• 제목/요약/키워드: Nerve conduction

검색결과 290건 처리시간 0.031초

선박건조업에서 사용되는 그라인더의 진동평가와 수지진동증후군 예측 모델 개발 (Assessment of Vibration Produced by the Grinder Used in the Shipbuilding Industry and Development of Prospective Prevalence Model of Hand-arm Vibration Syndrome)

  • 임상혁;이윤근;박희석
    • 한국산업보건학회지
    • /
    • 제16권4호
    • /
    • pp.398-412
    • /
    • 2006
  • The purpose of this study is to investigate the relationship between the acceleration of vibration by the powered hand tools used in the shipbuilding industry, and to develop the prospective prevalence model for the hand-arm vibration syndrome among the shipbuilding workers.The acceleration levels and frequencies of six types of grinder were measured using the ISO5349 method along with the time of exposure to the vibration from the powered hand tools. Medical examination for 114 workers were performed using the cold provocation test. Comparisons were made between the estimated prevalence of hand-arm vibration syndrome from ISO5349 and the observed values from the medical examinations. By multiple regression, we developed the prospective prevalence model of hand-arm vibration syndrome produced by the hand tools used in the shipbuilding industry. 4 hour-energy-equivalent frequency-weighted accelerations were $6.23m/s^2$ in the grinding job done after welding, and $13.39m/s^2$ in the grinding job done before painting. The mean exposure time while holding powered hand tools was 4.64 hours. Prevalence rates of Raynaud's Phenomenon were 12.04% in the grinding after soldering, and 42.9% in the grinding before painting measured using the ISO5349 method. After exposure to vibration for 10.79 years, about a half of the workers in the grinding after welding could developed Raynaud's Phenomenon. For the workers in the grinding before painting, the latency was 5.02 years. The ISO equation for dose response relationship was not significantly correlated with observed recovery rates of finger skin temperatures, blood flows and amplitudes of nerve conduction velocities. A multiple regression model for dose-response relationship was proposed from the results. Recovery rate of the skin temperatures = -0.668+ 0.337 ${\times}$ 4 hour energy equivalent frequency-weighted accelerations + 0.767 ${\times}$ duration of vibration exposure(years) The validity was proved by multiple regression analysis after correlation transformation and regression results based on model-building data and validation data.

Chronic inflammatory demyelinating polyneuropathy in children: a report of four patients with variable relapsing courses

  • Chang, Soo Jin;Lee, Ji Hyun;Kim, Shin Hye;Lee, Joon Soo;Kim, Heung Dong;Kang, Joon Won;Lee, Young Mock;Kang, Hoon-Chul
    • Clinical and Experimental Pediatrics
    • /
    • 제58권5호
    • /
    • pp.194-198
    • /
    • 2015
  • Chronic inflammatory demyelinating polyneuropathy (CIDP) is a chronically progressive or relapsing symmetric sensorimotor disorder presumed to occur because of immunologic antibody-mediated reactions. To understand the clinical courses of CIDP, we report variable CIDP courses in children with respect to initial presentation, responsiveness to medical treatment, and recurrence interval. Four patients who were diagnosed with acute-onset and relapsing CIDP courses at Severance Children's Hospital, Seoul, Korea, were enrolled in this retrospective study. We diagnosed each patient on the basis of the CIDP diagnostic criteria developed in 2010 by the European Federation of Neurological Societies/Peripheral Nerve Society Guidelines. We present the cases of four pediatric patients diagnosed with CIDP to understand the variable clinical course of the disease in children. Our four patients were all between 8 and 12 years of age. Patients 1 and 2 were diagnosed with acute cerebellar ataxia or Guillain-$Barr{\acute{e}}$ syndrome as initial symptoms. While patients 1 and 4 were given only intravenous dexamethasone (0.3 mg/kg/day) for 5 days at the first episode, Patients 2 and 3 were given a combination of intravenous immunoglobulin (2 g/kg) and dexamethasone (0.3 mg/kg/day). All patients were maintained with oral prednisolone at 30 mg/day, but their clinical courses were variable in both relapse intervals and severity. We experienced variable clinical courses of CIDP in children with respect to initial presentation, responsiveness to medical treatment, and recurrence interval.

