• Title/Summary/Keyword: Neck sensor

Search Result 55, Processing Time 0.031 seconds

A Design and Implementation of Fitness Application Based on Kinect Sensor

  • Lee, Won Joo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.3
    • /
    • pp.43-50
    • /
    • 2021
  • In this paper, we design and implement KITNESS, a windows application that feeds back the accuracy of fitness motions based on Kinect sensors. The feature of this application is to use Kinect's camera and joint recognition sensor to give feedback to the user to exercise in the correct fitness position. At this time, the distance between the user and the Kinect is measured using Kinect's IR Emitter and IR Depth Sensor, and the joint, which is the user's joint position, and the Skeleton data of each joint are measured. Using this data, a certain distance is calculated for each joint position and posture of the user, and the accuracy of the posture is determined. And it is implemented so that users can check their posture through Kinect's RGB camera. That is, if the user's posture is correct, the skeleton information is displayed as a green line, and if it is not correct, the inaccurate part is displayed as a red line to inform intuitively. Through this application, the user receives feedback on the accuracy of the exercise position, so he can exercise himself in the correct position. This application classifies the exercise area into three areas: neck, waist, and leg, and increases the recognition rate of Kinect by excluding positions that Kinect does not recognize due to overlapping joints in the position of each exercise area. And at the end of the application, the last exercise is shown as an image for 5 seconds to inspire a sense of accomplishment and to continuously exercise.

Comparison of Upper and Lower Cervical Muscle Strengths Between Subjects With and Without Forward Head Posture

  • Eun, Ji-yeon;Kwon, Oh-yun;Hwang, Ui-jae;Jung, Sung-hoon;Ahn, Sun-hee
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.272-277
    • /
    • 2020
  • Background: Forward head posture (FHP) is common postural malalignment. FHP is described relatively extension to upper cervical and lower cervical is relatively flexion. Although several researchers mentioned the lower cervical flexion posture in FHP, most of the studies related to FHP is focused on the deep cervical flexor function. Objects: The purposes of present study is to compare the cervical strength (upper cervical extension [UCE], lower cervical extension [LCE], upper cervical flexion [UCF], lower cervical flexion [LCF]) between individuals with and without FHP. Methods: Fifty-one participants are recruited. Participants who have the craniovertebral angle (CVA) less than 48 degree were classified to the FHP group (n = 24) and the others were included in without FHP group (n = 27). The cervical strength (UCE, LCE, UCF, LCF) were measured using Smart KEMA strength sensor and the strength data was normalized by body weight. All strength measurement conducted at head and neck neutral position in sitting. Independent t-test was used to compare the cervical strength between individuals with and without FHP. Results: The mean value of CVA was greater in without FHP group than with FHP group (p < 0.000). The strength value of UCF (p < 0.002) and LCE (p < 0.001) was significant less in FHP group than without FHP group. But no significant differences were seen in the LCF and UCE strength between two groups. Conclusion: UCF and LCE weakness in FHP group should be considered to evaluate and manage the individuals with FHP.

Development of the Novel Intraoperative Neuromonitoring for Thyroid Surgery (갑상선 수술을 위한 새로운 수술 중 신경감시시스템의 개발)

  • Sung, Eui Suk;Lee, Byung Joo
    • International journal of thyroidology
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2018
  • It is very important to identify recurrent laryngeal nerve (RLN) and prevent RLN injury during thyroid surgery. The intraoperative neuromonitoring (IONM) for the prevention of RLN injury is a useful method because it can identify the location and status of RLN and predict postoperative vocal cord function easily. The IONM consists of a stimulating side that applies electrical stimulation to the nerve and a recording side that measures the surface electromyography (EMG) of the vocal cord muscle through electrode endotracheal tube. The nerve stimulator and surgical dissector are separate instruments. So, during IONM for the prevention of the RLN injury in conventional, endoscopic, or robotic thyroid surgery, repeated exchanging between surgical instruments and the nerve stimulator is inconvenient and time consuming. On the recording side, the accuracy of the electrode endotracheal tube which measures the EMG of the vocalis muscle can be affected by contact with between electrode and vocal fold and position change of patient. We would like to introduce recent several researches to overcome the current limitations of IONM.

