• Title/Summary/Keyword: Newly built

Search Result 468, Processing Time 0.032 seconds

Hazardous Organic Compounds Concentration of Newly Built School Classroom and Neurobehavioral Performance of Elementary School Children (신축학교 교실 실내공기 중 유해유기물질 농도와 초등학생의 신경행동기능에 관한 연구)

  • Kwaak, Hong-Taak;SaKong, Joon
    • Hwankyungkyoyuk
    • /
    • v.24 no.3
    • /
    • pp.18-25
    • /
    • 2011
  • This study was conducted to evaluate the effects of volatile organic compounds and formaldehyde of newly-built school classroom indoor air on the neurobehavioral functions of students. The elementary schools that were opened in September 2008(as of September 2008) was selected for newly-built school and the elementary school that were opened in March 2006 was selected for control group schools. The concentration of formaldehyde(HCHO), a hazardous organic compound that exists in the air of classrooms, exceeded the standard value of $108.2{\mu}g/m^3$ in newly-built schools while it was $60.8{\mu}g/m^3$ in control group schools, which is around 60% of the standard concentration. However, the concentration of the total volatile organic compounds(TVOCs) was $788.9{\mu}g/m^3$ and $756.1{\mu}g/m^3$ in newly-built schools and control group schools respectively, which are approximately two times higher than the standard concentration. In newly-built schools, the mean reaction time of additions and symbol digit, respectively 3,020ms and 2,398ms in pre-exposure were increased to 3,167ms and 2,514ms respectively in post-exposure. The difference of mean reaction time between pre and post exposure was 146.8 ms, or 4.6%, and 116.7ms, or 4.8%, respectively, showing statistically-significant increase of reaction time(p<0.05). On the contrary, the difference of reaction time of both tests were not statistically significant in the control group schools. These results showed that the neurobehavioral performance of newly-built schools students were affected by volatile organic compounds and formaldehyde of classroom indoor air.

  • PDF

A Study On Status of Remodeling in Newly Built Apartments and Its Improvements (신축 공동주택의 리모델링 실태와 개선방안에 관한 연구)

  • Kim, Jae-Yeob;Lee, Ji-Young;Kim, Dae-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.4 s.22
    • /
    • pp.103-108
    • /
    • 2006
  • Currently, due to remodeling of newly built apartment, national resource loss and personal economic loss are being occurred and construction wastes are making more environmental issues. This study aims to devise reduction in cost and economic loss coming from remodeling by selecting general house size of apartment, carrying out surveys and investigating current status of remodeling before and after moving into newly built apartments.

Analysis on Characteristics and Related Factors of Indoor Air Quality in Newly Built Wooden Houses (신축목조주택의 실내공기질 특성 및 관련요인 분석)

  • Choi, Yoon-Jung;Lee, Jae-Kyung;Cha, Ye-Rang
    • Journal of the Korean housing association
    • /
    • v.26 no.4
    • /
    • pp.23-32
    • /
    • 2015
  • The purpose of this research is to analyze characteristics and related factors of IAQ (Indoor Air Quality) in newly built wooden houses by measuring pre and post occupancy. The subjects were five wooden houses which were built with similar materials and completed from July to December 2013. Measuring factors were TVOC, HCHO, PM10, $CO_2$, CO, indoor temperature, and relative humidity. As the result of pre occupancy measuring, the houses that revealed the lowest TVOC concentration or HCHO concentration were satisfied with "the standard for newly built apartment houses". Therefore, IAQ by the wooden structures is considered to be in good condition. However, in cases of partial value exceeded the standard, the reason is analyzed to be the materials of molding, wrapping doors, built-in closet, or kitchen furniture, etc. rather than structure materials. Most PM10 concentration level showed slightly below "the standard for occupied multi-use facilities". Remaining of construction dust was considered to be the reason. As the result of post occupancy measuring, every value except of one subject's TVOC concentration was lower than pre occupancy, explaining the importance of natural ventilation.