하지 감각이상 및 통증을 호소하는 당뇨병성 다발신경병증 환자에 대한 복합 한의치험 1례 (Case Report: Lower Extremity Paresthesia and Pain with Diabetic Polyneuropathy Combated with Complex Korean Medical Treatment)

  • 정성훈;이영선;성시윤;이한결;조기호;문상관;정우상;권승원
    • 대한한방내과학회지
    • /
    • 제44권2호
    • /
    • pp.231-243
    • /
    • 2023
  • Background: Diabetic polyneuropathy is the most common complication in diabetics, occurring in 50% of all cases. About 10-20% of all diabetics are accompanied by neurological pain, showing a tendency to increase with age. Clinical aspects are very diverse, from mild abnormalities on nerve conduction tests to severe abnormalities in all sensory, motor, and autonomic nerves; however, sensory symptoms usually precede motor symptoms. Patients typically express sensory symptoms, such as positive and negative symptoms, which decrease the quality of life and have marked clinical implications, such as increased morbidity and mortality. Although Western medical drugs, such as tricyclic antidepressants, anticonvulsants, and narcotic analgesics, are used for diabetic polyneuropathy, a standard treatment has not been established. Case report: A 65-year-old male with paresthesia and pain due to diabetic polyneuropathy was treated with Uchashinki-hwan, acupuncture, electroacupuncture, moxibustion, and Jungsongouhyul pharmacopuncture for 10 days. We used the Toronto Clinical Neuropathy Scoring System, EuroQol-5 Dimension, and Visual Analog Scale to evaluate symptoms. Subsequently, the Neuropathy Scoring System, EuroQol-5 Dimension, and subjective discomfort improved. Conclusion: The present case report suggests that combined Korean medicine treatment might be an effective treatment for paresthesia and pain with diabetic polyneuropathy. Several follow-up studies should be conducted to clarify the effectiveness of the treatment.

고양이의 내측 및 외측 척수망상로 세포의 전기생리학적 비교연구 (A Comparative Study on the Electrophysiological Properties of Medial and Lateral Spinoreticular Tract Cells in Cats)

  • 이석호;전제열;박춘옥;구용숙;김전;성호경
    • The Korean Journal of Physiology
    • /
    • 제24권1호
    • /
    • pp.181-194
    • /
    • 1990
  • Vasomotor area로 알려져 있던 외측연수망상체는 최근 rostral ventrolateral medulla로 불리 면서 sympathoexcitatory neuron이 집중적으로 분포하는 연수내 부위로서, 체성교감신경반사에 중요한 역할을 하는 것으로 알려지고 있어 이 부위로의 입력정보가 그동안 많은 연구가 되어온 내측 척수망상로 세포와 어떤 차이를 보이는가를 규명하고자 하였다. 1) Medial SRT 세포는 34 cell중 약 60%가 동측으로 향하였으나, lateral SRT cell의 경우 47 cell의 약 60%가 반대측으로 향하였다. 2) 각 군의 세포를 말초자극에 대한 반응성에 따라, LT cell, Deep cell, HT cell및 WDR cell로 나누었으며 유해자극을 전달하는 세포를 HT와 WDR cell이라 하고, 무해자극을 전달하는 세포와 유해자극을 전달하는 세포의 비율로 볼 때, 다른 부위에 비하여 rostral VLM에 유해자극정보가 비교적 많이 전달됨을 볼 수 있었다. 3) 평균 전도 속도는 각 군간에 유의한 차이가 없었으나, Deep cell은 HT cell보다 유의하게 빠른 전도속도를 보였다. 4) Medial SRT 세포는 척수 회백질 내에서 Rexed laminae VII및 VIII에 주로 분포하며, LRN projecting SRT cell의 경우엔 전 lamina에 걸쳐 고루 분포하였다. 이상의 결과는 내측 및 외측 망상체간의 말초 입력 정보의 차이를 보여주고 있으며, 연수 망상체의 세 부위중 특히 rostral ventrolateral medulla로 많은 동통정보가 입력되고 있어 RVLM의 기능중 하나인 체성교감반사의 통합과 연관된 역할을 하리라 기대된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

