Journal of mucopolysaccharidosis and rare diseases
/
v.3
no.1
/
pp.9-13
/
2017
Tandem mass spectrometry and other new technologies for the multiplex and quantitative analysis of dried blood spots have emerged as powerful techniques for the early screening and assessment of newborns for lysosomal storage diseases (LSDs). Screening newborns for these diseases is important, since treatment options, including enzyme replacement therapy or hematopoietic transplantation, are available for some LSDs, such as infant-onset Pompe disease, Fabry disease, some types of mucopolysaccharidoses (MPSs), and Krabbe disease. For these diseases, early initiation of treatment, before symptoms worsen, often leads to better clinical outcomes. Several problems, however, are associated with newborn screening for LSDs, including the development of accurate test methods to reduce low false-positive rates and treatment guidelines for late-onset or mild disease variants, the high costs associated with multiplex assays, and ethical issues. In this review, we discuss the history, current status, and ethical problems associated with the newborn screening for LSDs, including MPSs.
Journal of The Korean Society of Inherited Metabolic disease
/
v.16
no.2
/
pp.62-69
/
2016
Newborn screening of some urea cycle disorders has little benefits because of early severe symptoms before the result, low sensitivity (especially hypocitrullinemia) and poor prognosis. But in case of citrullinemia, citrin deficiency and argininosuccinic aciduria diagnosed as elevated citrulline, newborn screening is helpful for early diagnosis and treatment before the symptom. Distinction between the clinical forms of these diseases is based on clinical findings and biochemical results, however, they may not be clearcut. Treatment is different from each other, so exact diagnosis is essential. Here, the diagnostic algorithm for elevated citrulline after tandem mass screening has been proposed. Minimizing total process time from sampling to report of the results is important in Korea for diagnosis and treatment of these disorders.
Hearing loss in newborns is the most frequently occurring birth defect. If hearing impaired children are not identified and managed early, it is difficult for many of them to acquire the fundamental language, social and cognitive skills that provide the foundation for later schooling and success in society. All newborns, both high and low risk, should be screened for hearing loss in the birth hospital prior discharge (Universal Newborn Heaing Screening, UNHS). Objective physiologic measures must be used to detect newborns and very young infants with hearing loss. Recent technological developments have produced screening methods and both evoked otoacoustic emission (EOAE) and auditory brainstem response (ABR) have been successfully implemented for UNHS. Audiologic evaluation should be carried out before 3 months of age and infants with confirmed hearing loss should receive intervention before 6 months of age. All infants who pass newborn hearing screening but who have risk indicators for other auditory disorders and/or speech and language delay receive ongoing audiologic surveillance and monitoring for communication development. Infants with sensorineural hearing loss are managed with hearing aids and receive auditory and speech-language rehabilitation therapies. Cochlear implants can be an outstanding option for certain children aged 12 months and older with severe to profound hearing loss who show limited benefit from conventional amplifications.
Park, Sung Won;Yun, Byung Ho;Kim, Kyung Ah;Ko, Sun Young;Lee, Yeon Kyung;Shin, Son Moon;Hong, Sung Hwa
Clinical and Experimental Pediatrics
/
v.49
no.10
/
pp.1056-1060
/
2006
Purpose : As hearing ability affects language and cognitive development, early detection and intervention of congenital hearing defects is very important. We analyzed the result of newborn hearing screening using automated auditory brainstem response and estimated the incidence of congenital hearing defects in newborn infants in Korea. Methods : Hearing screening tests were done on 7,218 newborn infants who were delivered at Cheil General Hospital from July 1, 2004 to June 30, 2005. The first screening test was done on the second day of life with automated auditory brainstem response(AABR) using $ALGO{\bigcirc}^{(3)}$ Newborn hearing screener($Natus^{(R)}$ Medical Incorporated, San Carlos, USA) with 35 dB sound level. The newborn infants who did not pass the initial screening test took the second screening AABR test before discharge from the nursery. Infants who did not pass these screenings at the nursery were followed up at the Department of Otorhinolaryngology, Samsung Seoul Hospital. Results : Total 7,218 infants(83.3 percent of total 8,664 live births of the Cheil General Hospital) were screened in the nursery, and 55 of them failed to pass the newborn screening. Among 55 infants who were referred, six were lost during follow-up, and 14 were confirmed as hearing impaired. Six of them(42.8 percent) do not have any risk factors for hearing impairment. We can estimate that the incidence of hearing defects is about 1.9-2.8 per 1,000 live births. Conclusion : Automated auditory brainstem response is an effective tool to screen the hearing of newborn infants. Congenital hearing loss is more frequent than metabolic diseases on which screening tests are available in the newborn period. About 40 percent of infants who have hearing defects do not have any risk factors for hearing impairment. Therefore, universal newborn hearing screening must be recommended to all neonates.
