• Title/Summary/Keyword: Network Equipment Test

Search Result 154, Processing Time 0.028 seconds

TRADE-OFFS BETWEEN FUEL ECONOMY AND NOX EMISSIONS USING FUZZY LOGIC CONTROL WITH A HYBRID CVT CONFIGURATION

  • Rousseau, A.;Saglini, S.;Jakov, M.;Gray, D.;Hardy, K.
    • International Journal of Automotive Technology
    • /
    • v.4 no.1
    • /
    • pp.47-55
    • /
    • 2003
  • The Center for Transportation Research at the Argonne National Laboratory (ANL) supports the DOE by evaluating advanced automotive technologies in a systems context. ha has developed a unique set of compatible simulation tools and test equipment to perform an integrated systems analysis project from modeling through hardware testing and validation. This project utilized these capabilities to demonstrate the trade-off in fuel economy and Oxides of Nitrogen (NOx) emissions in a so-called ‘pre-transmission’ parallel hybrid powertrain. The powertrain configuration (in simulation and on the dynamometer) consists of a Compression Ignition Direct Ignition (CIDI) engine, a Continuously Variable Transmission (CVT) and an electric drive motor coupled to the CVT input shaft. The trade-off is studied in a simulated environment using PSAT with different controllers (fuzzy logic and rule based) and engine models (neural network and steady state models developed from ANL data).

Topological Locating of Power Quality Event Source

  • Won Dong-Jun;Moon Seung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.170-176
    • /
    • 2006
  • This paper proposes a topological locating algorithm to determine the location of the power quality event source. This algorithm makes use of the information on the topology of the monitored network and on the direction of PQ events. As a result, the bus incidence matrix is modified using monitor location and the direction matrix is constructed. With this information, the algorithm determines the suspected locations of the PQ events. To reduce suspicious areas, it utilizes event cause and related equipment. In case of line fault event, it calculates the distance from the monitor to the location of event source. The overall algorithm is applied to the IEEE test feeder and accurately identifies the event source location.

Fan Noise Prediction Method of Air Conditioning and Cooling System (공기조화 및 냉각시스템의 팬 소음예측 기법)

  • Lee, Jin-Young;Lee, Chan;Kil, Hyun-Gwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1318-1320
    • /
    • 2007
  • Fan noise prediction method is presented for air conditioning and/or cooling system applications where fan acts as an internal equipment having very complicated flow interaction with other various system components. The internal flow paths and distribution in the fan-applied systems such as computer or air conditioner are analyzed by using the FNM(Flow Network Modeling) with the flow resistances for flow elements of the system. Based on the fan operation point predicted from the FNM analysis results, the present fan noise model predicts overall sound power, pressure levels and spectrum. The predictions of the flow distribution, the fan operation and the noise level in electronic system by the present method are well agreed with 3-D CFD and actual noise test results.

  • PDF

Fan Noise Prediction Method of Air Cooling System (공기 냉각 시스템의 홴 소음 예측 기법)

  • Lee, Chan;Kil, Hyun-Gwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.9
    • /
    • pp.952-960
    • /
    • 2008
  • Fan noise prediction method is presented for air conditioning, automobile and electronic cooling system applications where fan acts as an internal equipment having very complicated flow interaction with other various system components. The internal flow paths and distribution in the fan-applied systems such as computer or air conditioner are analyzed by using the FNM(flow network modeling). Fan noise prediction method comprises two models for the discrete frequency noise due to rotating steady aerodynamic lift and blade interaction and for the broadband noise due to turbulent boundary layer and wake vortex shedding. Based on the fan operation point predicted from the FNM analysis results and fan design parameters, the present far noise model predicts overall sound pressure level and spectrum. The predictions for the flow distribution, the fan operation and the noise level in air cooling system by the present method are well agreed with 3-D CFD and actual noise test results.

Network Configuration, Time Management, and Data Storage for Urban Earthquake Disaster Preventing System (도시형 지진방재시스템을 위한 네트워크 구성, 시간관리 및 데이터 저장 방법)

  • Choi, Hun;Youn, Joosang;Heo, Gyeongyong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1675-1682
    • /
    • 2014
  • In this paper, we propose a precise time management and time synchronization based on real-time data storage and transmission scheme in design of seismic data acquisition system for urban earthquake disaster preventing system (UEDPS). It is possible to improve the performance of the existing research results through the proposed methods. To evaluate the performances of the proposed methods, we implemented a prototype system(H/W & S/W) and performed some experiments with real seismic data and test equipment generated data as the input.

