• Title/Summary/Keyword: Neutrons

Search Result 310, Processing Time 0.026 seconds

Assaying of SNM using Simultaneous Detection of Fission Neutrons and Gammas by Employing a Novel Phoswich Detector

  • Sonu;Mohit Tyagi;A. Kelkar;A. Sahu;M. Sonawane;P.S. Sarkar;A. Pandey;D.B. Sathe;G.D. Patra;T. Vincent;S.G. Singh;R.B. Bhatt
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2662-2669
    • /
    • 2023
  • For the precise measurements of special nuclear materials (SNM) including Pu and Am isotopes, we have used phoswich detector combination of two single crystal scintillators of Gd3Ga3Al2O12:Ce and CsI:Tl. High detection efficiency and sensitivity along with high figure of merit for the discrimination of these phoswich detectors ensures the detection and discrimination of thermal neutrons and gammas from spontaneous fission of Pu and other isotopes in presence of high gamma background. Using this detector, the low energy gammas, which is stopped completely in 1mm thick disc of GGAG, can be also discriminated from high energies gamma and shows linearity in wide range of sample quantities. By changing only the appropriate shielding, the similar setup was used for thermal neutron detection and shows a very good linearity over wide range. The quantity of a test sample was also calculated accurately by using the measured calibrated plot.

Enhancing Gamma-Neutron Shielding Effectiveness of Polyvinylidene Fluoride for Potent Applications in Nuclear Industries: A Study on the Impact of Tungsten Carbide, Trioxide, and Disulfide Using EpiXS, Phy-X/PSD, and MCNP5 Code

  • Ayman Abu Ghazal;Rawand Alakash;Zainab Aljumaili;Ahmed El-Sayed;Hamza Abdel-Rahman
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.184-196
    • /
    • 2023
  • Background: Radiation protection is crucial in various fields due to the harmful effects of radiation. Shielding is used to reduce radiation exposure, but gamma radiation poses challenges due to its high energy and penetration capabilities. Materials and Methods: This work investigates the radiation shielding properties of polyvinylidene fluoride (PVDF) samples containing different weight fraction of tungsten carbide (WC), tungsten trioxide (WO3), and tungsten disulfide (WS2). Parameters such as the mass attenuation coefficient (MAC), half-value layer (HVL), mean free path (MFP), effective atomic number (Zeff), and macroscopic effective removal cross-section for fast neutrons (ΣR) were calculated using the Phy-X/PSD software. EpiXS simulations were conducted for MAC validation. Results and Discussion: Increasing the weight fraction of the additives resulted in higher MAC values, indicating improved radiation shielding. PVDF-xWC showed the highest percentage increase in MAC values. MFP results indicated that PVDF-0.20WC has the lowest values, suggesting superior shielding properties compared to PVDF-0.20WO3 and PVDF-0.20WS2. PVDF-0.20WC also exhibited the highest Zeff values, while PVDF-0.20WS2 showed a slightly higher increase in Zeff at energies of 0.662 and 1.333 MeV. PVDF-0.20WC has demonstrated the highest ΣR value, indicating effective shielding against fast neutrons, while PVDF-0.20WS2 had the lowest ΣR value. The Monte Carlo N-Particle Transport version 5 (MCNP5) simulations showed that PVDF-xWC attenuates gamma radiation more than pure PVDF, significantly decreasing the dose equivalent rate. Conclusion: Overall, this research provides insights into the radiation shielding properties of PVDF mixtures, with PVDF-xWC showing the most promising results.

Gamma/neutron classification with SiPM CLYC detectors using frequency-domain analysis for embedded real-time applications

