Eliminating the Neutral Current by the Power Compensator without using Energy Storage Elements (에너지저장요소를 사용하지 않는 전력보상기에 의한 중성선 전류의 제거)

  • Kim, Hyo-Seong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.6
    • /
    • pp.330-335
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers qq, qr were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storge element.

  • PDF

Neutral Line Current Compensation Method of Active Power Filter (전력용 능동 필터의 중성선 전류 저감 기법)

  • Min, Joon-Ki;Kim, Hyo-Sung;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.504-506
    • /
    • 2005
  • This paper proposes a new neutral current reduction method using PQR instantaneous power theory on the active power filter, unbalanced nonlinear load condition in three-phase four-wire systems. For reduction of neutral line current, the single phase active power filter is used and its performance is same with the three-phase four-wire active power filter. For fully-digital implementation, ramp comparison PWM method was adopted. Simulation results verify good performance of the proposed current control strategy on the shunt APFs.

  • PDF

Analysis on the Protective Coordination on Neutral Line of Main Transformer in Power Distribution Substation with Superconducting Fault Current Limiter (MTR 중성점 접지에 초전도 전류제한기 적용시 지락과전류계전기 동작 분석)

  • Kim, Jin-Seok;Lim, Sung-Hun;Moon, Jong-Fil;Kim, Jae-Chul;Hyun, Ok-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2089-2094
    • /
    • 2009
  • The fault current has increased due to growth of distributed generations for the large power demand in power distribution system. To solve some problem such as excess of the circuit breaker's cut-off ratings, the superconducting fault current limiter(SFCL) has been progressed. However, the operational characteristics of the relay is changed by SFCL. Therefore, the proper impedance for the SFCL should be selected to keep protective coordination with the SFCL when SFCL is introduced on the neutral line of main transformer in distribution system. In this paper, the proper normal conducting resistance was suggested to solve the problem in case of the protection coordination with SFCL.

The Calculation Method of Shielding Coefficient of Neutral Line against an Induced Voltage by an Aerial Power Distribution Line Reflecting the Principle of Earth Return Current (가공 배전선의 전자유도전압에 대하여 대지 귀로전류 원리를 반영한 중성선 차폐계수 계산 방법)

  • Lee, Sangmu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.86-91
    • /
    • 2016
  • To solve the problem of the excessive error caused by using a single value for the shielding effect of the neutral line of an electric power distribution line in the calculation of the voltage it induces in a telecommunication line, the general expression that was previously developed to reflect the mechanism of voltage induction by a distribution line with multiple grounds is employed in this paper to represent the relationship between the leakage current rates at each ground pole. In this way, the formula for calculating the shielding effect of the neutral line can be factorized against the unbalanced current flowing in the neutral line, which is the root current of induction. This shielding coefficient of the neutral line is not constant, but can vary when a range of induced voltages is generated in the whole power distribution line. The calculation method developed herein reduces the error rate to one tenth of that of the existing calculation result in the case of overestimation and increases it by 14% in the case of underestimation.

Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer (단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석)

  • Kim, Jong-Gyeum;Kim, Ji-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.3
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

Formulation of Calculation Method for Inducing Current by Aerial Power Distribution Line (가공 배전선에 의한 전자유도 발생 전류 계산 방법)

  • Lee, Sangmu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.30-36
    • /
    • 2015
  • The formulation of calculation method for electromagnetic inducing current by aerial power distribution line is established. Nearby telecommunication cables can be induced due to the leakage of neutral current because the neutral line of power distribution is grounded at every 50 m distance. By the existing calculation method, the neutral line is regarded as a shielding conductor and the neutral current roles as an inducing current. So the error range to real measurement value is largely extended because the changing effect of leakage current flowing in the ground is not reflected. The leakage current returns to the power substation through the ground and is cumulated as being closer to the substation. When this practical inducing mechanism is applied, the deviation rate of calculation can be drastically reduced within about 100 % range compared to 1000 % of the exsiting method.

A Novel Three-Phase Four-Wire Shunt Active Filter to Eliminate Neutral Current (高調波 中性電流를 低減시키기 위한 3相4線 竝列形 能動필터에 關한 硏究)

  • 고경수;김래기;유권종;송진수;김시경
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.184-190
    • /
    • 1998
  • Most buildings and factories are supplied with electric power by three-phase four-wire low voltage electric distribution system. This method pollutes the neutral line and utility sources with harmonic currents. Today, development of power conversion technology and the popularization of computer cause the neutral current to become serious. In this paper, a novel three-phase four-wire active filter is proposed to solve these harmonic problems has two purposes. The first purpose of the proposed active filiter is that the phase current has a sinusoidal waveform shape under the nonlinear load. The second purpose of the proposed active filiter is that the current on the neutral line become zero under the unbalanced power source and under the varring load conditions. The ability of the shunt active filiter has been proved to be excellent through simulations under the varring load conditions.

  • PDF

Theoretical Study of Neutral Section Considering the Driving Characteristics of ATO Urban Railway Vehicle (자동운전 도시철도차량의 운전특성을 고려한 절연구분장치 이론적 고찰)

  • Lee, Jae-Bong;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1470-1474
    • /
    • 2013
  • In this paper, proper length of neutral section and neutral section system configuration is proposed to minimize accidents if ATO urban railway vehicle stops maintaining the leading vehicles in air section at regular intervals. When considering the minimum voltage sensing of power conversion unit in the urban railway vehicle, the effective length of 14,280[mm] with neutral section can be minimized damage due to high current because the urban railway vehicle is very little present chance compare neutral section with pantograph interval installed on a unit vehicle. In addition, uplift of catenary line and contact wire consider to minimize damage. The result of theoretical review, as the proposed neutral section shorter, isolated neutral section is effective than the integrated neutral section.

Eliminating the Neutral Current by the Instantaneous Reactive Power Compensation (순시무효전력 보상에 의한 중성선 전류의 제거)

  • Kim, Hyo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.131-133
    • /
    • 1998
  • This paper, proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of the three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

THE EFFECT OF DOPANT OUTDIFFUSION ON THE NEUTRAL BASE RECOMBINATION CURRENT IN Si/SiGe/Si HETEROJUNCTION BIPOLAR TRANSISTORS

  • Ryum, Byung-R.;Kim, Sung-Ihl
    • ETRI Journal
    • /
    • v.15 no.3
    • /
    • pp.61-69
    • /
    • 1994
  • A new analytical model for the base current of Si/SiGe/Si heterojunction bipolar transistors(HBTs) has been developed. This model includes the hole injection current from the base to the emitter, and the recombination components in the space charge region(SCR) and the neutral base. Distinctly different from other models, this model includes the following effects on each base current component by using the boundary condition of the excess minority carrier concentration at SCR boundaries: the first is the effect of the parasitic potential barrier which is formed at the Si/SiGe collector-base heterojunction due to the dopant outdiffusion from the SiGe base to the adjacent Si collector, and the second is the Ge composition grading effect. The effectiveness of this model is confirmed by comparing the calculated result with the measured plot of the base current vs. the collector-base bias voltage for the ungraded HBT. The decreasing base current with the increasing the collector-base reverse bias voltage is successfully explained by this model without assuming the short-lifetime region close to the SiGe/Si collector-base junction, where a complete absence of dislocations is confirmed by transmission electron microscopy (TEM)[1].The recombination component in the neutral base region is shown to dominate other components even for HBTs with a thin base, due to the increased carrier storage in the vicinity of the parasitic potential barrier at collector-base heterojunction.