• 제목/요약/키워드: Neutron Beam

검색결과 179건 처리시간 0.023초

Characterization of a Neutron Beam Following Reconfiguration of the Neutron Radiography Reactor (NRAD) Core and Addition of New Fuel Elements

  • Craft, Aaron E.;Hilton, Bruce A.;Papaioannou, Glen C.
    • Nuclear Engineering and Technology
    • /
    • 제48권1호
    • /
    • pp.200-210
    • /
    • 2016
  • The neutron radiography reactor (NRAD) is a 250 kW Mark-II Training, Research, Isotopes, General Atomics (TRIGA) reactor at Idaho National Laboratory, Idaho Falls, ID, USA. The East Radiography Station (ERS) is one of two neutron beams at the NRAD used for neutron radiography, which sits beneath a large hot cell and is primarily used for neutron radiography of highly radioactive objects. Additional fuel elements were added to the NRAD core in 2013 to increase the excess reactivity of the reactor, and may have changed some characteristics of the neutron beamline. This report discusses characterization of the neutron beamline following the addition of fuel to the NRAD. This work includes determination of the facility category according to the American Society for Testing and Materials (ASTM) standards, and also uses an array of gold foils to determine the neutron beam flux and evaluate the neutron beam profile. The NRAD ERS neutron beam is a Category I neutron radiography facility, the highest possible quality level according to the ASTM. Gold foil activation experiments show that the average neutron flux with length-to-diameter ratio (L/D) = 125 is $5.96{\times}10^6n/cm^2/s$ with a $2{\sigma}$ standard error of $2.90{\times}10^5n/cm^2/s$. The neutron beam profile can be considered flat for qualitative neutron radiographic evaluation purposes. However, the neutron beam profile should be taken into account for quantitative evaluation.

중성자 발생용 구형 집속빔 핵융합 장치의 방전현상 연구 (A Study on Discharge Phenomenon of Spherically Convergent Beam Fusion Device for Neutron Generation)

  • 박정호;주흥진;고광철
    • 한국전기전자재료학회논문지
    • /
    • 제20권5호
    • /
    • pp.467-470
    • /
    • 2007
  • Application field of neutron beam is very broad including industry, medicine and science. But the research and development and use of neutron beam is restricted within in narrow limits in this country, because neutron beam facility is insufficient - a big research facility of nuclear reactor(HANARO) and some small industrial facilities which use radioisotope neutron source are available. This paper compare and investigate the results of experiment and numerical analysis of the discharge in the spherically convergent beam fusion device which were expected as a portable neutron source. The spherically convergent beam fusion device will offer stability in neutron production, possibility of movement for convenience, low construction cost and higher neutron flux than radioisotope neutron source. The star mode discharge which efficiently generate neutron, were observed at both results.

Epithermal Neutron Flux Enhancement Using SMA in Designing a Cf-Based Neutron Beam for BNCT

  • Kim, Do-Heon;Kim, Jong-Kyung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.937-942
    • /
    • 1995
  • Great interest has prompted Boron Neutron Capture Therapy (BNCT) as a new treatment for brain tumors. The use of $^{252}$Cf as a neutron source for BNn makes the in-hospital treatments of tumors to be possible. Newly proposed subcritical multiplying assemblies (SMA) are explored to improve relatively tow neutron fluxes of the source and construct the feasibilities of $^{252}$Cf as a neutron source. The MCNP code has been used to evaluate the effective multiplication factor of the entire system and the intensities and percentages of epithermal neutron flux at the patient-end surface of the system. The neutron beam using SMA shows the epithermal neutron flux enhancement of about 13 times as large as the beam without using SMA. It is expected that the neutron beam proposed in this research will be more effective for treatment of tumors due to the increased therapeutic neutron fluxes.

