• Title/Summary/Keyword: Near-infrared Light

Search Result 255, Processing Time 0.033 seconds

Measurement of Quality Parameters of Honey by Reflectance Spectra

  • Park, Chang-Hyun;Yang, Won-Jun;Sohn, Jae-Hyung;Kim, Jong-Hoon
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1530-1530
    • /
    • 2001
  • The objectives of this study were to develop models to predict quality parameters of Korean bee-honeys by visible and NIR spectroscopic technique. Two kinds of bee-honey fronl acacia and polyflower sources were tested in this study. The honeys were harvested in the spring of 2000 and stored in the storage facility at 20$^{\circ}C$ during experiments. Total of 394 samples of honey were analyzed. Reflectance spectra, moisture contents, ash, invert sugar, sucrose, F/G (fructose/glucose) ratio, HMF (hydroxymethyl furfural), and C12/C13 ratio of honeys were measured. The average values for the tested honeys were 19.9% of moisture contents, 0.12% of ash, 68.4% of invert sugar, 5.7% of sucrose, 1.27 of F/G(fructose/glucose) ratio, 14.4 mg/kg of HMF, and -19.1 of C12/C13 ratio. A spectrophotometer, equipped with a single-beam scanning monochromator (NIR Systems, Model 6500, USA) and a horizontal setup module, was used to collect reflectance data from honey. The reflectance spectra were measured in wavelength ranges of 400∼2,498 nm. with 2 nm of interval. Thirty-two repetitive scans were averaged, transformed to log(1/Reflectance), and then were stored in a microcomputer file, forming one spectrum per measurement. A sample cell and reflectance plate were made to hold honey samples constantly. Spectra of honey samples were divided into a calibration set and a validation set. The calibration set was used during model development, and the validation set was used to predict quality parameters from unknown spectra. The PLS(Partial Least Square) models were developed to predict the quality parameters of honeys. The first and the second derivatives of raw spectra were also used to develop the models with proper smoothing gap. The MSC (multiplicative scatter correction) and the SNV & Dtr.(standard normal variate and detranding) preprocessing were applied to all spectra to minimize sample-to-sample light scatter differences. The PLS models showed good relationships between predicted and measured quality parameters of honeys in the wavelength range of 1100∼2200 nm. However, the PLS analysis was not good enough to predict HMF of honeys.

  • PDF

Preparation and Characterization of Cy5.5-conjugated Biocompatible Polymeric Micellar Nanoparticles for Optical Imaging (광학 영상을 위한 Cy5.5가 결합된 생체적합성 고분자 마이셀 나노입자의 제조 및 특성분석)

  • Kim, Hyo-Jeong;Kim, Byung-Jin;Lee, Ha-Yeong;Jung, Suk Hyun;Jeong, Seo-Young;Yuk, Soon-Hong;Shin, Byung-Cheo;Seong, Ha-Soo;Choi, Youn-Woong;Ha, Dae-Chul;Choi, Sun-Hang;Lee, Soo-Min
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.6
    • /
    • pp.393-400
    • /
    • 2009
  • PHEA (hydroxyethyl-aspartamide)-mPEG (methoy-polyethyleneglycol)-$C_{16}$ (hexadecylamine)-ED (ethylenediamine) was prepared as a drug delivery carrier. The structure and molecular weight of polymers were characterized by $^1H$-NMR and gel permeation chromatography. Micelle size and shape were measured by electro-photometer light scattering and transmission electron microscope. The mean diameter of micelles was 23 nm in aqueous solution. To evaluate the potential of these polymeric micelles as a drug carrier, PSI-mPEG-$C_{16}$-ED was conjugated with Cy5.5 for Near-Infrared Fluorescent (NIRF) based optical imaging. PSI-mPEG-$C_{16}$-ED-Cy5.5 was injected intravenously into mice (n=5) and in vivo NIRF imaging was performed during 48 h after injection. The biodistribution study at 24 h after injection showed the longcirculation property of PSI-mPEG-$C_{16}$-ED-Cy5.5. Therefore, PSI-mPEG-$C_{16}$-ED micelles could be a promising drug carrier and imaging agent.

