• Title/Summary/Keyword: Negative pressure wave

Search Result 40, Processing Time 0.029 seconds

Effect of High Pressure on Polarographic Parameters of Metal Complex Ion (金屬錯이온의 폴라로그래피的 파라미터에 미치는 壓力의 影響)

  • Heung Lark Lee;Zun Ung Bae;Jong Hoon Yun
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.444-451
    • /
    • 1987
  • The dependence of polarographic parameters on the pressure for the reduction of copper(II), cadmium(II), and zinc(II) complex ions with ethylenediamine, propylenediamine, and diethylenetriamine has been studied. In this study the dropping mercury electrode, the mercury pool electrode, and helix type of platinum wire were used as the working, the reference, and the auxilary electrode, respectively. With increasing the pressure from 1 atmosphere to 1,500 atmospheres, the reduction half-wave potentials of metal complex ions are shifted to the negative values and the diffusion currents become considerably larger, in keeping with the theory on the change of the physical properties of the electrolytic solution such as the density, the viscosity, the dielectric constant, and the electrical conductance, etc. The slope values of the logarithmic plot are increased with increasing the pressure, which indicates the more irreversible reduction. The temperature coefficients of diffusion current observed over the range of the temperature from 25$^{\circ}$C to 35$^{\circ}$C are about two percentage with increasing the pressure, therefore the polarographic reduction under the high pressure is controlled by diffusion. The linear relationships between diffusion current and concentration of metal complex ions are established over all pressure range.

  • PDF

Effect of High Pressure on Polarographic Parameters of Metal Ions (金屬이온의 폴라로그래프法的 파라미터에 미치는 壓力의 影響)

  • Heung Laek Lee;Zun Ung Bae;Jong Hoon Yun
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.315-322
    • /
    • 1984
  • The dependence of polarographic parameters on the pressure for the reduction of In(III), Cr(III), Cd(II), Pb(II), Mn(II), Co(II), Tl(I) in 0.1M KCl aqueous solution at the dropping mercury electrode have been discussed. In this experiment the temperature varied from $25^{\circ}C\;to\;35^{\circ}C$ and the pressure ranges from 1 atmosphere to 1,800 atmospheres. By increasing the pressure the reduction half-wave potentials of all metal ions are shifted markedly to more negative values and the diffusion currents of all metal ions become considerably larger. The slope of the linear relationship of E vs. log[$\frac{id-i)}{i}$] become much larger with increase in pressure, which indicates more irreversible reduction. The temperature coefficient observed over the range of the temperature from $25^{\circ}C\;to\;35^{\circ}C$ are not sensitive with increase in pressure.

  • PDF

Local dynamic buckling of FPSO steel catenary riser by coupled time-domain simulations

  • Eom, T.S.;Kim, M.H.;Bae, Y.H.;Cifuentes, C.
    • Ocean Systems Engineering
    • /
    • v.4 no.3
    • /
    • pp.215-241
    • /
    • 2014
  • Steel catenary riser (SCR) is a popular/economical solution for the oil/gas production in deep and ultra-deep water. The behavioral characteristics of SCR have a high correlation with the motion of floating production facility at its survival and operational environments. When large motions of surface floaters occur, such as FPSO in 100-yr storm case, they can cause unacceptable negative tension on SCR near TDZ (touch down zone) and the corresponding elastic deflection can be large due to local dynamic buckling. The generation, propagation, and decay of the elastic wave are also affected by SCR and seabed soil interaction effects. The temporary local dynamic buckling vanishes with the recovery of tension on SCR with the upheaval motion of surface floater. Unlike larger-scale, an-order-of-magnitude longer period global buckling driven by heat and pressure variations in subsea pipelines, the sub-critical local dynamic buckling of SCR is motion-driven and short cycled, which, however, can lead to permanent structural damage when the resulting stress is greatly amplified beyond the elastic limit. The phenomenon is extensively investigated in this paper by using the vessel-mooring-riser coupled dynamic analysis program. It is found that the moment of large downward heave motion at the farthest-horizontal-offset position is the most dangerous for the local dynamic buckling.

V-t Characteristics in $SF_6-N_2$ Mixtures for Transient Impulse Voltages ($SF_6-N_2$ 혼합가스에서 과도임펄스전압에 대한 V-t특성)

