• 제목/요약/키워드: Neck fracture

검색결과 236건 처리시간 0.025초

The Reliability and Validity of Hip Range of Motion Measurement using a Smart phone Operative Patient (엉덩관절 수술 환자에서 스마트폰을 이용한 관절가동범위 측정의 신뢰도 및 타당도 연구)

  • Park, Sun-Wook;Kim, Myoung-Soo;Bae, Hyo-Sun;Cha, Yong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • 제10권2호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE: The aims of this study were to assess the intra-tester and inter-tester reliability and validity of hip range of motion using a smart phone in hip operative patients. METHODS: Twenty-five patients (eight total hip arthroplasty and seventeen femur neck fracture) participated in this study. The range of motions in active and passive hip flexion, abduction and external rotation were measured with a goniometer and smart phone over two times by two observers. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC2,1). The validity was measured by Pearson's correlation coefficient RESULTS: The intra-observer reliability was good in all measured items (ICC>0.78). The inter-observer reliability was high with ICC (>0.90). All correlation coefficients of smart phone and goniometer was greater than 0.85 and showed a significant positive correlation (p<0.01). CONCLUSION: The range of motion measurement with a smart phone showed acceptable reliability. Therefore, it could be convenient and have economical benefits to measure the range of motion of the hip joint using a smart phone.

Case Series: Successful Resuscitation of Severe Facial Injuries Caused by a Chainsaw

  • Choi, Han Joo
    • Journal of Trauma and Injury
    • /
    • 제32권3호
    • /
    • pp.168-171
    • /
    • 2019
  • The treatment outcome remains poor of severe facial injuries because of the high risk of compromised airway or massive bleeding. We experienced two successful treatment cases of severe facial injury by the chainsaw. A 52-year-male had his face injured by the chainsaw during his work. He was transferred to the Level I trauma center using the Doctor-Helicopter. During his flight, bleeding control was tried and the information was given to the trauma surgeons before his arrival. His consciousness was alert and the vital signs were stable. The crushing wound, mandible open fracture, deep laceration of tongue, lip, neck and arterial bleeding were noted around his mandible. Nasotracheal intubation was performed under the bronchoscope-guided. Emergency operation (open reduction & internal fixation, primary repair with neurorrhaphy) was performed. At 30 hospital days, he was discharged with facial palsy on left mandibular area. A 30-year-male had his face injured by the chainsaw. He was transferred to our Level I trauma center from the local hospital. The deep-mutiple lacerations on right upper eyelid and forehead with the bony exposure were noted. The vital signs were stable and emergency operation was performed. He was discharged at 20 hospital days. Bone loss or tissue loss were not devastating than we expected even though the injury was occurred by the chainsaw. Aggressive treatment including airway manipulation or bleeding control and maximal opportunity of therapy are absolutely needed.

Influence of Friction Between Materials on the Axial Direction Pull Force in Single Clinching (싱글 클린칭 공정에서 소재간 마찰이 축방향 분리력에 미치는 영향)

  • Lee, D.W.;Sekar, R.;Lee, C.J.;Joun, M.S.
    • Transactions of Materials Processing
    • /
    • 제30권2호
    • /
    • pp.83-90
    • /
    • 2021
  • In this paper, a parametric study on the influence of friction between materials on pull force in single clinching is conducted using an axisymmetric elasto-plastic finite element method and law of Coulomb friction. An appropriate finite element analysis model is given, which minimizes the effect of the material model and numerical factors including the number of quadrilateral finite elements and blank radius. It is emphasized that the elasto-plastic material model should be employed because the elastic deformation of the internal region is affected more by the pull force. It has been shown that the pull force increases as friction coefficient increases and that the optimized friction coefficient is around 0.4, which is qualitatively comparable with its theoretical value. When the friction coefficient reaches 0.5 in the example studied, the neck fracture is predicted.

