• Title/Summary/Keyword: Neutral System

Search Result 1,091, Processing Time 0.025 seconds

EXISTENCE UNIQUENESS AND STABILITY OF NONLOCAL NEUTRAL STOCHASTIC DIFFERENTIAL EQUATIONS WITH RANDOM IMPULSES AND POISSON JUMPS

  • CHALISHAJAR, DIMPLEKUMAR;RAMKUMAR, K.;RAVIKUMAR, K.;COX, EOFF
    • Journal of Applied and Pure Mathematics
    • /
    • v.4 no.3_4
    • /
    • pp.107-122
    • /
    • 2022
  • This manuscript aims to investigate the existence, uniqueness, and stability of non-local random impulsive neutral stochastic differential time delay equations (NRINSDEs) with Poisson jumps. First, we prove the existence of mild solutions to this equation using the Banach fixed point theorem. Next, we demonstrate the stability via continuous dependence initial value. Our study extends the work of Wang, and Wu [16] where the time delay is addressed by the prescribed phase space 𝓑 (defined in Section 3). To illustrate the theory, we also provide an example of our methods. Using our results, one could investigate the controllability of random impulsive neutral stochastic differential equations with finite/infinite states. Moreover, one could extend this study to analyze the controllability of fractional-order of NRINSDEs with Poisson jumps as well.

A Standard Way of Constructing a Data Warehouse based on a Neutral Model for Sharing Product Dat of Nuclear Power Plants (원자력 발전소 제품 데이터의 공유를 위한 중립 모델 기반의 데이터 웨어하우스의 구축)

  • Mun, D.H.;Cheon, S.U.;Choi, Y.J.;Han, S.H.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.12 no.1
    • /
    • pp.74-85
    • /
    • 2007
  • During the lifecycle of a nuclear power plant many organizations are involved in KOREA. Korea Plant Engineering Co. (KOPEC) participates in the design stage, Korea Hydraulic and Nuclear Power (KHNP) operates and manages all nuclear power plants in KOREA, Dusan Heavy Industries manufactures the main equipment, and a construction company constructs the plant. Even though each organization has a digital data management system inside and obtains a certain level of automation, data sharing among organizations is poor. KHNP gets drawing and technical specifications from KOPEC in the form of paper. It results in manual re-work of definition and there are potential errors in the process. A data warehouse based on a neutral model has been constructed in order to make an information bridge between design and O&M phases. GPM(generic product model), a data model from Hitachi, Japan is addressed and extended in this study. GPM has a similar architecture with ISO 15926 "life cycle data for process plant". The extension is oriented to nuclear power plants. This paper introduces some of implementation results: 1) 2D piping and instrument diagram (P&ID) and 3D CAD model exchanges and their visualization; 2) Interface between GPM-based data warehouse and KHNP ERP system.

A Study on Product Information Exchange between Heterogeneous Systems including Commercial PDM Systems (상용 PDM을 포함한 이기종 시스템 간의 제품정보 교환에 관한 연구)

  • Yang, Tae-Ho;Yoon, Tae-Hyuck;Choi, Sang-Su;Noh, Sang-Do
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.3
    • /
    • pp.175-186
    • /
    • 2008
  • For the success to PLM in manufacturing industries, the creation, management and coordination of all product-related information are essential, and the exchange of product information and data has become an important part of the product development. In this paper, we define the neutral schema, and it refers to PLM Services. Based on this neutral schema, we develop the PLM Integrator to exchange product information and data between diverse heterogeneous systems including PDM systems. We apply the PLM Integrator developed in this paper to commercial PDM systems such as SmarTeam, Teamcenter Engineering and MEMPHIS which is a data exchange middleware system for VR applications. By implementations, exchanges of product information and data can be done without loss of information. Also, the PLM Integrator can upload and download product information, data and related files. The result of this paper can not only reduce unnecessary efforts for data exchanging between different information systems including PDM/PLM systems but also provide a collaborative environment for PLM.

ROBUST MIXED $H_2/H_{\infty}$ GUARANTEED COST CONTROL OF UNCERTAIN STOCHASTIC NEUTRAL SYSTEMS

  • Mao, Weihua;Deng, Feiqi;Wan, Anhua
    • Journal of applied mathematics & informatics
    • /
    • v.30 no.5_6
    • /
    • pp.699-717
    • /
    • 2012
  • In this paper, we deal with the robust mixed $H_2/H_{\infty}$ guaranteed-cost control problem involving uncertain neutral stochastic distributed delay systems. More precisely, the aim of this problem is to design a robust mixed $H_2/H_{\infty}$ guaranteed-cost controller such that the close-loop system is stochastic mean-square exponentially stable, and an $H_2$ performance measure upper bound is guaranteed, for a prescribed $H_{\infty}$ attenuation level ${\gamma}$. Therefore, the fast convergence can be fulfilled and the proposed controller is more appealing in engineering practice. Based on the Lyapunov-Krasovskii functional theory, new delay-dependent sufficient criteria are proposed to guarantee the existence of a desired robust mixed $H_2/H_{\infty}$ guaranteed cost controller, which are derived in terms of linear matrix inequalities(LMIs). Furthermore, the design problem of the optimal robust mixed $H_2/H_{\infty}$ guaranteed cost controller, which minimized an $H_2$ performance measure upper bound, is transformed into a convex optimization problem with LMIs constraints. Finally, two simulation examples illustrate the design procedure and verify the expected control performance.