Reliability of Muscle Evaluation with a Tactile Sensor System (촉각센서를 이용한 근육평가의 신뢰도 조사)

  • Oh, Young-Rak;Lee, Dong-Ju;Kim, Sung-Hwan;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.337-344
    • /
    • 2005
  • A tactile sensor employs a piezoelectric element to detect contact frequency shifts and thereby measure the stiffness or softness of material such as tissue, which allows the sensor to be used in many fields of research for urology, cardiology, gynecology, sports medicine and caner detection and especially for cosmetics and skin care. In this study, reliability of the tactile sensor system was investigated with its manual application to the muscles susceptible to temporomandibular disorders. Stiffness and elasticity of anterior temporalis, masseter and trapezius muscles were calibrated bilaterally from 5 healthy men with an average of 24.5$\pm$0.94 years. The tactile sensor used in this study had a computer-controlled and motor-driven sensor unit which automatically pressed down on the skin surface over the muscles being measured and retracted, thereby providing the hysteresis curve. The slope of the tangent of the hysteresis curve (${\Delta}f/{\Delta}x$) is defined as stiffness of the muscle being measured and the distance between the two parts of the curve as its elasticity. To determine inter-examiner reliability, all the measurements were performed by the two examiners A and B, respectively and the same examination were repeated with an interval of 2 days for intra-examiner reliability. The results from this study demonstrated high reliability in measuring stiffness and elasticity of anterior temporalis, masseter and upper trapezius muscles using a tactile sensor system. It is suggested that the tactile sensor system can be a highly reproducible and effective instrument for quantitative evaluation of the muscle in head and neck region.

Establishment of Data Base for Body Temperature Change in Cattle (소의 일중 체온변화 Data Base 구축에 관한 연구)

  • Jeong, Wang-Yong;Yi, One-Hyeon;Lee, Sang-Cheol;Lee, Sang-Rak
    • Journal of Animal Environmental Science
    • /
    • v.18 no.2
    • /
    • pp.95-98
    • /
    • 2012
  • A normal body temperature data base for cattle was established to utilize for automatic monitoring of abnormal body condition of cattle by using sensor network and radio frequency identification technology. Three castrated Holstein cattle (mean body weight: $318{\pm}12kg$) were employed for body temperature measurement. Animals were adapted at the stanchion barn over 2 weeks, and 4 places (skins of ear, neck, head and subcutaneous tissue of neck) of body temperatures were continuously measured through thermocouples and recorder devices for 9 days. All places of body temperatures were fluctuated throughout the day and showed a cyclic pattern, with higher temperature in day time and lower temperature in nigh time. Normal subcutaneous tissue temperature (core temperature) in a day was ranged from $36.1^{\circ}C$ to $38.2^{\circ}C$. Skin temperatures were varied largely with environmental temperature change. Ear, head and neck temperatures varied with $36.3{\sim}28.5^{\circ}C$, $36.1{\sim}28.0^{\circ}C$ and $35.0{\sim}28.2^{\circ}C$, respectively. In this study, we established a basic data base for normal body temperature in cattle. For more effective data base, it would be needed further study.

Research trends on prevention of heat stroke using clothing: Focusing on practical research in Japan (의복을 활용한 열중증 예방 대책에 관한 연구 동향 조사: 일본의 실용 지향적 연구를 중심으로)

  • Son, Su-Young
    • Human Ecology Research
    • /
    • v.56 no.5
    • /
    • pp.473-491
    • /
    • 2018
  • This study identifies Japanese study content on heat stroke prevention measures using clothes, provides basic data for quantitative wearing assessment studies, presents a developmental direction for those, and helps invigorate further research. Studies were collected concerning clothing-based heat stroke measures in order to analyze the following factors: current status of heat stroke by industry and working environment, heat stroke and body cooling method, clothing microclimate and air circulation in a hot environment, hot environments and wearable sensors, and heat stress reduction and skin exposure. The current WBGT standard does not consider the diversity of wearing clothes according to the working environment. Therefore, it is preferable to add a correction value in consideration of design, materials, and ventilation to prevent heat strokes. For the heat stroke and body cooling method, wearing water-perfused clothing is effective to reduce heat stress and maintain exercise ability. Changing the material and design of clothing or wearing air-conditioned clothing can improve ventilation and the clothing microclimate. However, further evaluation is needed on the effectiveness of air-conditioned clothing as a heat stroke prevention product. The measurement method using a wearable sensor can provide real-time data on the body response due to working in a hot environment. Therefore, it is an effective alarm for heat stroke. Skin exposure area and heat dissipation efficiency should be considered to prevent heat stroke. Reducing the covering area by exposing the head, neck, and limbs, and wearing breathable material can prevent heat stroke from increased body temperature.

