• Title/Summary/Keyword: Neck ROM

Search Result 110, Processing Time 0.023 seconds

The effects of Upper Thoracic Joint Mobilization Technique using Kaltenborn-Evjenth concept on Cervicothoracic ROM and Pain in patients with Chronic Neck Pain (Kaltenborn-Evjenth concept을 이용한 상부흉추 관절가동술이 만성 경부통증 환자의 경흉추 관절 가동범위의 변화와 통증에 미치는 영향)

  • Jun, Young Wook;So, Hyun Jeong;Jeong, Youn Do;Um, Sung Heum
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.479-486
    • /
    • 2015
  • This study was conducted to investigate the effects of upper thoracic joint mobilization technique using Kaltenborn-Evjenth concept on the range of cervical and thoracic motion and pain in patients with chronic neck pain. The subjects were divided into a thoracic joint mobilization group(n=7) and a conservative physical therapy group(n=7). Each of the groups received thoracic joint mobilization or conservative physical therapy three times a week lasted for four weeks. The measurements were performed for the range of thoracic segmental motion(SpinalMouse), the pain(visual analogue scale) and the range of cervical joint motion(Inclinometer, Dualer IQ). They were made four times: before experiment, at 2weeks, 4weeks, and 4weeks after experiment.

Impact of Firefighters' Protective Clothing and Equipment on Upper Body Range of Motion (소방용 방화복 및 방화 장비에 따른 상반신 관절 각도의 동작 범위 연구)

  • Kim, Seonyoung;Park, Huiju
    • Fashion & Textile Research Journal
    • /
    • v.17 no.4
    • /
    • pp.635-645
    • /
    • 2015
  • This study analyzed the range of motion of upper body in different configurations of firefighters' protective clothing and equipment. The purpose of this study was to understand the influence of firefighters' protective clothing and equipment over upper body motion in order to improve design of firefighters' protective clothing and equipment. 12 firefighters' upper body range of motion was analyzed while performing standing and walking trials in five different garment configurations including turnout ensemble, fire boots and the self-contained breathing apparatus. Analysis of upper body range of motion included spinal joints of L5S1, L4L3, T1C7, and C1Head. During standing trials, garment configurations caused a significant difference in range of motions at joints of L5S1, L4L3, T1C7, and C1Head. Analysis on the mean of range of motions at L5S1 and L4L3, showed that firefighters' waist bent forward significantly to a greater extent while they wore a self-contained breathing apparatus. A significantly increased range of motion was found for T1C7 and C1Head while carrying a self-contained breathing apparatus, which indicated an increase in the extension of the trunk and neck backward to stand upright and look squarely. A significant difference in range of motion was also found for L5S1 and L4L3 during walking trials.

The Effect of Medio-lateral Balance to Head Rotation in Stroke Patient (뇌졸중 환자의 머리회전 각도가 내.외측 균형에 미치는 영향)

  • Lee, Kwan-Sub;Kim, Chung-Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.5
    • /
    • pp.334-339
    • /
    • 2012
  • Purpose: This study was conducted in order to compare the ability to control postural sway during perturbation when stroke patients received postural sway induced by head rotation. Methods: This study included 15 stroke patients and 15 healthy adults. Each group was measured by 3D motion analysis for determination of the angle of the neck in static position and by balance performance monitor for estimation of swaying angle in both neutral posture and head rotation position. These results were then analyzed in order to compare the healthy control group and the stroke patients group. Results: In both static posture ($60.7{\pm}4.81$) and dynamic posture ($51.46{\pm}6.87$, $70.8{\pm}6.55$), significant decreases were observed in the angle of head rotation of the patient group, compared to the healthy group (p<0.05), and significant decreases were observed in the sway angle of the patient group when in the neutral position ($3.62{\pm}7$, $24{\pm}0.60$) and head rotation ($3.04{\pm}0.80$, $51.46{\pm}6.87$), compared to the healthy group (p<0.05). Conclusion: According to these findings, patients with stroke tend to restrict the ROM of head rotation and swaying angle in dynamic posture and maintain their posture instability using limitation of head movement relative to the trunk and sway angle of area which is larger than that of affected side in unaffected side.

