• 제목/요약/키워드: Needle tip

검색결과 160건 처리시간 0.025초

전기 방사 기반의 코발트 나노 섬유의 제작 (Fabrication of Electrospun Cobalt Nanofiber)

  • 허준성;임근배
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.35-40
    • /
    • 2015
  • Electrospinning method has easy preparation of nanofibers with a simple and versatile technique. Electrospun nanofiber is widely used by the simple approach and have great potentials in the numerous applicaitons of medicine, photonics, catalysts, sensors, etc. including advantage of their specific characteristics such as large surface to volume ratio. This paper focused on the fabrication of cobalt electrospun nanofibrer for applications such as electronic, optical and mechanical devices by metal based material. We fabricated cobalt nanofibers on aluminum foil by an electrospinning method. The electrospinning process was performed at a high voltage, 8 kV. The distance between the needle tip and the solution surface in the bath was 5 cm. The PVB - cobalt based nitrate solution was filled in a 10 mL syringe connected to a 22 gauge needle. We confirmed electrospun cobalt nanofiber after annealing process by SIMS (Secondary Ion Mass Spectrometry) analysis. The concept design, fabrication and results of mapping measurements are reported.

전산화 단층촬영 투시하 성상 신경절의 경피적 고주파 열 응고술 -증례 보고- (Computerized Tomography-guided Percutaneous Radiofrequency Thermocoagulation of Stellate Ganglion -A case report-)

  • 정준석;최락민
    • The Korean Journal of Pain
    • /
    • 제12권1호
    • /
    • pp.128-131
    • /
    • 1999
  • Stellate ganglion block is a well established method for the management of certain pain syndromes (e.g., chronic regional pain syndrome, facial pain) in the cervicothoracic region and upper extremity. The stellate ganglion resides between the C7 transverse process and the head of the first rib. Anesthetic injections for the stellate ganglion block are typically made at the level of the transverse process of either the C6 or C7 vertebrae to avoid the pleura, vessels, and nerve roots. Method of positioning the needle tip directly at the ganglion has been described, but are problematic because of the risk of injury to or injection into adjacent structures. It is necessary to know the exact anatomic position of the stellate ganglion when permanent blockade is required by means of radiofrequency thermocoagulation. Whereas fluroscopy shows only bony feature, computerized tomography also images nerves, vessels, and lung, allowing accruate needle placement. We report a case of the percutaneous radiofrequency thermocoagulation of the stellate ganglion after computerized tomography-guided localization.

  • PDF

경화제 함량과 후기경화조건에 따른 DGEBA/MDA/SN계의 절연열화 특성 (Effects of Curing Agent Content and Post-curing Conditions on Dielectric Deterioration Characteristics of DGEBA/MDA/SN System)

  • 조영신;박수길;임기조;심미자;김상욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.313-316
    • /
    • 1997
  • The effects of aromatic curing agent of MDA contents and post curing conditions on dielectric deterioration characteristics of DGEBA/MDA/SN system were investigated. The dielectric properties were measured by using needle-plane electrode geometry under the commercial AC high electric field application. As the curing agent content increased, the dielectric breakdown strength increased and then decreased slightly. All the trees initiated from the tip of needle electrode and the shape of the tree in this system was a dendrite type.

  • PDF

낙법(烙法)을 이용한 흑색점 제거 증례 (Case Study on Removing Lentigo Using a Cauterization)

  • 이마음;서형식
    • 한방안이비인후피부과학회지
    • /
    • 제32권4호
    • /
    • pp.162-166
    • /
    • 2019
  • Objectives : This report is intended to suggest that lentigo can be removed using the cauterization. Methods : Handle of the needle, which is distal part to the tip and shaft, was heated with an alcohol lamp to cauterize the lentigo one by one to form a crust, and wet dressing was applied to the treatment sites by using Hwangryunhaedok-tang pharmacopuncture solution. Results : Ten days after the cauterization, the lentigo was cleared from the normal skin without adverse reactions. Conclusions : The cauterization is a useful technique for removing lentigo, but the conventional method is somewhat inconvenient, so a radiofrequency technique or a laser-based cauterization may be more useful Instead of the traditional cauterization.

An Alternative Approach to Needle Placement in Cervicothoracic Epidural Injections

  • Park, Seung-Yong;Leem, Jung-Gil;Jung, Sung-Hwan;Kim, Young-Ki;Koh, Won-Uk
    • The Korean Journal of Pain
    • /
    • 제25권3호
    • /
    • pp.183-187
    • /
    • 2012
  • The use of fluoroscopy guidance together with the loss of resistance technique during epidural injections has been advocated lately; moreover, epidural injections in the absence of fluoroscopic guidance have a high rate of inaccurate needle-tip placement during the injections. However, the approach to the lower cervical and upper thoracic epidural space may be challenging due to its obscure lateral fluoroscopic views from overlying normal tissue structures. In this case, we report an alternative oblique C-arm fluoroscopy guided view approach to supplement the standard anterior-posterior and lateral fluoroscopic views to facilitate successful needle placement and precise anatomical localization of the epidural space.

임펄스전압에 의한 수증방전특성의 분석 (Analysis of Underwater Discharge Characteristics Caused by Impulse Voltages)

  • 최종혁;안상덕;이복희
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.128-133
    • /
    • 2008
  • 이 논문은 반구형 수조에 설치되어 있는 침전극과 구형전극에 표준뇌임펄스전압을 인가하였을 때 나타나는 수중 방전현상과 절연파괴특성을 나타낸다. 이 논문의 목적은 뇌서지에 대한 과도접지임피던스와 관련된 기본적인 특성을 파악하는데 있다. 인가전압의 극성과 물의 저항률에 따른 방전광을 촬영하였고 절연파괴전압의 의존성을 측정하였다. 침전극과 구형전극의 끝단에서 스트리머코로나가 발생하였고 접지된 수조를 향하여 단계적으로 진전하였다. 저항률에 따른 절연파괴전압은 V자 형태를 나타내며, 구형전극의 절연파괴전압-시간곡선이침전극보다 높게 나타났다.

