• Title/Summary/Keyword: Neutron activation

Search Result 248, Processing Time 0.026 seconds

Characterization of Korean Archaeological Artifacts by Neutron Activation Analysis (I). Multivariate Classification of Korean Ancient Coins. (중성자 방사화분석에 의한 한국산 고고학적 유물의 특성화 연구 (I). 다변량 해석법에 의한 고전 (古錢) 의 분류 연구)

  • Chul Lee;Oh Cheun Kwun;Hyung Tae Kang;Ihn Chong Lee;Nak Bae Kim
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.555-566
    • /
    • 1987
  • Fifty ancient Korean coins originated in Yi Dynasty have been determined for 9 elements such as Sn, Fe, As, Ag, Co, Sb, Ir, Ru and Ni by instrumental neutron activation analysis and for 3 elements such as Cu, Pb, and Zn by atomic absorption spectrometry. Bronze coins originated in early days of the dynasty contain as major constituents Cu, Pb and Sn approximately in the ratio 90 : 4 : 3, whereas, those in latter days contain in ratio 7 : 2 : 0. Brass coins which had begun in 17 century contain as major constituents Cu, Zn and Pb approximately in the ratio 7 : 1 : 1. The multivariate data have been analyzed for the relation among elemental contents through the variance-covariance matrix. The data have been further analyzed by a principal component mapping method. As the results training set of 8 class have been chosen, based on the spread of sample points in an eigen vector plot and archaeological data such as age and the office of minting. The training set and test set of samples have finally been analyzed for the assignment to certain classes or outliers through the statistical isolinear multiple component analysis (SIMCA).

  • PDF

Chemical characteristics and sources of fine ambient particulate matter from the third and fourth industrial complex area of Daejeon city, Korea (대전 3, 4 공단지역의 미세분진에 대한 화학적 특성과 오염원 연구)

  • Lim, Jong-Myoung;Lee, Jin-Hong;Chung, Yong-Sam
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.33-40
    • /
    • 2007
  • This study centered on the quantitative analysis of about 27 trace elements including toxic ones using instrumental neutron activation analysis of fine ambient particulate matter in the third and fourth industrial complex area of Daejeon city, Korea. For analytical quality control, the certified reference material (NIST, the National Institute of Standards and Technology, U.S.A., SRM 2783, air particulate on filter media) was used. The errors relative to SRM values of Sb, Mn, V, Mg, Na, K, Ti, Co, Zn, and Sm fell below 5%, while those of Cr, Fe, Ba, Th, Ce, Al, and Cu were less than 10%. From the results of the quantitative analysis, the concentration of toxic metals such as As, Mn, Se, V, and Zn were $3.26{\pm}2.72$, $9.86{\pm}4.71$, $2.18{\pm}1.25$, $4.91{\pm}2.41$, $158{\pm}78ng/m^3$, respectively. And the results of factor analysis indicated that there are no more than six factors of sources of fine ambient particulate with statistical significance in the study area.

Impurity analysis and acid leaching purification of silica minerals (실리카광물의 산침출 정제와 불순물 분석법 연구)

  • Lee, Kil Yong;Yoon, Yoon Yeol;Cho, Soo Young;Chae, Young-Bae
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.516-523
    • /
    • 2007
  • Purification of silica mineral has been investigated by acid leaching of pulverized silica. A series of studies has been carried out on the effect of leaching silica powder as a function of the leaching time at the constant temperature of $80^{\circ}C$ in oxalic acid, aqua regia, and two mixed acids of HF/HCl, $HF/HNO_3$. The impurities of silica and leachantes were measured by neutron activation analysis (NAA), inductively coupled plasma atomic emission spectrometry (ICP-AES), atomic absorption spectrometry, x-ray fluorescence (XRF) method and wet analysis (WA). Certain metals, such as sodium, calcium, iron, aluminium and titanium, have been found in concentrations of hundreds or even thousands of mg/kg. Comparison of purification processes of silica and analytical methods of impurities in the silica was conducted in this study.