Correction of Atlanto-axial Instability by Avulsion Fracture of the Axis in a Dog (중쇠뼈 찢김골절로 인한 고리중쇠 관절 불안정의 교정)

  • Hwang, Yong-Hyun;Kim, Minkyung;Park, Jung-Hyun;Jin, So-Young;Park, Ki-Tae;Lee, Hee-Chun;Lee, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • 제30권6호
    • /
    • pp.499-502
    • /
    • 2013
  • An eight-year-old, castrated male, Poodle dog was presented with a bite wound in the neck region. Clinical examination revealed non-ambulatory signs of tetraparesis with deep pain, and upper motor neuron changes in all limbs. Fractures of the transverse process of C1 and the dorsal spinous process of C2 were observed on the radiographs and the computed tomography (CT). Conservative therapy was performed for 1 week. However the neurological problems were not alleviated until 7 days after injury. The owners agreed to perform surgical stabilization. The surgical stabilization was performed 7 days after presentation. Ventral stabilization was performed with screws, K-wires and bone cement. The dog stood up independently after 4 weeks and was able to walk 6 weeks postoperatively. In this report we suggest that using combined stabilization techniques are effective for this type of cervical fracture in which the dorsal and ventral structures of the vertebra are severely disrupted.

Operative Treatment of Terrible Triad in Elbow of Adults (성인 주관절의 요골두와 구상돌기 골절을 동반한 탈구의 수술 적 치료 (성인 주관절에 발생한 위험3증주의 수술적 치료))

  • Kim, Byung-Heum;Park, Jong-Seok;Choi, Ho-Rim;Lee, Sang-Sun;Rah, Soo-Kyun;Lee, Hyun-Wook
    • Clinics in Shoulder and Elbow
    • /
    • 제9권1호
    • /
    • pp.50-59
    • /
    • 2006
  • Purpose: The nonoperative outcome of elbow dislocations with associated radial head and coronoid fractures are often unsatisfactory because of chronic instability and stiffness from proloned immobilization, Therefore we managed these injuries with well programed surgical appproaches. Method: Ten patients with this injury were evaluated retrospectively from May 1998 to June 2004 after a minimum of 12 months. These injuries include elbow dislocation and associated fractures of both the radial head and the coronoid process. All ten patients were treated by one clinic operatively with similar scheduled surgical methods which started on the lateral side and terminated on the medial side of the elbow. Radial head and neck fractures were classified Mason types, as two and three types respectively with six and four cases and six cases were fixated. Coronoid process were fixated with screws anteroposterior directly or anchor suture in all cases, each type was classified one, two and three. where were three type one, four type two, and three type three were according to Regan and Morrey classification. Results: The outcome was three resulting in excellent, four good, two normaland and the remaining case was one poor according to the Mayo Elbow Performance score. At a terminal follow up, the range of motion of the elbow averaged flection contracture, $6^{\circ}(0{\sim}20^{\circ})$ and further flection, $129^{\circ}(115{\sim}140^{\circ})$. Two patients had complications requiring additional care. One, displaced coronoid process which was repaired with capsule and the other patient experienced, palsy of ulnar nerve and contracted elbow joint. Conclusions: Usage of early operation as the minimum injury of medial ligaments complex and the rigid fixation of fractures to prompt motion with our scheduled management for elbow dislocations with associated radial head and coracoid fractures provided excellent results.

Stabilization using Screws, Wire, and PMMA for Traumatic Cervical Fracture in a Maltese Dog (말티즈 견에서 Screw, Wire와 PMMA를 사용한 외상성 경추 골절의 안정화)

  • Kim, KeunYung;Kim, Minkyung;Park, Ji-Hun;Shin, Jeong-In;Kim, Junsu;Jang, Yun-Seol;Lee, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • 제31권6호
    • /
    • pp.519-522
    • /
    • 2014
  • A 2-year-old, 2 kg Maltese dog was evaluated for progressive tetraparesis and neck pain. The dog had been treated with steroids for the preceding 2 weeks after unknown trauma but was deteriorating progressively and had become tetraparetic. The dog was presented with a non-ambulatory tetraparesis. Radiographic and computed tomographic examinations revealed a transverse C2 fracture with subluxation of the atlantoaxial joint and C2-C3. In addition, hydrocephalus was observed on magnetic resonance imaging. Stabilization of C1-C3 using screws, wires, and polymethyl methacrylate (PMMA) was performed. Application of ventral screws, wires, and PMMA resulted in improvement of the clinical signs after 4 weeks, and the dog could walk as before the tetraparesis 6 weeks after the operation. This stabilization method is an effective surgical treatment for management of cervical instability.

