• Title/Summary/Keyword: Neck Muscle

Search Result 597, Processing Time 0.02 seconds

The comparative Study of the Acoustic Representation between Pansori singer's and Spasmodic dysphonia patient's Voice (병적인 소리 떨림증과 소리꾼 떨림증의 음향학적인 비교연구)

  • Hong, K.H.;Kim, H.G.;Lee, J.K.;Choi, J.S.
    • Proceedings of the KSPS conference
    • /
    • 2007.05a
    • /
    • pp.143-145
    • /
    • 2007
  • Muscle groups that are located in and around the vocal tract can produce audible changes in frequency and/or intensity of the voice. Vocal vibrato is a characteristic feature in the singing of performers trained in the western classical tradition and vibrato is generally considered to result from modulation in frequency amplitude and timbre. Vocal tremor is also characterized by periodic fluctuations in the voice frequency or intensity and vocal tremor is symptom of a neurological disease as Spasmodic dysphonia , Parkinson's disease. Vocal vibrato and Vocal tremor may have many of the same origins and mechanisms in the voice production systems. The purpose of this study is to find acostic character of Korean traditional song Pansori singer's vibrato and Spasmodic dysphonia patient's vocal tremor. twelve Pansori singers and seven Spasmodic dysponia patients participated to this study. Power spectrum and Real time Spectrogram are used to analyze the acoustic characteristics of Pansori singing and Spasmodic dysphonia patient's voice The results are as follows; First, vowel formant differences between Pansori singing and Spasmodic dysphonia patient's voice are higher F1, F3. Second, The vibrato rate show differences between Pansori singing and Spasmodic dysphonia patients;$4^{\sim}6/sec$ and $5{\sim}6/sec$ Vibrato rate of pitch is 5.7 Hz ${\sim}$ 42.4 Hz for Pansori singing , 3.8 Hz ${\sim}$ 27.9 Hz for Spasmodic dysphonia patients ;Vibrato rate of intensity range is 0.07 dB ${\sim}$ 8.26 dB for Pansori singing and 0.07 dB ${\sim}$ 4.81 dB for Spasmodic dysphonia patients

  • PDF

Development and Evaluation of Smart Jacket with Embedded Wearable Device (웨어러블 디바이스를 이용한 기능성 스마트 재킷 개발 및 평가)

  • Lee, Jeong-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.3
    • /
    • pp.395-407
    • /
    • 2008
  • As global interest in clothing spreads over the smart clothing which arouses high added-value in the apparel industry, this study is to develop a smart jacket with an electrically-vibrating device maintaining excellent appearance and comfort. The vibrating device has a massage function that could relieve muscle pain near shoulders and neck. The purposes of this research are to develop jacket pattern for men in their thirties considering body shapes and fashion trend, to develop a wearable device that is composed of motor and controller and integrate it into a jacket, and to assess the external appearance and functional satisfaction of the smart jacket through the wearing test. The results are as follows: 1. In order to develope an appropriate jacket pattern for men in their thirties, several patterns were assessed for their fitting comfort. The final pattern was completed after making alterations some parts, and showed high satisfaction as 3.6(on a five-point scale) in all categories. 2. A vibrating device was developed by connecting motor, controller, battery and switch. Developing this device, focus was maximizing the strength of motor and minimizing the heat generated from motor and controller. Snaps were placed between inner and outer cloth of jacket so that the vibrating device could be easily attachable and detachable. The motor was located around Trapezius where muscles often get stiff. A switch was designed to be used in selecting the modes of Strong, Weak, and Cross Tapping. 3. The wearing test was conducted to examine outer appearance, comfort for motion, and functionality of the smart jacket. The results of assessing outer appearance showed that the location for attaching the vibrating device was not noticeable but looked natural, and there is almost no change in outer appearance when the vibrating device operates. The result of assessing comfort of action revealed that wearer's satisfaction was high in all categories about activity, wearer's comfort, etc. The result also showed that wear's satisfaction for effects of vibrating massage, easiness in using the device, heat generation was not less than 3.5 in all categories except a category about noise.