Assessment of the Completeness of Lymph Node Dissection Using Near-infrared Imaging with Indocyanine Green in Laparoscopic Gastrectomy for Gastric Cancer

  • Kim, Tae-Han;Kong, Seong-Ho;Park, Ji-Ho;Son, Yong-Gil;Huh, Yeon-Ju;Suh, Yun-Suhk;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.18 no.2
    • /
    • pp.161-171
    • /
    • 2018
  • Purpose: This study assessed the feasibility of near-infrared (NIR) imaging with indocyanine green (ICG) in investigating the completeness of laparoscopic lymph node (LN) dissection for gastric cancer. Materials and Methods: Patients scheduled for laparoscopic gastrectomy for treating gastric cancer were enrolled in the study. After intraoperative submucosal ICG injection (0.05 mg/mL), LN dissection was performed under conventional laparoscopic light. After dissection, the LN stations of interest were examined under the NIR mode to locate any extra ICG-stained (E) tissues, which were excised and sent for pathologic confirmation. This technique was tested in 2 steps: infra-pyloric LN dissection (step 1) and review of all stations after proper radical node dissection (step 2). Results: In step 1, 15 patients who underwent laparoscopic pylorus-preserving gastrectomy (LPPG) and 15 patients who underwent laparoscopic distal gastrectomy (LDG) were examined. Seven and 2 E-tissues were obtained during LPPG and LDG, respectively. From the retrieved E-tissues, 1 and 0 tissue obtained during LPPG and LDG, respectively, was confirmed as LN. In step 2, 20 patients were enrolled (13 D1+ dissection and 7 D2 dissection). Six E-tissues were retrieved from 5 patients, and 1 tissue was confirmed as LN in the pathologic review. Overall, 15 E-tissues were detected and removed, and 2 tissues were confirmed as LNs in the pathologic review. Both nodes were from LN station #6, with 1 case each in the LDG and LPPG groups. Conclusions: NIR imaging may provide additional node detection during laparoscopic LN dissection for gastric cancer, especially in the infra-pyloric area.

Evaluation of Near-infrared Fluorescence-conjugated Peptides for Visualization of Human Epidermal Receptor 2-overexpressed Gastric Cancer

  • Jeong, Kyoungyun;Kong, Seong-Ho;Bae, Seong-Woo;Park, Cho Rong;Berlth, Felix;Shin, Jae Hwan;Lee, Yun-Sang;Youn, Hyewon;Koo, Eunhee;Suh, Yun-Suhk;Park, Do Joong;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.21 no.2
    • /
    • pp.191-202
    • /
    • 2021
  • Purpose: A near-infrared (NIR) fluorescence imaging is a promising tool for cancer-specific image guided surgery. Human epidermal receptor 2 (HER2) is one of the candidate markers for gastric cancer. In this study, we aimed to synthesize HER2-specific NIR fluorescence probes and evaluate their applicability in cancer-specific image-guided surgeries using an animal model. Materials and Methods: An NIR dye emitting light at 800 nm (IRDye800CW; Li-COR) was conjugated to trastuzumab and an HER2-specific affibody using a click mechanism. HER2 affinity was assessed using surface plasmon resonance. Gastric cancer cell lines (NCI-N87 and SNU-601) were subcutaneously implanted into female BALB/c nu (6-8 weeks old) mice. After intravenous injection of the probes, biodistribution and fluorescence signal intensity were measured using Lumina II (Perkin Elmer) and a laparoscopic NIR camera (InTheSmart). Results: Trastuzumab-IRDye800CW exhibited high affinity for HER2 (KD=2.093(3) pM). Fluorescence signals in the liver and spleen were the highest at 24 hours post injection, while the signal in HER2-positive tumor cells increased until 72 hours, as assessed using the Lumina II system. The signal corresponding to the tumor was visually identified and clearly differentiated from the liver after 72 hours using a laparoscopic NIR camera. Affibody-IRDye800CW also exhibited high affinity for HER2 (KD=4.71 nM); however, the signal was not identified in the tumor, probably owing to rapid renal clearance. Conclusions: Trastuzumab-IRDye800CW may be used as a potential NIR probe that can be injected 2-3 days before surgery to obtain high HER2-specific signal and contrast. Affibody-based NIR probes may require modifications to enhance mobilization to the tumor site.

