• Title/Summary/Keyword: NdFeB magnet

Search Result 229, Processing Time 0.023 seconds

Construction and Characteristics Analysis on the Field System of the High Speed Motor by using Permanent Magnet Halbach Array (영구자석 Halbach 배열을 이용한 초고속 모터용 계자시스템의 구성과 특성 해석)

  • Jang, Seok-Myeong;Seo, Jin-Ho;Jeong, Sang-Seop;Choe, Sang-Gyu
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.4
    • /
    • pp.152-160
    • /
    • 1999
  • A high speed motor has been generating a lot of attention due to its performance-more light, thin, short, compact than ordinary motors. But they have low efficiency with high frequency power source because of the iron losses which may produce too much heat as well as the copper losses occurred in the rotor windings. The Halbach array can generate the strong magnetic field systems without additional magnetic materials, therefore the iron losses can be removed. In this paper, the Halbach array is applied to the field system for the high speed motor, and three dimensional FEM is used to analyze the field of the Halbach array considering with the leakage flux. The measured values of flux density are also compared with the FEM analysis. And the magnetic characteristics of the Halbach array field system are compared with those of the conventional field systems such as slot-iron type, PM-iron type. Consequently, it is confirmed that the Halbach array field system is more suitable to the high speed motor because it has high flux density, sinusoidal flux distribution than others.

  • PDF

Bulk Micromachined Vibration Driven Electromagnetic Energy Harvesters for Self-sustainable Wireless Sensor Node Applications

  • Bang, Dong-Hyun;Park, Jae-Yeong
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1320-1327
    • /
    • 2013
  • In this paper, two different electromagnetic energy harvesters using bulk micromachined silicon spiral springs and Polydimethylsiloxane (PDMS) packaging technique have been fabricated, characterized, and compared to generate electrical energy from ultra-low ambient vibrations under 0.3g. The proposed energy harvesters were comprised of a highly miniaturized Neodymium Iron Boron (NdFeB) magnet, silicon spiral spring, multi-turned copper coil, and PDMS housing in order to improve the electrical output powers and reduce their sizes/volumes. When an external vibration moves directly the magnet mounted as a seismic mass at the center of the spiral spring, the mechanical energy of the moving mass is transformed to electrical energy through the 183 turns of solenoid copper coils. The silicon spiral springs were applied to generate high electrical output power by maximizing the deflection of the movable mass at the low level vibrations. The fabricated energy harvesters using these two different spiral springs exhibited the resonant frequencies of 36Hz and 63Hz and the optimal load resistances of $99{\Omega}$ and $55{\Omega}$, respectively. In particular, the energy harvester using the spiral spring with two links exhibited much better linearity characteristics than the one with four links. It generated $29.02{\mu}W$ of output power and 107.3mV of load voltage at the vibration acceleration of 0.3g. It also exhibited power density and normalized power density of $48.37{\mu}W{\cdot}cm-3$ and $537.41{\mu}W{\cdot}cm-3{\cdot}g-2$, respectively. The total volume of the fabricated energy harvesters was $1cm{\times}1cm{\times}0.6cm$ (height).

Effects of Injection Conditions on the Mechanical Properties of Nd-Fe-B Dielectromagnets

  • B.Slusarek;D.Bialo;J.Gromek;T.Kulesza
    • Journal of Magnetics
    • /
    • v.4 no.2
    • /
    • pp.52-54
    • /
    • 1999
  • Injection molding is one of the methods to prepare dielectromagnets-permanent magnets made from hard magnetic powder (or from mixture of powders) bonded by dielectric materials. Magnetic properties of dielectromagnets are worse than those of sintered magnets made from the same hard magnetic powders, but this type of the permanent magnet has many advantages. One of them is simpler technology-easier in comparison to the technology of sintered magnets. The injection molded dielectromagnets do not need any final treatment. This technology permits to control magnetic, thermal and mechanical properties of dielectromagnets. The main chracteristics of dielectormagnets are magnetic properties, however mechanical properties have serious influence onto a range of their applications. The main factors shaping mechanical properties have serious influence onto a range of their applications. The main factors shaping mechanical properties of dielectromagnets are the kind and quantity of resin and the technology. The purpose of this investigateion was to find the correlation between infection conditions and the mechanical properties of dielectromagnets. Influence of two parameters of injection, temperature and pressure on mechanical and magnetic properties of dielectromagnets were not significantly changed. Increasing of pressure of injection also does not influence on mechanical properties of analysed samples, however increasing of temperature of injection significantly improved both compression and bending strength.

