• 제목/요약/키워드: Neutron scintillation detector

검색결과 21건 처리시간 0.032초

4.2分의 短壽命 Thallium-206의 放射化分析 (Activation-Analysis of trace Thallium in Meteorites, Rocks, Minerals, Alloys, and Biological Samples using 4.2-Minute Thallium-206)

  • 김종국
    • 대한화학회지
    • /
    • 제5권1호
    • /
    • pp.26-28
    • /
    • 1961
  • Microgram quantities of thallirum in meteorites, rocks, minerals, alloys and biological samples have been analyzed by rapid neutron activation analysis. A l0-minute radiochemical separation procedure coupled with a gas-flow proportional detector for 4.2-minute half life measurement and a gamma or beta scintillation detector placed in close proximity to the sample permitted detection of the 4.2-min Tl206. Samples were irradiated for 10-minutes at a thermal neutron flux of approximately $0.95{\times}10^{11}$ neutron-$cm^{-2}-sec^{-1}.$ The low limits of detection was about $10^{-7}$ gm of thallium.

  • PDF

Comparison of Machine Learning-Based Radioisotope Identifiers for Plastic Scintillation Detector

  • Jeon, Byoungil;Kim, Jongyul;Yu, Yonggyun;Moon, Myungkook
    • Journal of Radiation Protection and Research
    • /
    • 제46권4호
    • /
    • pp.204-212
    • /
    • 2021
  • Background: Identification of radioisotopes for plastic scintillation detectors is challenging because their spectra have poor energy resolutions and lack photo peaks. To overcome this weakness, many researchers have conducted radioisotope identification studies using machine learning algorithms; however, the effect of data normalization on radioisotope identification has not been addressed yet. Furthermore, studies on machine learning-based radioisotope identifiers for plastic scintillation detectors are limited. Materials and Methods: In this study, machine learning-based radioisotope identifiers were implemented, and their performances according to data normalization methods were compared. Eight classes of radioisotopes consisting of combinations of 22Na, 60Co, and 137Cs, and the background, were defined. The training set was generated by the random sampling technique based on probabilistic density functions acquired by experiments and simulations, and test set was acquired by experiments. Support vector machine (SVM), artificial neural network (ANN), and convolutional neural network (CNN) were implemented as radioisotope identifiers with six data normalization methods, and trained using the generated training set. Results and Discussion: The implemented identifiers were evaluated by test sets acquired by experiments with and without gain shifts to confirm the robustness of the identifiers against the gain shift effect. Among the three machine learning-based radioisotope identifiers, prediction accuracy followed the order SVM > ANN > CNN, while the training time followed the order SVM > ANN > CNN. Conclusion: The prediction accuracy for the combined test sets was highest with the SVM. The CNN exhibited a minimum variation in prediction accuracy for each class, even though it had the lowest prediction accuracy for the combined test sets among three identifiers. The SVM exhibited the highest prediction accuracy for the combined test sets, and its training time was the shortest among three identifiers.

A technique for the reduction of pulse pile-up effect in pulse-shape discrimination of organic scintillation detectors

  • Nakhostin, M.
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.360-365
    • /
    • 2020
  • A technique for the reduction of pulse pile-up effect in digital pulse-shape discrimination (PSD) of neutrons and gamma-rays with organic scintillation detectors is presented. The technique is based on an electronic reduction of the effective decay-time constant of scintillation pulses while retaining the PSD information of the pulses. The experimental results obtained with a NE213 liquid scintillation detector in a mixed radiation field of neutrons and gamma-rays are presented, demonstrating a figure of merit (FOM) of 1.20 ± 0.05 with an energy threshold of 350 keVee (electron equivalent energy) when the effective length of the pulses is reduced to 50 ns.

