• 제목/요약/키워드: Needle tip

검색결과 160건 처리시간 0.031초

이침(耳鍼)의 불량(不良) 형태(形態) 및 불량률(不良率)에 관한 보고 (Report for Substandard type and rate of Ear Acupuncture Needle)

  • 이상훈;이새봄;최광호;최선미;류연희
    • 한국한의학연구원논문집
    • /
    • 제16권3호
    • /
    • pp.115-121
    • /
    • 2010
  • Objectives : Quality control of the needle tips and prevention of pollutions are important factor for safe and effective acupuncture treatment. Ear acupuncture needle is made by 3 companies in Korea, and used to treat for obesity or smoking in clinic frequently, but the Korean industrial Standard is proposed most recently. In spite of the importance, there has been little study about that. Moreover, there was no study about ear acupuncture needle. Methods : We investigated the current condition of needle shape and pollution about the tips and body of the ear acupuncture needle under the stereoscopic microscope. Samples are selected 100 pieces from 300 pieces randomly in each company. Results : The substandard needles are classified into four groups and counted 1. Normal condition (55.3%), 2. Scratch on the surface (14.0%), 3. Malformation of tips (19.3%), 4. Pollution of body (4.3%), 5. Multiple Substandard (7.0%). In the case of including type 2 as a standard needle, normal rate of A company was 81% when B was 76%, and C was 51%. Conclusion : The substandard ear acupuncture needles can induce local side effects such as needling pain or itching. Furthermore, it can disturb the proper effect of acupuncture treatment. We hope that this study can help to improvequality of ear acupuncture and reduce substandard rate for safe and effective ear acupuncture treatment.

노즐특성에 따른 MIST-COOLING 열전달에 관한 실험적 연구 (The Effect of Nozzle Characteristics on the Mist-Cooling Heat Transfer)

  • 이진원;강영규;백병준;박복춘
    • 열처리공학회지
    • /
    • 제5권3호
    • /
    • pp.171-178
    • /
    • 1992
  • The effect of nozzle characterristics on the mist-cooling heat transfer was investigated under the various flow conditions. Two different types of twin fluid nozzle were used, one is a $90^{\circ}$ angle tip nozzle with needle and the other is a $90^{\circ}$ angle tip non-needle nozzle. The cooling rate from the heated surface was measured and obtained the boiling curve as a function of surface temperature. An immersion sampling was employed for the measurement of droplet size of the spray. As a result of this experiment, the liquid sheet type nozzle shows better atomization when the mass ratio Mr>2.0, and collects more liquid droplets on the heated surface that results in better cooling effect. It was found that the maximum heat flux and heat transfer coefficient increased with increase in the volumetric flow rate, whereas the maximum heat flux decreased with increase in spray distance. The cooling effect depends upon the amount of collected droplet and droplet size, but it strongly depends upon the amount of collected droplet.

  • PDF

Antimicrobial Effect of Low Temperature Atmospheric Plasma against Oral Pathogens

  • Kim, Young Min;Choi, Byul Bo Ra;Park, Sang Rye;Kim, Ji Young;Kim, Gyoo Cheon
    • International Journal of Oral Biology
    • /
    • 제40권4호
    • /
    • pp.167-173
    • /
    • 2015
  • The purpose of this study was to investigate the antibacterial effect of the low temperature atmospheric plasma device with needle tip designed for easy approach to the oral cavity and root canal against Streptococcus mutans, Enterococcus faecalis and Candida albicans. The antibacterial activities evaluated by measuring clear zone of agar plate smeared with each bacteria after plasma treatment. To quantify antibacterial effects, dilution plate method was used. In addition, scanning electron microscope (SEM) was used for observation of changes in bacterial morphology. As treatment time of plasma increased, the clear zone was enlarged. The death rate was more than 99%. The SEM results showed that the globular shape of bacteria was distorted. These results suggest that needle tip plasma could be an innovative device for prevention of dental caries, and treatment of apical infection and soft tissue diseases.