A Study on the Causes of Injury Codes by Case-Based Injury Code of External Causes Frequency Analysis (사례 중심의 손상코드 별 손상외인코드 빈도수 분석에 따른 손상코드 발생 원인에 관한 연구)

  • Eun-Mee Choi;Hye-Eun Jin;Jin-Hyoung Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • 제16권1호
    • /
    • pp.50-59
    • /
    • 2023
  • The purpose of this study was to analyze the patients hospitalized with damage by injury code based on data for two years in 2020 and 2021 of A institution located in Gangneung, Gangwon-do. Analyzed the injury codes with a large number of occurrences per year, and analyzed the injury codes of external causes accordingly. The cause of the injury code was analyzed by analyzing the frequency of the injury code of external causes. Injury code S0650 had the highest frequency of injury code of external causes W189 and X5999, which was judged to be the cause of traumatic subdural hemorrhage without open intracranial wounds when falling in an unspecified place or toilet. Injury code S72120 had the highest frequency of injury code of external causes W010 and W180, and it was judged to be the cause of obstructive femoral intertrochanteric fracture that occurs when falling in the residence. The injury code S32090 had a high frequency of X5999, and it was analyzed that it caused the obstructive fracture of the lumbar region due to an accident caused by exposure in an unspecified place, and the injury code S72.090 had a high frequency of W010 and W180. It was confirmed that the cause of the obstructive fracture of the femoral neck was mainly caused by slipping or slipping in the residence, and the injury code S0220 had a high frequency of the injury code of external causes Y049, and it was confirmed that the fibula was fractured mainly by the force or fist. As such, the cause of the injury code was analyzed by analyzing the frequency of the injury code for each injury code of external causes.

National Survey of Injury and Poisoning on a Representative Sample Population of Koreans (우리나라 대표적(代表的) 표본인구(標本人口)의 연간(年間) 손상(損傷) 및 중독발생율(中毒發生率)과 역학적(疫學的) 특성(特性))