Upgrade of Neutron Energy Spectrometer with Single Multilayer Bonner Sphere Using Onion-like Structure

  • Mizukoshi, Tomoaki;Watanabe, Kenichi;Yamazaki, Atsushi;Uritan, Akira;Iguchi, Tetsuo;Ogata, Tomohiro;Muramatsu, Takashi
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.185-190
    • /
    • 2016
  • Background: In order to measure neutron energy spectra, the conventional Bonner Sphere Spectrometers (BSS) are widely used. In this spectrometer, several measurements with different size Bonner spheres are required. Operators should, therefore, place these spheres in several times to a measurement point where radiation dose might be relatively high. In order to reduce this effort, novel neutron energy spectrometer using an onion-like single Bonner sphere was proposed in our group. This Bonner sphere has multiple sensitive spherical shell layers in the single sphere. In this spectrometer, a band-shaped thermal neutron detection medium, which consists of a LiF-ZnS mixed powder scintillator sheet and a wavelength-shifting (WLS) fiber readout, was looped to each sphere at equal angular intervals. Amount of LiF neutron converter is reduced near polar region, where the band-shaped detectors are concentrated, in order to uniform the directional sensitivity. The LiF-ZnS mixed powder has an advantage of extremely high light yield. However, since it is opaque, scintillation photons cannot be collect uniformly. This type of detector shows no characteristic shape in the pulse height spectrum. Subsequently, it is difficult to set the pulse height discrimination level. This issue causes sensitivity fluctuation due to gain instability of photodetectors and/or electric modules. Materials and Methods: In order to solve this problem, we propose to replace the LiF-ZnS mixed powder into a flexible and Transparent RUbber SheeT type $LiCaAlF_6$ (TRUST LiCAF) scintillator. TRUST LiCAF scintillator can show a peak shape corresponding to neutron absorption events in the pulse height spectrum. Results and Discussion: We fabricated the prototype detector with five sensitive layers using TRUST LiCAF scintillator and conducted basic experiments to evaluate the directional uniformity of the sensitivity. Conclusion: The fabricated detector shows excellent directional uniformity of the neutron sensitivity.

Design and Fabrication of CLYC-Based Rotational Modulation Collimator (RMC) System for Gamma-Ray/Neutron Dual-Particle Imager

  • Kim, Hyun Suk;Lee, Jooyub;Choi, Sanghun;Bang, Young-bong;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • 제46권3호
    • /
    • pp.112-119
    • /
    • 2021
  • Background: This work aims to develop a new imaging system based on a pulse shape discrimination-capable Cs2LiYCl6:Ce (CLYC) scintillation detector combined with the rotational modulation collimator (RMC) technique for dual-particle imaging. Materials and Methods: In this study, a CLYC-based RMC system was designed based on Monte Carlo simulations, and a prototype was fabricated. Therein, a rotation control system was developed to rotate the RMC unit precisely, and a graphical user interface-based software was also developed to operate the data acquisition with RMC rotation. The RMC system was developed to allow combining various types of collimator masks and detectors interchangeably, making the imaging system more versatile for various applications and conditions. Results and Discussion: Operational performance of the fabricated system was studied by checking the accuracy and precision of the collimator rotation and obtaining modulation patterns from a gamma-ray source repeatedly. Conclusion: The prototype RMC system showed reliability in its mechanical properties and reproducibility in the acquisition of modulation patterns, and it will be further investigated for its dual-particle imaging capability with various complex radioactive source conditions.

A Fast Neutron Time-of-Flight Spectrometer with High Resolution

  • Cho, Mann
    • Nuclear Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.116-131
    • /
    • 1972
  • Li$^{7}$ (p, n) Be$^{7}$ 원자핵반응에서 Li target의 두께와 입사양자의 에너지를 적절히 선정하므로써 1-n sec 파동 Van de Graaff 가속도로부터 keV 영역에서의 연속중성자spectrum을 발생시키고 92% 농축된 5mm 두께의 $B^{10}$ 판과 4개의 4"$\times$3" NaI (T1) 발광체로 이루어진 속중성자검출기를 이용 속중성자 비행시간법에 의한 중성자spectrometer 를 제작하였다. 장치의 에너지 분해능은 50 keV에서 0.3%보다 양호하며 신호대잡음비도 개량되었다. 이를 이용하여 몇가지 분석된 단일동위원소의 전단면적을 측정하고 R-matrix 전자계산 code로 분석하였다. 각 공명에 따르는 스핀식와 공명인수들을 찾아내었다.

