• Title/Summary/Keyword: Negative ionization

Search Result 127, Processing Time 0.023 seconds

Local Electric Field Analysis for Evaluation of Charge Transfer System Using Sequential Sub-window Techniq (유한요소법을 이용한 쌍극자 공간전하 방전분산형 피뢰침 정전유도구체의 국부전계 해석)

  • Chung, Young-Ki;Kwak, Hee-Ro;Lee, Joon-Ho;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1650-1652
    • /
    • 2003
  • In this study, in order to increase electric field intensify near a lightning rod a floating conductor is adopted. If a floating conductor is located near the lightning rod, the positive and negative charges are equally induced on the lightning rod and the floating conductor, and the local electric field intensity near them increases. This increase of electric field intensity can ignite easily the ionization process of the surrounding air and the corona phenomenon begins there. It occurs before the usual lightning process begins on the top of the conventional rod. The charges of the ground or some buildings are omitted during the corona process through the floating conductor. Therefore, the probability of the main lightning on the conventional rod can be reduced.

  • PDF

A finite Element Analysis on the discharge characteristics of $SF_6$ gas ($SF_6$ 가스 방전 특성의 유한요소해석)

  • 최승길;심재학;강형부
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.3
    • /
    • pp.265-272
    • /
    • 2000
  • In this paper the corona discharge in SF$_{6}$ gas used as insulating material in lots o high voltage equipment, is simulated by finite element method with Flux-Corrected Transport(FCT) method. By application of proposed method the negative corona discharge characteristics in needle to plane electrode is analyzed with time step. For the accuracy of analysis the secondary electron emission by photon and ion are also considered as well as the accuracy of analysis the secondary electron emission by photon and ion are also considered as well as townsend first ionization and electron attachment. The calculated results show that the electric field intensity between anode and ion group is decreased as times go-by according to field distortion by those space charge. Accordingly the electron density is decreased strongly by the attatchment effect of SF6 gas so that the corona discharge becomes extinguished abruptly.y.

  • PDF

Simple and Robust Measurement of Blood Plasma Lysophospholipids Using Liquid Chromatography Mass Spectrometry

  • Ji, Dong Yoon;Lee, Chang-Wan;Park, Se Hee;Lee, Eun Jig;Lee, Do Yup
    • Mass Spectrometry Letters
    • /
    • v.8 no.4
    • /
    • pp.109-113
    • /
    • 2017
  • Single analytical procedure including extraction, liquid chromatography, and mass spectrometric analysis was evaluated for the simultaneous measurement of lysophospholipids (LPLs). LPLs, particularly, lysophosphatidic acids (LPA) and sphingosine 1-phosphate (S1P) are lipid messengers ubiquitously found in various biological matrix. The molecular species mediate important physiological roles in association with many diseases (e.g. cancer, inflammation, and neurodegenerative disease), which emphasize the significance of the simple and reliable analytical method for biomarker discovery and molecular mechanistic understanding. Thus, we developed analytical method mainly focusing on, but not limited by those lipid species S1P and LPA using reverse phase liquid chromatography-tandem mass spectrometry (RPLC-ESI-MS-MS). Extraction method was modified based on Folch method with optimally minimal level of ionization additive (ammonium formate 10 mM and formic acid). Reverse-phase liquid-chromatography was applied for chromatographical separation in combination with negative ionization mode electrospray-coupled Orbitrap mass spectrometry. The method validation was performed on human blood plasma in a non-targeted lipid profiling manner with full-scan MS mode and data-dependent MS/MS. The proposed method presented good inter-assay precision for primary targets, S1P and LPA. Subsequent analysis of other types of LPLs identified a broad range of lysophosphatidylcholines (LPCs) and lysophosphatidyl-ethanolamines (LPEs).

Mass spectrometric studies of competitive binding of C60 and C70 to mesosubstituted porphyrins

  • Jung, Sung-Han;Shin, Seung-Koo
    • Mass Spectrometry Letters
    • /
    • v.2 no.2
    • /
    • pp.49-52
    • /
    • 2011
  • Competitive binding of $C_{60}$ and $C_{70}$ to meso-substituted porphyrins was studied by mass spectrometry (MS). Electrospray ionization MS was employed to acquire the mass spectra of 1 : 1 porphyrin-fullerene complexes formed in a mixture of mesosubstituted porphyrin and fullerite to determine the ratio of complexes between $C_{60}$ and $C_{70}$. Matrix-free laser desorption ionization MS was used to obtain the mass spectra of fullerite to measure the mole fraction of $C_{60}$ and $C_{70}$. The binding constant ratio ($K_{70}$/$K_{60}$) was determined from the mass spectral data. The difference in standard Gibbs free energy change, ${\Delta}({\Delta}G^o)_{70-60}$, for the competitive binding of $C_{60}$ and $C_{70}$ was calculated from $K_{70}$/$K_{60}$. Of the five porphyrins, tetraphenyl, tetra(4-pyridyl), tetra(4-carboxyphenyl), tetra(3,5-di-tert-butylphenyl), and tetra(pentafluorophenyl) porphyrins, the first three non-bulky porphyrins yield negative values of ${\Delta}({\Delta}G^o)_{70-60}$, whereas the other two bulky porphyrins result in positive values of ${\Delta}({\Delta}G^o)_{70-60}$. This result indicates that $C_{70}$ binding to porphyrin is thermodynamically favored over $C_{60}$ binding in non-bulky porphyrins, but disfavored in bulky ones. It also suggests that the binding mode of $C_{70}$is different between non-bulky and bulky porphyrins, which is in line with previous experimental findings of the "side-on" binding to non-bulky porphyrins and the $C_{60}$-like "end-on" binding to bulky porphyrins.

