• Title/Summary/Keyword: Network communication area

Search Result 1,318, Processing Time 0.03 seconds

Design of BACnet/Zigbee Intrated System (BACnet/Zigbee 통합 시스템의 설계)

  • Kim, Se-Hwan;Park, Dong-Kyu;Hong, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1063-1068
    • /
    • 2008
  • BACnet(Building Automation and Control Networks) is a standard data communication protocol specifically designed for building automation and control systems, BACnet provides six options for data link layer protocols and these six data link layer options can be applied with various wired transmission media. Recently wireless technology prevails in automation area. ZigBee is an IEEE 802.15.4 based standard communication protocol for low-rate wireless personal area networks. In this study, we propose a BACnet over ZigBee model that adopts ZigBee communication channel as a wireless data link layer protocol in a BACnet-based communication network system. The technology proposed in this paper can expand the BACnet application using the advantages of wired and wireless integrated network solution.

Design and Implementation of an Interface Unit for Analysis of a CAN-Based Control System (CAN 기반 제어 시스템 분석을 위한 인터페이스 유닛 설계 및 구현)

  • Park, Byung-Ryuel;Jeong, Gu-Min;Ahn, Hyun-Sik;Kim, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.195-197
    • /
    • 2006
  • In this paper, an interface unit is designed to efficiently monitor transmission data in Controller Area Network(CAN)-based control systems. The CAN uses a serial multi master communication protocol that efficiently supports distributed real-time control with a very high level of data integrity, and communication speeds of up to 1Mbps. The interface unit is composed of a DSP controller which collects data on the CAN bus and transfers data to a personal computer via serial communication to save and display of interesting signals. The experimental system consists of three DSP controllers which represent electronic control units of a vehicle, an interface unit for analysing the data on the bus, and a graphic monitoring program coded on the Windows platform. The validity and the effectiveness of the proposed simple type of CAN interface unit are shown through the experimental results.

  • PDF

Fieldbus Communication Network Requirements for Application of Harsh Environments of Nuclear Power Plant (원전 극한 환경적용을 위한 필드버스 통신망 요건)

  • Cho, Jai-Wan;Lee, Joon-Koo;Hur, Seop;Koo, In-Soo;Hong, Seok-Boong
    • Journal of Information Technology Services
    • /
    • v.8 no.2
    • /
    • pp.147-156
    • /
    • 2009
  • As the result of the rapid development of IT technology, an on-line diagnostic system using the field bus communication network coupled with a smart sensor module will be widely used at the nuclear power plant in the near future. The smart sensor system is very useful for the prompt understanding of abnormal state of the key equipments installed in the nuclear power plant. In this paper, it is assumed that a smart sensor system based on the fieldbus communication network for the surveillance and diagnostics of safety-critical equipments will be installed in the harsh-environment of the nuclear power plant. It means that the key components of fieldbus communication system including microprocessor, FPGA, and ASIC devices, are to be installed in the RPV (reactor pressure vessel) and the RCS (reactor coolant system) area, which is the area of a high dose-rate gamma irradiation fields. Gamma radiation constraints for the DBA (design basis accident) qualification of the RTD sensor installed in the harsh environment of nuclear power plant, are typically on the order of 4 kGy/h. In order to use a field bus communication network as an ad-hoc diagnostics sensor network in the vicinity of the RCS pump area of the nuclear power plant, the robust survivability of IT-based micro-electronic components in such intense gamma-radiation fields therefore should be verified. An intelligent CCD camera system, which are composed of advanced micro-electronics devices based on IT technology, have been gamma irradiated at the dose rate of about 4.2kGy/h during an hour UP to a total dose of 4kGy. The degradation performance of the gamma irradiated CCD camera system is explained.

TF-CPABE: An efficient and secure data communication with policy updating in wireless body area networks

  • Chandrasekaran, Balaji;Balakrishnan, Ramadoss;Nogami, Yasuyuki
    • ETRI Journal
    • /
    • v.41 no.4
    • /
    • pp.465-472
    • /
    • 2019
  • The major challenge in wireless body area networks (WBAN) is setting up a protected communication between data consumers and a body area network controller while meeting the security and privacy requirements. This paper proposes efficient and secure data communication in WBANs using a Twofish symmetric algorithm and ciphertext-policy attribute-based encryption with constant size ciphertext; in addition, the proposed scheme incorporates policy updating to update access policies. To the best of the author's knowledge, policy updating in WBAN has not been studied in earlier works. The proposed scheme is evaluated in terms of message size, energy consumption, and computation cost, and the results are compared with those of existing schemes. The result shows that the proposed method can achieve higher efficiency than conventional methods.