  • PDF

중성자 비행시간법을 이용한 인듐의 공명에너지 동정에 관한 연구 (Neutron Capture Resonance Energy Identification of Indium by Time-of-Flight Method)

  • 이삼열
    • 한국방사선학회논문지
    • /
    • 제6권5호
    • /
    • pp.403-408
    • /
    • 2012
  • 본 연구는 천연 인듐의 중성자폭획 후에 발생된 감마선을 12개의 BGO($Bi_4Ge_3O_{12}$) 섬광검출기로 구성된 검출장치를 이용하여 즉발감마선을 측정하여 중성자공명에 의해서 발생된 감마선을 분석하여 중성자의 에너지 1 ~ 300 eV 영역에 대하여 공명에너지를 분석하였다. 사용되어진 검출장치는 시료에서 발생된 즉발감마선에 대하여 모든 감마선을 측정할 수 있는 기하학적인 구조로 만들어졌다. 중성자원으로는 교토대학의 원자로연구소의 46-MeV 전자선형가속기의 광핵반응에서 발생하는 중성자를 이용하였다. 중성자발생원으로부터 검출기까지의 거리가 $12.7{\pm}0.02m$이므로 광핵반응에서 발생하는 강한 X선의 영향을 고려하여 수 keV영역이하의 중성자에너지에 대하여 중성자공명을 측정하였다. 측정되어진 공명들은 1 eV이상의 에너지 영역에서 거대 공명들을 측정하였고 이들 공명들은 이론에서 알려진 값들과 비교하였다. 본 연구를 통하여 기존에 알려진 거대 공명의 에너지를 확인하였고, 100 eV이상의 에너지 영역에서의 공명에너지들에 대한 평가에 의한 이론값들이 실제로 존재하는 공명임을 실험적으로 확인하였다. 1 keV 이상의 영역에 대하여는 공명이 연속적인 구조를 보이고 있음을 실험적으로 확인했으며 공명에 대하여 통계적인 평가가 있어야함을 알았다. 91.49 eV 공명은 본 연구를 통하여 처음 발견되어진 공명이라 볼 수 있다.

Measurement of Neutron Capture Gamma-ray Spectrum of Natural Gold in the keV Energy Region

  • Lee, Jae-Hong;Lee, Sam-Yol;Lee, Sang-Bock;Lee, Jun-Haeng;Jin, Gye-Hwan
    • 한국방사선학회논문지
    • /
    • 제1권1호
    • /
    • pp.45-49
    • /
    • 2007
  • 동경공업대학교의 3MV 펠레트론가속기를 사용하여 10에서 90keV 영역에 대하여 $^{197}Au$의 중성자포획 스펙트럼을 측정하였다. 중성자 펄스빔은 $^7Li(p,n)^7Be$반응을 통하여 발생되었다. 사용되어진 양성자 빔의 폭은 1.5-ns였다. 금 시료에 입사된 중성자의 에너지 스펙트럼은 $^6Li$-glass 섬광검출기의 중성자 비행시간법을 사용하여 측정하였다. 금 시료의 중성자포획에 의해서 발생된 감마선은 anti-Compton NaI(TI) 검출장비를 사용하여 측정되었다. 본 연구에서는 5개의 중성자 에너지 역영을 선택했고, 각각의 에너지영역에서 얻어진 감마선파고스펙트럼을 표시하였다. 본 연구에서 얻어진 스펙트럼은 처음으로 얻어진 결과이며, 중성자 결합에너지부근에 몇 개의 천이 피크가 보인다.