Corrective Surgery of Congenital Cardiac Anomalies in the Noonan syndrome - Report of two cases - (Noonan 증후군에 동반된 심기형의 수술적 교정 - 2례 보고 -)

  • 이선희;이주현;심성보;박재길;곽문섭;김세화;오용석;윤호중;정욱성
    • Journal of Chest Surgery
    • /
    • v.34 no.7
    • /
    • pp.552-555
    • /
    • 2001
  • Noonan syndrome is characterized by a Turner-like phenotype and a normal karyotype associated with congenital abnormalities, such as short stature, variable mental retardation, hypertelorism, webbed neck, low posterior hair line, skeletal malformation and congenital cardiovascular defect. Two third of Noonan syndrome have cardiac anormalies, half with pulmonary stenosis. We have experienced two cases of pulmonary stenosis associated with other cardiac anomalies in Noonan syndrome. The first 31-year-old male patient had characteristic appearance of Noonan syndrome with severe infundibular pulmonic stenosis and patent foramen ovate. The second 28-year-old male patient had valvular and subvalvular Pulmonary stenosis with typical Noonan\`s face and stature. Pulmonary valvotomy and hypertrophied muscle bundles in the right ventricular cavity were resected in both cases. Patent foramen ovate was closed directly in the first case. Postoperative follow-up examinations revealed no symptoms and successful outcome.

  • PDF

Study on Body Circumference Ratio according to Sasang Constitution Using Body Composition (체성분 분석을 통한 사상체질의 신체 둘레 비율에 대한 연구)

  • Kang, Ju-No;Cha, Yun-Yeop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.2
    • /
    • pp.338-344
    • /
    • 2010
  • The purpose of this study was to find the charateristics of Sasang Constitution, Soeumin, Soyangin and Taeumin from the result of body Circumference ratio. In this study, 324 data of body circumference were measured by body composition analysis. We analyzed the body circumference ratio by Sasang Constitution, Soeumin, Soyangin and Taeumin. Taeumin's body circumference were significantly higher than those of Soeumin and Soyangin. Soyangin's body circumference was significantly higher than that of Soeumin. Male Taeumin's muscle circumference were significantly higher than those of male Soyangin and male Soeumin. Female Taeumin's fat thickness were significantly higher than those of female Soyangin and female Soeumin. Male Soeumin's ratio of hip circumference and neck circumference to abdomen circumference were significantly higher than those of male Taeumin and male Soyangin. Male Taeumin's ratio of hip circumference to abdomen circumference were significantly lower than those of male Soeumin and male Soyangin. Female Taeumin's ratio of hip circumference and chest circumference to abdomen circumference were significantly lower than those of female Taeumin and female Soyangin. In body circumference ratio, Soyangin had no difference among Sasang Constitution. In body circumference ratio, male Soeumin had big lower area ratio and big upper area ratio to lower-middle area. Male Taeumin had big lower-middle area ratio to lower area. Female Taeumin had big lower-middle area ratio to lower area and upper-middle area.

Development and Assessment of Shovel Applying Foothold

  • Lim, Cheolmin;Lee, Kyungsuk;Kim, Kyungran;Kim, Hyocher;Seo, Mintae;Kim, Seongwoo;Chae, Hyeseon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.2
    • /
    • pp.67-74
    • /
    • 2016
  • Objective: The aim of this study is to develop a farming shovel to reduce workload, which helps farmers lower the risk of musculoskeletal disease. Background: Most of work using farming tools including shovels requires repetitive works and awkward postures on body parts, and it could possibly cause work-related musculoskeletal disorders. It is necessary to develop and distribute farm equipment and tools in order to reduce physical workload. Method: To improve the most uncomfortable task perceived by ten farmers during the work with a shovel, the improved shovel was designed and made as a prototype for experiment for the comparison of the existing and improved shovels. Twenty males were recruited for this experiment, and muscle activity (%MVC) of six body parts and subjective discomfort ratings by body parts while working with a shovel were measured. A paired t-test was performed to compare physical workload between the existing shovel and the developed one. Results: A shovel applying foothold tied between shaft and blade was designed, which can help workers reduce repetitive bending of back and pressures for upper limbs while digging soil. According to compared evaluation of the developed shovel and the existing shovel, the developed shovel's %MVCs in all experimental muscles were significantly lower than those of the existing shovel. The developed shovel showed the biggest drop in perceived subjective discomfort rating of back, followed by arm and neck, compared to the existing shovel. Conclusion: It was confirmed that attaching a foothold to a shovel was an effective way of reducing workload in back and upper limbs during digging. Application: In the near future, if we put the prototype of developed shovel to practical use after making up for defects, it will help farm work environment be healthier and safer.