  • Ivan Rene Morales;Maria Liz Crespo;Mladen Bogovac;Andres Cicuttin;Kalliopi Kanaki;Sergio Carrato
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.745-752
    • /
    • 2024
  • A method for gamma/neutron event classification based on frequency-domain analysis for mixed radiation environments is proposed. In contrast to the traditional charge comparison method for pulse-shape discrimination, which requires baseline removal and pulse alignment, our method does not need any preprocessing of the digitized data, apart from removing saturated traces in sporadic pile-up scenarios. It also features the identification of neutron events in the detector's full energy range with a single device, from thermal neutrons to fast neutrons, including low-energy pulses, and still provides a superior figure-of-merit for classification. The proposed frequency-domain analysis consists of computing the fast Fourier transform of a triggered trace and integrating it through a simplified version of the transform magnitude components that distinguish the neutron features from those of the gamma photons. Owing to this simplification, the proposed method may be easily ported to a real-time embedded deployment based on Field-Programmable Gate Arrays or Digital Signal Processors. We target an off-the-shelf detector based on a small CLYC (Cs2LiYCl6:Ce) crystal coupled to a silicon photomultiplier with an integrated bias and preamplifier, aiming at lightweight embedded mixed radiation monitors and dosimeter applications.

Frequency of Micronuclei in Lymphocytes Following Gamma and Fast-neutron Irradiations (방사선 조사량에 따른 인체 정상 림파구의 미세핵 발생빈도)

  • Kim Sung-Ho;Cho Chul-Koo;Kim Tae-Hwan;Chung In-Yong;Yoo Seong-Yul;Koh Kyoung-Hwan;Yun Hyong-Geun
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.35-42
    • /
    • 1993
  • The dose response of the number of micronuclei in cytokinesis-blocked (CB) lymphocytes after in vitro irradiation with $\gamma$-rays and neutrons in the 5 dose ranges was studied for a heterogeneous population of 4 donors. One thousand binucleated cells were systematically scored for micronuclei. Measurements performed after irradiation showed a dose-dependent increase in micronuclei (MN) frequency in each of the donors studied. The dose-response curves were analyzed by a linear-quadratic model, frequencies per 1000 CB cells were ($0.31{\pm}0.049$)D+($0.0022{\pm}0.0002)D^2+(13.19{\pm}1.854) (r^2=1.000,\;X^2=0.7074,\;p=0.95$) following $\gamma$ irradiation, and ($0.99{\pm}0.528$)\;D+(0.0093{\pm}0.0047)\;D^2+(13.31{\pm}7.309)\;(r^2=0.996,\;X^2=7.6834,\;p=0.11) following neutrons irradiation (D is irradiation dose in cGy). The relative biological effectiveness (RBE) of neutrons compared with $\gamma$-rays was estimated by best fitting linear-quadratic model. In the micronuclei frequency between 0.05 and 0.8 per cell, the RBE of neutrons was $2.37{\pm}0.17$. Since the MN assay is simple and rapid, it may be a good tool for evaluating the $\gamma$-ray and neutron response.

  • PDF

Estimation of Neutron Absorption Ratio of Energy Dependent Function for $^{157}Gd$ in Energy Region from 0.003 to 100 eV by MCNP-4B Code

  • Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.3
    • /
    • pp.23-25
    • /
    • 2009
  • Gd-157 material has very large neutron capture cross section in the thermal region. So it is very useful to shield material for thermal neutrons. Futhermore, in the neutron capture experiment and calculation, the neutron absorption and scattering are very important. Especially these effects are conspicuous in the resonance energy region and below the thermal energy region. In the case of very narrow resonance, the effect of scattering is to be more considerable factor. In the present study, we obtained energy dependent neutron absorption ratios of natural indium in energy region from 0.003 to 100 keV by MCNP-4B Code. The coefficients for neutron absorption was calculated for circular type and 1 mm thickness. In the lower energy region, neutron absorption is larger than higher region, because of large capture cross section (1/v). Furthermore it seems very different neutron absorption in the large resonance energy region. These results are very useful to decide the thickness of sample and shielding materials.

  • PDF

Radioactive Neutron Source Calibration at the Korea Standards Research Institute (K-SRI 에서의 방사성 중성자 선원교정)

  • Hwang, Sun-Tae;Choi, Kil-Oung
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.67-73
    • /
    • 1985
  • The manganous sulfate bath method for neutron source calibrations at the K-SRI is described together with the measurement of neutron emission rate of a source and the corrections applied for capture by competing nuclei of neutrons, and thermal neutron leakage, neutron absorption in the source itself. The commercially available neutron sources (Am-Be, $^{252}Cf$) for the calibration checks of neutron radiation instruments in the MeV range are considered in this paper.