Simultaneous analysis of glucocorticoids in bovine muscle and liver by LC-MS/MS (LC-MS/MS를 이용한 소의 근육과 간 중에 잔류하는 glucocorticoids 동시 분석)

  • Shin, Sang-Eun;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.405-413
    • /
    • 2010
  • A new method for the simultaneous determination of six glucocorticoids (betamethasone, dexamethasone, prednisone, prednisolone, methylprednisolone, and flumethasone) in meats (bovine muscle, bovine liver) were established. Samples were effectively extracted using C18 cartridge with ethylacetate. Chromatographic separation was achieved using C18 column and negative electrospray ionization mass spectrometry was performed in the Multiple Reaction Monitoring mode for the effective quantitation and qualification of glucocorticoids. Acetonitrile and water (0.1% formic acid) were used as mobile phase and additive for effective electrospray ionization, and gave good chromatographic separation and mass spectrometric sensitivity. The limit of detection (LODs) and the limit of quantitation (LOQs) in spiked blank samples depending on types of matrix and pharmaceuticals were ranged from 0.2 to $1.0\;{\mu}g$/kg and 0.8 to $3.4\;{\mu}g$/kg, respectively. And the recoveries were between 89.5 to 119.6%. The established method showed good recoveries, accuracies, precisions and fast sample preparation and it will be applied to assay of glucocorticoids residues in meat.

Rapid separation and identification of 31 major saponins in Shizhu ginseng by ultra-high performance liquid chromatography-electron spray ionization-MS/MS

  • Sun, Ting-Ting;Liang, Xin-Lei;Zhu, He-Yun;Peng, Xu-Ling;Guo, Xing-Jie;Zhao, Long-Shan
    • Journal of Ginseng Research
    • /
    • v.40 no.3
    • /
    • pp.220-228
    • /
    • 2016
  • Background: Among the various ginseng strains, Shizhu ginseng is endemic to China, mainly distributed in Kuandian Manchu Autonomous County (Liaoning Province, China); however, not much is known about the compounds (especially saponins) in Shizhu ginseng. Methods: A rapid, sensitive, and reliable ultra-high performance liquid chromatography coupled with MS/MS (UHPLC-MS/MS) method was developed to separate and identify saponins in Shizhu ginseng. Results: The separation was carried out on a Waters ACQUITY UPLC BEH $C_{18}$ column ($100mm{\times}2.1mm$, $1.7{\mu}m$) with acetonitrile and 0.1% formic acid aqueous solution as the mobile phase under a gradient elution at $40^{\circ}C$. The detection was performed on a Micromass Quattro Micro API mass spectrometer equipped with electrospray ionization source in both positive and negative modes. Under the optimized conditions, a total of 31 saponins were identified or tentatively characterized by comparing retention time and MS data with related literatures and reference substances. Conclusion: The developed UHPLC-MS/MS method was suitable for identifying and characterizing the chemical constituents in Shizhu ginseng, which provided a helpful chemical basis for further research on Shizhu ginseng.

High Speed Separation of PFCs in Human Serum by C18-Monolithic Column Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Won-Woong;Lee, Sun-Young;Yu, Se Mi;Hong, Jongki
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3727-3734
    • /
    • 2012
  • An analytical method has been developed for the rapid determination of perfluorinated compounds (PFCs) in human serum samples. The extraction and purification of PFCs from human serum were performed by the modified method of previous report. Ten PFCs were rapidly separated within 3.3 min by C18-monolithic column liquid chromatography (LC) and detected by electrospray ionization (ESI) tandem mass spectrometry (MS/MS) in negative ion mode. The runtime of PFCs on monolithic column LC was up to 4-fold faster than that on conventional column LC. The effect of triethylamine (TEA) to the mobile phase has investigated on the overall MS detection sensitivity of PFCs in ESI ionization. Quantification was performed by LC-MS/MS in multiple-ion reaction monitoring (MRM) mode, using $^{13}C$-labeled internal standards. Method validation was performed to determine recovery, linearity, precision, and limits of quantification, followed by, the analysis of a standard reference material (SRM 1957 from NIST). The overall recoveries ranged between 81.5 and 106.3% with RSDs of 3.4 to 16.2% for the entire procedure. The calibration range extended from 0.33 to 50 $ng\;mL^{-1}$, with a correlation coefficient ($R^2$) greater than 0.995 and the limits of quantification with 0.08 to 0.46 $ng\;mL^{-1}$. This approach can be used for rapid and sensitive quantitative analysis of 10 PFCs in human serum with high performance and accuracy.

