• Title/Summary/Keyword: Nd:yag laser

Search Result 1,019, Processing Time 0.029 seconds

Q-Switched Nd YAG's SHG conversion techniques for a skin diseased treatment (피부질환 치료를 위한 Q-Switched Nd:YAG의 SHG 변환기술)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1141-1149
    • /
    • 2009
  • Pulse style Nd: YAG Laser is suitable in skin remaking treatment, in compliance with the ramp continuous oscillation until of course normal takeoff, the Q-switch and mode motive takeoff the takeoff form which is various is possible and it is coming to be widely used in microsurgery and skin remaking promotion. According to therapeutic objective very it is important to control a energy density. Control of energy density the method which controls the pulse repetition rate of Laser output is mainly used. From the research which it sees pulse style Nd: It will be able to control the pulse repetition rate of YAG, the 2nd harmonic occurrence Laser (second harmonic generation: SHG) with the energy part of the light-wave which is a footnote wave number will hold and nonlinear decision it propagates and is converted by energy of the light-wave which is a footnote wave number the actual condition which and it applies the second harmonic occurrence in compliance with a secondary nonlinearity it leads and until skin deep part therapeutic possibility is the thing it will be able to observe simply.

Sterilization Effect by the Nd:YAG Laser pulse (Nd:YAG 레이저 펄스에 따른 멸균효과)

  • Jeong, Kyeonghwan;Jung, Dongkyung;Park, Jeongkyu;Choi, Hyeonwoo;Seo, Jeongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.695-703
    • /
    • 2020
  • The use of medical devices is increasing due to the development of medical technology. Among medical devices, it is often used in the human body for graft and treatment. Therefore, in medical institutions, various sterilization methods according to the type and material of medical devices are applied to prevent infection. Hydrophosphite (HA) materials are the most popular in bone grafts. We would like to present a sterilization method using Q-switch Nd:YAG laser with high output energy among non-ionizing radiation suitable for small medical devices. In this study, sterilization power was most ideally shown at UV wavelengths of 1.5 W, 266 nm, and 10 pulses. Different wavelength bands; infrared and visible light; showed passive sterilization, and ultraviolet A and C showed differences in sterilization according to the pulse. In laser sterilization were differences that found according to the wavelength bands and pulses.

Influence of process Parameters on the Surface Roughness and the Striation Formation of the Cut Section for the Case of Cutting of CSP 1N Sheet using High Power CW Nd:YAG Laser (고출력 CW Nd:YAG 레이저를 이용한 CSP1N 냉연강판 절단시 공정변수의 절단면 특성에 미치는 영향)

  • Ahn Dong-Gyu;Kim Min-Su;Park Hyung-Jun;Yoo Young-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.7 s.184
    • /
    • pp.30-38
    • /
    • 2006
  • Laser cutting technology is one of flexible rapid manufacturing technologies with various advantageous including a high cutting speed, manufacturing of parts with a complex shape and others. The quality of the cut part and the optimum cutting conditions are highly dependent on the combination of the process parameters. The objective of this research works is to investigate the influence of process parameters, such as power of laser, cutting speed of laser and material thickness, on the surface roughness and the striation formation of the cut section for the case of cutting of CSP 1N sheet using high power Nd:YAG Laser with a continuous wave (CW). In order to find the relationship between process parameters and the surface roughness and the striation formation of the cut section, several experiments are carried out. Through the investigation of the empirical results, it has been shown that the surface roughness is highly related to the striation formation, including the frequency and angle of the striation, of the cut section. From the results of experiments, an optimum cutting speed for each cutting condition has been obtained to improve both the quality of the cut surface and the cutting efficiency.

THE EFFECTS OF EDTA AND PULSED ND:YAG LASER ON APICAL LEAKAGE OF CANAL OBTURATION (EDTA와 Nd:YAG laser가 근관충전 후 치근단 미세누출에 미치는 영향)

  • Kwon, Jin-Soo;Lee, Hee-Joo;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.50-56
    • /
    • 2003
  • The purpose of this study was to evaluate the effects of EDTA and pulsed Nd :YAG laser on apical leak-age of canal obturation. Forty-eight single-rooted teeth were used in this study. The teeth were instrumented up to a size 40 K-file and irrigated with 2.5% NaOCl between each fie size. And the teeth were divided into 4 groups. In group A, the root canals were irrigated with a final flush of 5ml 2.5% NaOCl as a control group. The teeth in group B were irrigated with a final flush of 5ml 17% EDTA. The teeth in group C and D were irradiated by pulsed Nd:YAG laser(laser parameters were set at 1W, 100mJ, 10Hz, and 2W, 100mJ, 20Hz respectively). The results were as follows : 1. Apical leakage was observed in 50% of samples in group A, 30% of samples in group B, 20% of samples in group C, and 10% of samples in group D. 2. The teeth in group B had less leakage than group A, but there was no statistically significant differences(p>0.05). 3. The teeth in group C, D had less leakage than group A, and there was statistically significant differences(p<0.05). 4. The teeth in group C, D had less leakage than group B, but there was no statistically significant differences(p>0.05). 5. There was no significant differences in apical leakage between group C and group D(p>0.05).