Development of Short-circuit Testing Facility for Distribution Transformers (배전용 변압기 단락강도 시험설비 개발)

  • Park, Ji-Hun;Min, Yun-Hong;Kang, Young-Hak;You, Ho-Keun;Ahn, Kyu-Sun;Ham, Gil-Ho;Oh, Chang-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.64-67
    • /
    • 2002
  • To increase the short-circuit testing capacity of distribution transformers, testing facility has been installed for KEPCO in Vi-wang. The power supply of testing facility is directly supplied from the network substation located closely. Testing can be performed up to 300 kVA for single-phase transformers, 500 kVA for three-phase transformers. Operating with this facility, the distribution company is able to maintain the reliable supply of electricity. Also the critical quality of transformers from manufacturers can be verified by short-circuit testing. This paper describes the design concept and specification of newly developed equipment and the procedure of short-circuit test.

  • PDF

A Research of PLC application to NPCS of Nuclear Power Plant (원자력발전소 공정제어계통의 PLC 적용 연구)

  • Yang, Seung-Kwon;Park, Hyun-Shin;Park, Jong-Berm;Chung, Hak-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.804-806
    • /
    • 1998
  • Most of Instrumentation and control system in Nuclear Power Plant using analog equipment has a limitations in system designing and operation. So the network based PLC application to Nuclear Power Plant has been studied so far. This paper defines the configuration and method with Prototype which are to be applied to NPCS(NSSS Process Control System) of KNGR (Korea Next Generation Reactor). It is expected that Test result of NPCS Pototype will satisfy the essential requirements in designing KNGR.

  • PDF

Simulation of Fault-Arc using EMTP (EMTP를 이용한 아크 사고의 모의)

  • Byun, S.H.;Choi, H.S.;Chae, J.B.;Kim, C.H.;Han, K.N.;Kim, I.D.;Kim, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.850-852
    • /
    • 1996
  • High impedance fault (HIF) is defined as fault that general overcurrent relay can't detect or interrupt, Especially when HIF occur under 15 kV, energized high voltage conductor results in fire hazard, equipment damage or personal threat. Because most HIF occur arc, HIF detection using arc is to increase. Numerical arc model can be applied in an electromagnetic transients program (EMTP) to reproduce the dynamic and random characteristic of arcs for any insulator arrangement, current and system voltage. It allows the representation of any network configuration to be investigated, so the digital simulation of arc faults through air can be substitute for demanding power arc test.

  • PDF

Construction of IED Conformance Testing System (IED 적합성 인증시험 장치 구축)

  • Lee, N.H.;Kim, J.H.;Jang, B.T.;An, Y.H.;Hwang, K.C.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.489-490
    • /
    • 2007
  • In order to construct a digital substation based on IEC61850, All of the utility company should used IEDs to be verified and also vendors should get a certification from the international conformance testing organizationsuch as KEMA. So KEPRI in charge of POWER IT project related to SAS was required to IED conformance testing system, which can perform the test previously. The system, KEPCO developed, consists of HMI, IED (Intelligent Electronic Device), network equipment, V/I generator etc

  • PDF

Development of OPC UA based Smart Factory Digital Twin Testbed System (OPC UA 기반 스마트팩토리 디지털 트윈 테스트베드 시스템 개발)

  • Kim, Jaesung;Jeong, Seok Chan;Seo, Dongwoo;Kim, Daegi
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1085-1096
    • /
    • 2022
  • The manufacturing industry is continuously pursuing advanced technology and smartization as it converges with innovative technology. Improvement of manufacturing productivity is achieved by monitoring, analyzing, and controlling the facilities and processes of the manufacturing site in real time through a network. In this paper, we proposed a new OPC-UA based digital twin model for smart factory facilities. A testbed system for USB flash drive packaging facility was implemented based on the proposed digital twin model and OPC-UA data communication scheme. Through OPC-UA based digital twin model, equipment and process status information is transmitted and received from PLC to monitoring and control 3D digital models and physical models in real time. The usefulness of the developed digital twin testbed system was evaluated through usability test.