Prostate Stem Cell Antigen Single Nucleotide Polymorphisms Influence Risk of Estrogen Receptor Negative Breast Cancer in Korean Females

  • Kim, Sook-Young;Yoo, Jae-Young;Shin, Ae-Sun;Kim, Yeon-Ju;Lee, Eun-Sook;Lee, Yeon-Su
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.1
    • /
    • pp.41-48
    • /
    • 2012
  • Introduction: Breast cancer is the second leading cancer in Korean women. To assess potential genetic associations between the prostate stem cell antigen (PSCA) gene in the chromosome 8q24 locus and breast cancer risk in Korean women, 13 SNPs were selected and associations with breast cancer risk were analyzed with reference to hormone receptor (HR) and menopausal status. Methods:We analyzed DNA extracted from buffy coat from 456 patients and 461 control samples, using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) based upon region-specific PCR followed by allelespecific single base primer extension reactions. Risks associated with PSCA genotypes and haplotypes were estimated with chi-square test (${\chi}^2$-test), and polytomous logistic regression models using odds ratios (OR) and 95% confidence intervals (CIs), by HR and menopausal status. Results: In case-control analysis, odds ratios (OR) of rs2294009, rs2294008, rs2978981, rs2920298, rs2976395, and rs2976396 were statistically significant only among women with estrogen receptor (ER) negative cancers, and those of rs2294008, rs2978981, rs2294010, rs2920298, rs2976394, rs10216533, and rs2976396 were statistically significant only in pre-menopausal women, and not in postmenopausal women. Risk with the TTGGCAA haplotype was significantly elevated in ER (-) status (OR= 1.48, 95% CI= 1.03~2.12, p<0.05). Especially risk of allele T of rs2294008 is significantly low in pre-menopausal breast cancer patients and AA genotype of rs2976395 in ER (-) status represents the increase of OR value. Conclusion: This report indicated for the first time that associations exist between PSCA SNPs and breast cancer susceptibility in Korean women, particularly those who are pre-menopausal with an estrogen receptor negative tumor status.

Optimal Distance between Positive and Negative Electrode-Plates Coated with Activated Carbon in Dust Removal Chamber (활성탄전극을 이용한 분진제거에서 전극의 적정 간격에 관한 연구)

  • Kim, Kwang Soo;Park, Hyun Chul;Jun, Tae Hwan;Lee, Ju Haeng;Nam, Sang Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.821-826
    • /
    • 2013
  • The purposes of this research are to study on optimal distance between positive and negative electrodes in dust removal chamber. The experiments were performed with electrode-plate gab arranging in order of 3 cm, 2 cm, 1 cm in series while varying influent flow-rate. From the experimental results of dust removal the optimal influent linear velocity was 6 cm/sec and the total mass of attached dust on the surface of electrode-plate was increased as electrode-plate gab is closer. But in case of electrode-plate gab being very close about 1 cm or so, the attached dust on the surface of electrode-plate was shown releasing from electrode-plate due to dust electric-charge changing (reverse ionization). Evantually. optimal distance between positive and negative electrode-plates was about 2 cm and also optimal dust loading rate was about $24mg/min{\cdot}m^2$.

A study on the derivatization technique for tamoxifen metabolites in human urine by gas chromatography/mass spectrometry (기체크로마토그래피/질량분석기를 이용한 인체 내 뇨시료에서의 Tamoxifen 대사체 검출을 위한 유도체화 연구)

  • Kim, Yunje;Lee, Yoonjung
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.322-336
    • /
    • 2004
  • The improved derivatization technique of tamoxifen metabolite in human urine is described for the acylation method that they are substituted by derivatization reagent like acyl anhydride for use of gas chromatography/mass spectrometry. The hydroxyl group of tamoxifen metabolite was derivatized by trifluoroacetic anhydride (TFAA), pentafluoroacetic anhydride (PFPA) and heptaflorobutylic anhydride (HFBA). It was investigated to the gas chromatography/mass spectrometry (GC/MS) technique use negative ion chemical ionization (NCI), positive ion chemical ionization (PCI) and electron impact (EI). In acylation of the metabolites of tamoxifen, the effective reaction temperature and time were shown to be at $50^{\circ}C$ for 30 min. The 4-hydroxytamoxifen, which is known to major metabolite of tamoxifen, was not detected in human urine, whileas the hydroxymethoxytamoxifen was detected. We thought that this result was from the single dose of tamoxifen.