• Title/Summary/Keyword: Negative power

Search Result 1,616, Processing Time 0.033 seconds

Relationship between Thoughts and Anxiety about Nuclear Power among Busan Residents (일부 부산지역 주민의 원자력에 대한 생각과 불안감의 관계)

  • Park, Jee Eun;Lee, Samyol;Baek, Cheol-Ha;Kim, Soo Jeong
    • The Korean Journal of Health Service Management
    • /
    • v.13 no.3
    • /
    • pp.137-147
    • /
    • 2019
  • Objectives: This study aimed to identify the relationship between thoughts and psychological anxiety about nuclear power among Busan residents. Methods: Convenience sampling was used for this cross-sectional survey conducted from February 13 to 14, 2016. A total of 520 residents participated in the study and completed a self-administered questionnaire. Results: We found a significant association between negative thoughts and psychological anxiety about nuclear power. People older than 60 years (odds ratio (OR) 2.53, 95% confidence interval (CI) 1.41-4.54), who feared the possibility of radiation accidents (OR 1.75, 95% CI 1.17-2.62), considered nuclear power plants unsafe (OR 1.94, 95% CI 1.10-3.40), and believed the Gori nuclear power plant in Busan must be shut down (OR 1.84, 95% CI 1.22-2.79), had the highest anxiety about radiation exposure. Conclusions: The authors suggest the need for the formulation of a policy to provide people with precise information on nuclear power to increase their understanding and help eliminate unfounded negative thoughts. Furthermore, policy decisions about nuclear power must be based on social consensus.

Improved DPC Strategy of Grid-connected Inverters under Unbalanced and Harmonic Grid Conditions

  • Shen, Yongbo;Nian, Heng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.169-175
    • /
    • 2014
  • This paper presents an improved direct power control (DPC) strategy for grid-connected voltage source inverter (VSI) under unbalanced and harmonic grid voltage conditions. Based on the mathematic model of VSI with the negative sequence, 5th and 7th harmonic voltage components consideration, a PI controller is used in the proposed DPC strategy to achieve the average output power regulation. Furthermore, vector PI controller with the resonant frequency tuned at the two times and six times grid fundamental frequency is adopted to regulate both negative and harmonic components, and then two alternative targets of the balanced/sinusoidal current and smooth active/reactive output power can be achieved. Finally, simulation results based on MATLAB validate the availability of the proposed DPC strategy.

VPI-based Control Strategy for a Transformerless MMC-HVDC System Under Unbalanced Grid Conditions

  • Kim, Si-Hwan;Kim, June-Sung;Kim, Rae-Young;Cho, Jin-Tae;Kim, Seok-Woong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2319-2328
    • /
    • 2018
  • This paper introduces a control method for a transformerless MMC-HVDC system. The proposed method can effectively control the grid currents of the MMC-HVDC system under unbalanced grid conditions such as a single line-to-ground fault. The proposed method controls the currents of the positive sequence component and the negative sequence component without separating algorithms. Therefore, complicated calculations for extracting the positive sequence and the negative sequence component are not required. In addition, a control method to regulate a zero sequence component current under unbalanced grid conditions in the transformerless MMC-HVDC system is also proposed. The validity of the proposed method is verified through PSCAD/EMTDC simulation.

Energy Saving in Boom Motion of Excavators using IMV (IMV를 사용한 유압굴삭기 붐 동작의 에너지 절감)

  • Huh, Jun Young
    • Journal of Drive and Control
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2017
  • Energy consumption of conventional hydraulic excavators controlled by MCV is considerable when negative load is applied because the meter orifice and meter-out orifice are machined in one spool. Therefore, IMV is introduced to save energy use of hydraulic excavators, but existing hydraulic excavators have various advantages so it is difficult to make a clear comparison. In this study, we compare the use of an existing MCV excavator that has many advantages such as negative control, and IMV for boom up and down operation, and if IMV is used to save energy, we will examine the cause. If possible, for comparability under the same conditions, both systems use pressure balance valves to minimize power consumption when not using power in the actuator. The orifice area at each notch of each valve is calculated, and energy saving is verified by comparing the two systems through simulation.

Reducing Current Distortion in Indirect Matrix Converters Operating in Boost Mode under Unbalanced Input Conditions

  • Choi, Dongho;Bak, Yeongsu;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1142-1152
    • /
    • 2019
  • This paper presents a control method for reducing the current distortion in an indirect matrix converter (IMC) operating in boost mode under unbalanced input conditions. IMCs operating in boost mode are useful in distributed generation (DG) systems. They are connected with renewable energy systems (RESs) and the grid to transmit the power generated by the RES. However, under unbalanced voltage conditions of the RES, which is connected with the input stage of the IMC operating in boost mode, the input-output currents are distorted. In particular, the output current distortions cause a ripple of the power, which is transferred to the grid. This aggravates the reliability and stability of the DG system. Therefore, in this paper, a control method using positive/negative sequence voltages and currents is proposed for reducing the current distortion of both side in IMCs operating in boost mode. Simulation and experimental results have been presented to validate effectiveness of the proposed control method.