An Approach for Construction of Shipyard Simulation Environment based on Neutral File Format (중립파일 기반의 조선소 시뮬레이션 환경에 관한 연구)

  • Woo, Jong Hun;Hwang, Yoon-Suk;Nam, Jong-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.1
    • /
    • pp.18-28
    • /
    • 2016
  • In shipbuilding, the scheduling system is susceptible to sudden changes and thus it turns to be difficult to predict the differences between schedule and production records in advance. A computer-based simulation is commonly utilized to overcome the discrepancies occurred in estimating workloads and resulting processing times. The main drawback of this simulation-based solution is its limited applicability because, in most cases, each shipyard requires specific and customized simulation environment. By standardizing the planning data of the midterm scheduling system, as proposed in this paper, the efficiency of the current simulation model can be enhanced. To present an alternative approach, this paper begins with the analysis of the complex planning data structure of several shipyards and then proceeds to construct a standard data structure based on the neutral format. An interface application is developed for the data transaction and simulation in on-line environment. As a result, a simulation-based production management of shipyards can be achieved by the efficient prediction of planning and scheduling.

Transient Characteristics of a Transformer Type SFCL Applying the Superconductor and the Normal-conductor into the Secondary Winding (초전도체 및 상전도체의 변압기 2차측 적용에 따른 변압기형 SFCL 특성 비교)

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.873-877
    • /
    • 2016
  • This paper proposed the structure that applied superconductors to the neutral line of a transformer and applied the normal conductors to the third line. The superconductor applied to the neutral line of a transformer limited the peak value of initial fault current, while the normal conductor finally limited the fault current. In order to secure the operating reliability of transformer type Superconducting Fault Current Limiter (SFCL) of previously proposed structure, we analyzed the operating characteristics according to the fault types. We tested a line-to-ground fault and a line-to-line fault. As a result of the experiment, all the faults showed that the superconductor stably limited the peak-value of initial fault current. Also, the normal conductor finally limited the fault current. Based on this research results, We thought that if the structure of inserting superconductor into the neutral line is applied to the real system, it could improve the reliability and stability of the power system.

The Design Flowchart of Earthing System for Building Electrical Installations in Accordance with International Standards (국제표준에 따른 건축전기설비의 접지시스템 설계순서)

  • Lee, Ju-Cheol;Yeom, Jin-Geun;Jeong, Seung-Hyun;Byeon, Cheol-Gyun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.113-120
    • /
    • 2014
  • In this paper, designing of an earthing system in accordance with international standards with regard to 22.9kV-y multi-grounded neutral system is discussed and confirmed that the consumer's earthing system can be a part of a global earthing system by interconnecting its earthing system with the neutral conductor of 22.9kV-y multi-grounded system. Further, it is proposed that some modification of the earthing system design flowchart given in the international standards are necessary when considering the equipotential bonding, lightning protection, and telecommunications facilities as well as the basic safety requirements.

Design of the vacuum pumping system for the KSTAR NBI device (KSTAR 중성빔 입사(NBI) 장치 배기계통 설계)

  • 오병훈;인상렬;조용섭;김계령;최병호
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4B
    • /
    • pp.548-555
    • /
    • 1999
  • The NBI (Neutral BGeam Injection) System for the Korea Superconducting Tokamak Advanced Research (KSTAR) is composed of ion sources, neutralizers, bending magnets, ion dumps, and calorimeter. The vacuum chamber, in which all of the beam line components are enclosed, is composed of differential pumping system for the effective transfer of the neutral beams. The needed pumping speeds of each of the divided vacuum chamber and the optimized gas flow rate ot the neutralizer were calculated with the help of the particle balance equations. The minimum gas flow rate to the ion sources for producing needed beam current (120kV, 65A, 78MW), the pressure distributions in the vacuum chamber for minimizing re-ionization loss, and the beam loss rate on the beam line components were used as the input in the calculation. Also the scenario for short pulse operation was determined by analysing the time dependent equations. It showed that beam extraction during less than 0.5 sec could be made only with TMP.

  • PDF

Analysis and Design of a Three-Phase Synchronous Solid-state Var Compensator using Neutral-Point-Clamped Inverter (NPC 인버터를 이용한 3상 동기형 SVC의 해석 및 설계)

  • Lim, Su-Saeng;Lee, Eun-Woong;Kim, Sung-Heon;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.42-45
    • /
    • 1997
  • A synchronous solid-state var compensator(SSVC) system which employs a three-phase neutral-point-darned (NPC) inverter is presented and analyzed for high voltage and high power applications. The proposed SSVC system can compensate for leading and lagging displacement factor. An optimal pulse-width-modulation (PWM) is used as a means of reducing the size of reactive components. A equivalent model is obtained using DQ-transform, and the characteristic of open-loop system are archived from DC and AC analyzes. A $\alpha$ phase-shift control is suggested using a self-controlled dc bus.

  • PDF

A Study on the Insulation Methods of 220V Home Appliances and Wiring Devices (승압에 따르는 220V용 전기기기의 절연방식 결정에 관한 연구)

  • Sung Won Rhee
    • 전기의세계
    • /
    • v.20 no.4
    • /
    • pp.5-11
    • /
    • 1971
  • This is a study on the insulation methods of home appliances and wiring devices proper to the new electric distribution system, primary side is 22.9/13.2KV, 3 phase 4 wire multigrounding system and secondary side is 380/220V, 3 phase 4 wire common neutral system. 1800V is determined as the electrical insulation voltage of the functional insulation because the abnormal voltage rise of the neutral line is 1300V. In the case of the functional insulation faults, the following safety methods will be suggested to protect the accidental faults: (a) class I appliance (accessible metal part is earthed), (b) class II appliance (doublly insulated), (c) class III appliance (operates at low voltage source). The mechanisms of the wiring devices are not improved to guarantee for the harmful electric shock but also the electrical insulation voltage is rised to 2000V.

  • PDF