• Title/Summary/Keyword: Nero

Search Result 22, Processing Time 0.018 seconds

Study of Factors Controlling Exposure Dose and Image Quality of C-arm in Operation Room according to Detector Size of It (Mainly L-Spine AP Study) (수술 중 C-Arm Neutral AP 검사 시 조절인자에 따른 피폭선량 및 화질비교(L-Spine AP검사를 기준으로))

  • CHOI, Sung-Hyun;JO, Hwang-Woo;Dong, Kyung-Rae;Chung, Woon-Kwan;Choi, Eun-Jin;Song, Ha-jin
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: Time of operation has been reduced and accuracy of operation has been improved since C-arm, which offer real-time image of patient, was introduced in operation room. However, because of the contamination of patient, C-arm could not be used more appropriately. Therefore, this study is to know factors of controlling exposure dose, image quality and the exposed dose of health professional in operation room. Materials and methods: Height of Wilson frame (bed for operation) was fixed at 130 cm. Then, Model 76-2 Phantom, which was set by assembling manual of Fluke Company, was set on the bed. Head/Spine Fluoroscopy AEC mode was set for exposure condition. According to detector size of C-arm, the absorbed dose per min was measured in the 7 steps OFD (cm) from 10 cm to 40 cm (10, 15, 20, 25, 30, 35, 40 cm). In each step of OFD, the absorbed dose per min of same diameter of collimation was measured. Moreover, using Nero MAX Model 8000, exposure dose per min was measured according to 3 step of distance from detector (20 cm, 60 cm, 100 cm). Finally, resolution was measured by CDRH Disc Phantom and magnification of each OFD was measured by aluminum stick bar. Result: According to detector size of C-arm, difference of absorbed dose shows that the dose of 20 cm OFD is 1.750 times higher than the dose of 40 cm OFD. It means that the C-arm, which has smaller size of detector, shows the bigger difference of absorbed dose per min (p<0.05). In the difference of absorbed dose in the same step of OFD (from 20 cm to 40 cm), the absorbed dose of 9 inch detect or C-arm was 1.370 times higher than 12 inch' s (p<0.05). When OFD was set to 20 cm OFD, the absorbed dose of non-collimation case was approximately 0.816 times lower than the absorbed dose of collimation cases (p<0.05). When the distance was 20 cm from detector, exposed does includes first-ray and scatter-ray. When the distance was 60 cm and 100 cm from detector, exposed does includes just scatter-ray. So, there was the 2.200 times difference of absorbed does. Finally, when OFD was increased, spatial resolution was 4 to 5 step was increased. However, low contrast resolution was not relative. Moreover, there was 1.363 times difference of magnification (p<0.05). Conclusion: When C-Arm is used, avoiding contamination of patient is more important factor than reducing exposed dose of health professional in operation room. Just controlling exposure time is just way to reduce the exposed does of workers. However, in the case, non-probability influence could be occurred. Therefore, this study proved that the exposed dose will be reduced if the factors such as using small detector size of C-arm, setting OFD from 20 cm to 25 cm and non-collimating. Moreover, dose management of C-arm in the non-interesting area will be considered additionally.

SF Movie Star Trek Series and the Motif of Time Travel (SF영화 <스타트랙> 시리즈와 시간여행의 모티프)

  • Noh, Shi-Hun
    • Journal of Popular Narrative
    • /
    • v.25 no.1
    • /
    • pp.165-191
    • /
    • 2019
  • The purpose of this article is to elucidate why the motif of time travel is repeated in the science fiction narrative by examining the functions of this motif in the SF movie series of Star Trek in its narrative and non-narrative aspects. Star Trek IV: The Voyage Home (1986) aims to attract the audience's interest in the story through the use of plausible time travel in the form of the slingshot effect which causes the spacecraft to fly at very fast speeds around an astronomical object. The movie also touches upon the predestination paradox that arises from a change of history in which it describes a formula of transparent aluminum that did not exist at the time. The film also serves as an evocation of the ideology of ecology by including humpback whales in the central narrative and responding to the real issue of the whale protection movement of the times. Star Track VIII: First Contact (1996) intends to interest the audience in the narrative with the warp drive, a virtual device that enables travel at speeds faster than that of light and a signature visual of Star Trek, at the time of its birth through time travel. The film emphasizes the continuation of peaceful efforts by warning the destruction of humanity that nuclear war can bring. It tackles with the view of pacifism and idealism by stressing the importance of cooperation between countries in the real world by making the audience anticipate the creation of the United Federation of Planets through encounters with the extraterrestrial. Star Trek: The Beginning (2009) improves interest through the idea of time travel to the past, this time using a black hole and the parallel universe created thereby. The parallel universe functions as a reboot, allowing a new story to be created on an alternate timeline while maintaining the original storyline. In addition, this film repeats the themes pacifism and idealism shown in the 1996 film through the confrontation between Spock (and the Starfleet) and Nero, the destruction of the Vulcan and the Romulus, and the cooperation of humans and Vulcans. Eventually, time travel in three Star Trek films has the function of maximizing the audience's interest in the story and allowing it to develop freely as a narrative tool. It also functions as an ideal solution for commenting on current problems in the non-narrative aspect. The significance of this paper is to stress the possibility that the motif of time travel in SF narrative will evolve as it continues to repeat in different forms as mentioned above.