• 제목/요약/키워드: Needle tip

검색결과 160건 처리시간 0.028초

Electron Holography of Advanced Nanomaterials

  • Shindo, D.;Park, H.S.;Kim, J.J.;Oikawa, T.;Tomita, T.
    • Applied Microscopy
    • /
    • 제36권spc1호
    • /
    • pp.63-69
    • /
    • 2006
  • By utilizing a field emission gun and a biprism installed on a transmission electron microscope (TEM), electron holography is extensively carried out to visualize the electric and magnetic fields of nanomaterials. In the electric field analysis, the distribution of electric potential in a sharp tip made of W coated with $ZrO_2$ is visualized by applying the voltage to the tip. Denser contour lines due to the electric potential are observed with an increase in the bias voltage. In the magnetic field analysis by producing the strong magnetic field with a sharp magnetic needle made of a permanent magnet, the in situ experiment is carried out to investigate the magnetization of hard magnetic materials. The results of these experiments clearly demonstrate that electron holography is a promising advanced transmission electron microscopy technique to characterize the electric and magnetic properties of nanomaterials.

수직형 MEMS 프로브 팁의 신뢰성 설계 및 전기적 특성평가 (Reliable design and electrical characteristics of vertical MEMS probe tip)

  • 이승훈;추성일;김진혁;한동철;문성욱
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제7권1호
    • /
    • pp.23-29
    • /
    • 2007
  • Probe card is a test component which is to classify the known good die with electrical contact before the packaging in the ATE (automatic testing equipment). Conventional probe tip was mostly needle type, it has been difficult to meet with conventional type, because of decreasing chip size, pad to pad pitch and pads size increasingly. For that reason, probe cards using MEMS (micro electro mechanical system) technology have been developed for various semiconductor chips. In this paper, Area Array type MEMS Probe tip was designed,, fabricated, and characterized its mechanical and electrical properties. The authors found that good electrical characteristics under $1{\Omega}$ were acquired with gold (Au) and aluminium (Al) pad contact test over 0.5gf and 4gf respectively. And, contact resistance variation under $0.1{\Omega}$ were achieved with 100,000 times of repetition test. And, insertion loss (IS) for high frequency operation was ascertained over 300MHz at -3dB loss.

  • PDF

XLPE의 절연파괴특성에 미치는 휘발성 불순물의 영향 (Effects of Volatile Impurities on Dielectric Breakdown Characteristics of XLPE)

  • 조영신;심미자;김상욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.301-304
    • /
    • 1997
  • Effects of volatile impurities on deterioration characteristics of XLPE were investigated. Block type plate with needle-plane electrode and artificial void filled with $N_2$gas or humidity was subjected under high electric field. The dyed region by oxidation reaction around the artificial void filled with humidity was detected before tee initiation. Electrical tree was started from the tip of void filled with $N_2$gas earlier than humidity.

  • PDF

도전체와 절연체 계면에서의 전기트링 현상 (Electrical Treeing Phenomena at the Interface of Conductor and Insulator)

  • 조영신;심미자;김상욱
    • 한국표면공학회지
    • /
    • 제28권4호
    • /
    • pp.236-242
    • /
    • 1995
  • This paper describes a study of electrical tree growth in DGEBA/MDA/SN system subjected to ac high electric field. The dielectric breakdown process, which consists of tree initiation, tree propagation and the complete puncture of the system was investigated. Dielectric breakdown always initiated from the needle tip where the electric field reinforcement is the highest. Higher temperature and voltage accelerated the tree growth and reduced the time to breakdown.

  • PDF

XLPE/EPDM laminate의 절연파괴특성 (Interfacial Breakdown characteristics in XLPE/EPDM Laminate)

  • 남진호;서광석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.495-497
    • /
    • 1999
  • In order to determine what influences the interfacial breakdown in EPDM/XLPE laminates, We made the breakdown test ceil and this was pressure controllable breakdown test cell. We make the needle electrode (tip radius: about 10 micrometer) using electrochemical method. We studied the interfacial silicone oil was higher than that with silicone grease. As a function of heat treatment time in a vacuum, interfacial breakdown strength increased much in XLPE/EPDM laminates pasted with silicone grease but increased a little in that with silicone oil.