  • PDF

46-MeV 전자선형가속기의 TOF 방법을 이용한 탄탈의 중성자 공명 에너지 분석에 관한 연구 (A Study on Neutron Resonance Energy of Tantalum by 46-MeV Electron Linac TOF Method)

  • 이삼열
    • 한국방사선학회논문지
    • /
    • 제7권3호
    • /
    • pp.245-249
    • /
    • 2013
  • 천연 탄탈의 중성자포획에 의한 공명에너지를 측정하기 위하여 교토대학의 원자로연구소의 46-MeV 전자선형가속기의 광핵반응에서 발생하는 중성자를 이용하였다. 중성자포획에서 발생되는 즉발감마선을 BGO($Bi_4Ge_3O_{12}$)섬광검출장치로 측정하였다. 검출장치는 탄탈 시료에서 발생되는 즉발감마선을 기하학적으로 모두 측정하도록 만들어져 있으며 측정되어진 전기적 신호를 탄탈의 중성자 공명에너지 동정하는 스펙트럼구성에 사용하였다. 연구에서 사용되어진 중성자의 에너지는 1 ~ 200 eV 영역에 대하여 각각의 공명에너지를 분석하였다. 중성자에너지 측정은 중성자 비행시간법(TOF: Time-of-Flight)을 통하여 측정하였다. 광핵반응을 통한 중성자발생에서는 고에너지영역에서 강한 제동복사선이 발생하므로 수 keV영역 이하 영역의 중성자에너지에 대해서만 중성자공명을 측정하였다. 얻어진 Ta에 대한 중성자 포획 공명에너지 측정결과는 이전의 실험에 의한 측정 결과들 및 ENDF/B-VI와 Mughabghab의 평가된 값들과 비교 및 검토를 하였다. 측정되어진 공명들은 4.28 eV에서 거대 공명들을 측정하였고 그 이상의 에너지 영역의 다른 공명들도 이론에 의해서 계산되어진 값들과 비교하였다. 144.3 eV를 제외한 공명들은 평가값들과 거의 일치하는 경향을 보였다.

1 eV 이하 에너지 영역에서의 180Ta 동위원소의 중성자공명에 대한 연구 (A Study on Neutron Resonance Energy of 180Ta below 1eV Energy)

  • 이삼열
    • 한국방사선학회논문지
    • /
    • 제8권6호
    • /
    • pp.287-292
    • /
    • 2014
  • 본 연구는 자연 속에 미량(존재비: 0.012 %)으로 존재하는 $^{180}Ta$의 중성자포획 공명에 대하여 포획단면적의 계산치와 측정치를 비교하여 분석하였다. 일반적으로 중성자 공명은 Breit-Wigner식으로 정의되며, 식에는 공명에너지를 중심으로 공명의 폭을 결정하는 다양한 인자들로 구성되어 있다. 그러나 $^{180}Ta$의 경우 중성자포획단면적과 공명에 대한 정보가 잘 알려져 있지 않고 실험적으로도 측정되어진 예가 현재까지는 없는 것이 현실이다. 따라서 본 실험에서는 천연 Ta속에 포함되어진 $^{180}Ta$에 의한 중성자 포획에 의해 발생되는 감마선을 관측하여 $^{180}Ta$의 공명을 분석하고 Mughabghab에 의해서 계산되어진 공명인자를 사용하여 1 eV이하의 에너지에 대한 중성자포획단면적을 계산하고 비교분석하였다. 측정을 위해서 교토대학원자로 실험소의 46-MeV 전자선형가속기를 이용하여 중성자 TOF 방법으로, 에너지 영역 0.003 eV에서 10 eV에 걸쳐 측정하였다. 측정을 위해서는 12개의 $Bi_4Ge_3O_{12}(BGO)$섬광체로 구성된 전에너지 흡수검출장치로 $^{180}Ta(n,{\gamma})^{181}Ta$ 반응으로부터 나오는 즉발감마선을 측정하였다.