A Dynamic Queue Management for Network Coding in Mobile Ad-hoc Network

  • Kim, Byun-Gon;Kim, Kwan-Woong;Huang, Wei;Yu, C.;Kim, Yong K.
    • International journal of advanced smart convergence
    • /
    • v.2 no.1
    • /
    • pp.6-11
    • /
    • 2013
  • Network Coding (NC) is a new paradigm for network communication. In network coding, intermediate nodes create new packets by algebraically combining ingress packets and send it to its neighbor node by broadcast manner. NC has rapidly emerged as a major research area in information theory due to its wide applicability to communication through real networks. Network coding is expected to improve throughput and channel efficiency in the wireless multi-hop network. Many researches have been carried out to employ network coding to wireless ad-hoc network. In this paper, we proposed a dynamic queue management to improve coding opportunistic to enhance efficiency of NC. In our design, intermediate nodes are buffering incoming packets to encode queue. We expect that the proposed algorithm shall improve encoding rate of network coded packet and also reduce end to end latency. From the simulation, the proposed algorithm achieved better performance in terms of coding gain and packet delivery rate than static queue management scheme.

Smart Integrated Monitoring System for Ensuring Indenpendent Network in Disaster Site (재난현장의 독립적 통신망 확보를 위한 스마트 통합 관제시스템)

  • Lee, Yang Sun
    • Journal of Digital Contents Society
    • /
    • v.18 no.5
    • /
    • pp.905-910
    • /
    • 2017
  • In this paper, we were proposed an on-site smart integrated monitoring system for securing an independent network infrastructure (wireless communication, image transmission and site situation detection) in disaster area. The proposed system was designed not only for the entire structure of the disaster safety communication network but also for the effective exchange of information between the field crew team and the field command and control center at the disaster site. Also, the proposed Smart Integrated Monitoring System supports wireless communication between field crews at the disaster site and supports communication with the drone to collect disaster scene video information. Therefore, the on-site smart integrated monitoring system enables to obtain the complete image of the surrounding area in case of a disaster and to efficiently command the field crew.

A Study on Development for Multiplexing of CAR Network with Controller Area Network (CAN) Communication Protocol (Controller Area Network (CAN) 통신 프로토콜을 사용한 자동차 Network의 다중화 기법의 개발에 관한 연구)

  • 정차근
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.29-32
    • /
    • 2001
  • This paper describes a development of the integrated controller system for car electrical signal control with CAN communication protocol. The CAN protocol is a robust serial bus system for the control of distributed module in the multiplexed network. After a brief of the main features of the CAN will be addressed, this paper presents the result of the development of the integrated hardware system overall control program.

  • PDF

Design of an In-vehicle Intelligent Information System for Remote Management (차량 원격 진단 및 관리를 위한 차량 지능 정보시스템의 설계)

  • Kim, Tae-Hwan;Lee, Seung-Il;Lee, Yong-Doo;Hong, Won-Kee
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1023-1026
    • /
    • 2005
  • In the ubiquitous computing environment, an intelligent vehicle is defined as a sensor node with a capability of intelligence and communication in a wire and wireless network space. To make it real, a lot of problems should be addressed in the aspect of vehicle mobility, in-vehicle communication, common service platform and the connection of heterogeneous networks to provide a driver with several intelligent information services beyond the time and space. In this paper, we present an intelligent information system for managing in-vehicle sensor network and a vehicle gateway for connecting the external networks. The in-vehicle sensor network connected with several sensor nodes is used to collect sensor data and control the vehicle based on CAN protocol. Each sensor node is equipped with a reusable modular node architecture, which contains a common CAN stack, a message manager and an event handler. The vehicle gateway makes vehicle control and diagnosis from a remote host possible by connecting the in-vehicle sensor network with an external network. Specifically, it gives an access to the external mobile communication network such as CDMA. Some experiments was made to find out how long it takes to communicate between a vehicle's intelligent information system and an external server in the various environment. The results show that the average response time amounts to 776ms at fixed place, 707ms at rural area and 910ms at urban area.

  • PDF

Social Network Analysis of author's interest area in Journals about Computer (컴퓨터 분야 논문지에서 저자의 관심분야에 대한 소셜 네트워크 분석)

  • Lee, Ju-Yeon;Park, Yoo-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.193-199
    • /
    • 2016
  • Recently there are many researches about analyzing the interaction between entities by social network analysis in various fields. In this paper, we are going to analyze the author's interests area at the biography section in Journal of the Korea Institute of Information and Communication Engineering by social network analysis. The results show that many authors in that journal are mainly focusing on embedded, security, image processing, wireless network, big data, USN, network, RFID.

Efficient Cross-Room Switch Mechanism for Indoor Room-Division-Multiplexing Based Visible Light Communication Network

  • Huang, Zhitong;Xiong, Jieqing;Li, Jianfeng;Ji, Yuefeng
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.351-356
    • /
    • 2015
  • Visible light communication (VLC) is considered to be an attractive scheme to realize the broadband wireless communication for an indoor environment. We present a room division multiplexing (RDM) mechanism for an indoor multi-room VLC network, which utilizes the spatial position of the LED lamp in different rooms as a novel dimension of network resource for multiplexing, and thus the network capacity is increased. In such a network, the service interruption caused by user cross-room movement is an important problem, and we propose a double-area-positioning based cross-room switch solution. An experimental platform demonstrates the RDM-deployed VLC network, and validates the performance of the presented switch mechanism.