  • PDF

Irradiation Induced Defects in a Si-doped GaN Single Crystal by Neutron Irradiation

  • Park, Il-Woo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.12 no.2
    • /
    • pp.74-80
    • /
    • 2008
  • The local structure of defects in undoped, Si-doped, and neutron irradiated free standing GaN bulk crystals, grown by hydride vapor phase epitaxy, has been investigated by employing electron magnetic resonance(EMR), Raman scattering and cathodoluminescence. The GaN samples were irradiated to a dose of $2{\times}10^{17}$ neutrons in an atomic reactor at Korea Atomic Energy Research Institute. There was no appreciable change in the Raman spectra for undoped GaN samples before and after neutron irradiation. However, a forbidden transition, $A_1$(TO) mode, appeared for a neutron irradiated Si-doped GaN crystal. Cathodoluminescence spectrum for the neutron irradiated Si-doped GaN crystal became much broader or was much more broadened than that for the unirradiated one. The observed EMR center with the g value of 1.952 in a neutron irradiated Si-doped GaN may be assigned to a Si-related complex donor.

Neutron Diffraction Study of Powders Prepared by Self-propagating High Temperature Synthesis

  • Park, Yong;Kim, Y S.;Y. D. Hahn;S. H. Shim;Lee, J. S.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2000.11a
    • /
    • pp.11-12
    • /
    • 2000
  • Non-stoichiometric ceramics of $Ni_{x}ZnO_{1-x}Fe_{2}O_{4}$ were prepared by self-propagating high temperature synthesis reaction with various processing conditions and their stoichometric numbers were determined by neutron diffraction. The neutron diffraction patterns were measured at room temperature using monochromatic neutrons with a wave length of 0.18339 nm from a Ge(331) mocochromator at a 90 degree take off angle. The Rietveld refinement of each pattern converged to good agreement (x2=1.88-2.24). The neutron diffraction analysis revealed the final stoichiometries of the ferrites were $Ni_{0.38}Zn_{0.62}Fe_{2}O_{4}$ and $Ni_{0.33}Zn_{0.67}Fe_{2}O_{4]$, respectively. This supports that final stoichiometric number of the self-propagating high temperature synthesis product can be controlled by the processing parameters during the combustion reaction.

  • PDF

Design of a High Stable Measuring Circuit for Radioactive Pulses (방사선 펄스의 고안정 계측회로 설계)

  • 송재용;한주섭;천상규;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.577-580
    • /
    • 2000
  • The aim of this paper is to develop a high stable measuring device for radioactive pulses. The device consists of a high voltage supply unit using a fly-back converter principle, and a pulse detection unit for gamma-rays and neutrons. The high voltage supply unit designed can generate DC voltage up to 1,500v at 5V-input, and have a series voltage regulator to maintain the output voltage constantly, resulting in less than 1.63% of voltage regulation. The pulse detection parts consists of an active integrator, a pole-zero circuit, and a 3-stage amplifier of 60 dB, and its frequency bandwidth is from 37 Hz to 300 kHz. From the experimental results, it is confirmed that the measuring device can count at least 10,000 pulses in a second.

  • PDF

Manufacture and Experiment of Compensated Ionization Chamber for the Nuclear Power Reactor (동력로용 보상형 전리함의 제작 및 실험)

  • 육종철;고병준;박용집
    • 전기의세계
    • /
    • v.19 no.4
    • /
    • pp.18-23
    • /
    • 1970
  • A neutron detector, in general, can not be utilized as the thermal neutron detecting chamber in the nuclear power reactor, especially P.W.R. due to the characteristics of high temperature, high pressure and high neutron flux in a reactor vessel. We have performed an experiment to detect the thermal neutrons at 400.deg. C and high flux of thermal neutron in a power reactor. Coating boron-10 on the aluminium plates by means of surface diffusion method at 600.deg. C for 5 hours in an electric furace, also we made a typical chamber which was compensated ionization chamber filled with free air as an ionization gas. It was checked the chamber characteristics in the TRIGA MARK-II Reactor at the power level from zero to 250KW. The chamber current showed a perfect linear increase to power increase. However, many variation of the measured current were observed within the power of 50KW.

  • PDF