• Title/Summary/Keyword: Neutral loss

Search Result 193, Processing Time 0.022 seconds

Quantitative Analysis of Acylcarnitines and Amino Acids Using ESI-MS/MS (ESI-MS/MS를 이용한 아실카르니틴과 아미노산의 정량분석)

  • Kim, Hohyun;Han, Sang-Beom;Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.384-391
    • /
    • 2001
  • In this study, a new quantitative analytical method has been developed for the rapid determination of acylcarnitines and amino acids in human blood using electrospray ionization / tandem mass spectrometry (ESI-MS/MS). Acylarmitines and amino acids were analyzed by tandem mass spectrometry after conversion to their butylesters through treatment with 3N butanolic hydrogen chloride. Acylcrnitines were analyzed using precursor 85 ion scan and alanine, valine, leucine/isoleucine, methionine, phenylalanine, tyrosine, aspartic acid and glutamic acid were analyzed using neutral loss 102 scan, ornitine and citrulline were analyzed neutral loss 119 scan, glycine was analyzed using neutral loss 56 scan, arginine was analyzed using neutral loss 161 scan and argininosuccinic acid was analyzed product ion 459 scan. This method reduced sample preparation time compared to that with conventional amino acid analyzer and liquid chromatography, with high sensitivity and good reproducibility.

  • PDF

Neutral Deinking of Old Newsprints Contaminated with Flexo Ink -Evaluation of the Deinking Efficiency of Two Neutral Deinking Agents- (플렉소 잉크가 포함된 신문고지의 중성 탈묵 -중성 탈묵제의 효율 평가-)

  • Lee, Hak-Lae;Ryu, Hoon
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.1
    • /
    • pp.8-15
    • /
    • 2001
  • Presence of small amount of old newsprints printed with waterbased flexographic inks leads to a significant loss brightness of the deinked pulp by flotation process. Recently there has been an increased interest in employing neutral deinking processes to solve the problems associated with waterbased flexo ink. A comparative experimental study was performed to evaluate the efficiency of neutral deinking and conventional alkaline deinking for ONP furnishes contaminated with flexo ink. It was shown that neutral deinking provides significant improvements in brightness, yield and freeness as compared with alkaline deinking. Flotation efficiency was different depending upon the type of surfactants used in neutral deinking. The result of this study showed that alcohol type surfactant is superior to fatty acid type surfactant in neutral deinking efficiency.

  • PDF

The Washing Finish of Blue Jeans(I) - the comparison of neutral cellulase, acid cellulase, stone, and stone-neutral cellulase washings - (청바지의 세탁가공에 관한 연구(I) -세탁가공의 종류를 중심으로-)

  • 신혜원;유효선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.2
    • /
    • pp.471-481
    • /
    • 1997
  • Denims were treated with neutral cellulase, acid cellulase, stone, and stone-neutral cellulase respectively at different cellulase concentrations varying treatment times in rotary washer. The effect of washing on denim was estimated by the changes in weight, color, back staining, tear strength, flex stiffness, and surface characteristics. Also the comparison of neutral cellulase, acid cellulase, stone, and stone-neutral cellulase washings was studied. Washing removes surface fibers and provides weight loss, color difference, back staining, and a decrease in tear strength and in flex stiffness. Stone-neutral cellulase washing and acid cellulase washing have a larger washing effect than neutral cellulase washing and stone washing.

  • PDF

Partial O-state Clamping PWM Method for Three-Level NPC Inverter with a SiC Clamp Diode

  • Ku, Nam-Joon;Kim, Rae-Young;Hyun, Dong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1066-1074
    • /
    • 2015
  • This paper presents the reverse recovery characteristic according to the change of switching states when Si diode and SiC diode are used as clamp diode and proposes a method to minimize the switching loss containing the reverse recovery loss in the neutral-point-clamped inverter at low modulation index. The previous papers introduce many multiple circuits replacing Si diode with SiC diode to reduce the switching loss. In the neutral-point-clamped inverter, the switching loss can be also reduced by replacing device in the clamp diode. However, the switching loss in IGBT is large and the reduced switching loss cannot be still neglected. It is expected that the reverse recovery effect can be infrequent and the switching loss can be considerably reduced by the proposed method. Therefore, it is also possible to operate the inverter at the higher frequency with the better system efficiency and reduce the volume, weight and cost of filters and heatsink. The effectiveness of the proposed method is verified by numerical analysis and experiment results.

