• Title/Summary/Keyword: New regeneration energy

Search Result 71, Processing Time 0.028 seconds

Performance Characteristics Analysis of Combined Cycle Using Regenerative Organic Rankine Cycle and LNG Cold Energy (LNG 냉열과 재생 유기 랭킨 사이클을 이용한 복합 사이클의 성능 특성 해석)

  • KIM, KYOUNG HOON;JUNG, YOUNG GUAN;HAN, CHUL HO
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.2
    • /
    • pp.234-241
    • /
    • 2020
  • This paper presents a thermodynamic performance analysis of a combined cycle consisting of regenerative organic Rankine cycle (ORC) and liquefied natural gas (LNG) Rankine cycle to recover low-grade heat source and the cold energy of LNG. The mathematical models are developed and the system performances are analyzed in the aspect of thermodynamics. The effects of the turbine inlet pressure and the working fluid on the system performance such as the mass flow rates, heat transfers at heat exchangers, power productions at turbines, and thermal efficiency are systematically investigated. The results show that the thermodynamic performance of ORC such as net power production and thermal efficiency can be significantly improved by the regenerative ORC and the LNG cold energy.

Exergy Analysis of Regenerative Ammonia-Water Rankine Cycle for Use of Low-Temperature Heat Source (저온열원 활용을 위한 암모니아-물 재생 랭킨사이클의 엑서지 해석)

  • Kim, Kyoung-Hoon;Ko, Hyung-Jong;Kim, Se-Woong
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.1
    • /
    • pp.65-72
    • /
    • 2012
  • Rankine cycle using ammonia-water mixture as a working fluid has attracted much attention, since it may be a very useful device to extract power from low-temperature heat source. In this work, the thermodynamic performance of regenerative ammonia-water Rankine cycle is thoroughly investigated based on the second law of thermodynamics and exergy analysis, when the energy source is low-temperature heat source in the form of sensible energy. In analyzing the power cycle, several key system parameters such as ammonia mass concentration in the mixture and turbine inlet pressure are studied to examine their effects on the system performance including exergy destructions or anergies of system components, efficiencies based on the first and second laws of thermodynamics. The results show that as the ammonia concentration increases, exergy exhaust increases but exergy destruction at the heat exchanger increases. The second-law efficiency has an optimum value with respect to the ammonia concentration.

An Environment-friendly Analysis of Hong-kong Environment-friendly Reuse Space (홍콩 친환경 재생공간의 친환경성 분석)

  • Kim, Sarah;Nam, Kyoung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.3
    • /
    • pp.194-202
    • /
    • 2012
  • The purpose of this study is to extract environment-friendly planning elements to apply in Korea by putting together and reclassifying four foreign environment-friendly certification systems related to regeneration spaces - LEED in USA, CASBEE in Japan, BREEAM in England and BEAM in Hong Kong - and analyze and evaluate domestic and foreign spaces which were certified as Environment-friendly spaces in order to offer plan guidelines to raise awareness of the importance of environment-friendly elements in regeneration spaces and to encourage them. The concept and the characteristics of green building were studied through documentary survey. In addition, green certification system of the present domestic new spaces and foreign regeneration spaces was studied and assessment tools for indoor regenerated spaces-related green certification system were developed. With checklists which are developed in this study, level of going green of foreign spaces certified environment-friendly was assessed. Based on the results of this study, conclusions are as follows. As a result of case research of spaces-certified green of Hong-Kong's existing buildings with a developed checklist, application of general assessment part was all alike, but that of detailed assessment part was different. However, Hong Kong showed superiority in lighting energy saving, separate collection of recyclable domestic waste, recycling by-product and management. In addition, Hong Kong applied eco-friendly planning elements maintaining buildings in their condition as possible as it could with management, use of green program, replacement with high efficiency lighting, monitoring system, installation of recycling bins and energy saving by attaching reflective film.

