• Title/Summary/Keyword: Near-infrared (NIR) imaging system

Search Result 24, Processing Time 0.026 seconds

Optical Design of a Modified Catadioptric Omnidirectional Optical System for a Capsule Endoscope to Image Simultaneously Front and Side Views on a RGB/NIR CMOS Sensor (RGB/NIR CMOS 센서에서 정면 영상과 측면 영상을 동시에 결상하는 캡슐 내시경용 개선된 반사굴절식 전방위 광학계의 광학 설계)

  • Hong, Young-Gee;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.286-295
    • /
    • 2021
  • A modified catadioptric omnidirectional optical system (MCOOS) using an RGB/NIR CMOS sensor is optically designed for a capsule endoscope with the front field of view (FOV) in visible light (RGB) and side FOV in visible and near-infrared (NIR) light. The front image is captured by the front imaging lens system of the MCOOS, which consists of an additional three lenses arranged behind the secondary mirror of the catadioptric omnidirectional optical system (COOS) and the imaging lens system of the COOS. The side image is properly formed by the COOS. The Nyquist frequencies of the sensor in the RGB and NIR spectra are 90 lp/mm and 180 lp/mm, respectively. The overall length of 12 mm, F-number of 3.5, and two half-angles of front and side half FOV of 70° and 50°-120° of the MCOOS are determined by the design specifications. As a result, a spatial frequency of 154 lp/mm at a modulation transfer function (MTF) of 0.3, a depth of focus (DOF) of -0.051-+0.052 mm, and a cumulative probability of tolerance (CPT) of 99% are obtained from the COOS. Also, the spatial frequency at MTF of 170 lp/mm, DOF of -0.035-0.051 mm, and CPT of 99.9% are attained from the front-imaging lens system of the optimized MCOOS.

Multipoint Process Monitoring System Based on a Near Infrared Ray(NIR) Acousto-Optic Tunable Filter(AOTF)

  • You, Jang-Woo;Kim, Daesuk;Kim, Soohyun;Kong, Hong-Jin;Lee, Yunwoo;Kwak, Yoon-Keun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.105.4-105
    • /
    • 2001
  • This paper describes a newly designed multipoint process monitoring system based on a NIR acousto-optic tunable filter. The NIR multipoint process monitoring system consists of a NIR AOTF device for wavelength selection, an InGaAs array sensor, and a specially designed iin-line type of optical fiber probe. Unlike a FTS(Fourier Transform Spectrometry) or grating based monitoring system, an AOTF has no moving parts, and it can be rapidly tuned to any wavelength in its operating range within microseconds. Thus, the AOTF is advantageous in terms of faster spectral imaging capability and rigidity required for industrial monitoring environment. In the current feasibility evaluation, an enhanced optical fiber probe with 3 monitoring points was used. However, ...

  • PDF

Near-infrared polarimetric study of near-Earth object 252P/LINEAR: An implication of scattered light from the evolved dust particles

  • Kwon, Yuna G.;Ishiguro, Masateru;Kwon, Jungmi;Kuroda, Daisuke;Im, Myungshin;Choi, Changsu;Tamura, Motohide;Nagayama, Takahiro;Kawai, Nobuyuki;Watanabe, Jun-Ichi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.44.2-44.2
    • /
    • 2019
  • Comets, one of the least-altered leftovers from the nascent solar system, have probably preserved the primitive structure inside, whereas their surfaces become modified from the initial states after repetitive orbital revolutions around the Sun. Resurfacing makes the surface drier and more consolidated than the bulk nuclei, creating inert refractory dust layer ("dust mantle"). Near-infrared (NIR; 1.25-2.25 m) polarimetry is theoretically expected to maximize contrast of the porosity between inner fresh and evolved dust particles, by harboring more dust constituents in the single wavelength than the optical; thus, intensifies electromagnetic interaction in dust aggregates. Despite such an advantage, only a few studies have been made in this approach mainly due to the limited accessibility of available facilities. Herein, we present our new multi-band NIR polarimetric study of near-Earth object 252P/LINEAR over 12 days near perihelion, together with the results of optical (0.48-0.80m) imaging observations and backward dynamical simulation of the comet. Based on the results, we will characterize the dust properties of the comet and discuss the possible environmental (temperature and UV radiation) effects that could produce the observed phenomena.

  • PDF

Implementation of Multi-channel Concurrent Detection Homodyne Frequency-domain Diffuse Optical Imaging System (다채널 동시측정을 적용한 호모다인 주파수영역 확산 광 이미징 시스템의 구현)

  • Jun, Young Sik;Baek, Woon Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.1
    • /
    • pp.23-31
    • /
    • 2012
  • In this paper, we developed a frequency-domain diffuse optical imaging (DOI) system for imaging non-invasively using near-infrared (NIR) light sources and detectors. 70-MHz modulation and a homodyne scheme were adopted. By calibration of the coupling coefficients, concurrent detection measurements by 4 detector sets were optimized. We presented experimental reconstruction images of absorption and scattering coefficients in a liquid phantom, located an anomaly in the phantom and determined its optical properties. The images by the multi-channel concurrent detection were improved over the results by single-channel sequential detection. Tomographic slices of absorption and scattering coefficients in the phantom with an anomaly were also presented.

