• Title/Summary/Keyword: Needle tip

Search Result 160, Processing Time 0.024 seconds

Interesting Foreign Bodies (흥미있는 이물례)

  • 박옥희;김기주;김호성;조중환
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.5.1-5
    • /
    • 1981
  • We have recently removed five interesting foreign bodies successfully. Case 1. A broken tracheostomy outer cannular tube in the right main bronchus of a 7 year old boy. Case 2. An acupuncture needle in the trachea of a fifty-one year old man. Case 3. A fish hook with thread in the second isthmus of esophagus of a 10 month old girl. Case 4. An opened safety pin (sharp point toward cephalad) in the third isthmus of esophagus of a sixteen year old boy. Case 5. A big lead bullet which went through soft tissue below right mastoid tip and lodged at the mid-point between right mastoid process and foramen magnum(skull base) of a twenty year old boy, was removed surgically uneventfully.

  • PDF

Underwater Discharge Phenomena in Inhomogeneous Electric Fields Caused by Impulse Voltages

  • Lee, Bok-Hee;Kim, Dong-Seong;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.329-336
    • /
    • 2010
  • The paper describes the electrical and optical properties of underwater discharges in highly inhomogeneous electric fields caused by 1.2/50 ${\mu}s$ impulse voltages as functions of the polarity and amplitude of the applied voltage, and various water conductivities. The electric fields are formed by a point-to-plane electrode system. The formation of air bubbles is associated with a thermal process of the water located at the tip of the needle electrode, and streamer coronas can be initiated in the air bubbles and propagated through the test gap with stepped leaders. The fastest streamer channel experiences the final jump across the test gap. The negative streamer channels not only have more branches but are also more widely spread out than the positive streamer channels. The propagation velocity of the positive streamer is much faster than that of the negative one and, in fact, both these velocities are independent of the water conductivity; in addition the time-lag to breakdown is insensitive to water conductivity. The higher the water conductivity the larger the pre-breakdown energy, therefore, the ionic currents do not contribute to the initiation and propagation of the underwater discharges in the test conditions considered.

Characteristics of lightning impulse preliminary breakdown discharge under non-uniform electric field in $SF_6/CO_2$ mixtures (불평등전장에서 $SF_6/CO_2$ 혼합기체의 뇌임펄스 전구방전특성)

  • Lee, B.H.;Oh, S.K.;Baek, Y.H.;Ahn, C.H.;Jeon, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2140-2142
    • /
    • 2005
  • This paper presents the experimental results on the preliminary breakdown characteristics under a highly non-uniform electric field in $SF_6/CO_2$ gas mixtures. The impulse preliminary breakdown developments are investigated by the measurements of corona current and light emission images. As a result, the preliminary breakdown development mechanisms for both positive and negative polarities are same. The first streamer corona is initiated at the tip of needle electrode, and the leaders develop with a stepwise propagation and bridge the test gap. The pause time of leader pulses in the positive polarity is significantly shorter than that in the negative polarity. Also, the time interval between the first streamer corona onset and breakdown in the negative polarity was much longer than that in the positive polarity The discharge channel paths in the positive polarity were zigzag. On the other hands, the leader channel in the negative polarity was thicker than that in the positive polarity.

  • PDF

ZnO Nano-Powder Synthesized through a Simple Oxidation of Metallic Zn Powder in Alumina Crucible under an Air Atmosphere (대기 분위기의 알루미나 도가니 내에서 Zn 분말의 산화에 의해 합성된 ZnO 나노분말)

  • Lee, Geun-Hyoung
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.9
    • /
    • pp.861-866
    • /
    • 2010
  • Tetrapod-shaped ZnO crystals were synthesized through a simple oxidation of metallic Zn powder in air without the presence of any catalysts or substrates. X-ray diffraction data revealed that the ZnO crystals had wurtzite structure. It is supposed that the growth of the tetrapod proceeded in a vapor-solid growth mechanism. As the amount of the source powder increased, the size of the tetrapod decreased. The tip morphology of the tetrapod changed from a needle-like shape to a spherical shape with the oxidation time. ZnO crystals with rod shape were fabricated via the oxidation of Zn and Sn mixture. Sn played an important role in the formation of ZnO crystals with different morphology by affecting the growth mode of ZnO crystals. The cathodoluminescent properties were measured for the samples. The strongest green emission was observed for the rod-shaped ZnO crystals, suggesting that the crystals had the high density of oxygen vacancies.

Development of a Micro pH-ISFET Probe for in vivo Measurements of the Ion Concentration in Blood (생체내의 혈중이온농도 예측을 위한 마이크로 pH-ISFET프로브의 개발)

  • Sohn, Byung-Ki;Lee, Jong Hyun;Lee, Kwang Man
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.1
    • /
    • pp.83-90
    • /
    • 1986
  • A micro pH-ISFET probe, which can be applied to the in vivo measurements of the hydrogen ion concentration in blood, has been developed, and a measuring system equiped with this probe also developed. The pH-ISFET has been fatricated by employing the techniques of integrated circuit fabrication. Two kinds of micro electrode formed around the sensing gate during the wafer process, and the other is a capillary type of Ag/AfCl/sat. KCI reduced in size. This capillary electrode has shown its good performance characteristics so far in the application with ISFET as well as a commercial one. In order to form a micro pH-ISFET probe, this pH-ISFET and well as a commercial one. In order to form a micro pH-ISFET probe, this pH-ISFET and the capillary electrode were built together into a needle tip having 1 mm inner diameter. The chip size of a twin pH-ISFET is 0.8 mmx1.4 mm, the material of the sensing gate membrane is Si3N4, and the sensitivity of the developed probe is about 52mV/pH.

