• Title/Summary/Keyword: Network Operation

Search Result 3,322, Processing Time 0.033 seconds

A Study on the Future Strategy of KREONET through Analysis of Achievement and Future Demand

  • Park, Seongjin;Noh, Minki;Kim, Seunghae;Kwon, Woochang;Park, Chanjin;Cho, Buseung
    • Journal of Information Science Theory and Practice
    • /
    • v.10 no.spc
    • /
    • pp.154-163
    • /
    • 2022
  • The purpose of this paper is to illuminate the role and importance of National Research & Education Network (NREN) in the national research and education field and to establish the future strategy of KREONET in Korea. To this end, we first carefully analyze the footsteps of NREN in major overseas countries, KREONET achievements, and future demand for KREONET. The history of NREN's development is divided into the 2000s, 2010s, and present by era, and classified into network infrastructure, network service, and next-generation network technology by subject. KREONET achievements are divided into advanced research support, network backbone and operation, and network service. Future demand analysis of users who use KREONET was conducted through Korea Research International Incorporation, a survey company. This paper presents the future development strategy of KREONET by analyzing KREONET achievements and future demand.

Feasibility Study on the Conjunctive Operation of Water Transmission Systems from Multiple Source with Applying EPAnet (수리해석(水理解析) 모형(模型)을 이용한 다수원(多水源) 송수계통(送水系統)의 연계(連繫) 운영(運營) 방안(方案) 경제성(經濟性) 평가(評價) - 거제시(市)를 대상(對象)으로 -)

  • Ryu, Tae-Sang;Ha, Sung-Ryong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.609-619
    • /
    • 2007
  • The objective of this paper is to evaluate the feasibility of conjunctive Operation between Multi-regional water supply networks from multiple source as a effective way to meet two conditions: to minimize the electric cost for providing water demanded and meet the water flow rate for satisfying customers. EPAnet Model is used to calculate a hydraulic water distribution condition based on an integrated operation of water supply systems located in short distance. The modeling was conducted on several simulation cases including the individual operation by existing inter-regional water supply networks within short distance, the conjunctive operation of more than two existing networks with valve fully closed and full open constraint. As a study distribution system, water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. It was found that a well-allocated water supply scheme based on a conjunctive operation promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. The result such as unit district costs, pareto optimum pump combination sets will be applied to the optimization for a conjunctive operation of existing inter-regional water supply networks within short distance.

A Study of Voltage Control for Lower Side Parallel Transformer (병렬운전 변압기 전압제어 및 저압축 모선보호방식연구)

  • Yun, Gi-Seob;Baek, Seung-Do;Choi, Hyuck-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.233-236
    • /
    • 2001
  • Parallel operation scheme to several transformers is adopted because of the load increase, economic problem, or load shedding. For the transformer's parallel operation, loads proportional to each transformer's capacity must be allotted, and circulation currents must be limited as much as without causing any problem in a real operation. But, both transformers in parallel operation can be tripped when either faults at lower voltage side of a transformer or faults in a bus occurs. Therefore, parallel operation scheme to distribution transformers in Korea is not adopted in a normal state but only when loaded or load-shedded. These are due to the insufficiency of the construction in communication network and AVR scheme. Besides that, those are because bus bar protection scheme to lower voltage side of a transformer is not applied. In spite of enormous initial investment costs, advanced countries take so much account of power system reliability and stable supply that they adopt the parallel operation scheme in a normal state. One of the problems in parallel operation is the overheat of transformers due to the excessive circulation currents. This paper presents the scheme that controls voltages between both transformers using circulation currents that occurs in parallel operation.