  • PDF

An Epithermal Neutron Beam Design for BNCT Using $^2H(d,n)^3He$ Reaction

  • Han, Chi-Young;Kim, Jong-Kyung;Chung, Kyu-Sun
    • Nuclear Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.512-521
    • /
    • 1999
  • A feasibility study was performed to design an epithermal neutron beam for BNCT using the neutron of 2.45 MeV on the average produced from $^2H(d,n)^3$He reaction induced by plasma focus in the z-pinch instead of the conventional accelerator-based $^3H(d, n)^4$He neutron generator. Flux and spectrum were analyzed to use these neutrons as the neutron source for BNCT. Neutronic characteristics of several candidate materials in this neutron source were investigated Using MCNP Code, and $^7LiF$ ; 40%Al + 60%$AIF_3$, and Pb Were determined as moderator, filter, and reflector in an epithermal neutron beam design for BNCT, respectively. The skin-skull-brain ellipsoidal phantom, which consists of homogeneous regions of skin-, bone-, or brain-equivalent material, was used in order to assess the dosimetric effect in brain. An epithermal neutron beam design for BNCT was proposed by the repeated work with MCNP runs, and the dosimetric properties (AD, AR, ADDR, and Dose Components) calculated within the phantom showed that the neutron beam designed in this work is effective in tumor therapy. If the neutron source flux is high enough using the z-pinch plasma, BNCT using the neutron source produced from $^2H(d,n)^3$He reaction will be very feasible.

  • PDF

Measurement of the applicability of various experimental materials in a medically relevant reactor neutron source part two: Study of H3BO3 and B-DTPA under neutron irradiation

  • Ezddin Hutli;Peter Zagyvai
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2419-2431
    • /
    • 2023
  • Experiments related to Boron Neutron Capture Therapy (BNCT) accomplished at the Institute of Nuclear Techniques (INT), Budapest University of Technology and Economics (TUB) are presented. Relevant investigations are required before designing BNCT for vivo applications. Samples of relevant boron compounds (H3BO3, BDTPA) usually employed in BNCT were investigated with neutron beam. Channel #5 in the research reactor (100 kW) of INT-TUB provides the neutron beam. Boron samples are mounted on a carrier for neutron irradiation. The particle attenuation of several carrier materials was investigated, and the one with the lowest attenuation was selected. The effects of boron compound type, mass, and compound phase state were also investigated. To detect the emitted charged particles, a traditional ZnS(Ag) detector was employed. The neutron beam's interaction with the detector-detecting layer is investigated. Graphite (as a moderator) was employed to change the neutron beam's characteristics. The fast neutron beam was also thermalized by placing a portable fast neutron source in a paraffin container and irradiating the H3BO3. The obtained results suggest that the direct measurement approach appears to be insufficiently sensitive for determining the radiation dose committed by the Alpha particles from the 10B (n,α) reaction. As a result, a new approach must be used.

속중성자선의 선량분포에 관한 연구 (Fast Neutron Beam Dosimetry)

  • 이효남;지영훈;지광수;이동한
    • 대한방사선치료학회지
    • /
    • 제9권1호
    • /
    • pp.71-81
    • /
    • 1997
  • I. Objective and Importance of the Project We have been using MC-50 cyclotron and NT-50 neutron therapy machine for treating cancer patients since 1986 at Korea Cancer Center Hospital. It is mandatory to measure accurately the dose distribution and the total absorbed dose of fast neutron for putting it to the clinical use. At present the methods of measurement of fast neutron are proposed largely by American Associations of Physicists in Medicine (Task Group 18), European Clinical Neutron Dosimetry Group, and International Commission on Radiation Units and Measurements. The complexity of measurement, however, induce the methodological differences between them. In our study, therefore, we tried to establish a unique technique of measurement by means of measuring the emitted doses and the dose distribution of fast neutron beam from neutron therapy machine, and to invent a standard method of measurement adequate to our situation. II. Scope and Contents of the Project For establishing a unique technique of measurement and inventing a standard method of measurement of fast neutron beam, 1. to grasp the physical characteristics of neutron therapy machine 2. to study the principles for measrement of fast neutron beam 3. to get the dose distribution (dose rate, percent-depth dose, flatness etc) throught the actual measurement 4. to compare our data with those being cited world-widely.

  • PDF

Design, construction, and characterization of a Prompt Gamma Neutron Activation Analysis (PGNAA) system at Isfahan MNSR

  • M.H. Choopan Dastjerdi;J. Mokhtari;M. Toghyani
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4329-4334
    • /
    • 2023
  • In this research, a prompt gamma neutron activation analysis (PGNAA) system is designed and constructed based on the use of a low power research reactor. For this purpose, despite the fact that this reactor did not include beam tubes, a thermal neutron beam line is installed inside the reactor tank. The extraction of the beam line from inside the tank made it possible to provide the neutron flux from the order of 106 n.cm-2.s-1. Also, because the beam line is installed in a tangential position to the reactor core, its gamma level has been minimized. Also, a suitable radiation shield is considered for the detector to minimize the background radiation and prevent radiation damage to the detector. Calculations and measurements are done in order to characterize this system, as well as spectrometry of several samples. The results of evaluations and experiments show that this system is suitable for performing PGNAA.