A review on measuring cervical range of motion using an inertial measurement unit (관성측정장치를 이용한 경추 가동범위 측정에 대한 고찰)

  • Yim, Juhyuk;Kim, Hyunho;Park, Young-Jae;Park, Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.38 no.1
    • /
    • pp.56-71
    • /
    • 2017
  • Objectives: The purpose of this study was to review the article using an IMU(Inertial Measurement Unit) for measuring the cervical range of motion and to evaluate the feasibility of using an IMU for measuring the cervical range of motion. Method: Scopus was used to search for the articles relating to the inclusion criteria. Which is measuring the cervical range of motion using an IMU. A total of 15 articles were selected through discussion. Degree and the reliability of the cervical range of motion and the validity of the data within the articles were extracted. Results: The measurement of the cervical range of motion using an IMU were $92.25^{\circ}$ to $138.2^{\circ}$, $122.4^{\circ}$ to $154.9^{\circ}$, $73.75^{\circ}$ to $93.1^{\circ}$ on the sagittal plane, transverse plane, and coronal plane respectively. 38 of the 43 values showed good reliability. They were larger than 0.75. 5 of the 43 values showed reliability less than 0.75. They were measured by smart phone. 16 of the 21 values showed good validity. The remaining 5 were measured by smart phone. The lower reliability and validity of smart phone were related to the protocol. The IMU can measure the coupling motion and may be used in various situations. Conclusion: The IMU may become a gold standard for measuring the cervical range of motion. The IMU measured not only the cervical range of motion but also the coupling motion. Furthermore, IMU may be used in various situations. Therefore, IMU must be considered a valuable measurement device.

The clinical study on one case of cervical sprain patient due to traffic accident in pregnancy (임신 중 교통사고로 인한 경추 염좌 환자 1례 증례보고)

  • Baek, Seung-hun;Na, Hyo-seok;Park, Hyun-jae;Jung, Eun-a;Choi, Soon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.18 no.1
    • /
    • pp.207-217
    • /
    • 2005
  • Purpose : With the development of society, traffic accident(TA) rate is increasing accordingly. And the number of women in pregnancy who are damaged by TA is increasing as more women are involved in economical and social activities. TA victim in pregnancy cannot get proper treatment(Tx) in western medicine. Oriental medicine Tx is noted as alternative in treating TA victims recently. The main purpose of this clinical study is to make a survey of effective way of the oriental gynecological Tx about TA victim in pregnancy. Methods : The patient in this case, 28-year-old, was admitted for 14days(27th/May/2004 - 9th/June/2004) to cure severe neck pain and limitaion of cervical ROM(range of motion) occured from TA on the 4th week of pregnancy. This patient was treated with the acupunture, herbal medicine and physical treatment. Result and Conclusion : The symptoms of patient in this case are remarkable alleviated. And we think that the TA victims in pregnancy can be managed effectively by oriental gynecological Tx due to consider preservation of fetus and pregnant woman. After this, further study, approach and case will be needed about oriental gynecological Tx of TA victims in pregnancy.

  • PDF

Invasive Thymoma Originating from Right Pleura with Normal Thymus A case Report (흉막에서 발생한 침습성 흉선종,정상 흉선을 가진 예)

  • 박희철;옥창석
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1381-1384
    • /
    • 1996
  • Thymoma Is an anterior mediastinal tumor, arising from the thymus, but occasionally has ectopic focus such as neck, trachea, thyroid, pulmonary hilum, lung parenchyme and pleura. Forty-two year old male patient was admitted due to progressive development of shortness of breath in 4 months. He had a history of exposure to asbestos for About 10 years duration In recent 15 years. Radiologically, multiple pleural masses were seen rom apex to diaphrAgm, with no evidence of anterior mediastinal mass,with fluid in right pleural cavity. Closed thoracotomy drainage with open biopsy were performed. Effusion cell block showed many T cell marker positive Lymphocytes & some epithelial cells compatible with thymoma, and the tissue also showed cortical type thymoma. Pleuropneumonectomy and thymectomy followed by 60 Gy radiation therapy were done and the patient is well 8 months postoperatively. The pleura is markedly thickened by the invasion of thymoma and the interstitial space of the lung tissue,but the normal appearance of thymus was present in remote area (Masaoka classification IVa). We report a case of ectopic invasive thymoma arising from the right pleura with intact thymus.

  • PDF

Improvement of the Elbow Function with Early Mobilization and Rigid Fixation of Coronoid Fracture by Tension Band Technique (압박 긴장대 방법을 이용한 구상 돌기 골절의 견고한 고정과 조기 운동을 통한 주관절 기능의 향상)