  • PDF

A Study on the Method Improvement of the Integrated Railway Safety Audit System through the Analysis of Results (철도종합안전심사 결과 분석을 통한 효율적 심사방안 연구)

  • Song, Bo-Young;Song, Byeong-Ho;Oh, In-Tack
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2503-2516
    • /
    • 2011
  • According to Railway Safety Act, Korea Transportation Safety Authority (KOTSA) has been entrusted with 'Integrated Railroad Safety Audit (IRSA) and has implemented the safety audit to the railroad operation agencies such as Korea Railroad (KORAIL) and the railroad facility management organization such as the Korea Rail Network Authority (KR Network). The target of IRSA is to establish the effective rail safety management system and to raise the safety level of the railroad operation and facility agencies by checking synthetically their performance of safety duties with sincerity according to the Railway Safety Act. Even though newly introduced IRSA is conducted smoothly, it is necessary to study the methodology and criteria of the state's safety audit system. The purpose of this paper is to improve the efficiency of IRSA by the comparative research between IRSA and other similar safety audit system and to establish the consecutive improvement concept of IRSA. Second purpose is to confirm the effectiveness of IRSA by the analysis of the relationship between audit results and the safety level of the rail operation agencies.

  • PDF

Installation and Operation Test of a 22.9kV, 50MVA, HTS Cable for Real Utility Grid Application (실계통 적용을 위한 22.9kV, 50MVA, 초전도케이블 설치 및 운전 시험)

  • Sohn, Song-Ho;Yang, Hyung-Suk;Lim, Ji-Hyun;Oh, Seung-Ryle;Lee, Su-Kil;Jang, Hyun-Man;Hwang, Si-Dole
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.484-485
    • /
    • 2011
  • Since the year 2008, the first demonstration project of the superconducting cable for the KEPCO grid operation has been in progress. To apply the HTS (High Temperature Superconducting) cable system into the commercial network, a new test complex was built in the 154kV Icheon substation and the on site assembly of 22.9kV, 50MVA HTS cable with the cryogenic refrigeration system was finished. A full scale of HTS cable fabricated with 2nd generation wire is to be in service in KEPCO network. In this paper, a series of processes of the installation and operation test are introduced.

  • PDF

The Investigation of the Overseas Audit Systems for the Improvement of the Integrated Railroad Safety Audit System (철도종합안전심사제도 개선을 위한 해외 심사제도 분석)

  • Oh, In-Tack;Lee, Jong-Seock
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.719-728
    • /
    • 2007
  • Recently the assurance of railroad safety is very important issue in KOREA because there are lots of changes in the railroad industries. The Railway Safety Act was established in order to cope with these changes effectively and prevent the railroad transportation accidents. According to this law, Korea Transportation Safety Authority (KOTSA) has been entrusted with 'Integrated Railroad Safety Audit (IRSA)' and has implemented the safety audit to the railroad operation agencies such as Korea Railroad (KORAIL) and the railroad facility management organization such as the Korea Rail Network Authority (KR Network). The target of IRSA is to establish the effective rail safety management system and to raise the safety level of the railroad operation and facility agencies by checking synthetically their performance of safety duties with sincerity according to the Railway Safety Act. The purpose of this paper is to improve the efficiency of IRSA by the comparative research between IRSA and other similar safety audit system. To study the efficiency of IRSA, we investigated the rail safety audit systems of EU system specially France, England where the big changes have happened for the rail operation concepts and Japan where government entity control the railroad safety. The international standards of Occupational Health & Safety Assessment Series (OHSAS 18001), Quality Management System (ISO 9001) and Guidelines for Quality and/or Environmental Management Systems Auditing (ISO 19011) are investigated.

  • PDF

Analysis of Air Distribution in the Windbox System of the Utility Boiler (보일러 Windbox내 공기공급 계통의 유량분포 해석)

  • Park, Ho-Young;Kim, Sung-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.581-589
    • /
    • 2008
  • The pulverized coal combustion behavior in the utility boiler is very complex since so many physical and chemical processes happen in it, simultaneously. The mixing of pulverized coal with combustion air plays an important role in achieving the efficient combustion and stable boiler operation. The distribution of combustion air supplied to the furnace through the windbox damper system has not been clearly known since the individual measurements of air flow for each air nozzle were not possible, yet. The present study describes the CFD modelling of windbox damper system and aims to obtain the air flow rates and pressure loss coefficients across the present five damper systems, respectively. The one dimensional flow network model has been also established to get air flow distributions across the windbox damper, and applied to the actual plant operation condition. Compared with the designed air flow distribution, the modelled one gives a reasonable agreement. For the actual plant operation, the predicted air flow distribution at each air nozzle is differed with the designed data and strongly affected by the individual opening angle.