  • Kim, Joung-Soon;Kim, Sung-Soo;Chang, Sung-Chill
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권3호
    • /
    • pp.447-463
    • /
    • 1994
  • Despite the public health importance of injury and poisoning in terms of its high mortality and incidence, epidemiologic information to be utilized are scarce in Korea. This study was carried out in 1990 on a representative sample population (about 55,000 persons) along with the 6th National Tuberculosis Prevalence Survey in order to estimate the magnitude of injury and poisoning occurrence and to identify its epidemiologic characteristics which can be aided for establishing preventive strategy. Pre-tested and structured Questionnaire was used by trained interviewer to collect data including general information of the person, various information on the injury and poisoning during the past one year such as time and place of its occurrence, its nature and external causes, type of medical institute attended, duration of treatment and outcome of the accident occured. In analysis of the data collected incidence rates per 1000 persons by sex, age group and its nature as well as external causes, and relative frequencies were calculated. The result obtained are as followings; 1. The incidence rate per 1000 was 30 for both sexes, 39 for male and 22 for female, male being 1.8 times more frequent than female. Age adjusted incidences were not much different from the crude rates. Age group specific rate curve showed bimodal shape in both sexes, small peaks in preschool children and higher peaks in older ages. The incidence rate per 1000 people by area was highest in Jeon-bug province (57/1000) and the lowest in Daegu city(11/1000). 2. The place where the injuries occured were road in 46%, within the boundary of house in 25%, and working place in 12% The injuries and poisoning had occured more frequently during the months from March to August of the year than other months. 3. The relatively frequent injuries by its nature were contusion with intact skin surface (19%), fracture of upper limb (13%), open wound of head, neck and trunk (12%) and fracture of lower limb (11%) among males; contusion with intact skin surface (28%), sprains and strains of joints and adjacent muscle (14%), fracture of upper limb (10%) and fracture of lower limb (9%) among females. Higher incidence rate among males than females were fracture of skull (4.5 times), open wound and fractures of limbs ($2{\sim}3$ times). Age specific rate of injuries and poisoning by its nature showed increasing pattern by age in fractures of upper and lower limbs and sprains & strains of joints whereas the age group of 30's showed highest incidence in open wounds of upper limb. Fractures of radius and ulna in upper limb, fractures of tibia & fibula and ankle in lower limb were most frequent among fractures of upper and lower limbs. The frequent injuries among sprains and strains of joints and adjacent muscles were that of ankle, foot and back, and among open wound were that of head and fingers. 4. Relative frequency of injuries and poisoning by external causes showed following order : other accidents (25%), accidental falls (23%), motor vehicle accident (22%) and other road vehicle accident (14%) among males and accidental falls (37%), motor vehicle accident (24%) and other accident (18%) among females. The external causes revealing higher incidences among males than females, were other road vehicle accident (4.8 times), vehicle accident not elsewhere classifiable (4.4 times), accidental poisoning (4.4 times), accidents due to natural and environmental factors (2.8 times), and sucide & self-inflicted injuries (2.8 times). Age specific incidence by external causes for frequent injuries showed that incidence of other accident steadily increased from 10's till age 50's; motor vehicle traffic accident increased from age 20's and dropped after age 60's; on the other hand accidental fall increased strikingly by age. The most frequent external causes among motor vehicle traffic accidents was motor vehicle traffic accident involving collision with pedstrain (69%), pedal cycle accident (30%) and other road vehicle accident (71%) among other road vehicle accidents; falls on same level from slipping, tripping or standing (44%) and other falls from one level to another among accidental falls; accidents caused by machinary (32%) for male and striking against or struck accidentally by objects or person for female among other accidents. 5. Seventy nine percent of the injuries and poisonings were treated in general hospital or hospital/clinic. The duration of treatment ranged from a few days to 123 weeks; the majority(52%) took under 2 weeks, 36% for $3{\sim}8$ weeks and 4% over 21 weeks. 6. The accident resulted in full recovery of normal healthy state in 62%, residual functional defects in 21% and on process of treatment in 16%.

  • PDF

Some Factors Affecting Bone Mineral Status of Postmenopausal Women (폐경 후 여성의 골격상태에 영향을 미치는 요인분석)