Optical Property Measurements of Optical Phantoms and Honan Tissues Using Frequency-Domain Diffuse Optical Tomography (주파수 영역 확산광 단층촬영 장치를 이용한 광 팬텀 및 인체조직의 광 계수 측정)

  • Ho, Dong-Su;Kwon, Ki-Woon;Eom, Gi-Yun;Lee, Seung-Duk;Kim, Beop-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.229-234
    • /
    • 2007
  • Diffuse optical tomography (DOT) is a relatively new medical imaging modality which uses near infrared light to image large-sized tissues noninvasively. We constructed a frequency-domain DOT system to measure the optical properties of optical phantoms and human tissues. The FD-DOT uses the intensity-modulated infrared light source that illuminates the biological tissues. The phase shift and modulation changes at each detector site are separately processed to measure the optical properties. The absorption and scattering coefficients are separately estimated using inverse algorithms.

A Study of Globular Cluster Systems in the Coma, Fornax, and Virgo Clusters of Galaxies from HST ACS and WFC3/IR Imaging

  • Cho, Hyejeon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.29.1-29.1
    • /
    • 2017
  • I present new near-infrared (NIR) photometry of globular cluster (GC) systems associated to a cD galaxy NGC 4874 in the core of the Coma cluster and 16 early-type galaxies in the Fornax and Virgo clusters of galaxies using the Infrared Channel of the Wide Field Camera 3 (WFC3/IR) on board the Hubble Space Telescope (HST). Combining these high-resolution NIR data with new HST Advanced Camera for Surveys (ACS) optical photometry for NGC 4874 and existing ACS GC catalogs from the ACS Fornax and Virgo Cluster Surveys, I have examined for the first time the GC systems in a statistically significant optical/NIR sample of galaxies spanning a wide range of luminosities and colors. A primary goal of this study is to explore empirically whether the distributions of purely optical and hybrid optical - NIR color indices for extragalactic GCs have different forms and whether the relations between these color indices are nonlinear, indicating that they behave differently with underlying metallicity. I find that some GC systems of large galaxies in our sample show color bimodalities that differ between the optical and optical - NIR colors, in the sense that they have disparate ratios of "blue" and "red" peak GCs, as well as differing ratios in their color dispersions. Consistent with these results, I find empirically that the dependence of hybrid optical-NIR color on purely optical color is nonlinear, with an inflection at intermediate metallicities. These findings underscore the importance of understanding the nature of galaxy-to-galaxy variations in the GC color distributions and color-color relations, as well as the exact forms of the color-metallicity transformations, in interpreting the observational data on GC color bimodality. Our ACS data for NGC 4874 shows that its GC system exhibits a very strong blue tilt, implying a very steep mass-metallicity scaling, and the centroid of this GC system is offset by $4{\pm}1kpc$ from the luminosity center of NGC 4874, in the direction of NGC 4872. Finally, I discuss the asymmetrical GC distribution around a dwarf elliptical galaxy in Coma that has a very high relative velocity with respect to the cluster mean at small clustercentric radius.

  • PDF

ULTRA PRECISION MACHINING FOR ASTRONOMICAL INFRARED OPTICS (천체관측용 적외선 광학계 초정밀 가공)

  • Kim, Geon-Hee;Jin, Ho;Yang, Sun-Chol;Kim, Myung-Sang;Kook, Myung-Ho;Lee, Sung-Ho;Yuk, In-Soo
    • Publications of The Korean Astronomical Society
    • /
    • v.22 no.3
    • /
    • pp.55-61
    • /
    • 2007
  • The KASINICS (Korea Astronomy and Space science Institute Near Infrared Camera System) is a ground-based near-infrared (NIR) imaging instrument. KASINICS has offner relay optics to reduce unwanted infrared light. For the offner optics, we adopted an ultra precision machining process which is installed at KBSI (Korea Basics Science research Institute). Since the offner relay optics is made of aluminum 6061 metal material, we did several tests to reach the specification. We found that a 0.497mm radius nose bite and 220m/min machining speed are best tool and condition to make this offner optics with the precision machine. In this paper, we report the technical method of ultra precision machining and results of the KASINICS offner optics.