A Comparison of PM10 Exposure Characteristics of Swine Farmers by Body Parts using Direct-reading Instrument (직독식 기기를 이용한 양돈작업자의 신체부위별 PM10 노출 특성 비교 연구)

  • Sin, Sojung;Kim, Hyocher;Kim, Kyung-ran;Seo, Mintae;Park, Sooin;Kim, Kyungmin;Kim, Kyungsu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.159-166
    • /
    • 2019
  • Objectives: The purpose of this study was to evaluate the personal exposure to $PM_{10}$ by body parts for the development of dust monitoring wearable device for swine farmers. Methods: Tasks were classified by using motion pictures taken by action cameras attached to swine farmers. Concentrations of $PM_{10}$ were measured by attaching direct-reading instruments at the head, neck and waist of worker. Differences of $PM_{10}$ exposure between body parts were analyzed with linear regression. Results: We identified three tasks(vaccination, moving pigs, and manure treatment). $PM_{10}$ concentration during vaccination was the highest among the tasks, and the body part showing the highest concentration of $PM_{10}$ was the waist regardless of task. In all tasks, the closer distance between the body parts, the higher were the R-squared values(vaccination 0.4221, moving pigs 0.6990, and manure treatment 0.2164). Conclusions: We presumed that $PM_{10}$ concentrations were affected by the parts of the body in which they were measured. In order to develop swine farmer's wearable device for monitoring dust concentration in air, the determination of the positions of monitoring sensor to ensure accurate measurement is essential. Considering the results of this study, wearable sensor should be positioned at the waist.

Design of ECG/PPG Gating System in MRI Environment (MRI용 심전도/혈류 게이팅 시스템 설계)

  • Jang, Bong-Ryeol;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.132-138
    • /
    • 2007
  • MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

The Proposed of Emergency Light Monitoring System by Self-Organization Radio Communication based on USN (USN기반 자율무선통신방식 비상등관리시스템 제안)

  • Choi, Jae-Myeong;Kang, Heau-Jo;Lee, Sang-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.2
    • /
    • pp.252-256
    • /
    • 2009
  • In this paper, the emergency light where is being scattered always inspection and will be able to manage from the management center. Is not interfered in data neck of a bottle actual condition and the data communication will be possible and the cluster monitor network will grow and uses establishes the emergency light monitoring system. Will not be interfered in location of emergency light and not to be will be able to establish the system. And the monitoring network there is by a destroyer and the communication relay system is born breakdown but the dead zone without condition of emergency light proposes the emergency light management system where the monitoring and management are possible.

  • PDF

Development of Sensor Node for Temperature Monitoring of Livestock Based on IEEE 802.15.4 (IEEE 802.15.4 기반의 가축 체온 모니터링 센서 노드 개발)

  • Lee, S.J.;Kim, Do Hyeun
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.7
    • /
    • pp.886-894
    • /
    • 2014
  • Recently, domestic animal disease caused tremendous damage to farmhouses and the damage stretched in nationwide with the spread of epidemic disease. To prevent animal diseases from happening again, the system development to easily measure the temperature of sick animals and identify of them is needed, thereby quickly treat them, reducing losses of farmhouses. However, a lack of related equipment and human resource hampered its effort to minimize its losses. This study tries to develop diagnosis system as part of measures to curb these domestic animal diseases. This paper present the 센서 node based on IEEE 802.15.4 which can be attached to the animal body for real-time temperature measurement. We design and implement tiny chip-type that can be attached to the body of animals. Then, we use available power only when measuring temperatures in a long term-basis. In this paper, the 센서 node was applied to horse's neck. We measure the horse's body temperature between $32.2^{\circ}C{\sim}33.7^{\circ}C$ and analyze phenomenon data for 4 months.