  • PDF

하치조신경 마취시 하악공으로의 접근을 위한 전산화단층촬영을 통한 방사선적 연구 (THE STUDY BY USING THE COMPUTERIZED TOMOGRAPHY IMAGING IN ORDER TO ACCESS TO MANDIBULAR FORAMEN WHILE INFERIOR ALVEOLAR NERVE ANESTHESIA)

  • 김지광;구홍;안진석;국민석;박홍주;오희균;조진형
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권6호
    • /
    • pp.566-574
    • /
    • 2006
  • Purpose : This study was performed to provide an anatomical information of the mandibular ramus for the successful inferior alveolar nerve block. Three dimensional images were reconstructed from the computerized tomography (CT) and the anatomical evaluation of the mandibular ramus was done. Materials and methods : Sixty-four patients who had been taken the facial CT scans from 2000, Jan to 2003, June was selected. The patients who had the anterior or posterior teeth misssing, edentulous ridge, and jaw fracture were excepted. In the occulusal plane, the lingual surface angle (LSA) between the mid-sagittal plane and the mandibular molar lingual surface from the 2nd premolar to the 2nd molar, the inner ramal surface angle (IRSA), the maximum inner ramal surface angle (MxIRSA), and the outer ramal surface angle (ORSA) to the-mid sagittal plane were measured. The inner ramal surface angle in the ligular tip level (IRSA-L) and the outer ramal surface angle in the ligular tip level (ORSA-L), the ramal length (RL), and the anterior ramal length (ARL) were also measured in the lingular tip level. Results : In the lingular tip level, the mean IRSA-L and ORSA-L were $28.6{\pm}6.3^{\circ}$ and $17.9{\pm}4.9^{\circ}$ respectively. The larger was the IRSA, the larger was the ORSA. In the lingular tip level, the mean ramal length was 35.8${\pm}$3.4 mm. The larger was the IRSA-L, the shorter was the ramal length. On the lingular tip level, the mean anterior ramal length from anterior ramus to lingular tip was 19.6${\pm}$3.3 mm. when the ramal length was longer, the anterior ramal length was also longer. On the lingular tip level, there was positive correlation vetween the IRSA and the ORSA, negative correlation between the IRSA and the ramal length, and positive correlation between the ramal length and the lingular tip level to the anterior ramus. There was no statistical meaning of data between sex and age. Conclusion : In the clinical view of the results so far achieved, if the direction of needle is closer to posterior it is able to contact bone on lingular tip when the internal surface of ramus is wided outer.

법랑질(琺瑯質)과 상아질(象牙質)의 산처리후(酸處理後)의 전자현미경(電子顯微鏡) 소견(所見)에 관(關)한 연구(硏究) (A STUDY ON ELECTRON-MICROSCOPIC FINDINGS AFTER ACID ETCHING ON ENAMEL AND DENTIN)

  • 김영해
    • Restorative Dentistry and Endodontics
    • /
    • 제9권1호
    • /
    • pp.115-119
    • /
    • 1983
  • The purpose of this study was to compare the solubility of enamel and dentin to an etchant after fluoride application. Specimens were collected from extracted anterior and bicuspid and each tooth was cut into several pieces. These specimen were allocated in 7 group; 1%, 2%, 3% NaF, 1%, 8%, 20% $SnF_2$, and control group. Five specimens in each group was exposed to pre-determined fluoride solution for 3 minutes, and washed with running water. These specimens were etched by Hipol (commercial label) etchant for 30 seconds. Following are the findings obtained through S.E.M. 1. All specimens with acid etching revealed preferential removal of prism periphery leaving prism core. 2. Specimens treated with 1%, 2% NaF solution showed that the shape of prism tip was thin and sharp like a needle. The case of 3% NaF showed rather round shape at prism end. 3.1% of $SnF_2$ case showed similar findings with the control group but 8% and 20% $SnF_2$ case revealed needle shape at the prism and was less clear than NaF case. Preferential removal of prism periphery was partialy observed and un decalcified area is fused to prism forming reidge. 4. Dentine treated by fluoride compound in low concentration showed the orifice of dentinal tubule was clearly enlarged whereas in high concentration the orifice was not widened.