  • PDF

Performance characterization of liquid desiccant system with extended surface (확장표면을 적용한 액체식 제습시스템의 성능특성에 관한 연구)

  • Jang, Young-Soo;Song, Gwi-Eun;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.639-644
    • /
    • 2009
  • This study presents the new idea of liquid desiccant system with extended surface to reduce the system size. The extended surface is inserted between vertical cooling/heating tubes to increase the mass transfer area, and the liquid desiccant flows through the tube wall and the extended surface. Mathematical models for heat and mass transfer between liquid desiccant and air stream at tube wall and extended surface are provided. Dimensionless design parameters governing heat and mass transfer phenomena around the tube and the extended surface are identifier, and dimensionless operating parameters depicting system operating condition including flow rate ratio between dehumidification/regeneration processes, and mass flow rate ratio between air stream and liquid desiccant are explained. The effects of the parameters on system performance are summarized.

  • PDF

A Control Design of Energy Storage System for Electric Railway Vehicle Using Supercapacitor (슈퍼커패시터를 이용한 전동차량용 에너지저장시스템의 제어기 설계)

  • Noh, Se-Jin;Lee, Jin-Mok;Son, Kyoung-Min;Choi, Eun-Jin;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.994-995
    • /
    • 2008
  • It is possible to suppress voltage drops, power loading fluctuations and regeneration power lapses for DC railway systems by applying an energy storage system. A electric double layer capacitor (EDLC) of the rapid charge/discharge type has been developed and used in wide ranges. It has a long life, high efficiency and maintenance free/low pollution features as a new energy storage element. In this paper, an efficient charge and discharge control method of a bidirectional DC-DC converter using the supercapacitor is proposed.

  • PDF

A Study on the Low-carbon Urban Regeneration Planning Elements and System in Climate Change Era. (기후변화대응 탄소저감형 도시재생 계획 요소 및 체계에 관한 연구)

  • Choi, Joung-eun;Choi, Joon-Sung;Oh, Deog-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6345-6359
    • /
    • 2015
  • This study aims to clarify the concept of 'Low-carbon urban regeneration', to extract planning elements according to it, and to establish the planning system. In order to extract the elements, matrix analysis was conducted between planning elements of urban regeneration and Low-carbon cities, and the focus group interview(FGI) was used. Derived elements from this process were restructured for the new planning system. In addition, in-depth case analysis was performed to verify the suitability and effects of planning elements and system. The result showed that planning element of Low-carbon urban regeneration can be sorted in 37 elements in 5 categories. In-depth analysis indicated that established planning elements were importantly dealt in cases and played a significant role in urban regeneration and carbon reduction. Also, it showed that those elements had a significant relationship with adaptation and mitigation, the two responding strategies to the climate change. Elements highly contributing to urban regeneration were Urban Structure, Transportation, Policy while elements affecting carbon reduction were Transportation, Green & Blue space, Energy & Material field.

Selective Separation of Hydrogen from Gas Mixture using LaNi5 (LaNi5를 이용한 혼합기체로부터 수소의 선택적 분리)

  • Sun, Yang Kook;Nahm, Kee Suk;Lee, Wha Young
    • Journal of Hydrogen and New Energy
    • /
    • v.1 no.1
    • /
    • pp.15-23
    • /
    • 1989
  • The selective separation of hydrogen from gas mixture containing hydrogen was experimentally studied using $LaNi_5$. The capacity and the rate of hydrogen separation, the purity of recovered hydrogen and the optimum condition of the regeneration of deactivated $LaNi_5$ were investigated. The separation rate and the recovery ratio of hydrogen were slowly decreased with the increase of the number of hydrogen absorption cycle. It was found that this result comes from the deactivation of $LaNi_5$ partly because of the blocking of hydrocarbon compounds in the $LaNi_5$ lattice and partly because of the poisoning of $LaNi_5$ surface by carbon monoxide contained in the gas mixture. The optimum condition for the regeneration of deactivated $LaNi_5$ was obtained by heating in a vacuum to about 637 K. The recovery ratio of hydrogen at the optimum condition was observed to be about 80%. The rates of hydrogen separation were measured in the ${\alpha}$-phase and two phase regions. The rate equations could be expressed as follows ; ${\alpha}$ - phase : $$-\frac{dP{_{H_2}}}{dt}=9.836{\times}10^{-3}(P{_{H_2}}_{-P_{eq}})$$ two phase region : $$-\frac{dP_{H{_2}}}{dt}=1.6909{\times}10^2\exp(-17560/RT)(P{_{H_2}}_{-P_{eq}})$$.

