaminants(CO, CO$_2$, Radon, TVOCs, HCHO) density was measured in a newly built house and evaluation was carried out by ASHRAE and EPA Standards. As a result, CO, CO$_2$, TSP and Radon density of the newly built house was in a range of ASHRAE and EPA Standards, but it turned out TVOCs and HCHO density exceeds almost 3${\sim}$5 times in comparison with that of ASHRAE and EPA Standards.

  • PDF

환기량 변화에 따른 신축공동주택의 실내공기질 개선효과 검토 (The Effect on Indoor Air Quality Improvement by Ventilation Rate in Newly Built Apartment)

  • 최석용;김상희;이정재
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.649-655
    • /
    • 2006
  • The recent indoor air quality problem in a newly-built apartment house is resulted from the improvement of airtightness performance and the use of the building material contained harmful chemical substances. As a result, these cause indoor air quality gradually to become worse and the harmful effect on occupant health called Sick House Syndrome. The most effective solution to improve the indoor air quality is to encourage the use of green building material. However, if the house is built with general building material, ventilation with outdoor air is alternative to dilute the pollutant concentration. The purpose of this re-search is to find optimum ventilation time in a newly-built apartment house at which the ventilatoris installed. It is found that the HCHO and toluene concentrations are remarkably decreased with the elapse of ventilation time and the concentration reduction rate is increased with increment of air change rate after one hour after operating the ventilator.

신축 아파트의 총휘발성유기화합물 농도와 관련요인 분석 (Analysis on TVOC Concentrations and Influence Factors of Newly-Built Apartments)

  • 최윤정;강미라;이혜민;안혜정
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.268-271
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air auality Management for multi-use facilities. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among ail measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

  • PDF

신축 공동주택의 VOCs 실태조사 (A study on measurement of VOCs in newly house)

  • 유복희;윤정숙
    • 한국주거학회논문집
    • /
    • 제13권5호
    • /
    • pp.71-76
    • /
    • 2002
  • Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the air pollutant indoor. In addition, Volatile Organic Compounds(VOCs) has been paid attention to as one of the main reason that causes air pollutant indoor, and the exposure of VOCs indoor is recognizes as an important factor which have an effect on the health of resident. In this study, measuring of VOCs in newly houses, and the results are as follows; 1)TVOC(Total Volatile Organic Compounds) indoor is detected high concentration(11314$\mu\textrm{g}$/㎤). 2)There are detected acetaldehyde, methylenechloride, benzene, trichloroethylene and styrene that have to take precaution against human carcinogenicity

실측을 통한 신축공동주택의 주요 VOCs 물질 농도에 관한 연구 (A Study on Concentration of Volatile Organic Compounds in Newly-Apartment House by Measurement)

  • 김창남;김용경;이성진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1220-1224
    • /
    • 2008
  • Because of the high airtightness and insulation of the building, indoor environment has been largely polluted resulted from insufficient ventilation and occurrence of new air pollutant. These factors have made worse indoor air quality and caused symptoms of the SHS(Sick House Syndrome), MCS(Multi Chemical Sensitivity). The purpose of this study is to present the fundamental strategies for improving the Indoor Air Quality(IAQ) in newly-constructed apartment buildings. To investigate the concentration of indoor air pollutants such as Formaldehyde and VOCs, the field measurement were conducted.

  • PDF

에너지절약 주택과 일반 아파트에서의 실내 화학오염물질 농도 변화 특성 (The Characteristic of the Concentration Transition of Chemical Substances in Energy Saving House and Apartment House)

  • 유복희;박선효
    • 한국주거학회논문집
    • /
    • 제19권1호
    • /
    • pp.49-55
    • /
    • 2008
  • Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the indoor air pollutant. Volatile Organic Compounds $(VOC_s)$ and formaldehyde have been considered as one of the main reason that causes indoor air pollutant. This study is for introducing and designing thermal performance of super energy saving building by conducting $VOC_s$ and formaldehyde concentration in the 3Liter house. The results of the measurement for 10 months showed that $VOC_s$ and formaldehyde decreased until the guideline concentration. It took about 7 months, and it appeared right after new construction. However, their levels were showed higher concentration in comparison with the ordinary residential houses (apartment house). The main difference of between newly built 3Liter house and ordinary apartment is their air changes, which are 0.67/h for 3Liter house and 4.0/h for the apartment.

실내공기중의 휘발성유기화합물 농도변화에 관한 연구 (A Study on Concentration of Volatile Organic Compounds in the Apartment House)

  • 이윤규
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.129-136
    • /
    • 2004
  • Recently, indoor air pollution has been seriously apprehended, and became a striking issue, due to the airtightness of buildings or the misuse of building materials. Especially, SHS(Sick House Syndrome) and MCS(Multi Chemical Sensitivity) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. The emission rates of VOCs is sensitively affected by the indoor/outdoor condition, construction materials, construction method, and character of ventilation facilities. Therefore, in this study, by measuring the indoor air pollution substance of the existing apartment house, the problem over this tends to be grasped and it is going to secure an improvement methods.

신축공동주택에서의 실내공기 오염물질 방출 저감 프로세스에 관한 연구 (A Study on a Proper Reduction Process of Indoor Air Pollutants In Newly-Constructed Multi-Family Houses)

  • 유형규;박진철;이언구
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.468-476
    • /
    • 2005
  • The purpose of this study is to investigate actual air quality in newly-constructed multi-family houses and to improve Indoor Air Quality (IAQ). The field measurement was conducted in four different newly-constructed multi-family house complexes in Seoul and one existing multi-family house complex in Kyong-gi province. The result of the measurement shows that indoor concentrations of Formaldehyde and TVOC in newly-constructed multi-family houses are much higher than the foreign standards. To establish a proper process for reducing indoor air pollutants, various experiments have been conducted; application of natural materials, bake-out practice, closure of all openings without ventilation, and use of mechanical ventilation system. The result indicates that three practices (natural materials, bakeout, mechanical ventilation) can reduce the level of indoor air pollutants almost in half during the experiments. However, each practice has its limitation and is insufficient to satisfy IAQ standards. Therefore, the study proposes a proper reduction process of indoor air pollutants which combines four different practices in time sequence.