에어제트직기 주 노즐내 천음속 유동의 수치 해석적 연구 (A Numerical Analysis of Transonic Flows in an Axisymmetric Main Nozzle of Air-Jet Loom)

  • 오태훈;김상덕;송동주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1998년도 춘계 학술대회논문집
    • /
    • pp.168-173
    • /
    • 1998
  • A numerical analysis of axisymetric backward facing step main nozzle flow in air jet loom has been accomplished. To obtain basic design data for an optimum main nozzle for an air-jet loom and to predict the transonic/supersonic flow, a characteristic based upwind flux difference splitting compressible Navier-Stokes method has been used. The wall static pressure of the main nozzle and the flow velocity changes in the nozzle tube were analyzed by changing air tank pressures and acceleration tube lengths. The flow inside the nozzle experiences double choking one at the needle tip and the other at the acceleration tube exit at tank pressures over $4kg_f/cm^2$. The tank pressure $P_t$ leading to the critical condition depends on the acceleration tube length; i.e, $P_t$ is higher for longer acceleration tubes. The $P_t$ value required to bring the acceleration tube exit to the critical condition is nearly constant regardless of acceleration tube length. The round needle tip shape might lead to less total pressure loss when compared with step shape.

  • PDF

외래에서 시행하는 경윤상갑상막 접근 성대주입술 중 주입 위치를 정확하게 파악하는 방법에 관한 기술적 고찰 (Technical Review of How to Determine the Exact Location of Needle Tip During Office-Based Injection Augmentation of the Vocal Folds Via Cricothyroid Approach)

  • 박성준;권택균
    • 대한후두음성언어의학회지
    • /
    • 제29권2호
    • /
    • pp.70-75
    • /
    • 2018
  • The office-based, un-sedated vocal fold injection laryngoplasty has re-emerged in the past decade as an appealing alternative to microsuspension laryngoscopic procedure which is conducted under general anesthesia. The trend toward vocal fold injection laryngoplasty in an in-office setting was possible due to technological evolution for visualization and new injection materials. However, invisibility of the injection needle has been the main shortcomings of cricothyroid approach. The purpose of this review is to provide an up-to-date review of office-based, trans-cricothyroid membrane approach injection laryngoplasty technique under local anesthesia and efforts made to increase the preciseness of amount and location of the injected materials in the management of glottic insufficiency. A review of variable efforts undertaken to maximize the result of cricothyroid approach by technically increasing accuracy of the location of needle tip was done. With the proper patient selection and utilization of the new technologies, office-based and un-sedated vocal fold injection laryngoplasty via cricothyroid approach can be redeem as a main-stay in the management of glottic insufficiency, such as vocal fold paralysis, vocal fold paresis, vocal fold atrophy and vocal fold scar.

실시간 광유도 성대주입술의 개발과 임상적 적용 (Development and Clinical Application of Real-Time Light-Guided Vocal Fold Injection)

  • 허진;차원재
    • 대한후두음성언어의학회지
    • /
    • 제33권1호
    • /
    • pp.1-6
    • /
    • 2022
  • Vocal fold injection (VFI) is widely accepted as a first line treatment in treating unilateral vocal fold paralysis and other vocal fold diseases. Although VFI is advantageous for its minimal invasiveness and efficiency, the invisibility of the needle tip remains an essential handicap in precise localization. Real-time light-guided vocal fold injection (RL-VFI) is a novel technique that was developed under the concept of performing simultaneous injection with precise placement of the needle tip under light guidance. RL-VFI has confirmed its possibility of technical implementation and the feasibility in injecting the needle from various directions through ex vivo animal studies. Further in vivo animal study has approved the safety and feasibility of the procedure when various transcutaneous approaches were applied. Currently, RL-VFI device is authorized for clinical use by the Ministry of Food and Drug Safety in South Korea and is clinically applied to patients with safe and favorable outcome. Several clinical studies are currently under process to approve the safety and the efficiency of RL-VFI. RL-VFI is expected to improve the complication rate and the functional outcome of voice. Furthermore, it will support laryngologists in overcoming the steep learning curve by its intuitive guidance.