  • PDF

Hydrogen Generation Characteristics of SMART System with Inherent $CO_2/H_2$ Separation ($CO_2/H_2$ 원천분리 SMART 시스템의 수소생산특성)

  • Ryu, Ho-Jung
    • Journal of Hydrogen and New Energy
    • /
    • v.18 no.4
    • /
    • pp.382-390
    • /
    • 2007
  • To check the feasibility of SMART(Steam Methane Advanced Reforming Technology) system, an experimental investigation was performed. A fluidized bed reactor of diameter 0.052m was operated cyclically up to 10th cycle, alternating between reforming and regeneration conditions. FCR-4 catalyst was used as the reforming catalyst and calcined limestone(domestic, from Danyang) was used as the $CO_2$ absorbent. Hydrogen concentration of 98.2% on a dry basis was reached at $650^{\circ}C$ for the first cycle. This value is much higher than $H_2$ concentration of 73.6% in the reformer of conventional SMR (steam methane reforming) condition. The hydrogen concentration decreased because the $CO_2$ capture capacity decreased as the number of cycles increased. However, the average hydrogen concentration at 10th cycle was 82.5% and this value is also higher than that of SMR. Based on these results, we could conclude that the SMART system can replace SMR system to generate pure hydrogen without HTS (high tempeature shift), LTS (low temperature shift) and $CO_2$ separation process.

Establishment of Callus Induction and Plant Regeneration System from Mature Seeds of Miscanthus sinensis (억새(Miscanthus sinensis) 성숙 종자로부터의 캘러스 유도 및 식물체 재분화 체계 확립)

  • Cho, Joon-Hyeong;Byeon, Ji-Hui
    • Korean Journal of Plant Resources
    • /
    • v.24 no.5
    • /
    • pp.628-635
    • /
    • 2011
  • This study was conducted to establish the tissue culture system for Korean domestic Miscanthus sinensis, which is used in various purposes such as forage, and bio-energy resources. With the mature seed of Miscanthus, optimum concentrations of plant growth regulators were identified for an efficient callus induction and regeneration. Among the treatments of 1~10 $mg{\cdot}L^{-1}$ 2,4-D, IBA, or NAA, callus induction rate was highest (85.3%) on MS medium containing 5 $mg{\cdot}L^{-1}$ 2,4-D. Under the condition, the callus were efficiently induced and proliferated with comparably lower frequencies of callus browning. In shoot regeneration, the treatment of NAA combined with BAP seemed to contribute more efficient conditions to shoot regeneration than those of NAA with Kinetin or 2-iP. Especially, regeneration efficiency and number of regenerated plants were 83.7% and 5.5 in 3 $mg{\cdot}L^{-1}$ NAA with 5 $mg{\cdot}L^{-1}$ BAP, respectively, which were higher frequencies than those in NAA with Kinetin or 2-iP. In results, 5 $mg{\cdot}L^{-1}$ 2,4-D and 3 $mg{\cdot}L^{-1}$ NAA combined with 5 $mg{\cdot}L^{-1}$ BAP were efficient for embryogenic callus induction and regeneration of Miscanthus. This system would be useful for mass-propagation and developing new cultivars via tissue culture of Miscanthus sinensis.

Effect on the Heat of Reaction to Temperature and Absorption Capacity in the Reaction of Cyclic Amines with Carbon Dioxide (고리형 아민과 이산화탄소의 반응에서 온도와 흡수능이 반응열에 미치는 영향)

  • CHOI, JEONG HO;JANG, JONG TACK;YUN, SOUNG HEE;JO, WON HEE;JUNG, JIN YOUNG;YOON, YEO IL
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.5
    • /
    • pp.530-537
    • /
    • 2018
  • The effect of temperature and absorption capacity on heat of reaction, which is one of the characteristic studies of $CO_2$ absorption, were investigated in a differential reaction calorimeter (DRC) by using piperazine (PZ) and 2-methylpiperazine (2-MPZ). For all absorbents, $CO_2$ loading capacity decreased with increasing the temperature, while the heat of reaction increased, it figured out that these had a linear correlation between $CO_2$ loading capacity and/or heat of reaction and the temperature. The heat of reaction of all absorbents increased with increasing $CO_2$ loading capacity, especially 2-MPZ rapidly increased at $70^{\circ}C$. The reason for increase in the heat of reaction was occurred the regeneration of $CO_2$, which is a reverse-reaction, simultaneously with the absorption.