• Title/Summary/Keyword: Negative Air Ions

Search Result 28, Processing Time 0.026 seconds

Studies on Effects of Interior Plantscaping as Related to the Air Ions (공기이온으로 본 실내녹화 효과에 관한 연구)

  • Kim, Tae-Soon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.3
    • /
    • pp.1-8
    • /
    • 2003
  • This study was carried out in order to investigate of effects of environmental conditions which influence negative ions development. Negative ions are nature' most powerful air-cleaning agents, are created by nature, and found at their most optimal levels where the air is most pure and healthy. Negative ions are regarded as one of the important factors which indicate the quality of the air. Therefore, the focus of this study was to clear relationship among negative ions development induced by plant cultivar and environmental conditions such as air temperature, light intensity and relative humidity. As the results of this study, it was found that negative ions development was promoted during the period with plants compared to the period without plants. In Particular, negative ions development was high under air temperature $20^{\circ}C$, relative humidity 90% and dark condition. Temperature and humidity factors on this experiment was strongly affected on negative ions development, but light intensity had almost slight effect. It was shown that these results can contribute to the application of environmental control techniques to negative ions. Among plant cultivar of Spathiphyllum spp. Mentha spicata, and Cupressu arizonica, Mentha spicata was higher negative ions than the other plants, and also the leaves were higher than the stems and roots. The effect of plants on the perception of the inte끼r air quality may, therefore, be one explanation of this results about negative ions. on the other hand, it seems that a green indoor environment might be an increase in general well-being due to the plants.

Formation of Internal Wind Paths of Open Space and Its Effect on Meteorological Factors and the Generation of Negative Air Ions (녹지 내부 바람통로가 기상요소와 음이온 발생량 변화에 미치는 영향)

  • Oh, Deuk-Kyun;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.29 no.4
    • /
    • pp.403-413
    • /
    • 2020
  • The purpose of this study is to understand the formation of internal wind paths of open space and its effect on meteorological factors and the generation of negative air ions. Various types of internal wind paths of open space were formed. Subsequently, changes in meteorological factors in each type were measured and the generated negative air ions were analyzed. The four key findings of the study are summarized as follows. First, the average wind speed formed inside the open space was analyzed such that the difference in wind speed was dependent on the difference in the composition of the wind path. Second, the negative air ion generation was observed to have the same trend as the average wind speed difference. Third, changes to the meteorological factors were more evident depending on the difference in wind path formation patterns. Solar radiation was expected to be highly affected by the physical structure (direction) of the target site. The relative humidity was found to show large difference depending on the different wind path type; however, this difference was significantly reduced when converting to absolute humidity. Fourth, it was found that the wind path formation type of open space affects meteorological factors through path analysis, and the changed meteorological factors affect the amount of generated negative air ions. Two conclusions can be obtained based on these results. First, the changes in internal wind speed formation of open space directly reduced the amount of generated negative air ions. Second, the changes in wind speed affect meteorological factors as well as the amount of generated negative air ions.

Evaluation on the Expected Purification Efficiency of Air Ion and Analysis on the Generated Amount of Negative Air Ions by Plants for the Purification of Particulate Matter in Air (지표대기 미세먼지 정화를 위한 식물체 음이온 발생량 분석 및 음이온의 미세먼지 기대정화지수 평가)

  • Oh, Deuk-Kyun;Ju, Jin-Hee
    • Journal of Environmental Science International
    • /
    • v.29 no.6
    • /
    • pp.623-631
    • /
    • 2020
  • This study analyzes the effect of negative air ions on the concentration of airborne particulate matter and evaluates the expected purification efficiency of open spaces for particulate matter by investigating the amount of negative air ions generated by plants. This study establishes a negative air ion generation treatment environment, plant environment, and control environment to measure the purification efficiency of particulate matter under the conditions of each, analyzing the expected purification efficiency by designing a particulate matter purification model. Results show that the amount of generated negative air ion according to environment was negative air ion generation treatment environment > plant environment > control environment; this order also applies to the particulate matter purification efficiency. Moreover, it took 65 min for the negative ion generation treatment environment, 90 min for the plant environment, and 240 min for the control environment to reach the standard expected purification efficiency of particulate matter concentration of 960 mg/㎥ for PM10. For PM2.5, with the designated maximum concentration of 700 mg/㎥, it took 60 min for the negative ion generation treatment environment, 80 min for the plant environment, and more than 240 min for the control environment. Based on these results, the expected purification efficiency compared to the control environment was quadrupled in the negative ion generation treatment environment and tripled in the plant environment on average.

The Effects of Negative Ions on Stress Responses and Cognitive Functions (산림 건강 물질이 스트레스 반응과 인지기능에 미치는 영향: 음이온을 중심으로)

  • Kim, Si Kyeong;Shin, Won Sop;Kim, Mi Kyeong;Yeoun, Poung Sik;Park, Jong Hoon;Yoo, Ri Wha
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.4
    • /
    • pp.423-430
    • /
    • 2008
  • Negative ion is considered as one of the forest health attributes. The overall purpose of this study was to investigate the influence of air negative ions on physiological effects. Data were collected from 12 volunteers (university students) who were randomly assigned into treatment and control groups. Subjects in treatment group were exposed to air with negative (2,001,000 ion/cc). Using pretest-posttest control group design, blood cortisol, norepinephrine, epinephrine, and cognitive function were measured. Data analysis indicated that negative ions influenced on positive effects of stress responses.