  • PDF

Caudal Epidural Injection with a Guidewire-Reinforced Epidural Catheter in Patients with Herniated Nucleosus Pulpose (추간판 탈출증 환자에서 길잡이철사가 삽입된 경막외카테터를 이용한 미추경막외조영술)

  • Ko, Justin Sangwook;Lee, Seok Jin;Hwang, Hee Youn;Sim, Woo Seok;Choi, Soo Joo;Kim, Jie Ae;Kim, Chung Su;Hahm, Tae Soo;Kim, Gaab Soo;Cho, Hyun Sung;Kim, Tae Hyeong
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.207-212
    • /
    • 2006
  • Background: The epidural injection technique is a commonly used intervention in the management of chronic spinal pain, which has the advantage of delivering various drugs, such as local anesthetics or steroids, in higher concentrations to the inflamed nerve root. A guidewire-reinforced epidural catheter was introduced through a Tuohy needle during the caudal epidural procedure, with a catheter threaded into the affected nerve roots and the spread-pattern of contrast agents observed under fluoroscopy. Methods: Sixty-seven patients with low back pain, who showed evidence of a herniated nucleus pulposus on magnetic resonance imaging, were included. All patients received fluoroscopically guided caudal epidural injections, with the guidewire-reinforced epidural catheter introduced through a Tuohy needle and threaded either to the right or left side toward the target nerve roots. After confirming the catheter tip position at the affected nerve root, 2 ml increments of contrast agents (up to 6 ml) were injected, and their corresponding AP fluoroscopic views were obtained. Three radiologists reviewed all the radiographic findings and measured the proportion of the area of contrast spread at the side of target nerve roots. Results: Greater proportion of the area of contrast spread was observed at the side of the target nerve roots (P < 0.0001). At each level of contrast injection (2-⁣, 4- ⁣ and 6 ml), more than 70% of the spread of contrast dye was observed at the side of the target nerve roots in 85%, 70%, and 55% of cases, respectively. Conclusions: The combination of a caudal epidural injection and use of a guidewire-reinforced epidural catheter significantly enhances the target specificity, as revealed by the selective spread of contrast dye at the side of target nerves.

Morphological Characteristics of Needle Leaves and Analysis of Abies species based on Chloroplast DNA Sequences (한국 전나무(Abies holophylla), 일본 전나무(A. firma, A. homolepis), 그리고 법정 보호 전나무의 잎 형태적 특성 및 엽록체 DNA 분석)

  • Ahn, Chang Ho;Choi, Yong Eui;Park, Wan Geun;Han, Jung Yeon;Kwak, Yoo Shin;Kim, Se Chang;Park, Chan Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.108 no.2
    • /
    • pp.200-207
    • /
    • 2019
  • The aim of this study was to provide the basic information necessary to identify Korean fir (Abies holophylla), momi fir (A. firma), and Nikko fir (A. homolepis), and other fir trees planted in South Korea that are protected by law. Analysis of the morphological characteristics of the needles from each sample was investigated. The shape of the needle-leaf tip from A. holophylla was acute, whereas that from A. firma and A. homolepis was emarginate and that from the protected fir trees was obtuse. The number of stomata on the needles was not significantly different between A. holophylla and A. firma, and the number of stomata on the needles from A. homolepis and the protected fir trees were highly similar. In addition, the genetic differences among the Abies species were analyzed using the sequences of five chloroplast DNA regions-matK, atpF-atpH, rpoC2-rps2, rpoC1, and psbA-trnH.The atpF-atpH and psbA-trnH regions were useful for discriminating A. firma from the other species, but there were no differences among A. holophylla, A. homolepis, and the protected fir trees. The same chloroplast sequences were found in both A. holophylla and A. homolepis, which suggests that additional genetic studies might be necessary to identify the Abies species planted in both South Korea and Japan.