Effect of E10 on Relief of Cervical Myalgia; One Group Pre-Post, Pilot Trial Study (E10의 경항부 근육통 완화에 대한 효과; 전-후 비교, 예비 임상 연구)

  • Jung, Dong-Hoon;Kim, Hye-Jung;Kim, Jung-Sup;Lee, Gui-Sun;Park, Won-Hyung;Cha, Yun-Yeop
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.3
    • /
    • pp.119-128
    • /
    • 2016
  • Objectives The purpose of this study is to investigate the efficacy of E10 on the relief of cervical myalgia. Methods This study is a one group pre-post, pilot trial test. After the approval of institutional review board (IRB), we have recruited 25 patients suffering from cervical myalgia. 23 patients (2 patients dropped out) was treated by using E10 on the cervical muscle and acupuncture points, three times a week for a total of two weeks from February 2016 to April 2016. Evaluations of VAS for bothersomeness of neck pain (VASB), VAS for pain intensity (VASP), NDI, SF-36, X-ray, thermography, etc. before and 1 week after treatment were carried out. The primary outcome measure was the VASB, measured 1 week after the end of the therapy. Results VASB scores was significantly decreased from $72.5{\pm}9.9$ to $50.4{\pm}9.9$. VASP scores was significantly decreased from $71.5{\pm}10.5$ to $48.5{\pm}18.3$. Results showed significant improvements in VASB, VASP, NDI, SF-36 from the baseline. However, in X-ray, thermography, there was no singnificant difference. Conclusions This study demonstrates the effectiveness of E10 treatment for relieving cervical myalgia.

Traumatic ulcerative granuloma misjudged as oral squamous cell carcinoma (SCC) on the buccal cheek: case report (편평세포암종으로 오인된 협부에 발생한 간질 호산구 증다증을 동반한 외상성 궤양성 육아종: 증례보고)

  • Kwon, Jin-Il;Kim, Hyun-Woo;Nam, Woong;Cha, In-Ho;Kim, Hyung-Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.3
    • /
    • pp.217-220
    • /
    • 2010
  • Traumatic ulcerative granuloma with stromal eosinophilia (TUGSE) is an ulcerative lesion on oral mucosa featuring as a benign mass of self-limiting growth. It can be easily misdiagnosed as squamous cell carcinoma (SCC) due to its long healing period and elevated or rolled-up margin. A 57-year old male patient who visited our department was diagnosed as SCC according to the clinical features, results of positron emission tomography (PET) and magnetic resonance imaging (MRI) of the oral lesion. However, after performing incisional biopsy, histopathologically, there were no atypical cells, but eosinophil and CD 30+ T-cells were clustered in subcutaneous and muscle tissue. It is very significant to consider this reactive lesion in the field of oral and maxillofacial surgery because of its possibility of mistaken as malignant disease. Here, we will report a couple of cases of TUGSE with references and limit of radiographic tools used for diagnosis of head and neck cancer.

Arm Cortex S3C2440 Microcontroller Application for Transcranial Magnetic Stimulation's Pulse Forming on Bax Reactive Cells and Cell Death in Ischemia Induced Rats

