• Title/Summary/Keyword: Network topology

Search Result 1,187, Processing Time 0.103 seconds

New Single-stage Interleaved Totem-pole AC-DC Converter for Bidirectional On-board Charger

  • ;Kim, Sang-Jin;Kim, Byeong-U;Sin, Yang-Jin;Choe, Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.192-194
    • /
    • 2018
  • In this paper a new single-stage ac-dc converter with high frequency isolation and low components count is introduced. The proposed converter is constructed using two interleaved boost circuits in the grid side and non-regulating full bridge in the DC side. An optimized switching is implemented on the two interleaved boost circuits resulting in a ripple-free grid current without a ripple cancellation network; hence very small filter inductors are used. A simple and reliable closed-loop control system is easily implemented, since the phase-shift angle is the only independent variable. Moreover, current imbalance is avoided in the presented topology without current control loop in each phase. The proposed charger charges the battery with a sinusoidal-like current instead of a constant direct current. ZVS turn on of all switches is achieved throughout the operation in both directions of power flow without any additional components.

  • PDF

An Ant-based Routing Method using Enhanced Path Maintenance for MANETs (MANET에서 향상된 경로 관리를 사용한 개미 기반 라우팅 방안)

  • Woo, Mi-Ae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.9B
    • /
    • pp.1281-1286
    • /
    • 2010
  • Ant-based routing methods belong to a class of ant colony optimization algorithms which apply the behavior of ants in nature to routing mechanism. Since the topology of mobile ad-hoc network(MANET) changes dynamically, it is needed to establish paths based on the local information. Subsequently, it is known that routing in MANET is one of applications of ant colony optimization. In this paper, we propose a routing method, namely EPMAR, which enhances SIR in terms of route selection method and the process upon link failure. The performance of the proposed method is compared with those of AntHocNet and SIR. Based on he analysis, it is proved that the proposed method provided higher packet delivery ratio and less critical link failure than AntHocNet and SIR.

Optimal Placement of Measurement Using GAs in Harmonic State Estimation of Power System (전력시스템 고조파 상태 춘정에서 GA를 미용한 최적 측정위치 선정)

  • 정형환;왕용필;박희철;안병철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.8
    • /
    • pp.471-480
    • /
    • 2003
  • The design of a measurement system to perform Harmonic State Estimation (HSE) is a very complex problem. Among the reasons for its complexity are the system size, conflicting requirements of estimator accuracy, reliability in the presence of transducer noise and data communication failures, adaptability to change in the network topology and cost minimization. In particular, the number of harmonic instruments available is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents a new HSE algorithm which is based on an optimal placement of measurement points using Genetic Algorithms (GAs) which is widely used in areas such as: optimization of the objective function, learning of neural networks, tuning of fuzzy membership functions, machine learning, system identification and control. This HSE has been applied to the Simulation Test Power System for the validation of the new HSE algorithm. The study results have indicated an economical and effective method for optimal placement of measurement points using Genetic Algorithms (GAs) in the Harmonic State Estimation (HSE).

A Configuration method of RIO for the Assured Service in Differentiated Services (DiffServ 방식의 Assured Service를 위한 자원 할당 및 RIO 변수 설정 방안의 제안)

  • Hur, Kyeong;Lee, Heyung-Sub;Shin, Dong-Beom;Eom, Doo-Seop;Tchah, Kyun-Hyon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.6C
    • /
    • pp.571-580
    • /
    • 2002
  • In this paper, we relatively differentiate maximum delay for each Assured Service subclass in Differentiated Services by allocating bandwidth to each subclass differently. To maximize the throughput for the In-profile traffic and the link utilization, we propose a Cofiguration method of RIO and the admission control criterion based on the buffer size determined by the network topology and the ratio of bandwidth allocated to each subclass. Simulation results show that the proposed method can calculate the capacity to guarantee the QoS for the Assured Service and maximize the throughput for the In-profile traffic and the link utilization by applying the RIO parameter values set through the proposed configuration method.