  • PDF

A study on the changes in attractive force of magnetic attachments for overdenture

  • Leem, Han-Wool;Cho, In-Ho;Lee, Jong-Hyuk;Choi, Yu-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.9-15
    • /
    • 2016
  • PURPOSE. Although magnetic attachment is used frequently for overdenture, it is reported that attractive force can be decreased by abrasion and corrosion. The purpose of this study was to establish the clinical basis about considerations and long term prognosis of overdenture using magnetic attachments by investigating the change in attractive force of magnetic attachment applied to the patients. MATERIALS AND METHODS. Among the patients treated with overdenture using magnetic attachments in Dankook University Dental Hospital, attractive force records of 61 magnetic attachments of 20 subjects who re-visited from July 2013 to June 2014 were analyzed. Dental magnet tester (Aichi Micro Intelligent Co., Aichi, Japan) was used for measurement. The magnetic attachments used in this study were Magfit IP-B Flat, Magfit DX400, Magfit DX600 and Magfit DX800 (Aichi Steel Co., Aichi, Japan) filled with Neodymium (NdFeB), a rare-earth magnet. RESULTS. Reduction ratio of attractive force had no significant correlation with conditional variables to which attachments were applied, and was higher when the maintenance period was longer (P<.05, r=.361). Reduction ratio of attractive force was significantly higher in the subject group in which attachments were used over 9 years than within 9 years (P<.05). Furthermore, 16.39% of total magnetic attachments showed detachment of keeper or assembly. CONCLUSION. Attractive force of magnetic attachment is maintained regardless of conditional variables and reduction ratio increased as the maintenance period became longer. Further study on adhesive material, attachment method and design improvement to prevent detachment of magnetic attachment is needed.

Orientation and thickness dependence of magnetic levitation force and trapped magnetic field of single grain YBa2Cu3O7-y bulk superconductors

  • Jung, Y.;Go, S.J.;Joo, H.T.;Lee, Y.J.;Park, S.D.;Jun, B.H.;Kim, C.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.1
    • /
    • pp.30-35
    • /
    • 2017
  • The effects of the crystallographic orientation and sample thickness on the magnetic levitation forces (F) and trapped magnetic field (B) of single grain YBCO bulk superconductors were examined. Single grain YBCO samples with a (001), (110) or (100) surface were used as the test samples. The samples used for the force-distance (F-d) measurement were cooled at 77 K without a magnetic field (zero field cooling, ZFC), whereas the samples used for the B measurement were cooled under the external magnetic field of a Nd-B-Fe permanent magnet (field cooling, FC). It was found that F and B of the (001) surface were higher than those of the (110) or (100) surface, which is attributed to the higher critical current density ($J_c$) of the (001) surface. For the (001) samples with t=5-18 mm, the maximum magnetic levitation forces ($F_{max}s$) of the ZFC samples were larger than 40 N. About 80% of the applied magnetic field was trapped in the FC samples. However, the F and B decreased rapidly as t decreased below 5 mm. There exists a critical sample thickness (t=5 mm for the experimental condition of this study) for maintaining the large levitation/trapping properties, which is dependent on the material properties and magnitude of the external magnetic fields.

Magnetic-Shielding Effectiveness Analysis of the Trigger Assembly of Small Arms (소구경 개인화기 격발신호 발생장치의 자기차폐효과 분석)

  • Lee, Kisu;Ahn, Joon Mo;Chae, Je-Wook
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.456-463
    • /
    • 2018
  • With the development of weapon systems by mounting various sensors, it makes important to analyze the precise functioning of sensor to external environment. In the case of small arms with magnetic sensor, the malfunction of small arms might be caused by strong external magnetic fields. In this study, the effects of magnetic sensor on external magnetic fields were analyzed, and optimal magnetic shield and shield structure were designed through M&S. In addition, the magnetic-shielding effectiveness of magnetic sensor in small arms was verified with commercial shielding materials. As a result, it was demonstrated that the Fe-Cu-Si-Nd-B with the structure of multi-layer metallic shields was shown the magnetic-shielding effectiveness of 83 % for an external permanent magnet and 19 % for an alternating magnetic field of 180 dBpT at 60 Hz, respectively.