A Study on the operation and Maintenance system for optical subscriber loops using a broadband light source (넓은 대역 광원을 이용한 광 가입자 선로 운용보전 시스템에 관한 연구)

  • 이용기;이영호;박봉근
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.3B
    • /
    • pp.504-509
    • /
    • 2000
  • This paper presents a noble operation and maintenance system for the optical subscriber loops and its feasibility through several experiments. In this system, a broadband CW (Continuous Wave) light source I used as monitoring of testing signals. and a FGF(Fiber Grating Filter) of which reflective wavelength is independent, is inserted somewhere in each subscriber loop for the reflection of monitoring of testing signals. The propose of the system is quick decision. whether the loop is just fault or not. rather than detailed information of loop state. At present, most of operation and maintenance system for the optical subscriber loops adopts OTDR(optical time domain reflectometer) for testing function. the OTDR is useful for detailed test, but not adequate for simple test because of long testing time . And it is difficult to test PON network by using general OTDR that has a single-wavelength light source. Compared to using OTDR, the proposed system can afford to shorten testing time and to test PON network. Moreover, we can cut down the system cost by simplifying circuits of the optical light sources. Our results show that the proposed system operates well according to the purpose mentioned above.

  • PDF

A Restoration Automation Algorithm on a Fault in Substation of SCADA-coordinated Distribution Automation System (SCADA가 통합된 배전자동화 시스템의 변전소 사고 시 복구 자동화 알고리즘)

  • Hong, Jun-Ho;Lim, Il-Hyung;Lee, Seung-Jae;Kim, Tae-Wan;Choi, Myeon-Song;Ha, Bok-Nam;Lee, Sung-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2107-2114
    • /
    • 2009
  • It is impossible to take the instant action in the distribution system When fault occures in a substation because operation of the substation and the distribution system are separated. However the power system automation has been studying about unity operation and co-operation between SCADA and DAS(Distribution Automation System). In this paper proposes a new algorithm of efficiency restoration using a outage load switching to a healthy MTR a fault occurrence at a MTR in united system between DAS and SCADA. In addtion, proposed algorithm includes a outage restoration method which keeps MTR optimal capacity with reorganization of distribution network in case it can not restore outage state loads caused by shortage of healthy MTR remain capacity. In case that proposed sequence still can not complete restoration, this paper suggests a efficiency outage restoration with objective function included priority in outage loads. In the case studies, the proposed algorithm have been verified in 2 MTR and 3 MTR substation

Health Care Optimization by Maximizing the Air-Ambulance Operation Time

  • Melhim, Loai Kayed B.
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.2
    • /
    • pp.357-361
    • /
    • 2022
  • Employing the available technologies and utilizing the advanced means to improve the level of health care provided to citizens in their various locations. Citizens have the right to get a proper health care services despite the location of their residency or the distance from the health care delivery centers, a goal that can be achieved by utilizing air ambulance systems. In such systems, aircrafts and their life spans are the essential component, the flight duration of the aircraft during its life span is determined by the maintenance schedule. This research, enhances the air ambulance systems by presenting a proposal that maximizes the aircraft flight duration during its life span. The enhancement will be reached by developing a set of algorithms that handles the aircraft maintenance problem. The objective of these algorithms is to minimize the maximum completion time of all maintenance tasks, thus increasing the aircraft operation time. Practical experiments performed to these algorithms showed the ability of these algorithms to achieve the desired goal. The developed algorithms will manage the maintenance scheduling problem to maximize the uptime of the air ambulance which can be achieved by maximizing the minimum life of spare parts. The developed algorithms showed good performance measures during experimental tests. The 3LSL algorithm showed a higher performance compared to other algorithms during all performed experiments.