Calibration of digital wide-range neutron power measurement channel for open-pool type research reactor

  • Joo, Sungmoon;Lee, Jong Bok;Seo, Sang Mun
    • Nuclear Engineering and Technology
    • /
    • 제50권1호
    • /
    • pp.203-210
    • /
    • 2018
  • As the modernization of the nuclear instrumentation system progresses, research reactors have adopted digital wide-range neutron power measurement (DWRNPM) systems. These systems typically monitor the neutron flux across a range of over 10 decades. Because neutron detectors only measure the local neutron flux at their position, the local neutron flux must be converted to total reactor power through calibration, which involves mapping the local neutron flux level to a reference reactor power. Conventionally, the neutron power range is divided into smaller subranges because the neutron detector signal characteristics and the reference reactor power estimation methods are different for each subrange. Therefore, many factors should be considered when preparing the calibration procedure for DWRNPM channels. The main purpose of this work is to serve as a reference for performing the calibration of DWRNPM systems in research reactors. This work provides a comprehensive overview of the calibration of DWRNPM channels by describing the configuration of the DWRNPM system and by summarizing the theories of operation and the reference power estimation methods with their associated calibration procedure. The calibration procedure was actually performed during the commissioning of an open-pool type research reactor, and the results and experience are documented herein.

CHARACTERISTICS OF THE KAERI NEUTRON REFERENCE FIELDS FOR THE CALIBRATION OF NEUTRON MONITORING INSTRUMENTS

  • Kim, Bong-Hwan;Kim, Jang-Lyul;Chang, Si-Young;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.243-248
    • /
    • 2001
  • Neutron reference fields of Korea Atomic Energy Research Institute (KAERI) for calibrating neutron measuring devices to be used in radiation workplace monitoring consist of two kinds of neutron spectra, the direct and the scattered neutron fields, which are produced by using radionuclide neutron sources, 252Cf and 241AmBe sources. Necessary parameters for calibration such as the anisotropy factor of each neutron source and the room-scattered fraction of some neutron surveymeters in the KAERI calibration facility were determined by calculation or measurement. Spectral measurement of scattered neutron fields were performed at each reference calibration point using a Bonner Multi-sphere Spectrometer (BMS) and the dosimetric quantities for calibration also estimated from the neutron energy spectra which were unfolded using the BUNKI code.

  • PDF

A REVIEW OF NEUTRON SCATTERING CORRECTION FOR THE CALIBRATION OF NEUTRON SURVEY METERS USING THE SHADOW CONE METHOD

  • KIM, SANG IN;KIM, BONG HWAN;KIM, JANG LYUL;LEE, JUNG IL
    • Nuclear Engineering and Technology
    • /
    • 제47권7호
    • /
    • pp.939-944
    • /
    • 2015
  • The calibration methods of neutron-measuring devices such as the neutron survey meter have advantages and disadvantages. To compare the calibration factors obtained by the shadow cone method and semi-empirical method, 10 neutron survey meters of five different types were used in this study. This experiment was performed at the Korea Atomic Energy Research Institute (KAERI; Daejeon, South Korea), and the calibration neutron fields were constructed using a $^{252}Californium$ ($^{252}Cf$) neutron source, which was positioned in the center of the neutron irradiation room. The neutron spectra of the calibration neutron fields were measured by a europium-activated lithium iodide scintillator in combination with KAERI's Bonner sphere system. When the shadow cone method was used, 10 single moderator-based survey meters exhibited a smaller calibration factor by as much as 3.1-9.3% than that of the semi-empirical method. This finding indicates that neutron survey meters underestimated the scattered neutrons and attenuated neutrons (i.e., the total scatter corrections). This underestimation of the calibration factor was attributed to the fact that single moderator-based survey meters have an under-ambient dose equivalent response in the thermal or thermal-dominant neutron field. As a result, when the shadow cone method is used for a single moderator-based survey meter, an additional correction and the International Organization for Standardization standard 8529-2 for room-scattered neutrons should be considered.

