• Title/Summary/Keyword: Nd:yag laser

Search Result 1,019, Processing Time 0.025 seconds

Output Characteristics of the Longitudinally Pumped 946 nm Nd:YAG Laser with Laser Diode (반도체 레이저로 종펌핑하를 946 nm Nd:YAG 레이저의 출력 특성)

  • Park, Cha-Gon;Choo, Han-Tae;Kim, Gyu-Ug
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.4
    • /
    • pp.270-273
    • /
    • 2007
  • We have investigated the output characteristics of the 946 nm Nd:YAG laser which is longitudinally pumped by a fiber coupled laser diode. The temperature of a Nd:YAG crystal mount was kept constant by a controller with thermoelectric cooler. As a result, we measured more intense output at a low temperature, and then the maximum output power was measured to be 870 mW when the pumping power and the temperature were 9.95 W and $5^{\circ}C$, respectively. It appeared that output was decreased above 10 W pump power because of the thermal effects in gain medium.

Single Longitudinal Mode Operation of a Pulsed Dye Laser Injection-seeded with a CW Ring Dye Laser (인젝션 록킹 방법에 의한 펄스 색소레이저의 단일 종모우드 발진)

  • 김재완;공홍진;한재원;박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.84-89
    • /
    • 1994
  • A tunable pulsed dye laser was operated in a single longitudinal mode by injection locking with a cw ring dye laser. A doubled Nd:YAG laser was used as the pumping source. Phase sensitive detection technique was applied to maintain the required match between the master laser frequency and the slave resonator cavity length. The fluctuation of the center frequency of the pulsed laser was < 10 MHz, and the pulse duration (FWHM) was 6 ns. The linewidth measured by scanning confocal interferometer was 130 MHz. When pumped by 50 mJ of the doubled Nd:YAG laser, the output energy of the pulsed dye laser was 2 mJ and the peak power was 330 kW. 30 kW.

  • PDF

Characteristics of Laser Surface Hardening for SM45C Medium Carbon Steel using Continuous Wave Nd:YAG Laser (연속파형 Nd:YAG 레이저를 이용한 SM45C 중탄소강의 레이저표면경화 특성)

  • Yoo, Young-Tae;Shin, Ho-Jun;Ahn, Dong-Gu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.51-58
    • /
    • 2005
  • Laser surface hardening technologies have been used to improve characteristics of wear and to enhance the fatigue resistance for automotive parts. The objective of this research work is to investigate the influence of the process parameters, such as power of laser and defocused spot position, on the characteristics of laser heat treatment for the case of SM45C medium carbon steel. CW Nd:YAG laser is selected as the heat source. The optical lens with the elliptical profile is designed to obtain a wide heat treatment area with a uniform hardness. From the results of the experiments, it has been shown that the maximum hardness is approximatly 780 Hv when the power and the travel speed of laser are 1,095 W and 0.6 m/min, respectively. In addition, the hardening width using the elliptical lens was three time larger than that using the defocusing of laser beam.

A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Cervical Cementum (Nd:YAG 레이저조사가 치경부 백악질에 미치는 영향에 관한 주사전자현미경적 연구)

  • Choi, Bok;Lee, Jeong-Yeon;Shin, Keum-back
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.4
    • /
    • pp.415-425
    • /
    • 2000
  • In order to obtain the basic data concerning the optimal lasing conditions in using Nd:YAG laser as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum, the author selected 36 human teeth having no cervical abrasion and caries (; 12 anteriors, 12 premolars. 12 molars) extracted due to periodontal diseases, and divided them into 4 groups as Group I, II, III and IV (; each group of 3 anteriors, 3 premolars, 3 molars), and prepared a cementum specimen with thickness of $1.0mm{\pm}0.2mm$ sectioned longitudinally at the middle of mesio-distal thickness (; Group I) or horizontally at 1mm-2mm below the cemento-enamel junction (; Group II, III, IV) from each tooth of each group by low speed diamond wheel saw, and treated them with 0.5 M ethylene diamine tetraacetic acid (; EDTA, pH=7.4) for 2 minutes for elimination of remnants during tooth-sectioning. And the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (; wavelength 1064nm. pulse duration $120{\mu}sec$, fiber diameter $320{{\mu}m}$) to cementum surfaces in triplicates of one experiment under the following lasing conditions: 1. stationary mode of fiber in contact to cementum surfaces without air-spray (; Group I )/with air-spray (; Group II), 2. unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec without air-spray (; Group III)/with air-spray (; Group IV), 3. energy per pulse (mJ/pulse) [; energy density ($J/cm^{2}$)] in order of 1.0W/10Hz (100J/pulse); $124J/cm^{2}$, 0.5W/10Hz (50mJ/pulse); $62J/cm^{2}$, 0.4W/10Hz (40mJ/pulse); $50J/cm^{2}$, 0.3W/10Hz (30mJ/pulse); $37J/cm^{2}$, 4. exposure time of 1 second. And the author applied the platinum coating on surfaces of cementum specimens, and evaluated the characteristics of ultrastructural change on surfaces of cementum using the scanning electron microscopy. In general the ultrastructural loss of cervical cementum irradiated under the same lasing condition of laser energy density occurred least in specimens of Group IV. And especially, the ultrastructural loss of cervical cementum irradiated under the laser energy density of $37J/cm^{2}$ almost did not occur in specimens of Group IV. Therefore, it is considered that the pulsed Nd:YAG laser should be applied with the lasing conditions of unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec with air-spray and of laser energy density within $37J/cm^{2}$ as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum.