세 명의 대한민국 제 V형 당원축적근육병(McArdle 병) 환자들의 유전학적 및 임상적 특성 보고 (The Clinical and Genetic Characteristics of Three Korean Patients with Glycogen Storage Disease Type V (McArdle Disease))

  • 이성희;강은구;김윤명;이범희;김구환;유한욱
    • 대한유전성대사질환학회지
    • /
    • 제16권2호
    • /
    • pp.93-101
    • /
    • 2016
  • 목적: McArdle 병은 당원분해의 주요 속도 조절 단계인 당원인산화의 장애로 운동 초기에 적절한 에너지 공급이 이루어지지 않아 운동내성 및 근력약화가 발생하는 상염색체 열성 근육병으로, 저자의 관점 하에 현재까지 보고된 대한민국 McArdle 병은 4례로, 본 논문은 대한민국 McArdle 병 환자를 추가 보고하고 이들의 임상증상 및 유전학적 변이를 밝히고자 한다. 방법: 2006년부터 2011년까지 임상증상과 일반 혈액 및 생화학 검사, 그리고 PYGM 유전자 검사로 확진된 총 3명의 McArdle 병 환자의 전자 차트를 후향적으로 검토하여, 검사 소견, 시행된 운동요법과 약물치료, 그리고 예후를 확인하였다. 돌연변이 분석은 말초 혈액에서 분리한 DNA에서 genomic DNA를 분리하고, primer를이용해PYGM의 20개 exon과 intronic flanking 배열을 증폭한 후 전기영동으로 DNA 염기서열을 분석하였다. 결과: 세 증례의 증상 발생 평균 연령은 $10.33{\pm}4.73$ 세로, 공통적으로 심한 근육통, 근육부종을 동반한 잦은 횡문근융해증, 높은 기저 혈청 크레아틴키나아제과 마이오글로빈 농도, 뚜렷하지 않은 second wind phenomenon을 보였다. 근육생검 결과, 증례 1은 정상소견을 보였으나, 증례 2는 subsarcolemmal 공간 내 당원침착과 적색열의 퇴행 및 괴사, 증례 3은 periodic acid Schiff stain에 염색되는 물질을 갖는 공포와 내핵을 포함한 근섬유 소견을 보여 당원축적증에 합당한 양상을 보였다. 결론: PYGM 염기서열 분석 결과에서는 증례 1에서 $p.Arg50^*$;p.Trp798Arg, 증례 2에서 $p.Arg50^*$;p.Glu779 del, 증례 3에서 $p.Asp511Thrfs^*28$;p.Phe710 del 복합 이형 접합자 돌연변이를 보였다.

  • PDF

청소년기 당뇨병 환자의 자율신경계 합병증에 관한 연구 (Autonomic Neuropathy in Adolescents with Diabetes Mellitus)