Flexible Voltage Support Control with Imbalance Mitigation Capability for Inverter-Based Distributed Generation Power Plants under Grid Faults

  • Wang, Yuewu;Yang, Ping;Xu, Zhirong
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1551-1564
    • /
    • 2016
  • The high penetration level of inverter-based distributed generation (DG) power plants is challenging the low-voltage ride-through requirements, especially under unbalanced voltage sags. Recently, a flexible injection of both positive- (PS) and negative-sequence (NS) reactive currents has been suggested for the next generation of grid codes. This can enhance the ancillary services for voltage support at the point of common coupling (PCC). In light of this, considering distant grid faults that occur in a mainly inductive grid, this paper proposes a complete voltage support control scheme for the interface inverters of medium or high-rated DG power plants. The first contribution is the development of a reactive current reference generator combining PS and NS, with a feature to increase the PS voltage and simultaneously decrease the NS voltage, to mitigate voltage imbalance. The second contribution is the design of a voltage support control loop with two flexible PCC voltage set points, which can ensure continuous operation within the limits required in grid codes. In addition, a current saturation strategy is also considered for deep voltage sags to avoid overcurrent protection. Finally, simulation and experimental results are presented to validate the effectiveness of the proposed control scheme.

Reactivity balance for a soluble boron-free small modular reactor

  • van der Merwe, Lezani;Hah, Chang Joo
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.648-653
    • /
    • 2018
  • Elimination of soluble boron from reactor design eliminates boron-induced reactivity accidents and leads to a more negative moderator temperature coefficient. However, a large negative moderator temperature coefficient can lead to large reactivity feedback that could allow the reactor to return to power when it cools down from hot full power to cold zero power. In soluble boron-free small modular reactor (SMR) design, only control rods are available to control such rapid core transient. The purpose of this study is to investigate whether an SMR would have enough control rod worth to compensate for large reactivity feedback. The investigation begins with classification of reactivity and completes an analysis of the reactivity balance in each reactor state for the SMR model. The control rod worth requirement obtained from the reactivity balance is a minimum control rod worth to maintain the reactor critical during the whole cycle. The minimum available rod worth must be larger than the control rod worth requirement to manipulate the reactor safely in each reactor state. It is found that the SMR does have enough control rod worth available during rapid transient to maintain the SMR at subcritical below k-effectives of 0.99 for both hot zero power and cold zero power.

Analysis and Control of Instantaneous Voltage Compensator Using New Phase Angle Detection Method Synchronized by Positive Sequence of Unbalanced 3-Phase Source (3상 불평형 전원 시스템의 새로운 위상각 검출기법을 이용한 순간전압보상기의 해석 및 제어)

  • 이승요;고재석;목형수;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.275-284
    • /
    • 1999
  • Unbalanced source voltage in the 3-phase power system is decomposed into positive, negative and zero sequence c components. Also, assuming there is no neutral path in the system, the zero sequence component is not shown on the l load side. Therefore, in the unbalanced power system without neutral path. it is possible to provide balanced voltage to t the load side by compensating negative sequence component and also to regulate the voltage amplitude by controlling t the positive sequence component. In addition, the symmetrical components due to voltage unbalance can be effectively d detected on the synchronous reference frame by using dlongleftarrowq transformation. In this paper, an algorithm not only c compensating unbalanced source voltage by canceling the negative sequence component on the synchronous reference f frame but also maintaining load voltages constantly is proposed. Also a novel method for phase angle detection s synchronized by positive sequence component under unbalanced source voltage is suggested and this detected phase a angle is used for d-q transformation. The performances and characteristics of the proposed compensating system are a analyzed by simulation and verified through experimental results.

  • PDF

Improvement of the Characteristics of Feedforward Power Amplifier using Negative Feedback method (Feedback을 첨가한 IMT-2000용 l0W급 Feedforward 선형 전력 증폭기의 설계 및 제작)

  • 류병하;장중호;김성민;최현철
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.345-348
    • /
    • 2000
  • In this paper, A Feedforward Linear Power Amplifier for IMT-2000 which IMD characteristics was improved was designed and fabricated. To improve the main power amplifier IMD characteristics, the Feedback loop was added to basic Feedforward Power Amplifier structure. Therefore, the output power of error amplifier can be reduced, and it is easy to control the linearization circuit to cancel total IMD. The designed power amplifier represented the 40㏈m(l0W) output power and -55㏈C 3rd IMD at Center frequency 2.14㎓ (@5㎒).

  • PDF

An Algorithm to Analyze Rail Potential Rise in DC Traction Power Supply System (레일전위상승 분석을 위한 컴퓨터 알고리즘)

  • Chung, Sang-Gi;Kim, Hyung-Chul;Jung, Ho-Sung;Kwon, Sam-Young
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.687-693
    • /
    • 2009
  • An algorithm and a computer software are developed for the analysis of rail potential rise. The algorithm is intended to be integrated with the traction power system simulation program. In the algorithm, rail potentials are obtained by two step process. First the injection currents to the negative rail are obtained from load-flow study. In the next step, a network consisting of negative rail and the injection currents are constructed. Leakage resistance to ground are added to the network. And the network is analyzed for rail potentials. A software is developed to verify the validity of the algorithm. The result of the software is compared with the Simulink/SymPower circuit analysis result. The differences between the two results are with the acceptable range. The advantage of this algorithm is that it can be integrated with the existing traction power supply simulation program easily, which usually ignores negative rail's leakage resistance.