Evaluation of Near-infrared Fluorescence-conjugated Peptides for Visualization of Human Epidermal Receptor 2-overexpressed Gastric Cancer

  • Jeong, Kyoungyun;Kong, Seong-Ho;Bae, Seong-Woo;Park, Cho Rong;Berlth, Felix;Shin, Jae Hwan;Lee, Yun-Sang;Youn, Hyewon;Koo, Eunhee;Suh, Yun-Suhk;Park, Do Joong;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.21 no.2
    • /
    • pp.191-202
    • /
    • 2021
  • Purpose: A near-infrared (NIR) fluorescence imaging is a promising tool for cancer-specific image guided surgery. Human epidermal receptor 2 (HER2) is one of the candidate markers for gastric cancer. In this study, we aimed to synthesize HER2-specific NIR fluorescence probes and evaluate their applicability in cancer-specific image-guided surgeries using an animal model. Materials and Methods: An NIR dye emitting light at 800 nm (IRDye800CW; Li-COR) was conjugated to trastuzumab and an HER2-specific affibody using a click mechanism. HER2 affinity was assessed using surface plasmon resonance. Gastric cancer cell lines (NCI-N87 and SNU-601) were subcutaneously implanted into female BALB/c nu (6-8 weeks old) mice. After intravenous injection of the probes, biodistribution and fluorescence signal intensity were measured using Lumina II (Perkin Elmer) and a laparoscopic NIR camera (InTheSmart). Results: Trastuzumab-IRDye800CW exhibited high affinity for HER2 (KD=2.093(3) pM). Fluorescence signals in the liver and spleen were the highest at 24 hours post injection, while the signal in HER2-positive tumor cells increased until 72 hours, as assessed using the Lumina II system. The signal corresponding to the tumor was visually identified and clearly differentiated from the liver after 72 hours using a laparoscopic NIR camera. Affibody-IRDye800CW also exhibited high affinity for HER2 (KD=4.71 nM); however, the signal was not identified in the tumor, probably owing to rapid renal clearance. Conclusions: Trastuzumab-IRDye800CW may be used as a potential NIR probe that can be injected 2-3 days before surgery to obtain high HER2-specific signal and contrast. Affibody-based NIR probes may require modifications to enhance mobilization to the tumor site.

Damage Analysis of CCD Image Sensor Irradiated by Continuous Wave Laser (연속발진 레이저에 의한 CCD 영상센서의 손상 분석)

  • Yoon, Sunghee;Jhang, Kyung-Young;Shin, Wan-Soon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.690-697
    • /
    • 2016
  • EOIS(electro-optical imaging system) is the main target of the laser weapon. Specially, the image sensor will be vulnerable because EOIS focuses the incident laser beam onto the image sensor. Accordingly, the laser-induced damage of the image sensor needs to be identified for the counter-measure against the laser attack. In this study, the laser-induced damage of the CCD image sensor irradiated by the CW(continuous wave) NIR(near infrared) laser was experimentally investigated and mechanisms of those damage occurrences were analyzed. In the experiment, the near infrared CW fiber laser was used as a laser source. As the fluence, which is the product of the irradiance and the irradiation time, increased, the permanent damages such as discoloration and breakdown appeared sequentially. The discoloration occurred when the color filter was damaged and then the breakdown occurred when the photodiode and substrate were damaged. From the experimental results, LIDTs(laser-induced damage thresholds) of damages were roughly determined.

Non-destructive quality prediction of truss tomatoes using hyperspectral reflectance imagery (초분광 영상을 이용한 송이토마토의 비파괴 품질 예측)

  • Kim, Dae-Yong;Cho, Byoung-Kwan;Kim, Young-Sik
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.3
    • /
    • pp.413-420
    • /
    • 2012
  • Spectroscopic measurement method based on visible and near-infrared wavelengths was prominent technology for rapid and non-destructive evaluation of internal quality of fruits. Reflectance measurement was performed to evaluate firmness, soluble solid content, and acid content of truss tomatoes by hyperspectral reflectance imaging system. The Vis/NIR reflectance spectra was acquired from truss tomatoes sorted by 6 ripening stages. The multivariable analysis based on partial least square (PLS) was used to develop regression models with several preporcessing methods, such as smoothing, normalization, multiplicative scatter correction (MSC), and standard normal variate (SNV). The best model was selected in terms of coefficient of determination of calibration ($R_c^2$) and full cross validation ($R_{cv}^2$), and root mean standard error of calibration (RMSEC) and full cross validation (RMSECV). The results of selected models were 0.8976 ($R_p^2$), 6.0207 kgf (RMSEP) with gaussian filter of smoothing, 0.8379 ($R_p^2$), $0.2674^{\circ}Bx$ (RMSEP) with the mean of normalization, and 0.7779 ($R_p^2$), 0.1033% (RMSEP) with median filter of smoothing for firmness, soluble solid content (SSC), and acid content, respectively. Results show that Vis / NIR hyperspectral reflectance imaging technique has good potential for the measurement of internal quality of truss tomato.