Neutron 빔조사 담배 및 벼식물체의 특성 (Characteristics of Tobacco and Rice Plants Irradiated with Neutron Beam)

  • 채종서;김재홍;양태건;류재일;이효연;양덕춘;배창휴
    • 한국자원식물학회지
    • /
    • 제18권3호
    • /
    • pp.359-366
    • /
    • 2005
  • 재배종담배(Nicotiana tabacum L. cv.), 야생종담배 (N. plumbaginifolia)와 벼종자(Orya sativa L, cv.)에 neutron빔을 각각 조사(irradiation)하여 발아, 식물체의 생장과 DNA의 변이에 미치는 영향을 검토하였다. 담배종자와 벼종자에 90, 180, 270, 360, 450, 540 Gy까지 조사로 발아율은 크게 감소하지 않았고, 생장에 있어 유의적인 차이는 없었다. 그러나 담배식물체에서 총 200개체 중 71개체(약 $36\%$)가 잎에서 형태 이상을 나타내었다. 또한 줄기색 변이체, 엽색변이체, 화형변이체를 유도하였다. 이 결과는 neutron빔이 유용한 돌연변이원으로서 가능성이 있음을 시사해 준다. Neutron빔을 조사한 후 생장한 담배식물체의 잎에 대하여 총 34개의 primer를 이용하여 RAPD 분석한 결과 20개의 primer에서 총 104개의 DNA 단편이 증폭되었고, 중성자 빔조사처리구에서만 출현하는 DNA 단편은 나타나지 않았다.

Effect of high-energy neutron source on predicting the proton beam current in the ADS design

  • Zheng, Youqi;Li, Xunzhao;Wu, Hongchun
    • Nuclear Engineering and Technology
    • /
    • 제49권8호
    • /
    • pp.1600-1609
    • /
    • 2017
  • The accelerator-driven subcritical system (ADS) is driven by a neutron source from spallation reactions introduced by the injected proton beam. Part of the neutron source has energy as high as a few hundred MeV to a few GeV. The effects of high-energy source neutrons ($E_n$ > 20 MeV) are usually approximated by energy cut-off treatment in practical core calculations, which can overestimate the predicted proton beam current in the ADS design. This article intends to quantize this effect and propose a way to solve this problem. To evaluate the effects of high-energy neutrons in the subcritical core, two models are established aiming to cover the features of current experimental facilities and industrial-scale ADS in the future. The results show that high-energy neutrons with $E_n$ > 20 MeV are of small fraction (2.6%) in the neutron source, but their contribution to the source efficiency is about 23% for the large scale ADS. Based on this, a neutron source efficiency correction factor is proposed. Tests show that the new correction method works well in the ADS calculation. This method can effectively improve the accuracy of the prediction of the proton beam current.

Beam Characteristics of Polychromatic Diffracted Neutrons Used for Prompt Gamma Activation Analysis

  • S. H. Byun;G. M. Sun;Park, H. D.
    • Nuclear Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.30-41
    • /
    • 2002
  • The neutron beam is fully characterized for the prompt gamma activation analysis facility at Hanaro in the Korea Atomic Energy Research Institute(KAERI). The facility uses thermal neutrons which are diffracted vertically from a horizontal beam port by a set of pyrolytic graphite(PG) crystals positioned at the Bragg angle of 45" Neutron spectra, neutron flux and Cd-ratio are determined for the three extraction modes of diffracted beam by means of the theoretical and experimental efforts. To obtain theoretical result, the reflectivity of pyrolytic graphite is calculated in the diffraction model for mosaic crystal and the angular divergence after diffraction by mosaic crystal is estimated from Monte Carlo simulation. The time-of-flight spectrometer and gold activation wire are used for measuring the neutron spectra. Both the calculated and measured spectra have proven that the unique feature of polychromatic beam obtained by PG crystals are useful for PGAA. The thermal neutron flux of 7.9$\times$107 n/cm$^2$s and the Cd-ratio of 266 for gold have been achieved at the sample position while the reactor operates at 24 MW The uniformity of beam flux is 12% in the central 1$\times$1 cm$^2$ area. Finally, the beam is briefly characterized by the effective velocity and temperature which are determined by measuring the prompt Y-ray spectra for thin and thick boron samples.ples.