Development of the Graphite-Moderated Neutron Calibration Fields Using 241Am-Be Sources in JAEA-FRS

  • Nishino, Sho;Tanimura, Yoshihiko;Ebata, Yoshiaki;Yoshizawa, Michio
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.211-215
    • /
    • 2016
  • Background: The moderated neutron calibration fields using $^{241}Am$-Be sources and a graphite moderator have been constructed at the Facility of Radiation Standard (FRS) in the Japan Atomic Energy Agency (JAEA). Materials and Methods: The neutron spectra of the fields were evaluated by the Monte-Carlo calculations and measurements using the Bonner Multi-sphere Spectrometer. Results and Discussion: The fields have continuous neutron spectra from several MeV to thermal neutron energy, with fluence-averaged energies of 0.84 MeV and 0.60 MeV. Reference values of fluence rates and ambient/personal dose equivalent rates were determined from neutron spectra by measurements. Conclusion: Currently, the fields are available for calibration or performance test of neutron measuring instruments.

Determination of Microdosimetric Quantities of Several Neutron Calibration Fields at KAERI

  • Kim, B.H.;Kim, J.S.;Kim, J.L.;Chang, S.Y.;Cho, G.;McDonald, J.C.
    • Journal of Radiation Protection and Research
    • /
    • 제28권4호
    • /
    • pp.327-335
    • /
    • 2003
  • The commercially available neutron survey meter, the REM500, which uses a tissue equivalent proportional counter (TEPC) and the self-constructed TEPC were used to determine the microdosimetric quantities of several neutron calibration fields at Korea Atomic Energy Research Institute (KAERI). Microdosimetric spectra, absorbed dose, dose equivalent as well as quality factor were derived and compared with several neutron fields which were produced by using the shadow objects to make neutron scattered and being used as a kind of realistic neutron calibration fields at KAERI. The response of REM500 as a function of mean energy was evaluated with these neutron fields using the counts measured and the predetermined reference value. The response of the self-made TEPC and the REM500 was compared using one of the neutron calibration filelds of a $^{252}Cf$ source. The reference quantities of scattered neutron calibration fields were determined using a Bonner Sphere (BS). The value of frequency-mean lineal energy, dose-mean lineal energy and quality factor of two $^{252}Cf$ sources (unmoderated and $D_2O$ moderated) were determined to check the differences in the reference neutron fields between KAERI and Pacific Northwest National Laboratory (PNNL, USA) and the results were in good agreement within 1%. It means that there is no big difference in dosimetric quantifies of neutron calibration fields of two laboratories.

Energy Calibration for Neutron Capture Resonance of Natural Sm by Using 46-MeV Electron Linear Accelerator

  • Lee, Jae-Hong;Lee, Sam-Yol
    • 한국방사선학회논문지
    • /
    • 제1권2호
    • /
    • pp.31-35
    • /
    • 2007
  • Energy calibration is important to identify accurate neutron capture resonance energy in the neutron TOF (Time-of-Flight) experiment. In present study, the accurate neutron capture resonance energies of natural Sm were measured by using a 46-MeV electron linear accelerator (linac) at the Research Reactor Institute, Kyoto University(KURRI). The BGO spectrometer were adopted for measurement the prompt capture gamma-ray of the sample. To obtain energy calibration curve, resonance energy of a gold sample used as standard resonance energy Mughabghab's data (From neutron resonance parameters data). Previous data (by Mughabghab) of natural Sm sample have been compared with the present result.