  • PDF

Parametric Study of a Diode Side-Pumped Nd:YAG Laser Using a Diffusive Reflector (난반사체를 이용한 다이오드 횡여기 Nd:YAG 레이저의 매개변수 연구)

  • 이성만;김선국;윤미정;문희종;김현수;고도경;차병헌;이종민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.222-223
    • /
    • 2000
  • 지금까지 gold-coated 반사체, cusp-shaped 반사체, 복합 포물 반사체(CPC), 난반사 공동체 등 다양한 형태의 반사체가 횡펌핑을 이용한 Nd:YAG 레이저의 개발을 위하여 고안되어졌다. 횡여기되는 Nd:YAG 레이저의 광학적 효율은 반사체의 형태, 다이오드 레이저의 파장, Nd:YAG 결정의 지름, Nd$^3$의 도핑농도에 따라 영향을 받는다.$^{(1)}$ 본 연구에서는 고출력의 횡여기 Nd:YAG 레이저를 개발할 목적으로 광여기 공동으로 사용된 난반사 공동체의 내부지름과 레이저 매질인 Nd:YAG 결정의 흡수계수 등 매개변수를 변화시켜 흡수분포와 출력을 계산하였으며, 이러한 매개변수들이 기울기 효율에 미치는 영향을 수치 해석적으로 연구해 보았다. 광선추적법에서 사용한 매개변수 중에서 다이오드 레이저의 파장은 808 nm이고, 반사율은 90%이며, 여기 다이오드 출력은 1080 W이다. 난반사 공동체$^{(2)}$ 의 반사율은 95.7%이고, 결정의 투과율은 90%이며, 결정의 반지름은 2.5 mm이다. 사용된 여기 구조도는 그림 1과 같다. 여기헤드는 Nd:YAG 결정, 난반사 공동체, 그리고 3개의 360 W급 다이오드 어레이들로 구성되어 있다. (중략)

  • PDF

The Scanning Electron Microscopic study on the effect during subgingival calculus removal using Nd:YAG laser (치은연하치석제거술시 Nd : YAG 레이저를 이용한 효과에 관한 주사전자현미경적 연구)

  • Jeon, Yong-Seon;Choi, Byung-Son;Lee, Seok-Cho;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.2
    • /
    • pp.411-424
    • /
    • 1997
  • The purpose of this study was to evaluate in vitro the effects during subgingival calculus removal using Nd:YAG laser. The study group was consisted of 30 teeth with advanced periodontal disease extracted before the start of periodontal therapy. The specimens were divided into 8 different groups : 1) untreated control 2) scaling and root planing only 3) laser treated using 150mJ/pulse, 1sec, 5sec, contact mode 4) laser treated using 200mJ/pulse, 5sec, contact mode 5) laser treated using 150mJ/pulse, 1sec, non-contact mode 6) laser treated using 200mJ/pulse, 5sec, non-contact mode 7) laser treated using l5OmJ/pulse, 1sec, contact mode with water irrigation 8) laser treated using 200mJ/pulse, 5sec, contact mode with water irrigation. All specimens were prepared for evaluation by scanning electron microscopy(SEM). Specimens from Group 2 exhibited a smear layer of scale like texture with parallel instrument tracks resulting from curet use. Specimens treated by contact mode, Group 3 and 4 featured surface changes not observed· in controls such as charring, randomly distributed pitting and crater formation, and melting down of the tooth material and calculus. Specimens treated by noncontact mode, Group 5 and 6 featured similar surface changes observed in contact mode. However, the differences between contact and non-contact groups not significant. Specimens treated by contact mode with water irrigation, Group 7 and 8 featured slight surface change compared to other groups. The results suggested that Nd: YAG laser did not completely remove the subgingival calculus but was possible the application as adjunctive method.

  • PDF