  • PDF

상대정맥내 폴리에틸렌관 잔존물 치험 1례 (A Retained Polyethylene Catheter Fragment in Superior Vena Cava - A case report-)

  • 김주현
    • Journal of Chest Surgery
    • /
    • 제13권2호
    • /
    • pp.134-137
    • /
    • 1980
  • This represents a case report of the retained polyethylene catheter fragment in superior vena cava. A 39 year old male was admitted to this Korea University Hospital a short time after compression wound on abdomen with heavy cement material in emergency room, a polyethylene catheter was introduced into the right subclavian vein through a needle. But when the polyethylene catheter was attempted to withdraw the catheter was severed by the beveled tip of the needle. Later that day, chest X-ray disclosed the presence of the fragment extending from right subclavian vein to the superior vena cava. {Fig. 1 and Fig. 2]. Local exploration by way of an infraclavicular incision was unsuccessful in locating the catheter fragment. Another attempt was then made remove the catheter by means a biotome, which is originally a device for the biopsy of the myocardium, introduced through the right great saphenous vein. This procedure, though well tolerated by the patient, was in vain. After 11 days later, during that time he was taken a laparotomy with drain, another operation for removal of retained catheter fragment was performed through median sternotomy. After exposure of the right subclavian vein, innominate vein, and superior vena cava, an incision 1 cm in |length was made directly over the palpated catheter. The catheter immediately was picked upward and removed. The length of the catheter was approximately 8 cm. [Fig 3 ] There was no evidence of thromboembolism from the catheter or other complications. The patient made an uneventful recovery, and was discharged asymptomatic on the 9th postoperative day.

  • PDF

고분자 절연재료에서 전기트리 열화 및 절연파괴 현상 (Electrical Treeing Deterioration and Dielectric Breakdown Phenomena in Polymeric Insulator)

  • 조영신;김상욱
    • 한국재료학회지
    • /
    • 제9권4호
    • /
    • pp.398-403
    • /
    • 1999
  • 폴리에틸렌과 에폭시 수지계 고분자 정연재료에서 발생하는 전기트리 열화 및 절연파괴 현상에 대해 연구하였다. 침-평판 전극구조를 갖는 블럭상 시편에 전기적 응력을 가하고 침 선단에서 발생하는 전기트리를 관찰하였다. 저밀도 폴리에틸렌에서 발생하는 전기트리 형상은 밀도가 매우 높은 부시상이었으며, 가교 풀려에틸렌에서는 가지형 전기트리가 관찰되었다. 에폭시 수지 에서는 첨가제 SN의 함량과 온도가 증가함에 따라 절연파괴 강도는 감소하였으며 전기트리는 더욱 복잡해졌다. 가교밀도가 높아 딱딱한 DGEBA/MDA 에폭시 수지계에서는 전도성 트리 경로 주위에 일련의 부채꼴 크랙이 관찰되었다.

  • PDF

공압시험을 이용한 추력가변 노즐의 정상상태 성능 연구 (A Study on Steady State Performance of Variable Thrust Nozzle by Cold-Flow Test)

  • 김중근;이지형;오종윤;장홍빈
    • 한국추진공학회지
    • /
    • 제12권2호
    • /
    • pp.8-14
    • /
    • 2008
  • 고체 추진기관은 높은 비추력, 운용 안전성, 설계/제작하기가 쉽다는 장점이 있으나 추력 크기를 조절할 수 없다. 본 논문에서는 고체 추진기관의 추력을 조절할 수 있는 핀틀 노즐성능에 대한 연구로 Needle형 핀틀을 사용하여 수행한 공압 시험결과와 수치해석 결과를 수록하였다. 연구의 결과, 핀틀 노즐의 추력성능과 추력변화 범위는 핀틀 팁의 형상과 노즐의 Contour형상에 크게 의존하기 때문에 핀틀 팁의 형상과 노즐의 Contour형상은 중요한 설계 변수임을 알 수 있었고 특히, 시험에 적용된 Needle형 핀틀 노즐의 성능은 기존 노즐 대비 약 13%의 추력상승이 예측됨을 알 수 있었다.