  • 유은경;안선영;김덕희
    • Clinical and Experimental Pediatrics
    • /
    • 제46권6호
    • /
    • pp.585-590
    • /
    • 2003
  • 목 적 : 심혈관계 자율신경 기능이상은 청소년기 당뇨병 환자의 7.7-28%에서 동반되며, 당뇨병성 자율신경병증은 심장 교감 신경계 이상으로 인한 돌발성 부정맥 및 돌연사를 초래할 수 있는 것으로 보고되었다. 본 연구는 소아 및 청소년기 당뇨병 환자에서 심혈관계 자율신경 기능이상의 빈도 및 이에 영향을 미치는 인자들을 파악하여 당뇨병성 자율신경병증의 조기진단 및 치료에 도움이 되고자 시행하였다. 방 법 : 8-26세의 1형 당뇨병 환자 80명(남자 27명, 여자 53명)과 2형 당뇨병 환자 12명(남자 4명, 여자 8명)을 대상으로, 발살바 동작시 R-R 간격의 변화(발살바 비), 심호흡시 심박수의 변화, 기립시 R-R 간격의 변화(30 : 15 비), 기립성 저혈압의 4가지 항목에 대하여 검사를 시행하여 환자의 연령, 유병기간, 당화혈색소, 소변 알부민 배설량, 신경전달속도 이상 및 당뇨병성 망막증 유무와의 연관성을 분석하였다. 결 과 : 검사 당시 연령 및 평균 유병기간은 1형과 2형 당뇨병 환자간에 의미있는 차이가 없었으나, 당뇨병의 발병연령은 2형에서 더 높았다. 체질량지수는 1형에 비해 2형에서 의미있게 높았으며, 혈압 및 당화혈색소는 두 군간에 차이가 없었다. 1형 당뇨병 환자의 22.5%에서 조기, 8.7%에서 중등도, 1.3%에서 심한 자율신경병증에 해당하였으며, 2형의 경우 16.7%에서는 조기, 8.3%에서 중등도, 8.3%에서 심한 자율신경병증에 해당하였다. 전체적으로, 심혈관계 자율신경 기능 이상은 1형의 32.5%에서, 2형의 33.3% 에서 나타나 빈도에 있어서 두 군간에 차이는 보이지 않았다. 1형에서는 발살바 비와 유병기간 간에 의미있는 상관관계가 있었으며, 2형에서는 발살바 비와 연령, 심호흡시 심박수 변화와 당화혈색소, 그리고 기립성 저혈압과 유병기간 간에 의미있는 상관관계가 관찰되었다. 1형과 2형 당뇨병 환자 전체를 대상으로 시행한 로지스틱 회귀분석상, 연령(OR=1.133(1.003-1.279), P<0.05) 및 유병기간(OR=1.148(1.009-1.307), P<0.05)만이 자율신경 기능 이상의 의미있는 예측인자로 나타났으며, 당화혈색소, 혈압, 소변 알부민 배설량, 신경전달속도 이상 및 당뇨병성 망막증 유무와는 관련이 없었다. 검사항목 중 발살바 비는 31.5%의 환자에서, 심호흡시 심박수의 변화는 41.3%의 환자에서 경계역 또는 이상소견을 보인 반면, 30 : 15 비 및 혈압변화는 각각 14.1%, 9.8%에서 경계역 또는 이상소견을 보였다. 발살바 비(OR=0.001(0.000-0.083), P<0.01)와 심호흡시 심박수의 변화(OR=0.840(0.754-0.934), P<0.01)는 자율신경 기능이상 유무에 의미있게 영향을 미쳤으나, 30 : 15 비 및 기립성 저혈압은 영향을 미치지 못하였다. 결 론 : 심혈관계 자율신경 기능이상은 소아 및 청소년 당뇨병 환자의 32.6%에서 동반되었으며, 중등도 이상의 뚜렷한 자율신경 기능이상도 10.8%에서 관찰되었다. 혈당 조절이 양호한 환자에서도 자율신경계 합병증의 가능성은 배제할 수 없으며 연령 및 유병기간이 증가할수록 그 위험은 더욱 증가하였다. 소아 및 청소년기 당뇨병 환자에서 자율신경 기능검사시, 발살바 비와 심호흡시 심박수의 변화가 가장 유용한 검사 항목으로 사료된다.

고양이의 납중독에 관한 실험적 연구 1. 임상증상 및 실험실적 평가 (Experimental Studies on Lead Toxicity in Domestic Cats 1. Symptomatology and Diagnostic Laboratory Parameters)