헤드각이 변화하는 Electrosurgical Knee Wand에 적용된 형상기억합금 스프링의 전기적 피로특성 (Electro-fatigue Characteristic of Shape Memory Alloy Applied to the Electrosurgical Knee Wand of Variation of Wand Head Angle in Electrosurgical Knee Surgeries)

  • 안재욱;김철웅;이호상;왕준호;오동준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1547-1552
    • /
    • 2008
  • The tip of these catheter with straight needles is not able to reach in the vicinity of the disc bulging, which are the cause of the low back pain and because the far indirect radio-frequency treatment results in the decompression, the nucleoplasty has the limit. Many incurable diseases has not been solved due to the unexistence of the advanced technique for the MIS human body catheter device. To increase the possibility of nucleoplasty, the needle tip should be located at the closest area of the lesion. For this reason, the best way to increase the success rate of the operation is that the needle tip should access 3-dimensionally to the operating field as soon as possible. To achieve this aim, our studies are restricted as follows: 1) the SMA catheter design to control the 3-dimensional direction, 2) the security of the immediate response by the positive control of the SMA element thermal distribution using Peltier thermoelectric elements, 3) the aquisition of the control data by monitoring the relationship between the temperature of SMA element and the displacement, and 4) the design of the controller to guarantee the accurate location.

  • PDF

이침(耳鍼)의 시술 기간에 따른 체액 내 부식 안전성 연구 (Over Time Stability of Ear Acupuncture Needle in the Body Fluid)

  • 이상훈;이새봄;최광호;최선미;류연희
    • Journal of Acupuncture Research
    • /
    • 제28권5호
    • /
    • pp.97-102
    • /
    • 2011
  • Meridian Research Center, Division of Standard Research, Keora Institute of Oriental Medicine Objectives : Ear acupuncture needle is used to treat smoking, drug abusing, alcoholism frequently over time stability of ear acupuncture needle is important factor for safe acupuncture treatment. In spite of the importance, there has been few study about the quality of disposable acupuncture needle tip - using scanning electron microscope (SEM) in 2002, 2003. Moreover, there was no study about ear acupuncture needle. Methods : The three ear acupuncture needle, made in China, Japan, Korea was chosen. We used Hank's solution at the 38$^{\circ}C$ as a phantom tissue liquid. Except for the control group, five groups of needles are soused one to five days. Surface corrosion was observed using the SEM compared with control group. Results : There was no particular corrosion in all groups of ear acupuncture needles compared with the control group. Conclusions : All of the ear acupunctures used in this study are stable in body fluids at least 5 days.

유한요소해석을 이용한 수직형 프로브 팁의 설계 (Design of Vertical Type Probe Tip Using Finite Element Analysis)

  • 오영련;김윤재;남현석;박웅기;이학주;김정엽;박준협
    • 대한기계학회논문집A
    • /
    • 제36권8호
    • /
    • pp.851-856
    • /
    • 2012
  • 마이크로 프로브 팁의 설계는 매우 복잡하고 많은 비용이 든다. 이 논문에서는 새로운 타입의 프로브 팁을 유한요소해석을 이용하여 설계하였다. 유한요소해석을 이용하여 설계를 함으로써 복잡한 설계과정을 단순화 할 수 있다. 우선, 기존 프로브 팁의 실험 결과를 이용하여 유한요소해석기법을 검증하였다. 기존 프로브 팁의 물성은 $100{\mu}m$의 압축 길이시 12.5 gf 의 접촉하중이 측정되었다. 본 연구에서는 새로운 타입의 프로브 팁을 제안하였다. 새로 설계된 프로브 팁의 재료는 NiCo 이며 프로브 팁의 물성은 $100{\mu}m$의 압축 길이시 1~2 gf 의 접촉하중을 나타내었다.

경추간판적 상하복 신경총 차단 3예 (Three Cases of Transdiscal Superior Hypogastric Plexus Block)

  • 이상훈;이근상;우남식;이예철;김철호;김주완
    • The Korean Journal of Pain
    • /
    • 제9권1호
    • /
    • pp.219-222
    • /
    • 1996
  • Superior hypogastric plexus block is extensively recognized as a unique nerve block method for the treatment of low abdominal pain originating from organs of the pelvic area. This block is difficult to perform on older patients, especially those with osteophyte, as they will experience a high degree of pain with this technique. Therefore we reported trans-discal superior hypogastric plexus by method of approach needle through disc. This method is less painful to the patient as compared to bilateral approach; and easier to place the needle tip at precise and proper location.

  • PDF