  • PDF

한국원자력연구소 중성자교정실에 대한 중성자산란보정인자 결정연구 (Comparison Study of Experimental Neutron Room Scattering Corrections with Theoretical Corrections in RCL's Calibration Facility at KAERI)

  • 윤석철;장시영;김종수;김장렬;김봉환
    • Journal of Radiation Protection and Research
    • /
    • 제22권1호
    • /
    • pp.29-33
    • /
    • 1997
  • 중성자교정실내에서 $D_2O$ 감속 $^{252}Cf$중성자선원을 사용하여 계측기를 교정할 때는 그 계측기에 대한 교정실산란보정 인자를 미리 결정하여야 한다. 이러한 교정실산란보정인자는 계측기의 종류, 교정거리, 교정실형태에 따라 다르게 결정된다. 본 연구에서는 한국원자력연구소에서 운영하는 2차 표준중성자교정실에서 한가지의 열형광선량계와 2가지의 구형검출기에 대한 교정실산란보정인자를 실험적으로 결정하였고 본소의 2차 표준중성자교정실조건에 의하여 이론적으로 예측한 값과 비교하였다. 비교한 결과 실험하여 얻어진 상기의 3가지 계측기에 대한 교정실산란보정인자가 이론적으로 예측한 결과와 최대 약 10% 이내에서 일치하였다.

  • PDF

Method of the known cross sections for calibration of the fast neutron spectrometer with a single-crystal stilbene based detector

  • I.V. Urupa;E.V. Ryabeva;R.F. Ibragimov;V.D. Sapozhnikov
    • Nuclear Engineering and Technology
    • /
    • 제56권9호
    • /
    • pp.3602-3607
    • /
    • 2024
  • The present work is devoted to implementation of the stilbene-based neutron spectrometer energy calibration method. The results of experiments with portable neutron generators and 238PuBe source and scattering materials with known cross sections are used for this method. It is shown that the submitted method makes it possible to carry out fast neutron spectrometry in the energy range from 1 to 15 MeV with the uncertainty of the unfolded neutron energy no more than 200 keV. Neutron spectra unfolding was carried out based on the measured spectra and a Geant4 simulated response matrix. Unfolded spectra were compared with the literature data and reference spectra.

Neutron Calibration Field of a Bare 252Cf Source in Vietnam

  • Le, Thiem Ngoc;Tran, Hoai-Nam;Nguyen, Khai Tuan;Trinh, Giap Van
    • Nuclear Engineering and Technology
    • /
    • 제49권1호
    • /
    • pp.277-284
    • /
    • 2017
  • This paper presents the establishment and characterization of a neutron calibration field using a bare $^{252}Cf$ source of low neutron source strength in Vietnam. The characterization of the field in terms of neutron flux spectra and neutron ambient dose equivalent rates were performed by Monte Carlo simulations using the MCNP5 code. The anisotropy effect of the source was also investigated. The neutron ambient dose equivalent rates at three reference distances of 75, 125, and 150 cm from the source were calculated and compared with the measurements using the Aloka TPS-451C neutron survey meters. The discrepancy between the calculated and measured values is found to be about 10%. To separate the scattered and the direct components from the total neutron flux spectra, an in-house shadow cone of 10% borated polyethylene was used. The shielding efficiency of the shadow cone was estimated using the MCNP5 code. The results confirmed that the shielding efficiency of the shadow cone is acceptable.

방사성 중성자선원에 의한 방사선방어측정기의 교정을 위한 표준 중성자 조사장치 연구 (Standard Neutron Irradiation Facility for Calibration of Radiation Protection Instruments by Radioactive Neutron Sources)

  • 최길웅;이경주;황선태
    • Journal of Radiation Protection and Research
    • /
    • 제14권1호
    • /
    • pp.66-70
    • /
    • 1989
  • 방사성 중성자선원은 일상적 시험에 있어 표준 중성자 방사선장을 형성하는데 적합하다. 방사선 방어상의 목적으로 사용되는 중성자 측정기기의 교정을 위한 기준 방사선이 ISO TC-85에서 제의되었다. 한국표준연구소 방사선연구실에는 ISO TC-85의 추천사항에 준하여 개인용 중성자 선량계를 교정하기 위하여 $^{252}Cf$$^{241}Am-Be$ 선원을 이용한 표준조사시설을 설립하였다. 본 연구에서는 중성자 산란과 선원 비등방성에 연관된 교정상의 보정인자들을 실험에 의하여 결정하였다.

  • PDF