Neutral Deinking of Old Newspapers Contaminated with Flexo Ink - Evaluation of the deinking efficiency of alcohol type neutral deinking agents - (플렉소 잉크가 포함된 신문고지의 중성 탈묵 - 알코올계 계면활성제의 효과 평가 -)

  • Ryu, Hoon;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.4 s.117
    • /
    • pp.31-40
    • /
    • 2006
  • Presence of old newspapers printed with waterbased flexographic inks leads to a significant loss of brightness of the deinked pulp by flotation process. It has been shown that neutral or acidic flotation deinking has many advantages in recycling of flexo printed newsprints. A comparative experimental study was performed to evaluate the deinking efficiency of three alcohol type deinking agents in flotation deinking of flexo printed newspapers. Zeta potential of neutral deinked pulp was less negative than alkaline deinked pulp. Also neutral deinking was advantages in reducing turbidity, COD, and cationic de-mands of deinking process water.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

Optimized Low-Switching-Loss PWM and Neutral-Point Balance Control Strategy of Three-Level NPC Inverters

  • Xu, Shi-Zhou;Wang, Chun-Jie;Han, Tian-Cheng;Li, Xue-Ping;Zhu, Xiang-Yu
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.702-713
    • /
    • 2018
  • Power loss reduction and total harmonic distortion(THD) minimization are two important goals of improving three-level inverters. In this paper, an optimized pulse width modulation (PWM) strategy that can reduce switching losses and balance the neutral point with an optional THD of three-level neutral-point-clamped inverters is proposed. An analysis of the two-level discontinuous PWM (DPWM) strategy indicates that the optimal goal of the proposed PWM strategy is to reduce switching losses to a minimum without increasing the THD compared to that of traditional SVPWMs. Thus, the analysis of the two-level DPWM strategy is introduced. Through the rational allocation of the zero vector, only two-phase switching devices are active in each sector, and their switching losses can be reduced by one-third compared with those of traditional PWM strategies. A detailed analysis of the impact of small vectors, which correspond to different zero vectors, on the neutral-point potential is conducted, and a hysteresis control method is proposed to balance the neutral point. This method is simple, does not judge the direction of midpoint currents, and can adjust the switching times of devices and the fluctuation of the neutral-point potential by changing the hysteresis loop width. Simulation and experimental results prove the effectiveness and feasibility of the proposed strategy.

High Efficiency Control Strategy of TNPC Inverter Using Low-frequency Switching Method of Neutral Point Switch (중성점 스위치의 저주파 스위칭 기법을 이용한 TNPC 인버터의 효율 향상 기법)

  • Lee, Taeyeong;Cho, Younghoon;Lim, Seungbeom
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.329-330
    • /
    • 2015
  • This paper introduces a low-frequency switching method for the neutral line of TNPC inverters to achieve high efficiency. By applying the method, the switching loss in the neutral line is reduced. In order to compensate the current distortion near zero-crossing points, the partial switching strategy is applied. Both the simulation and the experimental results verify the usefulness of the proposed method.

  • PDF

Sensitivity analysis of flexural strength of RC beams influenced by reinforcement corrosion

  • Hosseini, Seyed A.;Shabakhty, Naser;Khankahdani, Fardin Azhdary
    • Structural Engineering and Mechanics
    • /
    • v.72 no.4
    • /
    • pp.479-489
    • /
    • 2019
  • The corrosion of reinforcement leads to a gradual decay of structural strength and durability. Several models for crack occurrence prediction and crack width propagation are investigated in this paper. Analytical and experimental models were used to predict the bond strength in the period of corrosion propagation. The manner of flexural strength loss is calculated by application of these models for different scenarios. As a new approach, the variation of the concrete beam neutral axis height has been evaluated, which shows a reduction in the neutral axis height for the scenarios without loss of bond. Alternatively, an increase of the neutral axis height was observed for the scenarios including bond and concrete section loss. The statistical properties of the parameters influencing the strength have been deliberated associated with obtaining the time-dependent bending strength during corrosion propagation, using Monte Carlo (MC) random sampling method. Results showed that the ultimate strain in concrete decreases significantly as a consequence of the bond strength reduction during the corrosion process, when the section reaches to its final limit. Therefore, such sections are likely to show brittle behavior.