Experimental Study on the Determination of Absorbed dose Index (흡수선량지수결정(吸收線量指數決定)에 관한 실험적(實驗的) 연구(硏究))

  • Jun, Jae-Shik;Rho, Chae-Shik;Ro, Seung-Gy;Ha, Chung-Woo;Yoo, Young-Soo;Lee, Hyun-Duk
    • Journal of Radiation Protection and Research
    • /
    • v.7 no.1
    • /
    • pp.34-48
    • /
    • 1982
  • The prime purpose of this study is to realize an index quantity, absorbed dose index, defined by the ICRU for the characterization of ambient radiation level at any location for the purpose of radiation protection. The experiment has been designed to be carried out in two phases, namely, preliminary and main experiment. In the primary study a 30cm diameter sphere of polyethylene was used, while in the main experiment that of tissue equivalent material was fabricated and used. Both experiments were performed in the gamma-ray fields of $^{137}Cs\;and\;^{60}Co$, and in a neutron beam of thermal column of the TRIGA MARK-II research reactor. In the measurement of gamma-ray absorbed dose TLD-700 $(^{7}LiF)$ chips were used, and for the neutron dose both Au activation foils and TLD chips (TLD-600 $(^{6}LiF)$ and TLD-700 for the discrimination of gamma-ray contribution) were used. Theoretical assessment of the absorbed dose in the sphere phantom has been carried out in accordance with the Ehrlich's idea that deduced on the basis of Burlin's cavity theory in the case of gamma-ray irradiation. For the analysis of neutron dose fluence-KERMA rate conversion method was used. The explanation on the dose assessment is given in detail. Results obtained were numerically and statistically analyzed and the depth dose distributions are presented in the graphic forms with normalized values. In the concluding remarks, the possibility and difficulty of realizing the index quantity, including questions and problems to be solved are mentioned.

  • PDF

The Iodine Content in Common Korean Foods (한국인의 상용식품내 요오드 함량)

  • 문수재
    • Journal of Nutrition and Health
    • /
    • v.31 no.2
    • /
    • pp.206-212
    • /
    • 1998
  • This study was undertaken to analyze the iodine content in commonly donsumed Korean foods. Food samples were purchased from 3 randomly selected markets. The iodine contents in foods were determined by nuetron activation analysis (NAA). All irradiation of food samples were done at a pnueumatic transfer system (thermal nuetron flux : 1 $\times$1013n/$\textrm{cm}^2$.s) of the TRIGA MarkIII research reactor in the Korea Atomic Energy Research Institute . The results indicated that the iodine content was high in seaweeds, fishes, and iodine-enriched eggs in that order and very low in grain, beans , fruits and vegetables. Edible seaweeds contained iodine levels of between 13,700 and 1,790, 600$\mu\textrm{g}$/kg. Levels of iodine in fishes and shellfishes were between 478 and 2, 840$\mu\textrm{g}$/kg. Ordinary eggs contained 314$\mu\textrm{g}$/kg iodine, but iodine -enriched eggs contained 1,869$\mu\textrm{g}$/kg. The average concentration of iodine in milk was 207$\mu\textrm{g}$/kg. There was seasonal variation in the iodine content of milk , levels were highest in winter milk(230$\mu\textrm{g}$/kg) and lowest in summer milk(180$\mu\textrm{g}$/kg).The idodine contents of most vegetables and fruits were below 10$\mu\textrm{g}$/kg. The iodine contents of most vegetables and fruits were below 10$\mu\textrm{g}$/kg. From high to low , the sequence of foods with high iodine content in one serving was as follows ; sea tangle , sea mustard, iodine-enriched eggs, fish , laver and milk. This study may provide basic data on the iodine content of foods consumed by Korean which have not yet been analyzed .

  • PDF

Study of Selenium Compound in Favorite Korean Foodstuffs (한국 식품중의 Se 화합물의 함량에 관한 연구)

  • Chun, Sea-Yeol
    • Korean Journal of Food Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.55-64
    • /
    • 1973
  • Garlic and traditional fovarite foodstuffs of plant origin have been analyed for selenium and sulfur containing amino acid content selenium compound were assayed using a $^{77m}Se$ neutron activation analysis, cystine and methionine determination by paper and thin-layer chromatography. The results obtained indicate that the content of selenium and sulfur containing amino acid are highest in garlic. The results also show that the selenium is a more abundant in particular speies such as garlics produced in Tan Yang and Wei Sung. The effect of Korean garlic and favorite typically found in the Korean diet has also been studied. Some vegetables known to contain a relatively high level of sulfur and selenium (garlic and onion) do loss significent quantities of selenium as a result of cooking.