A Study on Architectural Characteristics of the Newly Built Hanok in Seoul Since 2000 - Focused on the Kan Composition - (2000년 이후 서울의 신축한옥에서 보이는 건축적 특징 - 칸 구성을 중심으로 -)

  • Kim, SungHa;Jeon, BongHee
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.9
    • /
    • pp.109-117
    • /
    • 2019
  • Since 'Hanok Expanse Support' has been started in Seoul, its target was expanded from renovation to new construction and from 'Hanok District' to all area in Seoul. The newly built hanok with Hanok Expanse Support had to follow the standards about the form of the hanok and adapt to modern lifestyle. However, the newly built hanok were planned with 'kan' since it retained the traditional wooden structure. So their composition of kan were considered to be influenced by the standards of each district and modern lifestyle. Therefore the aim of this study is to understand the architectural characteristics of newly built hanok in Seoul since 2000 focusing on the kan composition. Because of the differences in site conditions and the district unit plan, newly built hanok in Hanok District have more limited changes than Other District. However, kan is composed variously in horizontal and vertical ways to make the most space according to site conditions and most of the newly built hanok have opened courtyard rather than closed courtyard layout. With kan composition in various directions and kan added under the eaves, kan is highlighted in form. On the other hand, the composition of kan as an interior spatial element has changed and weakened because the lifestyle has changed compared to the traditional hanok and the 20th century urban hanok. Also the regular kan composition of Mom-chae and Nalgae-chae has changed. And kan is divided regardless to the wooden structure. Also, with the added kan under the eaves the main kan is dismantled inside. This paper indicates that although there is an undeniable premise that the case is restricted to hanok received Hanok Expanse Support on the condition of following the standards of the form of hanok, it is a part of the transitional changes that hanok is experiencing.

A Study on the Field Evaluation about the Indoor Air Quality of Schools Newly Built in Changwon (창원지역 신축학교의 실내공기질 현장평가 연구)

  • Yoo, Jong-Hoon;Kang, Eun-Hye;Son, Young-Hwan;Ha, Suk-Yong;Choi, Jeong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1244-1249
    • /
    • 2006
  • Because students are spending more time in their classroom for learning and study, indoor air quality problems in school classrooms are very important. when the classroom is built for the first time, namely newly built school, the selection of inside finishing material is directly connected with indoor air quality problems especially with HCHO and TVOC. But until now, there is no plenty of study about this. Moreover, there are some concerns about the desks and chairs which are used in classroom will affect the air quality. but almost no study is being made at all Therefore, this study focuses on the field survey and analysis of classroom indoor air quality in newly built schools in Changwon. In this study filed surveys and analysis are conducted as follows. 1) The effect of the material difference in general classroom. 2) The effect of the material and loading ratio difference in special classroom. 3) The effect of the desks and chairs in general classroom.

  • PDF

A Study for the Indoor Air Concentration of VOCs and HCHO in Newly Built and Remodeled Classrooms (신개축 교사내 실내공기중 휘발성유기화합물과 폼알데히드의 농도 특성)

  • Park, Jeong Ho;Yang, Su Myoung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.222-228
    • /
    • 2013
  • Objectives: The indoor air quality of newly-built (NC) and remodeled (RC) school classrooms was assessed. The primary aim was to show correlations between volatile organic compounds (VOCs) and formaldehyde (HCHO) pollutant levels. Methods: This study investigated the indoor air concentrations of VOCs and HCHO at 26 sites of newly built and 68 sites of remodeled classrooms located in South Gyeongsang Province between 2010 and 2012. VOCs in the indoor air were determined by adsorbent tube (Tenax TA) and automatic thermal desorption coupled with GC-MS analysis. Target analytes were five VOCs: benzene, toluene, ethylbenzene, xylene, and styrene. HCHO was collected with a 2,4-DNPH cartridge and analyzed by HPLC. Conclusions: This study estimated that indoor VOCs and HCHO concentrations in the classrooms were mainly affected by interior building materials and classroom equipment. For proper indoor air quality in schools, classroom air should be improved through reduction of hazardous materials by adequate ventilation, selecting environmental friendly materials, etc.