  • Lee, Bok-Hui;Lee, Gyeong-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.456-465
    • /
    • 2001
  • In this paper, breakdown voltages in $SF_6-N_2$ mixtures were experimentally investigated to understand characteristics of dielectric strength and physical phenomena in nonuniform field disturbed by a needle shape protrusion. The test voltages are the lightning impulse$(\pm1.2/44 \mus)$ and the damped oscillatory impulse$(\pm400 ns / 0.83 MHz)$ voltages which can be occurred by the operation of disconnecting switches in gas-insulated switchgears(GIS). The effects of the polarity and wave shape of the test voltages, and the gas pressure on the V-t characteristics were in detail examined. The V-t characteristic curves were measured in different two ways : (1) one is the method by taking the maximum voltage recorded at or prior to breakdown against the time to breakdown, that is, the Procedures recommended in IEC 60060-1, (2) the other is the method by taking the voltage at the instant of chopping against the time to breakdown. As a result, the V-t characteristics of $SF_6-N_2$ mixtures in nonuniform electric field were significantly affected by the polarity and wave shape of the applied voltages. The positive breakdown voltages resulted in lower breakdown voltages in the time ranges considered, and the V-t curves for the negative oscillatory impulse voltage were extended over the longer time range. For the lightning impulse voltages, the V-t curves obtained by IEC Pub. 60060-1 were nearly same with the V-t curves obtained by the voltage at the instant of chopping against the time to breakdown. It is clear that the actual breakdown voltages were much lower than the maximum voltages appearing at or prior to breakdown because of the displacement current produced as a result of the dV/dt during the oscillatory transient voltage app1ication. The scattering of the negative actual breakdown voltages was much larger than that of the positive.

  • PDF

Cavitation Suppression Effects by the Modification of the Spectral Characteristics of High Intensity Focused Ultrasound (고강도 집속형 초음파의 주파수 성분 특성에 따른 공동 현상 억제 효과)

  • 최민주
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.68-77
    • /
    • 1999
  • The paper looked into the effects of the spectral properties (waveform) of the high intensity focused ultrasound on suppression of the ultrasonic cavitation. Three different types of ultrasound were considered in the study, which were sinusoidal (1 MHz, 5 MPa), frequency modulated (from 1 MHz to 6 MHz for 10 ㎲, 5 MPa), asymmetrically shocked (fundamental frequency 1 MHz, peak positive pressure 12 MPa, peak negative pressure -4 MPa). The temporal response of an air bubble in water initially 1 ㎛ in radius to each type of the ultrasound was predicted using Gilmore bubble dynamic model and Church's rectified gas diffusion equation. It was shown that the radially pulsating amplitude of the bubble was greatly reduced for the frequency modulated wave and was little decreased for the shock wave, compared to the case that the bubble was exposed to the sinusoidal wave. It is interesting that the bubble response to the frequency modulated wave remains similar when the frequency component of the modulated ultrasound is beyond the bubble resonant frequency 3 MHz. This implies that, although the ultrasound is modulated up to 3MHz rather than up to the present 6 MHz, it is likely to produce similar cavitation suppression effects. In practice, it means that a typical narrow band ultrasonic transducer can be taken to generate an appropriate frequency modulated ultrasound to reduce cavitation activity. The present study indicates that ultrasonic cavitation may be suppressed to some extent by a proper spectral modification of high intensity ultrasound.

  • PDF

Change of Somatosensory Evoked Field Potential according to the Severity of Hydrocephalus in Kaolin-induced Hydrocephalus of Rats (수두증 흰쥐 모델에서 수두증 정도에 따른 체성 감각 유발 장전위의 변화)

  • Kim, Dong-Seok;Lee, Kwang-Soo;Park, Yong-Goo;Kim, Se-Hyuk;Choi, Joong-Uhn;Lee, Bae-Hwan;Ryou, Jae-Wook;Zhao, Chun-Zhi
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.5-14
    • /
    • 2000
  • Objective : Somatosensory evoked potential(SSEP) has been known to be a good method for evaluating brain stem function, but it is not sufficient to check the fine changes of cortical functions. A fine change of cortical function can be expressed with somatosensory evoked cortical field potential(SSEFP) rather than general SSEP. To confirm the usefulness of SSEFP for evaluating the cortical function, the authors simultaneously measured SSEFP and the intracranial pressure-volume index(PVI) in kaolin-induced hydrocephalic rats. Method : Hydrocephalus was induced with injection of 0.1ml kaolin-suspended solution into the cisterna magna in 60 Sprague-Dawley rats. The authors measured PVI and SSEFP 1 week after injection of kaolin-suspended solution. To evaluate the severity of induced hydrocephalus, we measured the transverse diameter of the lateral ventricle on the coronal slice of the rat brain 0.40mm posterior to the bregma. Result : The typical wave form of SSEFP in control rats showed a negative-positive complex wave at early latency. In SSEFP of normal rats, N0 is 10.0 msec, N1 15.3 msec, P1 31.2 msec and N1-P1 amplitude $15.4{\mu}V$. As hydrocephalus progressed, the peak latency of N1 and P1 were delayed. In mild hydrocephalus, negative peak waves were split. The N1-P1 amplitude was decreased only in severe hydrocephalus. The changes of the characteristics of SSEFP according to the severity of hydrocephalus were well correlated with the changes of PVI. Shunting normalized the characteristics of SSEFP in relation to ventricular sizes and PVI in hydrocephalic rats. Conclusion : SSEFP may be useful for evaluating the impairment of cortical function in hydrocephalus.