Clinical Experience of Continuous Epidural Analgesia Using Baxter $Infusor^{(R)}$ (Baxter $Infusor^{(R)}$를 이용한 경막외 진통제 지속 주입)

  • Bae, Sang-Chull;Lee, Jang-Won;Kim, Ill-Ho;Song, Hoo-Bin;Park, Wook;Kim, Sung-Yell
    • The Korean Journal of Pain
    • /
    • v.4 no.2
    • /
    • pp.127-132
    • /
    • 1991
  • Recently a non-electronic, disposable and portable infusor(Baxter infusor with patient control module, Baxter health care Co., Deerfield IL 60015 USA: BI $\bar{c}$ PCM) has been developed that will deliver both a continuous drug infusion as well as allow the patient to deliver extra doses of medication on a demand basis under predetermined limitation of analgesics. Patients may also not require as high analgesic dose rate to control pain when the acceptable and tolerable level of pain relief can be maintained by this device. From April l99l, we have used a total l93 units of BI $\bar{c}$ PCM. These units consisting of two components which one made by a balloon reservoir(capacity 65 ml, flow rate 0.5 ml/hr) to store medication and to regulate the pump power(490 torr), and another two PCMs to regulate additional analgesic administration by patients demand at intervals of 1S minutes and 60 minutes. The dose administered to the patient can be varied by changing the concentration of the infusate within the balloon reservoir. These devices were utilized for the pain control of 44 patients. These patients were divided into two groups. Twenty seven cases had cancer pain and 17 cases had non-cancer pain. The Touhy needle(No. l8 G.) tip was inserted into the epidural space and was used to guide the catheter to the spinal nerve level corresponding to the most painful area. The device was connected to the opposite site of the catheter tip and was filled with 60 ml of mixture solution such as 0.5% bupivacaine 15 ml, morphine HCl 10 mg, trazodone 10 ml, Tridol 3 ml and normal saline 31 ml were administed as the initial dose. When the initial dose was less effective, the next dose could be varied by increasing the concentration of bupivacaine, by adding more morphine (5~10 mg), and by reducing the volume of normal saline. Using these modules of drug self administration, we experienced the following: 1) Improvement of patient's self titration of analgesic requirement was provided. 2) The patients anxiety with pain recurrence resulting from delays in administering pain control medication was decreased significantly. 3) The working load accompanying with the single bolus injection as the usual method was reduced remarkably. 4) There was urinary retention in 5 cases and pruritus in 4 eases which developed as side effects but respiratory depression and vomiting was not encountered in a single case.

  • PDF

GaN Nanowire Growth on Si Substrate by Utilizing MOCVD Methods (MOCVD 방법에 의한 Si 기판위 GaN 나노선의 성장)

  • Woo, Shi-Gwan;Shin, Dae-Keun;O, Byung-Sung;Lee, Hyung-Gyoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.11
    • /
    • pp.848-853
    • /
    • 2010
  • We have grown GaN nanowires by the low pressure MOCVD method on Ni deposited oxidized Si surface and have established optimum conditions by observing surface microstructure and its photoluminescence. Optimum growth temperature of $880^{\circ}C$, growth time of 30 min, TMG source flow rate of 10 sccm have resulted in dense nanowires on the surface, however further increase of growth time or TMG flow rate has not increased the length of nanowire but has formed nanocrystals. On the contrary, the increase of ammonia flow has increased the length of nanowires and the coverage of nanowire over the surface. The shape of nanowire is needle-like with a Ni droplet at its tip; the length is tens of micron with more than 40 nm in diameter. Low temperature photoluminescence obtained from the sample at optimum growth condition has revealed several peaks related to exciton decay near band-edge, but does not show any characteristic originated from one dimensional quantum confinement. Strong and broad luminescence at 2.2 eV is observed from dense nanowire samples and this suggests that the broad band is related to e-h recombination at the surface state in a nanowire. The current result is implemented to the nanowire device fabrication by nanowire bridging between micro-patterned neighboring Ni catalysis islands.

Comparative Study for Analgesic and Adverse Effects of 8% and 10% Hypertonic Saline in Epidural Adhesiolysis (경막외 유착용해술시 투여되는 8%와 10% 고장성 식염수농도의 제통효과 및 부작용의 비교)

  • Oh, Wan-Soo;Hong, Ki-Hyuk;Lee, Sang-Chul
    • The Korean Journal of Pain
    • /
    • v.13 no.1
    • /
    • pp.74-78
    • /
    • 2000
  • Background: Epidural Adhesiolysis is an interventional pain management technique for patients with low back pain. In addition to local anesthetics and corticosteroid, hypertonic saline (NaCl) are used for the technique. Present study was aimed to compare analgesic and adverse effects of two different concentration of hypertonic saline in Epidural Adhesiolysis. Methods: Fifty-three subjects with low back pain with radiculopathy were assigned to one of two epidural adhesiolysis treatment groups: 8% (Group I, n=26) or 10% (Group II, n=27) hypertonic saline. 17 G epidural needle was inserted at sacral hiatus and catheter was advanced untill its tip was located at lesion site under fluoroscopic guidance. Subjects in all treatment groups received epidural corticosteroid and local anesthetic. And then, hypertonic saline injection via catheter were carried out daily for 3 days. Evaluation included assessment of pain relief (Numerical Rating Scale; NRS) at post-epidural adhesiolysis 1, 2, 3 days, 1 week, and 1, 3 months. We also looked for complications of epidural adhesiolysis at different concentration of hypertonic saline. Results: Statistical analysis demonstrated that NRS was not significantly different between two groups during 3 months after epidural adhesiolysis. There were no major differences of complications between two groups and disappeard after a few months without residual sequelae. Conclusions: We conclude that epidural adhesiolysis using 8% hypertonic saline is effective for relief of low back pain with proven lumbosacral fibrosis without any residual sequelae compared with 10%.

  • PDF