Purpose : In recent years, many countries have adopted newborn screening programs that use tandem mass spectrometry (MS/MS) to screen and the number of diseases screened has also increased. We began screening for inherited metabolic disorders using MS/MS in April, 2001. Our goal was to determine the overall prevalence of metabolic disorders and to assess the effectiveness of newborn screening by MS/MS in Korea. Methods : From April, 2001 to December, 2007, we screened newborns and high risk groups using MS/MS. Acylcarnitines and amino acids were extracted and butylated and were introduced into the inlet of MS/MS. Confirmatory testing including a repeat newborn screening, and urine organic acid and plasma amino acid analysis were performed on a case-by-case basis. Results : The total number of screened subjects 284,933 which comprised 251,799 neonates and 33,134 high risk subjects. The recall rate was 0.4% (1158 tests) and true positive cases were 117 (0.04%). Confirmed metabolic disorders (newborn/high risk group) were as follows; 78 (25/53) amino acid disorders, 27 (16/11) organic acid disorders, and 12 (5/7) fatty acid oxidation disorders. The estimated prevalence of inherited metabolic diseases in newborns was 1:5,000 and that in the total group was 1:2,000. Conclusion : Newborn screening by MS/MS improved the detection of many inherited metabolic disorders. We therefore propose that all newborns be screened by a MS/MS national program and followed-up using a systemic organization strategy.
Journal of agricultural medicine and community health
/
v.43
no.3
/
pp.172-179
/
2018
Objectives: To review the status of newborn hearing screening (NHS) and to investigate the effect of the examiners on NHS tests to help the quality control of NHS at a general hospital in a city. Methods: The charts of newborns from January 2015 to March 2016 and from August 2016 to October 2017 were retrospectively reviewed. We compared the results of tests performed by several examiners(group 1) with those performed by one audiologist (group 2) using the same automated auditory brainstem response test. Results: The screening rate and referral rate were not significantly different between group 1 and group 2. The confirmatory test rate was higher in the group 2, but it was not significant. In group 1, the number of tests performed 3 or more times in one ear at one time was significantly higher. The number of tests performed in only one ear at one time was higher in group 2. The screening rate within one month after birth was 64.21%, referral rate was 7.32%, confirmatory test rate within 3 months after birth was 21.74%, and the prevalence of hearing loss was 1.46%. Conclusions: There was no significant difference of results depending on the examiners. In order to make proper screening test, it is necessary to periodically educate the examiner and to instruct the examiner by the supervisor doctors.