Cleaning of Nip Hard Disk Substrate Using Near-Infrared and Ultraviolet Irradiation of Nd:Yag Laser Pulses (Nd:YAG 레이저의 근적외선과 자외선 펄스를 이용한 NiP 하드디스크 기층의 세척)

  • 김동식
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2000.11a
    • /
    • pp.23-26
    • /
    • 2000
  • This paper introduces a cleaning process for removing submicron-sized particles from NiP hard disk substrates by the liquid-assisted laser cleaning technique. Measurements of cleaning performance and time-resolved optical diagnostics are performed to analyze the physical mechanism of contaminant removal. The results reveal that nanosecond laser pulses are effective for removing the contaminants regardless of the wavelength and that a thermal mechanism involving explosive vaporization of liquid dominates the cleaning process.

  • PDF

Intracavity frequency doubling of a slab Nd:YAG laser pumped by high power diode laser array

  • Lee, Jong-Min;Moon, Hee-Jong;Yi, Jong-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.2 no.1
    • /
    • pp.5-8
    • /
    • 1998
  • A high power diode-array-pumped slab Nd:YAG laser is described. The resonator consists of three mirrors in folded geometry. The laser is operated in acousto-optic Q-switching mode and intracavity frequency doubling is tried. We demonstrate that the laser exhibits frequency doubling efficiency of ∼60% with a type I LBO crystal.

A Study on Pulsed Nd:YAG Laser Welding of Electron Gun in Braun Tubes (I) - Characteristics of Beam Output Energy and Optical Parameters - (브라운관 전자총 부품의 펄스 Nd:YAG레이저 용접에 관한 연구 (I) - 빔의 출력특성과 광학변수 -)

  • 김종도;하승협;조상명
    • Journal of Welding and Joining
    • /
    • v.20 no.4
    • /
    • pp.525-534
    • /
    • 2002
  • During laser spot welding of the braun tube electron gun, phenomena such as serious spattering and oxidative reaction, etc. were occurred. The spatter occurred from weld pool affects the braun tube, namely it blocks up a very small hole on the shadow mask and causes short circuit between two roles of the electron gun. We guessed that high power density and oxidative reaction are main sources of these problems. So, we studied to prevent and to reduce spatter occurring in spot welding of the braun tube electron gun using pulsed Nd:YAG laser. The characteristics of laser output power was estimated, and the loss of laser energy by optical parameter and spatter was measured by powermeter. The effects of welding parameters, laser defocused distance and incident angle, were investigated on the shape and penetration depth of the laser welded bead in flare and flange joints. From these results, the laser peak power was a major factor to control penetration depth and to occur spatter. It was found that the losses of laser energy by optic parameter and sticked spatter affect seriously laser weldability of thin sheets. The deepest penetration depth is gotten on focal position, and a "bead transition" occurred with a slight displacement of focal position relative to the workpiece surface and the absorption rate of the laser energy is affected by the shape factor of the workpiece. When we changed the incident angle of laser beam, the penetration depth was decreased a little with increasing of the incident angle, and the bead width was increased. The spattering was prevented by considering laser beam energy and incident angle.ent angle.

The high repetition operating characteristics of pulsed Nd:YAG laser by alternating charge-discharge system (펄스형 Nd:YAG 레이저의 교번 충.방전 방식에 의한 고반복 동작특성)

  • Kim, W.Y.;Park, K.R.;Kim, B.G.;Hong, J.H.;Kang, U.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2204-2206
    • /
    • 1999
  • Pulsed Nd:YAC laser is used widely for materials processing and instrumentation. It is very important to control the laser energy density in materials processing by a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this study, the alternating charge-discharge system was designed to adjust a pulse repetition rate. This system is controlled by one chip microprocessor and allows to replace an expensive condenser for high frequency to a cheap condenser for low frequency. In addition. we have investigated the current pulse shape of flashlamp and the operating characteristics of a pulsed Nd:YAG laser. As a result, it is found that the laser output of the power supply using the alternating charge-discharge system is not less than that of typical power supply. As the pulse repetition rate rises from 30pps to 120pps by the step of 30pps at 1200V, it is found that the laser efficiency decreases but the laser output power increases about 6W at each step.

  • PDF