Needle형 Pintle의 위치에 따른 초음속 노즐 내부 유동장 연구 (A study on internal flow field of supersonic nozzle by needle type pintle position)

  • 이지형;김중근;장홍빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.269-272
    • /
    • 2008
  • 고체 추진기관의 추력을 조절하기 위하여 사용되는 핀틀은 초음속 유동장 내부에 위치하기 때문에 핀틀 팁의 형상과 노즐의 Contour형상에 따라 초음속 노즐 내부는 복잡한 유동장 패턴을 가지게 된다. 본 연구는 핀틀 노즐성능에 대한 연구로 Needle형 핀틀을 사용하여 수행한 공압 시험과 수치해석을 이용하여 핀틀의 위치에 따른 초음속 노즐 내부 유동장 변화가 핀틀 노즐의 추력성능에 미치는 영향에 대하여 분석하였다. 연구의 결과, 노즐 내부에 3가지 충격파가 존재하고 경사충격파의 위치가 핀틀의 위치에 따라 진동함을 알 수 있었다.

  • PDF

Influence of size and insertion depth of irrigation needle on debris extrusion and sealer penetration

  • Uzunoglu-Ozyurek, Emel;Karaaslan, Hakan;Turker, Sevinc Aktemur;Ozcelik, Bahar
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.2.1-2.10
    • /
    • 2018
  • Objectives: To determine the effect of size and insertion depth of irrigation needle on the amount of apical extruded debris and the amount of penetration depth of sealer using a confocal laser scanning microscope (CLSM). Materials and Methods: Twenty maxillary premolars were assigned to 2 groups (n = 10), according to the size of needle tip, 28 G or 30 G. Buccal roots of samples were irrigated with respective needle type inserted 1 mm short of the working length (WL), while palatal roots were irrigated with respective needle type inserted 3 mm short of the WL. Prepared teeth were removed from the pre-weighed Eppendorf tubes. Canals were filled with F3 gutta-percha cone and rhodamine B dye-labeled AH 26 sealer. Teeth were transversally sectioned at 1 and 3 mm levels from the apex and observed under a CLSM. Eppendorf tubes were incubated to evaporate the irrigant and were weighed again. The difference between pre- and post-weights was calculated, and statistical evaluation was performed. Results: Inserting needles closer to the apex and using needles with wider diameters were associated with significantly more debris extrusion (p < 0.05). The position of needles and level of sections had statistically significant effects on sealer penetration depth (p < 0.05 for both). Conclusions: Following preparation, inserting narrower needles compatible with the final apical diameter of the prepared root canal at 3 mm short of WL during final irrigation might prevent debris extrusion and improve sealer penetration in the apical third.

Impedance audiometry의 임상적 연구 - III. impedance audiometry에 의한 구씨관 기능검사 - (Clinical Study with Impedance Audiometry -Euatachian tube function and impedance audiometry-)

  • 민양기;노관택
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1976년도 제10차 학술대회연제 순서 및 초록
    • /
    • pp.85.2-85
    • /
    • 1976
  • Harford는 구씨관기능의 측정에 impedance audiometry의 진단학적 가치를 설명한 바 있다. 고막에 천공이 없는 경우 중이강내의 과도한 음압은 tympanogram에 의해 간접적으로 구씨관기능부전을 나타내는 것은 주지의 사실이다. 구씨관기능이 정상인 경우 valsalva maneuver에 의해 고막은 외측으로 밀려나갈 것이며 이것은 balance meter needle의 운동을 야기시킬 것이다. 이에 저자들은 고막, 중이, 구씨관기능이 모두 정상소견을 보이는 사람을 대상으로 valsalva maneuver에 의해 야기될 수 있는 balance meter needle의 운동거리를 측정함으로써 정상인에서의 구씨관에 의한 중이강의 공기체적의 변동양을 조사하였다. 즉, electroacoustic bridge (Madsen ZO 70) with silicone rubber probe tip을 사용하여 고막, 중이, 구씨관기능이 모두 정상인 사람에서 valsalva maneuver에 의한 balance meter needle의 운동범위는 1.0~4.0(평균치 $1.6{\pm}0.06$)이었으며, 그 치가 1.0미만인 경우에는 어떤 정도의 구씨관기능의 저하 내지 부전을 진단할 수 있는 것으로 생각되어 impedance audiometry에 의한 구씨관기능검사의 의의를 고찰하며 보고하는 바이다

  • PDF

핀틀 노즐의 비정상 특성연구 (A study of unsteady characteristics on the pintle nozzle)

  • 이지형;장홍빈;고현
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.662-665
    • /
    • 2011
  • 고체 추진기관의 추력 조절의 한 방법인 핀틀 노즐 기술은 초음속 유동장 내부에 핀틀을 위치시키고 핀틀의 위치를 조절하여 노즐 목 면적을 조절함으로써 추력의 크기를 조절한다. 본 연구는 Needle형 핀틀이 초음속 유동장 내부에서 구동될 때 발생하는 핀틀 팁에서의 압력변화와 핀틀노즐의 비정상 유동특성에 대해 분석하였다. 연구 결과 초음속 유동장 내부에서 핀틀이 움직일 때 핀틀팁에서의 압력변화가 발생하고, 이러한 압력변화에 따라 추력변화가 야기됨을 비정상상태 해석으로 확인하였다.

  • PDF