  • 오세인;이행신;이미숙;김초일;권인순;박상철
    • Korean Journal of Community Nutrition
    • /
    • 제7권1호
    • /
    • pp.121-129
    • /
    • 2002
  • Osteoporosis, the typical metabolic bone disease of the elderly, is characterized by a reduction in bone mineral density (BMD) and increased fracture risk. Genetic and environmental factors are known to play a key role in bone metabolism, and diet is also considered to be one of the important factors. The purpose of the present study was to investigate the relationship among the factors affecting BMD, including stature, body weight, age, time period since onset of menopause, and biochemical markers of bone turnover in postmenopausal women. Seventy-eight postmenopausal women who visited health promotion center for health examinations volunteered to participate in this study and they were divided into two groups according to the time period since onset of menopause : women with a time period since onset of menopause of less than 5 years (Group 1) and women with a time period since onset of menopause of 5 years or more (Group 2). The demographic characteristics and dietary intake were surveyed using a questionnaire. BMDs of the lumbar spine and femoral neck of subjects were measured by dual energy X-ray absorptiometry. Serum levels of 25-hydroxy-vitamin D and parathyroid hormone (PTH), known to be indicators of bone related hormone status, were anlyzed. Serum samples were measured for calcium, phosphorus, alkaline phosphatase, and osteocalcin as bone formation indicators, and urine was analysed for deoxypyridinoline, creatinine, calcium, and sodium as bone resorption indicators. The results are as follow : The mean BMDs of the lumbar spin and femoral neck were $1.02 \pm 0.02 g/cm^2 and 0.81 \pm 0.02 g/cm^2 respectively, and the BMD level of Group 2 was significantly lower than tat of Group 1 (p<0.01, p<0.05, respectively). The mean daily intake of energy was 1838 $\pm$ 55 kcal. When nutrient intake was compared with the recommended dietary allowances (RDA) of the subjects, only calcium, vitamin A and riboflavin intake showed means lower than the RDA. The nutrient intake did not show any significant differences between Group 1 and 2 Serum and urine levels of biochemical markers of bone turnover did not show any significant differences between Group 1 and 2, and all were within the normal range. However, the PTH and deoxypyridinoline levels showed a tendency to be higher, and the osteocalcin level to be lower in Group 2 than in Group 1. Although age and years after menopause (YAM) showed negative correlations with lumbar spine bone mineral density (LBMD) (r= -0.38, p<0.001, and r= -0.26, p< 0.05, respectively), no correlation was found with femoral neck bone mineral density (NBMD). While height, body weight and body mass index (BMI) showed a positive correlation with LBMD (r= 0.32, p<0.001, r= 0.38, p<0.001, r= 0.22, p= 0.05, respectively), only body weight and BMI showed a positive correlation with NBMD (r= 0.30, p<0.01, and r= 0.27, p<0.05, respectivley). There was no significant corealtion between BMDs and the nutrient intake of subjects, except in the case of carbohydrates (r= 0.22, p<0.05). Also, serum and urine levels of bone turnover markers showed no significant correlation with nutrient intake. On the other hand, serum osteocalcin had a positive correlation with vitamin C intake (r= 0.22, p= 0.05), and urine deoxypyridinolin showed a negative correlation with niacin intake (r= -0.22, p= 0.05). Urinary na was negatively correlated with protein intake(r= -0.23, p= 0.05). The results suggested that it is difficult to prevent the decrease in bone mass among postmenopausal women eating the usual Korean diet. However, the BMDs of the lumbar spine and femoral neck were positively related to body weight ad BMI in postmenopausal women. Therefore, this study confirmed that one of the most effective ways to minimize bone loss in postmenopausal women would be to maintain an adequate body weight with balanced nutrient intake and activity in the pre-and postmenopausal periods.

Changes In Mechanical Strength of Compression HIP Screws in Relation to Design Variations - A Biomechanical Analysis

  • Moon S. J.;Lee H. S.;Jun S. C.;Jung T. G.;Ahn S. Y.;Lee H.;Lee S. J.
    • Journal of Biomedical Engineering Research
    • /
    • 제26권2호
    • /
    • pp.123-127
    • /
    • 2005
  • Compression Hip Screw (CHS) is one of the most widely-used prostheses for the treatment of intertrochanteric fractures because of its strong fixation capability. Fractures at the neck and screw holes are frequently noted as some of its clinical drawbacks, which warrant more in-depth biomechanical analysis on its design variables. The purpose of this study was to evaluate changes in the strength with respect to the changes in design such as the plate thickness and the number of screw holes. Both mechanical test and FEM analysis were used to systematically investigate the sensitivities of the above-mentioned design variables. For the first part of the mechanical test, CHS (n=20) were tested until failure. The CHS specimens were classified into four groups: Group Ⅰ was the control group with the neck thickness of 6-㎜ and 5 screw holes on the side plate, Group Ⅱ 6-㎜ thick and 8 holes, Group Ⅲ 7.5-㎜ thick and 5 holes, and Group Ⅳ 7.5-㎜ thick and 8 holes. Then, the fatigue test was done for each group by imparting 50% and 75% of the failure loads for one million cycles. For the FEM analysis, FE models were made for each group. Appropriate loading and boundary conditions were applied based on the failure test results. Stresses were assessed. Mechanical test results indicated that the failure strength increased dramatically by 80% with thicker plate. However, the strength remained unchanged or decreased slightly despite the increase in number of holes. These results indicated the higher sensitivity of plate thickness to the implant strength. No fatigue failures were observed which suggested the implant could withstand at least one million cycles of fatigue load regardless of the design changes. Our FEM results also supported the above results by showing a similar trend in stress as those of mechanical test. In summary, our biomechanical results were able to show that plate thickness could be a more important variable in design for reinforcing the strength of CHS than the number of screw holes.