  • Rhyou, In-Hyeok;Suh, Bo-Gun;Kim, Hyung-Jin;Chung, Chae-Ik;Kim, Kyung-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.159-166
    • /
    • 2009
  • Purpose: We wanted to evaluate the surgical results of early mobilization after rigid fixation of small coronoid fracture using the tension band technique Materials and Methods: Eight cases of coronoid fracture were fixed with the tension band technique and using K-wire and wire through the medial approach. All the cases were Regan-Morrey type 2. According to O'Driscoll, they were classified as 5 cases of the tip type (subtype 2) and 3 cases of the anteromedial type (1 case of subtype 2, and 2 case of subtype 3). The associated collateral ligament injuries (6 cases) and radial head/neck fractures (4 cases) were managed simultaneously. After immobilization for 5~7 days, active ROM exercise with a fitted hinge brace started and continued till postoperative 6 weeks. The patients were assessed for pain, ROM and functional disability using the Mayo elbow performance score (MEPS) at an average of 11 months (range: 6~28 months). The ulnar nerve symptoms were also investigated. Results: We observed solid union in all the coronoid fractures without hardware failure. An average of 2.2 wires (range: 2~4) were used. The mean extension was $3^{\circ}$(range: $0^{\circ}\sim25^{\circ}$), the mean flexion was $137^{\circ}$(range: $130^{\circ}\sim140^{\circ}$), the mean pronation was $69^{\circ}$(range: $45^{\circ}\sim90^{\circ}$) and the mean supination was $78^{\circ}$(range: $45^{\circ}\sim90^{\circ}$). The mean MEPS was 96 (range: 65~100). Ulnar nerve symptoms occurred at postoperative one day and persisted in one patient with the terrible triad of taking radial head excision and residual medial instability. Conclusion: The tension band technique uses easily obtained, economic K-wires and the wire was strong enough to permit early elbow ROM exercise and the technique might improve the elbow function. It was especially useful for fixation of multiple small fragments.

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

Effect of Duck's Feet Derived Collagen Sponge on Skin Regeneration: In Vitro Study (오리발 유래 콜라겐 스펀지의 피부재생 효과: In vitro 연구)

  • Cha, Se Rom;Jeong, Hyun Ki;Kim, Su Young;Kim, Eun Young;Song, Jeong Eun;Park, Chan Hum;Kwon, Soon Yong;Khang, Gilson
    • Polymer(Korea)
    • /
    • v.39 no.3
    • /
    • pp.493-498
    • /
    • 2015
  • For biomaterials for skin regeneration with minimized inflammatory response, high bioactivity and biocompatibility are highly required. Also, it should have a porous microstructure to improve cell adhesion and growth. In this study, we extracted a new collagen source from duck's feet which is by-product, and made the shape of sponges from duck's feet collagen (DC) to compare with DBP and SIS. To analyze physical and chemical property of the scaffold, SEM and FTIR were used. MTT assay was used to measure the attachment and proliferation of NIH/3T3 in the scaffolds. RTPCR was used to evaluate the expression of proinflammatory cytokine. Also, 1,1-diphenyl-2-picrylhydrazyl (DPPH) was used to measure the ability of antioxidant activity. Overall, this study shows that DC scaffold is biocompatible and has good physical property. Additionally, DC scaffold shows the potential as wound healing biomaterials.

MRI Predictors of Malignant Transformation in Patients with Inverted Papilloma: A Decision Tree Analysis Using Conventional Imaging Features and Histogram Analysis of Apparent Diffusion Coefficients

  • Chong Hyun Suh;Jeong Hyun Lee;Mi Sun Chung;Xiao Quan Xu;Yu Sub Sung;Sae Rom Chung;Young Jun Choi;Jung Hwan Baek
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.751-758
    • /
    • 2021
  • Objective: Preoperative differentiation between inverted papilloma (IP) and its malignant transformation to squamous cell carcinoma (IP-SCC) is critical for patient management. We aimed to determine the diagnostic accuracy of conventional imaging features and histogram parameters obtained from whole tumor apparent diffusion coefficient (ADC) values to predict IP-SCC in patients with IP, using decision tree analysis. Materials and Methods: In this retrospective study, we analyzed data generated from the records of 180 consecutive patients with histopathologically diagnosed IP or IP-SCC who underwent head and neck magnetic resonance imaging, including diffusion-weighted imaging and 62 patients were included in the study. To obtain whole tumor ADC values, the region of interest was placed to cover the entire volume of the tumor. Classification and regression tree analyses were performed to determine the most significant predictors of IP-SCC among multiple covariates. The final tree was selected by cross-validation pruning based on minimal error. Results: Of 62 patients with IP, 21 (34%) had IP-SCC. The decision tree analysis revealed that the loss of convoluted cerebriform pattern and the 20th percentile cutoff of ADC were the most significant predictors of IP-SCC. With these decision trees, the sensitivity, specificity, accuracy, and C-statistics were 86% (18 out of 21; 95% confidence interval [CI], 65-95%), 100% (41 out of 41; 95% CI, 91-100%), 95% (59 out of 61; 95% CI, 87-98%), and 0.966 (95% CI, 0.912-1.000), respectively. Conclusion: Decision tree analysis using conventional imaging features and histogram analysis of whole volume ADC could predict IP-SCC in patients with IP with high diagnostic accuracy.