• Title/Summary/Keyword: Near-field Measurement

Search Result 351, Processing Time 0.029 seconds

NEAR=FIELD DIFFRACTION PATTERN BY A SPHERICAL AIR CAVITY IN A DIELECTRIC MEDIUM (유전체 매질내에 있는 구형공동에 의한 근거리 회절패턴)

  • 강진섭;라정웅
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.2
    • /
    • pp.19-30
    • /
    • 1995
  • Diffraction patterns of the copolarized and the crosspolarized total electric fields by a spherical air cavity in a dielectric medium are analyzed in the forward near-field region when the wavelength of the incident plane wave is comparable to one half of the cavity radius. It is shown that double nulls and dips of the copolarized and the crosspolarized total electric fields exist in the measurement plane tansverse to the propagating direction of the incident field, and their dependences on the frequency, the distance of the measurement plane, and the measurement angle are analyzed.

  • PDF

Near-Field Rx-Measurement for Active Phased Array of Digital Radar Using Calibration Path (보정 경로를 활용한 디지털 레이더의 능동 위상 배열 근접전계 수신시험)

  • Yu, Je-Woo;Chae, Heeduck;Park, Jongkuk;Lim, Jae-Hwan;Kim, Duckhwan;Jin, Hyoung-Seog;Kim, Han-Saeng
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.504-511
    • /
    • 2016
  • In this paper, the method is proposed that the equivalent result can be obtained by compensating the variation of gain and phase in the comparison with the result of near-field measurement which is obtained in the steady state, although the gain and phase variation of rx-channels occurred in the near-field rx-measurement of digital active phased array antenna. The proposed concept has the time section for monitoring the state of the rx-channels through the calibration path in the measurement timeline, and is the method for compensating the variation of state. For validating the proposed method, the fabricated X-band digital active phased array antenna and the planar near-field measurement facility is utilized. The proposed method is validated in the comparison with the compensated pattern which the unstable state of rx-channels is calibrated and the reference pattern obtained under the steady state of the rx-channels.

Near-field Noise-emission Modeling for Monitoring Multimedia Operations in Mobile Devices

  • Song, Eakhwan;Choi, Jieun;Lee, Young-Jun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.6
    • /
    • pp.440-444
    • /
    • 2016
  • In this paper, an equivalent circuit model for near-field noise emission is proposed to implement a multimedia operation-monitoring system for mobile devices. The proposed model includes a magnetic field probe that captures noise emissions from multimedia components, and a transfer function for near-field noise coupling from a transmission line source to a magnetic field probe. The proposed model was empirically verified with transfer function measurements of near-field noise emissions from 10 kHz to 500 MHz. With the proposed model, a magnetic field probe was optimally designed for noise measurement on a camera module and an audio codec in a mobile device. It was demonstrated that the probe successfully captured the near-field noise emissions, depending on the operating conditions of the multimedia components, with enhanced sensitivity from a conventional reference probe.

A Study on Structural Intensity Measurement of Semi-infinite Beam (반무한보의 진동 인텐시티 계측에 대한 연구)

  • 이덕영;박성태
    • Journal of KSNVE
    • /
    • v.7 no.1
    • /
    • pp.43-53
    • /
    • 1997
  • This paper investigated the practical use for measuring the structural intensity (power flow per width of cross section) in a uniform semi-infinite beam in flexural vibration. The structural intensity is obtained as a vector at a measurement point, One-dimensional structural intensity can be obtained from 4-point cross spectral measurement, or 2-point measurement on the assumption of far field. The measurement errors due to finite difference approximation and phase mismatch of accelerometers are examined. For precise measurements, it would be better to make the value of k$\delta$(wave number x space between accelerometers) between 0.5 and 1.0. Formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained from 2- and 4-point measurement performed at 200mm (near field) and 400mm (far field) apart from excitation point in random excitation. the results are compared with the theoretical values and measured values of input power spectrum in order to verify the accuracy of structural intensity method, 2-point method is suggested as the practical structural intensity method.

  • PDF

Design and Verification of Far-field measurement system for W-band Millimeter-wave Antenna (밀리미터파(W대역) 안테나 측정을 위한 원-전계 측정 시스템 설계 및 검증)

  • Baek, Jong-Gyun;Hwang, In-June;Cho, Chi-Hyun;Joo, Joung-Myoung;Joo, Ji-Han;Park, Jong-Kuk;Kim, Jaesik;Kim, Sosu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.43-50
    • /
    • 2022
  • In this paper, we designed and verified a Far-field measurement system for measuring the performance of an antenna operating in millimeter wave(W-band). For the antenna test, a measurement system should be selected according to the type of antenna, measurement items, measurement environment and period, etc. In the case of near-field measurement, it takes a lot of time because the number of measurement items increases when the antenna has multiple channels or various beams. Such an antenna can reduce the measurement time through Far-field measurement, and only necessary measurement items can be measured. Therefore, this study secured precise alignment of the far-field measurement system using a high-power laser and improved the measurement accuracy by applying a double amplifier system. The designed system was built in the anechoic chamber and verified by comparison with the verified Near-field measurement system.