  • PDF

Wall Shear Stress Distribution in the Abdominal Aortic Bifurcation : Influence of wall Motion, Impedance Phase Angle, and non-Newtonian fluid (복부대동맥 분기관에서의 벽면전단응력 분포 벽면운동과 임피던스 페이즈 앵글과 비뉴턴유체의 영향)

  • Choi J.H.;Kim C.J.;Lee C.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.261-271
    • /
    • 2000
  • The present study investigated flow dynamics of a two-dimensional abdominal aortic bifurcation model under sinusoidal flow conditions considering wall motion. impedance phase angle(time delay between pressure and flow waveforms), and non-Newtonian fluid using computational fluid dynamics. The wall shear stress showed large variations in the bifurcated region and the wall motion reduced amplitude of wall shear stress significantly. As the impedance phase angle was changed to more negative values, the mean wall shear stress (time-averaged) decreased while the amplitude (oscillatory) of wall shear stress increased. At the curvature site on the outer wall where the mean wall shear stress approached zero. influence of the phase angle was relatively large. The mean wall shear stress decreased by $50\%$ in the $-90^{\circ}$ phase angle (flow wave advanced pressure wave by a quarter period) compared to the $0^{\circ}$ phase angle while the amplitude of wall shear stress increased by $15\%$. Therefore, hypertensive patients who tend to have large negative phase angles become more vulnerable to atherosclerosis according to the low and oscillatory shear stress theory because of the reduced mean and the increased oscillatory wall shear stresses. Non-Newtonian characteristics of fluid substantially increased the mean wall shear stress resulting in a less vulnerable state to atherosclerosis.

  • PDF

Dielectric Characteristics of Gaseous $SF_6$ for Impulse Voltages in Presence of a Metallic Particle in GIS (가스절연개폐장치에 있어서 금속입자 존재시 임펄스전압에 대한 $SF_6$가스의 절연특성)

  • 이복희;이경옥;이창준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • This paper deals with the dielectric characteristics of $SF_6$ gas gap stressed by $\pm$1.2/44[$mutextrm{s}$] non-oscillating impulse and $\pm$0.4[$mutextrm{s}$]/1.14[MHz] oscillating impulse voltages in the presence of a needle-shape metallic particle in gas-insulated switchgear(GIS). Breakdown voltage-time (V-t) and breakdown voltage-gas pressure (V-p) characteristics were investigated and discussed. The experiments were carried out under highly inhomogeneous field geometry with a needle protrusion whose length and radius are 10[mm] and 0.5[mm], respectively. The gas pressure ranges from 0.1 to 0.5[㎫]. As a result, it was found that the electrical breakdown for both the positive and negative polarity develops with steplike pulses in leader mechanism, When subjected to the positive oscillating impulse voltage, the minimum breakdown voltages appeared in all the gas pressure ranges and the V-t curves have a pronounced upturning at short times to breakdown and give a little dependence of the gas pressure. On the other hand, in the case of the negative polarity the dependence of the V-t and V-p characteristics on the wave shape of the applied voltages is known to be appreciable.

  • PDF

The Electronic and Magnetic Properties of Fe Overlayers on W(110) (W(110)위에 성장한 Fe 웃층의 전자 및 자기적 성질)

  • ;;A. J. Freeman
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.1-8
    • /
    • 1991
  • The electronic and magnetic structure of Fe overlayers on W(110) is determined by means of the all-electron local spin density full potential linearized augmented plane wave (FLAPW) method with a single slab approach. Charge and spin densities, magnetic moments, contact hyperfine fields, and layer projected density of states (LDOS) are presented. For bilayer Fe coverage, we find magnetic moments to be 2.90 and 2.30 ${\mu}_B$ for the surface and subsurface Fe layers, respectively, corresponding to a 18% enhancement of the total magnetization compared with the calculated bulk value (2.22${\mu}_B$);For monolayer coverage the moment is 2.56 ${\mu}_B$ which is enhanced by 16% compared to bulk. Unusual changes in the magnetic hyperfine interaction are found in going from a monolayer to a bilayer coverage. Comparison of the results to the theoretical ones of the clean Fe(110) to discuss the hybridization and the negative pressure effects. We discuss our results by comparing them to experimental results.

  • PDF

Seismic Influence on Subsea Pipeline Stresses

  • Choi, Byoung-Yeol;Lee, Sang-Gil;Kim, Jin-Kwang;Oh, Jin-Soo
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.3 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • The safety analysis of an earthquake is carried out during the operation of a subsea pipeline and an onshore pipeline. Several cases are proposed for consideration. In the case of a buried pipeline, permanent ground deformation by the earthquake and an increase of internal pressure by the acceleration of the earthquake should be considered. In the case of a subsea pipeline, a bending moment is caused by liquefaction of the backfill material on a trenched seabed, etc., which results in a high bending moment of the buried pipeline. The bending moment causes the collapse of the subsea pipeline or a leak of crude oil or gas, which results in economic loss due to enormous environmental contamination and social economic loss owing to operation functional failure. Thus, in order to prevent economic loss and operation loss, structurally sensitive design with regard to seismic characteristics must be performed in the buried pipeline in advance, and the negative impact on the buried pipeline must be minimized by conducting a thorough analysis on the seabed and backfilling material selection. Moreover, it is proposed to consider the selection of material properties for the buried pipeline. A more economical review is also required for detailed study.