  • Tac, Han-Ho;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.266-272
    • /
    • 2016
  • Transcranial magnetic stimulation devices has been used mainly for diagnostic purposes by measuring the functions of the nervous system rather than for treatment purposes, and has a problem of considerable energy fluctuations per repeated pulse. The majority of strokes are caused by ischemia and result in brain tissue damage, leading to problems of the central nervous system including hemiparesis, dysfunction of language and consciousness, and dysfunction of perception. Control is difficult and the size is large due to the difficulty of digitalizing the energy stored in a capacitor, and there are many heavy devices. In addition, there are many constraints when it is used for a range of purposes such as head and neck diagnosis, treatment and rehabilitation of nerve palsy, muscle strengthening, treatment of urinary incontinence etc. Output stabilization and minimization of the energy variation rate are required as the level of the transcranial magnetic stimulation device is dramatically improved and the demand for therapeutic purposes increases. This study developed a compact, low cost transcranial magnetic stimulation device with minimal energy variation of a high repeated pulse and output stabilization using a real time capacitor charge discharge voltage. Ischemia was induced in male SD rats by closing off the common carotid artery for 5 minutes, after which the blood was re-perfused. In the cerebrum, the number of PARP reactive cells after 24 hours significantly decreased (p < 0.05) in the TMS group compared to the GI group. As a result, TMS showed the greatest effect on necrosis-related PARP immuno-reactive cells 24 hours after ischemia, indicating necrosis inhibition, blocking of neural cell death, and protection of neural cells.

The Effect of Bee Venom Acupuncture into Chok-samni (ST36) on Neuronal Activity in the Spinal Cord (족삼리(足三里) 봉독약침자극(蜂毒藥鍼刺戟)이 척수내(脊髓內) Fos 양성반응(陽性反應) 신경세포(神經細胞)의 활성(活性)에 미치는 영향(影響))

  • Yim, Yun-Kyoung;Kang, Sung-Keel;Choi, Do-Young
    • Journal of Pharmacopuncture
    • /
    • v.3 no.1
    • /
    • pp.141-155
    • /
    • 2000
  • This study was designed to evaluate the analgesic effect of bee venom (BV) Acupuncture into different treatment points, Chok-samni (ST36) and blank loci of the gluteal muscle and back. We investigated neuronal activity in the spinal cord using the Fos immunohistochemical technique according to the pretreatment with different concentrations of BV, thirty minutes before the formalin injection. The results were summarized as follows: 1. The number of Fos-like immunoreactive (Fos-LI) neurons in L2 segment of the saline-formalin treated group was significantly increased in NECK and VENT of the spinal cord as compared with that of the room control group. However, there was no significant change in the number of the Fos-LI neurons in L2 segment of the BV-formalin treated group as compared with that of the room control group. 2. The number of Fos-LI neurons in L3-5 segment of the saline-formalin group was significantly increased in all the regions of 142 the spinal cord as compared with that of the room control group. However, the Fos-LI neurons in L3-5 segment of the BV-formalin treated group was dramatically decreased in all the regions of the spinal cord as compared with that of the saline-formalin group. Therefore, these results indicated that the BV acupuncture suppressed the nociceptive neuronal activities in L3-5 of the spinal cord induced by formalin injection. 3. There was a strong positive correlation between the formalin-induced pain behavior and the number of the Fos-LI neurons in L3-5 segment.

Assessments of Physical Workload in Sonography Tasks Using Inclinometry, Goniometry, and Electromyography

  • Simonsen, Jenny Gremark;Dahlqvist, Camilla;Enquist, Henrik;Nordander, Catarina;Axmon, Anna;Arvidsson, Inger
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.326-333
    • /
    • 2018
  • Background: Echocardiography involves strenuous postures of the upper limbs. This study explored the physical workload in the neck and upper limbs in sonographers performing echocardiography, and the extent to which the workload differs from than in other work tasks (other sonographic examinations, and nonsonographic tasks). Methods: The physical load was assessed by inclinometry, goniometry, and electromyography methods in 33 female sonographers during authentic work using three different echocardiography techniques and other work tasks. Results: Echocardiography was characterized by low velocities of the head, arms, and wrists, and a low proportion of muscular resting time in the forearms, in the transducer limb, and the computer limb. The transducer limb was more elevated in one of the techniques, but this technique also involved a higher proportion of muscular resting time of the trapezius muscle. We also found a high proportion of awkward wrist postures in the transducer wrist in all three techniques; in one due to prolonged flexion, and in the others due to prolonged extension. Other work tasks were less static, and were performed with higher upper arm and wrist velocities. Conclusion: None of the three echocardiography techniques was optimal concerning physical workload. Thus, to achieve more variation in physical load we recommend that the equipment be arranged so that the sonographer can alternate between two different techniques during the workday. We also propose alternation between echocardiography and nonsonographic tasks, in order to introduce variation in the physical workload. Clinical expertise should be used to achieve further improvements.