Actual State of TVOC and HCHO Concentration in Newly Built or Remodeled Kindergarten (신축 및 리모델링 유치원의 휘발성유기화합물 농도 실태)

  • Choi, Yoon-Jung;Park, Eun-Bi;An, Ji-Sun
    • Korean Journal of Human Ecology
    • /
    • v.18 no.6
    • /
    • pp.1363-1374
    • /
    • 2009
  • The purpose of this study was to determine the actual state of the indoor air quality in newly built or remodeled kindergartens by TVOC and HCHO concentration and teachers' responses. The field measurements on the levels of TVOC and HCHO were carried out in six classrooms of newly built or remodeled kindergartens before their opening. The interviews with teachers of subject kindergartens were carried out at the end of the first semester. The contents of the interviews were teachers' subjective responses and symptoms of the kindergarten pupils on the Sick New-School Syndrome. The results are as follows; the mean value of TVOC concentration in the classrooms of kindergartens ranged from 0.10ppm to 0.42ppm, which can theoretically exert a harmful influence on residents. The mean value of HCHO concentration ranged from 0.00ppm to 0.03ppm, which does not exceed the standard. The TVOC concentrations of the more ventilated kindergartens were lower than the others. Also, the classrooms with high concentrations of TVOC showed negative responses or symptoms in teachers and kindergarten pupils.

Effects of Flush-out in the Reduction of Formaldehyde in Newly Built Residential Buildings (신축 공동주택에서 플러쉬아웃에 따른 폼알데하이드 농도 저감 효과에 관한 연구)

  • Park, Sang In;Kim, Joo Han;Park, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.116-122
    • /
    • 2018
  • The purpose of this study was to confirm the effects of flush-out in the reduction of formaldehyde concentration in newly built residential buildings. The field measurements were conducted on two complexes of multi-residential buildings which are located in the suburban area of Seoul. About eight samples of residential buildings were selected to measure the changes in formaldehyde concentrations after flush-out from the two apartment complexes. The concentration of formaldehyde was measured using DNPH cartridge and HPLC. From the results of the field measurements, it was established that indoor formaldehyde concentration decreases 27.6~54.2% in the samples after flush-out. The number of days that the flush-out were conducted was noted to have no significant influence on the reduction rate of formaldehyde concentration when the flush-out continued more than 7 days. The comparison with Bake-out showed that flush-out also can reduce formaldehyde in newly built buildings as same levels of it.

Analysis on TVOC Concentrations and Influence Factors of Newly-Built Apartments (신축 아파트의 총휘발성유기화합물 농도와 관련요인 분석)

  • Choi, Yoon-Jung;Kang, Mi-Ra;Lee, Hye-Min;An, Hye-Jung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.268-271
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air auality Management for multi-use facilities. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among ail measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

  • PDF

TVOC Concentrations and Residents' Responses on Sick House Syndrome of Newly-Built Apartments (신축 아파트의 TVOC 농도 및 거주자의 새집증후군 반응)

  • Choi Yoon-Jung;An Hye-Jung;Kang Mi-Ra;Lee Hye-Min
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.129-137
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations and personal factors to reduce the Sick House Syndrome for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air Quality Management for multi-use facilities. The Questionnaire surveys of residents' subjective responses on the Sick House Syndrome were carried out in 2nd measurement of each house. Respondents consisted of 20 residents living in the measured houses. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among all measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. There turned out to be no apparent relations between the TVOC concentrations and the residents' individual responses of Sick House Syndrome. The responses were serious in those who stayed in their new houses for a long period or had disease like allergy. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.