Electromagnetic Properties of Bulk High-Tc Superconductor (벌크형 초전도체의 전기자기적 특성)

  • Lee, Sang-Heon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.2
    • /
    • pp.111-114
    • /
    • 2017
  • In this research, the development of fabrication technique of bulk YBaCuO superconductors for application was studied. In fluence of $BaZrO_3$ addition on magnetization characteristics of thermal pyrolysis textured YBaCuO superconductor was investigated. Fine $BaZrO_3$ particle were dispersed within the textured YBaCuO matrix by means of the thermal pyrolysis processing. Magnetic levitation force for YBaCuO superconductors were obtained using Nd-B-Fe permanent magnet, at 77 K and at the magnetic field from 0 to 5.3 K gauss. In the unadded superconductor and 5 wt% $BaZrO_3$ addition, anomalous magnetization behavior, which is characterized by the intermediate magnetic field, was observed at 77 K. Critical current density was about few hundreds $A/cm^2$ and the magnetic characteristics increased slightly by addition of $BaZrO_3$ powder. Maximum magnetic force was obtained in the YBaCuO superconducting bulk with 3 wt.% $BaZrO_3$ addition.

Characteristics of the Sealing Pressure of a Magnetic Fluid Shaft Seal for Intra-Cardiac Axial Flow Blood Pumps (심장 내 이식형 축류 혈액 펌프용 자성 유체 축봉의 내압 특성)

  • KIM, Dong-Wook;Mitamura , Yoshinori
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.10
    • /
    • pp.477-482
    • /
    • 2002
  • One of the key technologic requirements for rotary blood pumps is the sealing of the motor shaft. A mechanical seal, a journal bearing, magnetic coupling, and magnetic suspension have been developed, but they have drawbacks such as wear, thrombus formation, and power consumption. A magnetic fluid seal is durable, simple, and non power consumptive. Long-term experiments confirmed these advantages. The seal body was composed of a Nd-Fe-B magnet and two pole pieces; the seal was formed by injecting magnetic fluid into the gap (50${\mu}m$) between the pole pieces and the motor shaft. To contain the ferro-fluid in the seal and to minimize the possibility of magnetic fluid making contact with blood, a shield with a small cavity was attached to the pole piece. While submerged in blood, the sealing pressure of the seal was measured and found to be 31kPa with magnetic fluid LS-40 (saturated magnetization, 24.3 KA/m) at a motor speed of 10,000 rpm and 53kPa under static conditions(0mmHg). The specially designed magnetic fluid seal for keeping liquids out is useful for axial flow blood pumps. The magnetic fluid seal was incorporated into an intra-cardiac axial flow blood pump.

Levitation characteristics of HTS tape stacks

  • Pokrovskiy, S.V.;Ermolaev, Y.S.;Rudnev, I.A.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.1
    • /
    • pp.14-16
    • /
    • 2015
  • Due to the considerable development of the technology of second generation high-temperature superconductors and a significant improvement in their mechanical and transport properties in the last few years it is possible to use HTS tapes in the magnetic levitation systems. The advantages of tapes on a metal substrate as compared with bulk YBCO material primarily in the strength, and the possibility of optimizing the convenience of manufacturing elements of levitation systems. In the present report presents the results of the magnetic levitation force measurements between the stack of HTS tapes containing $n=2{\div}200$ of tapes $12mm{\times}12mm$ and NdFeB permanent magnet in the FC and ZFC regimes. It was found a non- linear dependence of the levitation force from the height of the array of stack in both modes: linear growth at small thickness gives way to flattening and constant at large number of tapes in the stack. Established that the levitation force of stacks comparable to that of bulk samples. The numerical calculations using finite element method showed that without the screening of the applied field the levitation force of the bulk superconductor and the layered superconductor stack with a critical current of tapes increased by the filling factor is exactly the same, and taking into account the screening force slightly different.

The Influence of an Orthogonal Field on Deperming Performance (직교자계가 디펌성능에 미치는 영향)

  • Kim, Ki-Chan;Kim, Young-Hak;Shin, Kwang-Ho;Kim, Hwi-Seok;Yoon, Kwan-Seob;Yang, Chang-Sub
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.359-363
    • /
    • 2011
  • An orthogonal magnetic field is often used for a military vessel in the deperm process such as Flash D deperm protocol and Anhysteretic deperm protocol. The effect of the orthogonal magnetic field on a deperm performance was investigated for a sample with strain-induced magnetization and field-induced magnetization given to different direction. A 70mm wide, 110mm long and 0.25mm thick rectangular steel plate was bent to have U-shape and to generate a strong strain on the bottom region of U-shaped steel plate. Field-induced magnetization was attached by NdFeB permanent magnet. Demagnetization was performed by applying magnetic field with a step decrement from the first field(the first shot) under the action of DC bias field.