Enhancement Technologies of Signal-to-Noise Ratio in the Near-Field Scanning Systems (근거리 전자장 스캐닝 시스템의 잡음 대 성능 비 향상 기술)

  • Shin, Youngsan;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.510-513
    • /
    • 2018
  • Recently, EMC (electromagnetic compatibility) becomes very important, which demands the measurement of EMI (electromagnetic interference) in the chip level. NFS (near-field scanning) systems defined in IEC 61967 and IEC 62508 are typical methods to analyze EMI in the chip level. As chips becomes faster, frequency measurement of NFS system should become wideband, but it degrades SNR (singal-to-noise ratio) of the NFP (near-field probe). This paper surveys SNR enhancement technologies of the NFS while maintaining wideband characteristics.

Near-field Measurement of Antenna using Circular Cylindrical Scanning (원통주사법을 이용한 안테나 근역장 측정 방법)

  • 류홍균;조용희
    • The Journal of the Korea Contents Association
    • /
    • v.4 no.2
    • /
    • pp.28-35
    • /
    • 2004
  • The improvement of a near-field measurement for an antenna is investigated. We propose the formula of a circular cylindrical scanning based on the Cartesian coordinate. Proposed algorithm for the circular cylindrical Scanning is compared with the exact solution for a Hertzian dipole antenna, thus confirming that our approach is useful for most practice measurements.

  • PDF

Simultaneous Temperature and Velocity Fields Measurements near the Boiling Point

  • Doh, Deog-Hee;Hwang, Tae-Gyu;Koo, Bon-Young;Kim, Seok-Ro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.531-542
    • /
    • 2007
  • Simultaneous measurement technique for temperature and velocity fields near a heated solid body has been constructed. The measurement system consists of a 3-late CCD color camera, a color image grabber, a 1ighting system, a host computer and a software for the whole quantification process. Thermo Chromic Liquid Crystals (TCLC) was used as temperature sensors. A neural network was used to get a calibration curve between the temperature and the color change of the TCLC in order to enhance the dynamic range of temperature measurement. The velocity field measurement was attained by the use of the fray-level images taken for the flow field, and by introducing the cross-correlation technique. The temperature and the velocity fields of the forced and the natural convective flows neat the surface of a cartridge heater were measured simultaneously with the constructed measurement system.

Measurement of Tire Structural Vibration Noise Using Spatial Transformation of Sound Field Technique (음장의 공간적 변환기법을 이용한 타이어 구조 진동 소음 측정)

  • Kim, Byoung-Sam
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.11-19
    • /
    • 1995
  • The Interaction between tire and road is responsible for the excited vibration of the tire, and It is also important for the sound radiation. In this paper. measurement of tire structural vibration noise from a chassis dynamometer using Spatial Transformation of Sound Field(STSF) technique is studied. STSF involving a scan that uses an array of transducers over a planar surface close to the source is under investigation. From cross spectra measurement during the scan, a principal component representing the sound field is extracted. Any power descriptor of the near field can then be investigated by means of near-field acoustic holography, while the distant field can be determined by application of Helmholtz integral equation. The results of the measurement were used to obtain the radiation sound pattern from the center line of the tire, and to locate the radiation sound generating regions in the vicinity of the tire.

  • PDF

The Enhancement of Antenna Near-Field Measurements Using Near-Field to Far-Field Transform Algorithms Based on the Lorentz Reciprocity Theorem (로렌츠 상호작용 원리와 근역장-원역장 변환 공식을 이용한 안테나 근역장 측정 알고리즘 개선)

  • Cho, Yong-Heui
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.2
    • /
    • pp.51-58
    • /
    • 2006
  • The enhancement of antenna near-field measurements is obtained using a general probe compensation equation based on the Lorentz reciprocity theorem and reciprocity notation. The probe compensation is an essential process of the near-field to far-field transformations. Applying the equation proposed in this paper to a planar scanning for a rectangular horn antenna shows that our near-field radiation pattern is similar to that of a far-field and our theory is very simple to use and suitable for most practical applications.

  • PDF