  • PDF

Comparative Analysis of Elemental Components in Airborne Particulate Matter by k0-NAA Methods (대기분진의 원소분석에 대한 k0-NAA법의 비교)

  • Chung, Yong-Sam;Moon, Jong-Hwa;Cho, Hyun-Je;Kim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.51-58
    • /
    • 2005
  • A comparison of the analytical data obtained by three $k_0$-NAA software programs was carried out using both the airborne particulate matter collected from an urban site and the certified reference materials of the air filter and urban dust to evaluate the performance of the analysis. The individual $k_0$-NAA standardization methods of three countries, Korea, China and Vietnam which had been modified from the well established $k_0$-program were used for the comparative analysis. The measured concentrations of 30 elements from the two kinds of air samples based on this software were in agreement with each other within about 20% analytical error except for a few elements. By contrast, the results of China and Vietnam were moderately higher than that of Korea due to a systematic error associated with the detection efficiency, gamma peak analysis and geometric effect.

Raw Material and Provenance of Chosen-Tongbo (I) (조선통보의 주조원료와 산지 연구(I))

  • Kang, Hyung Tae;Kim, Gyu Ho;Huh, Woo Young;Hirao, Yoshimitsu
    • Journal of Conservation Science
    • /
    • v.16 s.16
    • /
    • pp.15-20
    • /
    • 2004
  • Two pieces of choson-Tongue(朝鮮通寶) minted at 1423 A.D. were analyzed by atomic absorption spectroscopy and neutron activation analysis. The measurement of lead isotope ratios was also carried out in order to predict the provenance of raw materials used for minting. The Chosen-Tongue was minted as bronze having the chemical compositions of $Cu\;90\%,\;Pb\;3\~4\%,\;Sn\;2\~3\%$, which were different from the typical composition of Chinese and Japanese coins. The results of lead isotope ratios showed that the provenance of raw materials used for minting had a possibility to be originated from South China. And application of statistical linear discriminant analysis (SLDA) to the provenance of lead used for minting of Chosen-Tongue was confirmed.

  • PDF

Trace Elements Characterization of PM10 in Seoul Area (서울지역의 PM10 중 미량원소의 특성 평가)

  • 신은상;최민규;영선우;정용삼
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.363-372
    • /
    • 2002
  • PM$_{10}$ aerosols were collected using low volume air sampler every month intervals from September 1992 to August 1991 in Seoul. These samples were analyzed for 20 trace elements (Al, As, Ba, Br, Ca, Cl, Co, Cr, Fe, K, Mn, Na, Ni, Pb, Sc, Se, Si, Ti, V and Zn) by INAA (instrumental neutron activation analysis), XRF (x-ray fuorescence spectrometer), and ICP (inductively coupled plasma). PM$_{10}$ mass concentrations higher than 70 $\mu$g/m$^3$ were 32% of 60 samples and had significantly higher concentrations in spring and winter than in summer and fall (p-value<0.001). The elements of As, Br, Cl, Ni, Pb, Se, V, and Zn are enriched by factors of 20 to 2,000 relative to their natural abundance in crustal soil. To further identify common sources of pollution-related trace elements, factor analysis was applied to the trace elements concentration data. Major sources that contribute to the atmospheric loading of these elements were found to include fossil fuel combustion, automobile and waste incineration (33.2%), metal processing industry (18.2%), and soil(29.8%).8%).

Development of Moving Alternating Magnetic Filter Using Permanent Magnet for Removal of Radioactive Corrosion Product from Nuclear Power Plant

  • M. C. Song;Kim, S. I.;Lee, K. J.
    • Nuclear Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.494-501
    • /
    • 2002
  • Radioactive Corrosion Products (CRUD) which are generated by the neutron activation of general corrosion products at the nuclear power plant are the major source of occupational radiation exposure. Most of the CRUD has a characteristic of showing strong ferrimagnetisms. Along with the new development and production of permanent magnet (rare earth magnet) which generates much stronger magnetic field than the conventional magnet, new type of magnetic filter that can separate CRUD efficiently and eventually reduce radiation exposure of personnel at nuclear power plant is suggested. This separator consists of inner and outer magnet assemblies, coolant channel and container surrounding the outer magnet assembly. The rotational motion of the inner and outer permanent magnet assemblies surrounding the coolant channel by driving motor system produces moving alternating magnetic fields in the coolant channel. The CRUD can be separated from the coolant by the moving alternating magnetic field. This study describes the results of preliminary experiment performed with the different flow rates of coolant and rotation velocities of magnet assemblies. This new magnetic filter shows better performance results of filtering the magnetite at coolant (water). How rates, rotating velocities of magnet assemblies and particle sizes turn out to be very important design parameters.