  • 홍순호;한홍율
    • 한국임상수의학회지
    • /
    • 제10권1호
    • /
    • pp.111-130
    • /
    • 1993
  • 고양이에서 납의 중독량을 결정하고 행동과 임상병리학적인 변화를 밝히고, 납 투여용량과 혈중 납농도와의 관계를 규명하기 위하여 42마리의 고양이를 대상으로 체중에 따라 0(대조군), 10, 100(저용량), 1000, 2000, 4000(고용량) ppm의 lead acetate를 경구적으로 투여하여 납독성을 평가하였다. 고투여용량(1000, 2000, 4000ppm)을 투여한 어떤 고양이는 분출성 구토, 활동항진 그리고 발작을 보였다. 모든 실험군에서 성장율은 변화가 없었다. 고양이의 정상 혈중 납농도는 사람, 개 그리고 소의 혈중 납농도 보다 낮았다. 고양이에서 준임상형 납중독의 혈중 납농도는 3~20$\mu\textrm{g}$/100$m\ell$이었고, 임상형 납중독의 혈중 납농도는 20~l20$\mu\textrm{g}$/100$m\ell$이었다. Zinc protoporphyrin 농도는 납 투여용량에 비례하였으며 50$\mu\textrm{g}$/100$m\ell$ 이상으로 ZPP농도가 유의성 있게 증가하는 경우는 임상형의 납중독을 의미하였다. Aminolevulinic acid dehydratase는 모든 납 투여용량에 역비례 관계를 보였고, 고양이의 납노출에 대한 유용한 진단적 지표로 나타났다. 오줌의 aminolevulinic acid 농도는 대개 납투여용량에 따라서 증가하지만 측정치는 개체에 따라 다양하였다. 피모의 납농도는 납투여용량에 따라 비례적으로 증가하였다. 최소한 고용량에서 납은 PMN세포와 단핵구의 화학주성을 억제하는 것으로 나타났다. 헤모글로빈, 적혈구, 백혈구, 호중구, 임파구, 단핵구 그리고 호산구에서는 투여용량에 대한 반응이 일정하게 관찰되지 않았고 또한 총단백, 혈장단백, BUN그리고 ALT치에서의 용량에 따른 일정한 변화가 없었다. 망상적혈구수는 대부분의 납투여용량수준에서 유의성 있게 증가하지 않았기 때문에 고양이 납중독의 진단적 가치는 거의 없었다. 신경전달속도의 유의성 있는 변화가 없는 것으로 보아 납섭취로 인한 대상성 탈여(Segmental demyelination)는 없는 것으로 생각된다. 고양이의 치사량은 체중 kg당 60~150mg이었다. 납중독 진단에 신뢰할 수 있는 파라미터는 혈중 납농도, ZPP. ALAD 그리고 피모의 납농도이었다.

  • PDF

샤르코-마리-투스병 1A형(CMT1A)의 가족내 표현형적 이질성과 MIR149 SNP에 대한 연관성 연구 (Association between MIR149 SNPs and Intrafamilial Phenotypic Variations of Charcot-Marie-Tooth Disease Type 1A)

  • 최유진;이아진;남수현;최병옥;정기화
    • 생명과학회지
    • /
    • 제29권7호
    • /
    • pp.800-808
    • /
    • 2019
  • 샤르코-마리-투스병(Charcot-Marie-Tooth disease: CMT)은 희귀 말초신경병의 그룹으로, 진행성 근육 약화 및 위축, 감각 소실, 상지 및 하지의 무반사 증상을 나타낸다. CMT1A는 PMP22 유전자가 존재하는 17p12 지역의 직렬 중복으로 발병하는데, 유전자형-표현형의 상관성이 느슨하여 2차 유전적 요인의 존재를 암시한다. 최근 MIR149의 rs71428439 (n.83A>G)와 rs2292832 (n.86T>C) 변이가 후기 발병 및 가벼운 증상의 표현형과 연관성이 있는 것으로 보고되었다. 본 연구는 CMT1A 기계내 임상적 표현형의 이질성이 MIR149의 SNP과 연관성이 있는지를 규명하기 위해 수행하였으며, 조사 대상으로는 가계내 표현형의 차이가 심한 6 CMT1A 대 가계를 대상으로 하였다. 그 결과, MIR149의 rs71428439와 s2292832 유전자형은 가족내의 늦은 발병과 약한 중증도의 유전적 요인으로 작용할 수 있음을 제시하였다. 특히, AG+GG (n.83A>G)와 TC+CC 유전자형(n.86T>C)은 발병 시기가 늦고 경미한 증상을 보였다. 운동신경 전기전도도(MNCV)는 MIR149 유전형과 연관이 없는 것으로 보였는데, 이러한 결과는 이전 연구와 일치한다. 따라서 본 연구는 MIR149의 rs71428439와 rs2292832 변이는 CMT1A 가계내 표현형적 이질성의 원인 중 하나로 작용할 가능성을 제시한다. 본 연구는 가계 내 증상의 차이가 심한 6 대가족을 사용하여 연구를 수행한 것은 의미가 크다고 여겨지며, 이런 결과는 CMT1A 환자의 분자 진단과 치료에 도움을 줄 수 있을 것으로 기대된다.