A Study on the Implementation and Development of Image Processing Algorithms for Vibes Detection Equipment (정맥 검출 장비 구현 및 영상처리 알고리즘 개발에 대한 연구)

  • Jin-Hyoung, Jeong;Jae-Hyun, Jo;Jee-Hun, Jang;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.463-470
    • /
    • 2022
  • Intravenous injection is widely used for patient treatment, including injection drugs, fluids, parenteral nutrition, and blood products, and is the most frequently performed invasive treatment for inpatients, including blood collection, peripheral catheter insertion, and other IV therapy, and more than 1 billion cases per year. Intravenous injection is one of the difficult procedures performed only by experienced nurses who have been trained in intravenous injection, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Nurses who frequently perform intravenous injections may also make mistakes because it is not easy to detect veins due to factors such as obesity, skin color, and age. Accordingly, studies on auxiliary equipment capable of visualizing the venous structure of the back of the hand or arm have been published to reduce mistakes during intravenous injection. This paper is about the development of venous detection equipment that visualizes venous structure during intravenous injection, and the optimal combination was selected by comparing the brightness of acquired images according to the combination of near-infrared (NIR) LED and Filter with different wavelength bands. In addition, an image processing algorithm was derived to threshehold and making blood vessel part to green through grayscale conversion, histogram equilzation, and sharpening filters for clarity of vein images obtained through the implemented venous detection experimental module.

Effects of High Performance Greenhouse Films on Growth and Fruit Quality of Tomato (기능성 피복재가 토마토 생육 및 품질에 미치는 영향)

  • Kwon, Joon-Kook;Cho, Myeomg-Whan;Kang, Nam-Jun;Kang, Yun-Im;Park, Kyoung-Sub;Lee, Jae-Han
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.232-237
    • /
    • 2009
  • This study was performed to investigate the effect of high performance greenhouse films on growth and fruit quality of tomato. For this purpose, polyolefin (PO), fluoric, antidrop, antifog and thermal films were compared to normal film, ethylene vinyl acetate (EVA). In spectral irradiance of the films, UV ($300{\sim}400nm$) transmittance was highest in fluoric film and lowest in PO film. PAR (photosynthetically active radiation, $400{\sim}700nm$) transmittance was higher in fluoric, thermal and PO film, and near infrared ray (NIR, $700{\sim}1,100nm$) transmittance was higher in high performance films, compared to the EVA film. Total light transmittance was higher in order of fluoric, antifog, anti drop, PO, thermal, and EVA film. Day air temperature in greenhouse was highest under fluoric film and lowest under EVA film due to the light transmittance, while night air temperature was highest under PO and anti drop film due to the thickness of film. Tomato fruits grown under the high performance films had 0.2 to $0.5^{\circ}Bx$ higher soluble solids and 15 to 30% higher lycopene content, compared to those grown under the EVA film. The results showed that tomato fruit quality such as soluble solids and lycopene content can be heightened in terms of much irradiation and better light quality of high performance films, compared to the nomal film, EVA film.

Characteristics and Fabrication of Complementary Electrochromic Device ( I ) (상보형 일렉트로크로믹 소자의 제조 및 특성 ( I ))

  • Lee, S.Y.;Seo, D.K.;Kim, Y.H.;Cho, T.Y.;Chun, H.G.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.24-34
    • /
    • 1997
  • In this study, two different types of complementary electrochromic devices using amorphous $WO_{3}$ films as a working electrode, $V_{2}O_{5}$ film and NiO film as counter electrodes respectively were investigated. For the devices using amorphous and crystalline $V_{2}O_{5}$ films of $100{\sim}150nm$ thickness with $ITO/WO_{3}/LiClO_{4}-PC/V_{2}O_{5}/ITO$ structure, an optical modulation of $50{\sim}60%$ were obtained at a potential range of $1{\sim}2V$. It has been shown that transmittance and reflectance of light could be electrically controlled by low applied voltage. For the devices with $ITO/WO_{3}/LiClO_{4}-PC/NiO/ITO$ structure in which NiO film was deposited by a RF reactive sputtering, the optical modulation in visible light region (${\lambda}=550nm$) and in near infrared light region (${\lambda}=850nm$) were 25% and 30%, respectively.