Study on New Encoding based GA for Solving Bicriteria Network Topology Design Problems (2목적 네트워크 토폴로지 설계 문제를 풀기위한 새로운 엔코딩 기반의 유전자 알고리즘에 대한 연구)

  • Kim, Jong-Ryul;Lee, Jae-Uk;Yoo, Jung-Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05a
    • /
    • pp.289-292
    • /
    • 2003
  • 인터넷이 발전함에 따라 네트워크 시스템의 토폴로지 설계에 관한 여러 가지 문제들에 대한 관심이 증가하고 있다. 이러한 네트워크의 토폴로지 구조는 서비스 센터, 터미널(사용자), 연결 케이블로 이루어져 있다. 근래에 이런 네트워크 시스템들은 사용자들로부터의 요구사항이 많아지고 있기에 주로 광케이블로 구축하는 경우가 점차 늘어나고 있다지만, 광케이블의 비판 비용을 고려하면 네트워크의 구조가 스패닝 트리(spanning tree)로 구축되어 지는 것이 바람직하다고 볼 수 있다. 네트워크 토폴로지 설계 문제들은 연결비용, 평균 메시지 지연, 네트워크 신뢰도 등과 같은 설계 기준들을 최적으로 만족하는 토폴로지를 탐색하는 것으로 정의될 수 있다. 최근에 유전자 알고리즘(GA)은 네트워크 최적화 문제, 조합 최적화 문제, 다목적 최적화 문제 등과 같은 관련된 분야에서 많은 연구들이 이루어지고 있으며 또한, 많은 실세계의 문제를 위한 최적화 기술로서 그 잠재력을 매우 주목 받고 있다. 본 논문에서는 연결비용, 평균 메시지 지연, 네트워크 신뢰도를 고려하여, 광케이블로 구성되어 지는 광대역통신 네트워크의 2목적 네트워크 토폴로지 설계 문제들을 풀기 위한 GA를 제안한다. 또한, 후보 네트워크 토폴로지 구조를 염색체(chromosome)로 표현하기 위해 Prtifer수(PN_와 클러스터 스트링으로 구성되어지는 새로운 엔코딩 방법도 제안한다. 마지막으로 수치예를 통해 제안한 GA의 성능을 평가할 것이다.

  • PDF

Design of Self-Organizing Fuzzy Polynomial Neural Networks Architecture (자기구성 퍼지 다항식 뉴럴 네트워크 구조의 설계)

  • Park, Ho-Sung;Park, Keon-Jun;Oh, Sung-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2519-2521
    • /
    • 2003
  • In this paper, we propose Self-Organizing Fuzzy Polynomial Neural Networks(SOFPNN) architecture for optimal model identification and discuss a comprehensive design methodology supporting its development. It is shown that this network exhibits a dynamic structure as the number of its layers as well as the number of nodes in each layer of the SOFPNN are not predetermined (as this is the case in a popular topology of a multilayer perceptron). As the form of the conclusion part of the rules, especially the regression polynomial uses several types of high-order polynomials such as linear, quadratic, and modified quadratic. As the premise part of the rules, both triangular and Gaussian-like membership function are studied and the number of the premise input variables used in the rules depends on that of the inputs of its node in each layer. We introduce two kinds of SOFPNN architectures, that is, the basic and modified one with both the generic and the advanced type. The superiority and effectiveness of the proposed SOFPNN architecture is demonstrated through nonlinear function numerical example.