Evaluation of Air Ion According to Vegetation Types in Valleys and Slopes - Focused on Tangeumdae Park in ChungJu - (계곡·사면부의 식생유형에 따른 공기이온 평가 - 충주시 탄금대 공원을 대상으로 -)

  • Yoon, Young-Han;Lee, Sang-Hoon;Kim, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.519-529
    • /
    • 2020
  • The purpose of this study was to provide basic health care data for the climate aspects of park re-cultivation by evaluating air ions according to the type of vegetation in the valley and upper slopes of the mountain park. Simple negative or positive air ions were expected to show the same tendencies, so they were analyzed in terms of correcting the air ion index. By analyzing the air ions according to the topography, it was found that valley > slope in terms of the air ion index. When analyzing air ions according to tree species, we found that evergreen conifers in the valley > the deciduous broad-leaved trees in the valley > the evergreen conifers in the slope = the deciduous broad-leaved trees in the slope. For DBH(Diameter at breast height), the valley large pole > slope large pole > slope medium hard wood, while crown density was analyzed as valley dense > slope dense> valley proper > slope proper. Layered structure analysis showed that the multi-layer structure of the valley > multi-layer structure of the slope = the single-layer structure of the valley > the single-layer structure of the slope. The correlation coefficient was determined according to vegetation type and air ion index in the order of DBH > crown density > layer structure > geomorphic structure. In this study, limits exist except for ridge line, valley, and slopes in urban mountain parks. Therefore, analysis should be made considering both topographical structure and various vegetation types in future studies of air ions.

Inactivation and Filtration of Bioaerosols Using Carbon Fiber Ionizer Assisted Activated Carbon Fiber Filter (탄소섬유 이오나이저를 적용한 활성탄소섬유 필터의 바이오에어로졸 항균 및 집진 성능평가)

  • Kim, Doo Young;Park, Jae Hong;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.6 no.4
    • /
    • pp.185-192
    • /
    • 2010
  • This paper reports that the installation of a carbon fiber ionizer in front of an activated carbon fiber(ACF) filter enhanced the antibacterial efficiency. In addition, the effect of the ionizer on the filtration of bioaerosols is reported. Negative air ions from the ionizer were used as antibacterial agent. The test bacteria(Escherichia coli) were aerosolized using an atomizer and were deposited on the ACF filter media for 10 minutes. E. coli deposited on the filter were exposed to negative air ions for 0, 1, 5 and 10 minutes. Then they were separated from the ACF filter by shaking incubation with nutrient broth for 4 hours. The separated E. coli were spread on nutrient agar plates and incubated at $37^{\circ}C$ for 1~3 days. The antibacterial efficiency of E. coli was measured using a colony counting method. The antibacterial efficiencies of E. coli exposed to negative air ions for 1, 5 and 10 minutes were 14%, 48% and 71%, respectively. The filtration efficiency was evaluated by measuring the number concentration of bioaerosols at the upstream and downstream of the filter media. The increase of filtration efficiency by air ions was 14%, that is similar to the 17% filtration efficiency by none air ions. The ozone concentration was below the detection limit (under 0.01ppm) when the carbon fiber ionizers were on.

A Comparative Analysis of Negative Air Ions according to the Planting Structure at School Forests (학교 숲 식재구조에 따른 음이온 발생량 비교 분석)

  • Kim, Jeong-Ho;Oh, Deuk-Kyun;Park, Yong-Gwan;Yoon, Yong-Han
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.5
    • /
    • pp.55-64
    • /
    • 2015
  • In this study, negative air ions, which can increase comfort and positively influence human health, was set as an evaluative factor for school forests. The characteristics, location and microclimate of school forests were examined to determine an effective school forest model for maximum negative air ion generation. It also aimed to provide basic data for the development of urban green fields. The negative air ion concentrations were different according to the green types. The order from the highest to the lowest was: single-layer structure($934ea/cm^3$) > multi-layer structure($794ea/cm^3$) > grass($553ea/cm^3$) > bare ground($529ea/cm^3$). As for the correlation with microclimate, negative air ion concentration was negatively correlated with temperature. The negative air ion concentration was significantly different according to planting type. The negative air ion concentration was higher at single-layer structure sites than at multi-layer structure sites, which appears to indicate that the temperature is higher when the vegetation structure was single-layer compared to multi-layer. Wind speed was higher at the single-layer planted site than at the multi-layer planted site. The vegetation wind shielding effect was lower at single-layer planted sites than at multi-layer planted sites. The single-layer planted site provided more favorable conditions for the generation and dispersion of negative air ions.