  • PDF

Development of Prediction Model for Sugar Content of Strawberry Using NIR Spectroscopy (근적외선 분광을 이용한 딸기의 당도예측모델 개발)

  • Son, Jaeryong;Lee, Kangjin;Kang, Sukwon;Yang, Gilmo;Seo, Youngwook
    • Food Engineering Progress
    • /
    • v.13 no.4
    • /
    • pp.297-301
    • /
    • 2009
  • This study was performed to develop a prediction model of sugar content for strawberry. Near-infrared (NIR) spectroscopy has been prevailed for on-line and portable applications for non-invasive quality assessment of intact fruit. This work presents effects of illumination method and coating of reflection surface of light source on prediction result of sugar content. Effect of preprocessing methods was also examined. A low-cost commercially available VIS/NIR spectrometer was used for estimation of total soluble solids content (Brix). To predict sugar contents of strawberry, the best results were obtained with the spectrum data measured under intensive illuminations at three locations induced from the light source with fiber optic bundles. Gold coating of reflection surface of light source lamp gave favorable effect to prediction result. The best results in validation of PLSR model were $r_{SEP}$ = 0.891 and SEP = 0.443 Brix under OSC preprocessing and those of PCR were $r_{SEP}$ = 0.845, SEP $r_{SEP}$= 0.520 Brix, under no preprocessing.

Synthesis and Characteristic Evaluation of Downward Conversion Phosphor for Improving Solar Cell Performance (태양전지 성능향상을 위한 하향변환 형광체의 합성 및 특성평가)

  • Jae-Ho Kim;Ga-Ram Kim;Jin-To Choi;Soo-Jong Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.523-528
    • /
    • 2023
  • The applicability as a material to improve solar cell performance was reviewed by synthesizing a phosphor that emits red wavelengths by a liquid synthesis method using a metal salt aqueous solution and a polymer medium as a starting material. An aqueous solution was prepared using nitrate of metals such as Ca, Zn, Al, and Eu, and a precursor impregnated with starch, a natural polymer, was sintered to synthesize CaZnAlO:Eu phosphor powder. The surface structure and composition analysis of the synthesized CaZnAlO:Eu phosphor powder were analyzed by scanning electron microscope(SEM) and energy-dispersed X-ray spectroscopy(EDS). The crystal structure of CaZnAlO:Eu phosphor particles was analyzed by an X-ray diffraction analyzer (XRD). As a result of measuring the photoluminescence(PL) characteristics of the phosphor, it was confirmed that a red phosphor with a light emitting wavelength of 650-780nm was successfully synthesized. According to SEM and EDS analysis, the synthesized Ca14Zn6Al9.93O35:Eu3+0.07 phosphor powder has a uniform particle size, and Eu ions used as an activator are present. The synthesized CZA:Eu3+ phosphor can be used as a material that can increase the light absorption efficiency of the solar cell by converting ultraviolet or visible light down conversion into a wavelength in the near-infrared region.

Optical Characteristic on the Growth of Centric Diatom, Skeletonema costatum (Grev.) Cleve Isolated from Jinhae Bay in Korea (진해만에서 분리한 중심목 규조류 Skeletonema costatum(Grev.) Cleve의 성장에 미치는 광학적 특성)

  • Oh, Seok-Jin;Kang, In-Seok;Yoon, Yang-Ho;Yang, Han-Soeb
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.2
    • /
    • pp.57-65
    • /
    • 2008
  • The effects of light quality and irradiance on the growth of centric diatom, Skeletonema costatum (Jinhae Bay strain) were investigated in the laboratory. At 20$^{\circ}C$ and 30 psu, the irradiance-growth curve showed the maximum growth rate of 1.17 day$^{-1}$ with half-saturation photon flux density (PFD) (K$_s$) of 92.4 $\mu$mol photons $m^{-2}s^{-1}$, $\mu$=1.17 (I-5.28)/(I+81.8), (r=0.98), and a compensation PFD (I$_0$) was 5.28 $\mu$mol photons $m^{-2}s^{-1}$. The 10 equated to a depth of 3$\sim$5 m from March to May, 11 m in June and 4 m from July to September in Jinhae Bay. These responses suggested that irradiance at the depth near the surface layer in Jinhae Bay would provide favorable conditions for S. costatum. To assess the effects of light (i.e. wavelengths) on the growth, nine wave-lengths were used ranging from near ultraviolet to near-infrared supplied by light emitting diode. At an irradiance level of 25 $\mu$mol photons $m^{-2}s^{-1}$, S. costatum grew under wavelengths of 405, 470, 505, 525, 568 and 644 nm, but did not grow at 590 and 623 nm; whereas S. costatum grew at all wavelengths at 100 $\mu$mol photons $m^{-2}s^{-1}$. This implies that S. costatum is likely to grow well in enclosed water bodies where suspended particles absorbs most of the blue wavelengths, and dominated by yellow-orange wavelengths.