• Title/Summary/Keyword: New correction factor

Search Result 309, Processing Time 0.025 seconds

New CCM Single Stage PFC Full Bridge Converter (새로운 CCM 단일 전력단 역률보상 풀 브리지 컨버터)

  • Lim, Chang-Seob;Kwon, Soon-Kurl;Cho, Jung-Goo;Song, Doo-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.986-989
    • /
    • 2002
  • This paper proposes a new single stage power factor correction (PFC) full bridge converter which operates at continuous conduction mode(CCM). The proposed single stage PFC consists of typical zero voltage switching(ZVS) full bridge DC/DC converter, two transformer auxiliary windings, and two small inductors, and two diodes. Neither additional active switch nor any control circuit are added for PFC resulting in very low cost. The proposed converter provides input power factor correction with CCM control and tight output voltage regulation. All switching devices are operated under ZVS with minimum voltage stress. Operation principle and analysis are explained and verified with computer simulation and experimental results on a 1.2kW, 100kHz prototype.

  • PDF

A New Power Factor Correction Circuit Using Boost Converter (부스트 컨버터를 이용한 새로운 역율 개선회로)

  • Kim, Marn-Go
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.355-357
    • /
    • 1996
  • With the wide-spread use of rectifier in electronic equipments, such problems as electronic components failures or equipment disorders have been occurred due to current harmonics. To overcome these problems, power factor correction circuits employing boost converter have been used. The switching stress of boost converter can be reduced by snubber circuit. Recently, research activities in snubber circuits have been directed to energy recovery snubber for improving the efficiency of power converter. In this study, a new passive snubber circuit which can recover trapped snubber energy without added control is proposed for boost converter The control of boost converter with proposed snubber is the same as the conventional one. In addition, the energy recovery circuit can be implemented with a few passive components. The circuit operation is confirmed through simulation.

  • PDF

Modeling and Small-Signal Analysis of Controlled On-time Boost Power Factor Correction Circuit (도통 시간 제어형 승압형 역률보상회로의 모델링과 소신호 해석)

  • Park, Hyo-Gil;Hong, Seong-Su;Choe, Byeong-Jo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.5
    • /
    • pp.364-370
    • /
    • 2000
  • A large-signal average model for the controlled on-time boost power factor correction(PFC) circuit is developed and subsequently linearized resulting in a small-signal model for the PFC circuit. Ac analyses are performed using the small-signal model, revealing new results new on small-signal dynamics of the PFC circuit. The analysis results and model predictions are confirmed with experimental measurements on 200W prototype PFC circuit.

  • PDF

Novel Single-Stage Power Factor Correction AC/DC Converter with Low DC Link Voltage using New Magnetic Feedback Technique (새로운 마그네틱 피드백 기법을 이용하여 낮은 링크 전압을 갖는 새로운 단일 전력단 역률 개선 AC/DC 컨버터)

  • Choi E. S.;Yoon H. K.;Kim C. E.;Moon G. W.;Youn M. J.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.528-532
    • /
    • 2004
  • Novel single-stage power factor correction AC/DC converter with low DC link voltage using new magnetic feedback technique is proposed in this paper. The Proposed converter has high power factor, tight output voltage regulation and low link capacitor voltage less than 450V for all the load range through the universal input line. This converter has also no dead-zone in the input current, which is seen in the conventional converter using the previous magnetic feedback technique. In this paper, the analysis of operations and features of the proposed converter is provided, and the experimental results of 90W-prototype shows the low harmonic distortions satisfied with EN 61000-3-2 Class D, high power factor and low link voltage less than 450V.

  • PDF

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

A Study on Path Loss Prediction for the PNG of Russia Using the Free Space Model and the Hata Model (자유 공간 모델과 하타 모델을 이용한 러시아 PNG 지역의 경로 손실 예측에 관한 연구)

  • Park, Kyung-Tae;Cho, Hyung-Rae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.5
    • /
    • pp.87-92
    • /
    • 2011
  • In this paper, we got the 800 ~ 900 MHz path loss model for Russia PNG area using the free space model and the Okumura-Hata Model. In order to add new regional properties to the existing path loss model, the mean square error technique is used to obtain the correction factor. The correction factors for the free space and the Hata model are 28, 13 dB respectively. By applying this correction factors, the new Russain PNG path loss model is proposed.

Power Factor Correction Method without Input Current Sensor (입력전류센서 없는 단상전력변환기의 역률개선 기법)

  • Jung, Young-Seok;Moon, Gun-Woo;Rho, Chung-Wook;Lee, Jun-Young;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.564-566
    • /
    • 1996
  • New simple control method of power factor correcting(PFC) boost convertor without instantaneous measurement of input current is proposed. Using the averaged model, the power factor correction scheme is presented. With the measurements of input voltage and output voltage, the control signal is generated to make the shape of the line current same as the input voltage. The validity of the controller is verified through the computer simulations.

  • PDF

A Simple Continuous Conduction Mode PWM Controller for Boost Power Factor Correction Converter

  • Tanitteerapan, Tanes;Mori, Shinsaku
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.1030-1033
    • /
    • 2002
  • This paper, a new simple controller operates in continuous conduction mode (CCM) for Boost power factor collection converter is introduced. The duty ratios are obtained by comparisons of a sensed signal from inductor current and a negative ramp carrier waveform in each switching period. By using the proposed controller, input voltage sensing, error amplifier in the current feedback loop, and analog multiplier/divider are not required, then, the control circuit implementation is very simple. To verify the proposed controller, the circuit simulation for Boost power factor correction converter was applied. For the results, the input current waveform was shaped to be closely sinusoidal, implying low THD.

  • PDF

Power Factor Correction of the Single-State AC/DC Converter with Low conduction Loss and High Efficiency

  • Ryu, Myung-Hyo;Choi, Byungcho;Kim, Heung-Geun;Cha, Young-Kil
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.281-286
    • /
    • 1998
  • This paper proposes a new single-stage, single-switch AC/DC converter based on the boost power factor correction (PFC) cell. The converter offers both high power factor and high efficiency. To reduce the dc voltage on the energy storage capacitor, the dc bus voltage feedback method was used. A 100W (5V/20A) prototype was built and tested to show the validity of the proposed converter.

  • PDF

Novel Zero-Voltage-Switching Bridgeless PFC Converter

  • Haghi, Rasool;Zolghadri, Mohammad Reza;Beiranvand, Reza
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.40-50
    • /
    • 2013
  • In this paper, a new zero-voltage-switching, high power-factor, bridgeless rectifier is introduced. In this topology, an auxiliary circuit provides soft switching for all of the power semiconductor devices. Thus the switching losses are reduced and the highest efficiency can be achieved. The proposed converter has been analyzed and a design procedure has been introduced. The control circuit for the converter has also been developed. Based on the given approach, a 250 W, 400 Vdc prototype converters has been designed at 100 kHz for universal input voltage (90-264 Vrms) applications. A maximum efficiency of 94.6% and a power factor correction over 0.99 has been achieved. The simulation and experimental results confirm the design procedure and highlight the advantages of the proposed topology.