  • PDF

A Simple Power Management Scheme with Enhanced Stability for a Solar PV/Wind/Fuel Cell Fed Standalone Hybrid Power Supply using Embedded and Neural Network Controller

  • Thangavel, S.;Saravanan, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1454-1470
    • /
    • 2014
  • This paper propose a new power conditioner topology with intelligent power management controller that integrates multiple renewable energy sources such as solar energy, wind energy and fuel cell energy with battery backup to make best use of their operating characteristics and obtain better reliability than that could be obtained by single renewable energy based power supply. The proposed embedded controller is programmed for maintaining a constant voltage at PCC, maximum power point tracking for solar PV panel and WTG and power flow control by regulating the reference currents of the controller on instantaneous basis based on the power delivered by the sources and load demand. Instantaneous variation in reference currents of the controller enhances the controller response as it accommodates the effect of continuously varying solar insolation and wind speed in the power management. The power conditioner uses a battery bank with embedded controller based online SOC estimation and battery charging system to suitably sink or source the input power based on the load demand. The simulation results of the proposed power management system for a standalone solar/WTG/fuel cell fed hybrid power supply with real time solar radiation and wind velocity data collected from solar centre, KEC for a sporadically varying load demand is presented in this paper and the results are encouraging in reliability and stability perspective.

High-Efficiency Converter for Automotive Headlamp Using New H-type Snubber (새로운 H-type 스너버를 이용한 차량 헤드램프용 고효율 컨버터)

  • Kim, Sung-Joo;Kim, Sun-Pil;Jung, Tae-Uk;Park, Sung-Jun;Park, Seong-Mi
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.65-72
    • /
    • 2015
  • Recently, LED light has been increasingly adopted for vehicles in both domestic and foreign automotive markets, while a variety of LED lights have been developed to be used particularly for headlamps. In this paper, we propose an H-type resonant snubber circuit topology for high efficiency of vehicle LDM (LED Driver Module) and realized LDM functions for vehicle headlamp by designing high-efficiency convertors. In addition, this study reduced the financial burden by configuring the system to control the whole with micom except for the use of individual dedicated chips to drive LED for high and low beam. In order to verify the validity of the proposed H-type resonant snubber capable of soft switching, simulations were performed using PSIM. As a result, the validity was experimentally verified by creating a prototype. Moreover, in order to actually attach the headlamp, the performance of the proposed convertor was confirmed by designing LDM to the limited size. Communications between the headlamp and higher controller were realized using LIN(Local Interconnect Network).

Biased Multistage Inter connection Network in Multiprocessor System (다중프로세서 시스템에서 편향된 다단계 상호연결망)

  • Choi, Chang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1889-1896
    • /
    • 2011
  • There has been a lot of researches to develop techniques that provide redundant paths, there by making Multistage Interconnection Networks(MINs) fault tolerant. So far, the redundant paths in MINs have been realized by adding additional hardware such as extra stages or duplicated data links. This paper presents a new MIN topology called Hierarchical MIN. The proposed MIN is constructed with 2.5N-4 switching elements, which are much fewer than that of the classical MINs. Even though there are fewer hardware than the classical MINs, the HMIN possesses the property of full access and also provides alternative paths for the fault tolerant. Furthermore, since there is the short cut in HMIN for the localized communication, it takes advantage of exploiting the locality of reference in multiprocessor systems. Its performance under varying degrees of localized communication is analysed and simulated.

Isolated Bidirectional CLLC Resonant Converter using Digital Control for LVDC Distribution System (디지털로 제어되는 저압 직류 배전용 절연형 양방향 CLLC 공진형 컨버터)

  • Jung, Jee-Hoon;Kim, Ho-Sung;Ryu, Myung-Hyo;Kim, Jong-Hyun;Kim, Tae-Jin;Baek, Ju-Won
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.379-380
    • /
    • 2012
  • A bidirectional full-bridge CLLC resonant converter using a digital control method is proposed for a LVDC power distribution system. This converter can operate under high power conversion efficiency since the CLLC resonant network has soft switching capability for primary switches and output rectifiers. In addition, the power conversion efficiency of any directions is exactly the same as each other because of the symmetric structure of the converter. Intelligent digital control methods are proposed to regulate output voltage under any power flow directions. A 5kW prototype converter was designed for a high-frequency galvanic isolation of 380V dc buses using a digital signal processor to verify the performance of the proposed topology and algorithms.

  • PDF