A Study of The Surface Dielectric Barrier Discharge Design Conditions for Generating Negative Air Ions (음이온 생성을 위한 표면 유전체장벽방전의 설계조건 연구)

  • Shin, Sang-Moon;Kim, Jung-Yoon;Kim, Jong-Soo;Choi, Jae-Ha;Choi, Won-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.114-122
    • /
    • 2014
  • This paper describes a study of the design conditions of a planar surface dielectric barrier discharge (DBD) reactors for generating negative air ions. The capacity of negative air ion generated by the surface DBD reactor is affected by the shape, area ratio and the location of the discharge and induction electrodes of it. To study the optimal design conditions of DBD reactors, the electrodes printed on the substrate of a PCB board is utilized to conduct kind of experiments: the distance of the each electrode along with the X-Y axis, the area ratio of the discharge electrode to induction electrode, and the symmetrical and asymmetrical location of two electrodes. The ion generation capacity is inverse proportional to the gap increases along with X-Y axis. And the optimum ion concentration generated by the ionizer was inspected when the electrodes area ratio was 3 and 5 times of the symmetrical and asymmetrical experimental condition respectively.

Evaluation of Air Ion According to the Distance in Large Flat Park - Focused on Olympic Park in Songpa-gu, Seoul - (대규모 평지형 공원 내 거리별 공기이온 평가 - 서울시 송파구 올림픽공원을 사례로 -)

  • Kim, Jeong Ho;Lee, Sang Hoon;Lee, Myung-Hun;Yoon, Yong Han
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.5
    • /
    • pp.491-499
    • /
    • 2020
  • Increasing impervious surfaces can cause various physical and mental illnesses as well as further problems like deterioration of the thermal environment and disconnection of the water circulation system in the downtown area. This study is intended to suggest baseline data for the future creation or remodelation of large-scaled urban parks in consideration of human health on the aspect of climate by analyzing air ions condition and correlation analysis between air ions and meteorological elements depending on distances from the center in the urban park. The study site was divided into four types by distances from the center of Olympic Park in Songpa-gu, Seoul, then classified as A and B. After selecting 80 points to record, land coverage and vegetation status were investigated, and then meteorological elements and air ions were measured. First, the green space rate by section is A section Center (90%)> Inner (70%)> Outer-inner (10%) = Outer (10%), B section Center (100%)> Inner (60%)> Outer- In order of inner (30%)> Outer (0%). Second, for weather factors, the temperature was analyzed by Outer (24.18℃) > Outer-inner (22.90℃) > Inner (22.43℃) > Center (21.719℃). For relative humidity, center (46.49%) > Inner (43.36%) > Outer-inner (42.41%) > Outer (38.53%) was analyzed. Third, In the case of cations in the air ions, Outer(435.71ea/㎤) > Outer-inner(415.16ea/㎤) > Inner (389.46ea/㎤) > Center (352.64ea/㎤). In the case of negative ions, Center (569.72ea/㎤) > Inner (499.83ea/㎤) > Outer-inner(410.58ea/㎤) > Outer (292.02ea/㎤). It was analyzed to increase toward Center, and analyzed to decrease with increasing distance from road. For the Air ion index, it was analyzed as Center (1.67) > Inner (1.31) > Outer-inner (1.08) > Outer (0.71). Negative irons was analyzed to increase when its measuring points close to the center and decrease with shortening distance to the road. Fourth, as a result of correlation analysis, positive(+) correlation is negative ions and ion index. These were measured to increase as the recording points closing to the center of the park from the road. The negative(-) correlation is temperature, solar radiation, and positive ions. These increased as getting closer to the road.

Searching for Anions in the Aerosol around Jeju Samdasu Forest Environments (제주 삼다수 숲길 주변 대기질의 음이온 탐색)

  • Sin, Bang Sik;Lee, Jae H.;Song, Kyu J.;Lee, Hyung H.
    • Journal of Naturopathy
    • /
    • v.10 no.2
    • /
    • pp.114-119
    • /
    • 2021
  • Background: Many anionic phytoncides exist in the forest. Purpose: This study aimed to measure and investigate the number of negative ions in aerosol composition in Samdasu Forest, Jeju. Methods: We counted the number of negative ions in the aerosol with an anion meter at 17 points in the Samdasu forest area. Results: The average number of negative ions measured at 17 points in the aerosol of the Samdasu forest area was 719.7 ions/cm3, the temperature was 25.2℃, the humidity was 80.9%, the altitude was 503 m, and the wind speed was 0.6 m/sec. When looking at the content of anion number in the air quality in order, the highest place was waterfall-entrance-course R-course B- pine forest- course exit> exit wetland. The highest altitude of the collection point was in the order of pine forest-course R-course exit-waterfall-course B- exit wetland-entrance. The elevation difference in elevation was statistically significant. There was no correlation between altitude and anion content. It could be seen that the air quality fluctuates from time to time. Conclusions: A large amount of anionic phytoncide was contained in the air quality in Samdasu Forest in the over results. Therefore, Samdasu Forest is a helpful area as a place to visiting. The visit to the Jeju region, which has a high content of anionic phytoncide, has provided essential information that it has beneficial conditions for health management.