Journal of The Korean Society of Inherited Metabolic disease
/
v.14
no.1
/
pp.1-9
/
2014
Many inborn errors of metabolism can be completely cured with early detection and early treatment. This is why neonatal screening on inborn errors of metabolism is implemented worldwide. In 1991, the Ministry of Health & Social affairs adopted a nationwide service program for neonatal screening of phenylketonuria, galactosemia, maple syrup urine disease, homocystinuria, histidinemia and congenital hypothyroidism for newborns delivered from low class pregnant women registered in health centers. Government decreased the test items from six to two, PKU and congenital hypothyroidism to increase test numbers with same budget from 1995. 78 laboratories wanted to participate for neonatal screening test in 1999. Government decided to screen six items of PKU, congenital hypothyroidism, maple syrup urine disease, homocystinuria, galactosemia and congenital adrenal hyperplasia from 2006. In 2014, thirteen laboratories are participating. Inter laboratory quality control was started 6 times a year from 1994. In case a patient with an inherited metabolic disease is diagnosed by screening of government program, special milk is provided at government's expense. According to the government project, from 1997 to 2013, 7,080,569 newborns were screened. 144 PKU, 2.451 congenital hypothyroidism were detected. So incidence of PKU is 1/49,170 and congenital hypothyroidism is 1/2,888. The cost benefit of performing screening procedures coupled with treatment has been estimated to be as high as 1.77 times in PKU, 11.11 times in congenital hypothyroidism than cost without screening. By January 2007, many European countries had expanded of their newborn screening programs by inclusion of Tandem mass spectrometry. We are trying to increase the budget to test all newborns for Tandem mass spectrometry from 2016. We are considering four to five central laboratories which cover all newborns and are equipped with tandem mass spectrometer & enzyme immunoassay for TSH, 17OHP & enzyme colorimetric assay for galactose. And I hope to expand test including Wilson disease screening test and lysosomal storage diseases.
Lee, Ji Hoon;Kim, Sung Woo;Jeon, Ga Won;Sin, Jong Beom
Clinical and Experimental Pediatrics
/
v.58
no.6
/
pp.224-229
/
2015
Purpose: Thyroid dysfunction is common in preterm infants. Congenital hypothyroidism causes neurodevelopmental impairment, which is preventable if properly treated. This study was conducted to describe the characteristics of thyroid dysfunction in very low birth weight infants (VLBWIs), evaluate risk factors of hypothyroidism, and suggest the reassessment of thyroid function with an initially normal thyroid-stimulating hormone (TSH) as part of a newborn screening test. Methods: VLBWIs (January 2010 to December 2012) were divided into two groups according to dysfunction-specific thyroid hormone replacement therapy, and associated factors were evaluated. Results: Of VLBWIs, 246 survivors were enrolled. Only 12.2% (30/246) of enrolled subjects exhibited thyroid dysfunction requiring thyroid hormone replacement. Moreover, only one out of 30 subjects who required thyroid hormone treatment had abnormal thyroid function in the newborn screening test with measured TSH. Most of the subjects in the treatment group (22/30) exhibited delayed TSH elevation. Gestational age, Apgar score, antenatal steroids therapy, respiratory distress syndrome, patent ductus arteriosus, sepsis, intraventricular hemorrhage, postnatal steroids therapy, and duration of mechanical ventilation did not differ between the two groups. Birth weight was smaller and infants with small for gestational age were more frequent in the treatment group. Conclusion: Physicians should not rule out suggested hypothyroidism, even when thyroid function of a newborn screening test is normal. We suggest retesting TSH and free thyroxine in high risk preterm infants with an initially normal TSH level using a newborn screening test.
Journal of mucopolysaccharidosis and rare diseases
/
v.3
no.1
/
pp.14-19
/
2017
Lysosomal storage diseases (LSDs) are a group of rare inherited metabolic disorders caused by the deficiency of specific lysosomal enzymes and subsequent accumulation of substrates. Enzyme deficiency leads to progressive intra-lysosomal accumulation of the incompletely degraded substances, which cause dysfunction and destruction of the cell and eventually multiple organ damage. Patients have a broad spectrum of clinical phenotypes which are generally not specific for some LSDs, leading to missed or delayed diagnosis. Due to the availability of treatment including enzyme replacement therapy (ERT) and hematopoietic stem cell transplantation for some LSDs, early diagnosis is important. ERT products have been approved with optimal outcomes for some LSDs in the recent decades, including Gaucher, Fabry, mucopolysaccharidosis (MPS) I, Pompe, MPS VI, MPS II, and MPS IVA diseases. ERT can stabilize the clinical condition, prevent disease progression, and improve the long-term outcome of these diseases, especially if started prior to irreversible organ damage. Based on the availability of therapy and suitable screening methods in the recent years, some LSDs, including Pompe, Fabry, Gaucher, MPS I, MPS II, and MPS VI diseases have been incorporated into nationwide newborn screening panels in Taiwan.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.